Millivolt and Voltage Input
5B30/5B31
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703
2004 Analog Devices, Inc. All rights reserved.
FEATURES
Isolated Voltage Input.
Amplifies, Protects, Filters, & Isolates Analog Input Voltages.
Protect the computer side from damage due to field-side
overvoltage faults.
A Series output switch eliminates the need for external
multiplexing in many applications.
Module circuitry can withstand 240v rms at the input screw-
terminals.
All 5B30 & 5B31 series modules are mix-and-match and Hot
Swappable.
APPLICATIONS
Industrial signal conditioning
Industrial signal isolation
Industrial signal filtering

PRODUCT OVERVIEW
The 5B Series represents an innovative generation of low cost,
high performance plug-in signal conditioners. Designed for
industrial applications, these modules incorporate highly
reliable transformer-based isolation and automated surface-
mount manufacturing technology. They are compact,
economical components whose performance exceeds that
available from more expensive devices. Combining 1500 V rms
continuous isolation, +0.05% calibrated accuracy, small size and
low cost, the 5B Series is an attractive alternative to expensive
signal conditioners and in-house designs
All modules are potted and identical in pin-out and size (2.27" x
2.32" x 0.595"). They can be mixed and matched, permitting
users to address their exact needs, and may be "hot swapped
without disturbing field wiring or power. The isolated input
modules provide 0 to +5V or +5V outputs and accept J, K, T, E,
R, S, N, or B type thermocouples.
These modules feature complete signal conditioning functions
including 240 V rms input protection, filtering, chopper
stabilized low drift +1 uV/oC amplification, 1500 V rms
isolation, and sensor excitation when required.
All modules feature excellent common mode rejection and
meet industrial transient surge withstand specifications.
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 5B30/5B31 Functional Block Diagram
There are also a number of backplanes and mounting sockets
which provide a complete signal conditioning solution for end
users. Each backplane incorporates screw terminals for field
wiring inputs and outputs and cold junction sensors for
thermocouple applications.
These signal conditioners are designed to provide an easy and
convenient solution to signal conditioning problems of both
designers and end users in measurement and control
applications. Typical uses include microcomputer-based
measurement systems, standard data acquisition systems,
programmable controllers, analog recorders and dedicated
control systems. The 5 B series modules are ideally suited to
applications where monitoring and control of temperature,
pressure, flow, rotation and other analog signals are required.
The 5B Series modules and backplanes are approved by Factory
Mutual (FM) and the 5B Series modules are approved by the
Canadian Standards Association (CSA) for use in Class 1,
Division 2, Groups A, B, C, and D locations. These approvals
certify that the 5B Series is suitable for use in locations where a
hazardous concentration of flammable gas may exist only under
fault conditions of operation. Equipment of this category is
called "non-incendive" and they need no special enclosures or
other physical safeguards.
The 5B series modules and backplanes have been tested and
passed the stringent heavy industrial requirements of the
European Union's electromagnetic compatibility (ENC)
directive EN50082-1 and EN50081-2. When used according
to installation directions (refer to 5B series User Manual), any
errors caused by EMI/RFI interference will be less than 0.1% of
the full scale 5B measurement range for field strengths up to 10
V/M and frequencies up to 1 GHz.
5B30 / 5B31
Rev. 0 | Page 2 of 8
GENERAL DESCRIPTION
The 5B30 and 5B31 are single-channel signal conditioning
modules that amplify, protect, filter and isolate analog input
voltages.
The 5B30 and 5B31 protect the computer side from damage due
to field-side over voltage faults. All models withstand 240V rms
at their input terminals without damage thereby shielding
computer side circuitry from field-side over voltage conditions.
In addition, 5B30 and 5B31 Series modules are mix-and-match
and hot swappable, so can be inserted or removed from any
socket in the same backplane without disrupting system power.
A chopper-stabilized input amplifier provides low drift and
stable gain. At the amplifier input, a stable, laser-trimmed zero-
scale input voltage is subtracted from the input signal to set the
zero scale value. For user convenience, the zero can be
optionally factory-set to meet custom needs. This allows
suppression of a zero-scale input value many times larger that
the total span for precise expanded-scale measurements.
Internal multi-pole low-pass filtering with a four-Hz cutoff (-
3dB) enhances normal-mode (noise on signal) and common-
mode (nosie on signal return) rejection at 50/60 Hz, enabling
accurate measurement of small signals in high electrical noise.
Signal isolation by transformer coupling uses a proprietary
modulation technique for linear, stable and reliable
performance. The differential input circuit on the field side is
fully floating, eliminating the need for any input grounding. A
demodulator on the computer side of the signal transformer
recovers the original signal, which is then filtered and buffered
to provide a low-noise, low-impedance output signal. The
output common must be kept within +3 V of power common.
A series output switch eliminates the need for external
multiplexing in many applications. The switch is turned on by
an active-low enable input. If the switch is to be on at all times,
the enable-input should be grounded to power common as it is
on the 5B01 and 5B08 backplanes.
.
Figure2
5B30 / 5B31
Rev. 0 | Page 3 of 8
5B30 / 5B31--SPECIFICATIONS
5B30 and 5B31 Models Available
Model
Input Range
Output Range
5B30-01
-10 mV to +10 mV
-5 V to +5 V
5B30-02
-50 mV to +50 mV
-5 V to +5 V
5B30-03
-100 mV to +100 mV
-5 V to +5 V
5B30-04
-10 mV to +10 mV
0 V to +5 V
5B30-05
-50 mV to +50 mV
0 V to +5 V
5B30-06
-100 mV to +100 mV
0 V to +5 V
5B30-Custom *
*
Model
Input Range
Output Range
5B31-01
-1 V to +1 V
-5 V to +5 V
5B31-02
-5 V to +5 V
-5 V to +5 V
5B31-03
-10 V to +10 V
-5 V to +5 V
5B31-04
-1 V to +1 V
0 V to +5 V
5B31-05
-5 V to +5 V
0 V to +5 V
5B31-06
-10 V to +10 V
0 V to +5 V
5B31-07
-20 V to +20 V
-5 V to +5 V
5B31-Custom *
*
*Custom Input/Output ranges are available. Refer to configuration guide.

5B30 and 5B31 Specifications
Description
Model 5B30
Model 5B31
Input Ranges
Standard Ranges
10 mV to 100 mV
1 V to 20 V
Custom Ranges
5 mV to 500 mV
0.5 V to 20 V
Output Ranges (R
L
> 50 k
)
4
-5 V to +5 V or 0 V to +5 V
*
Accuracy
2
Initial @ +25C
0.05% Span 10 V RTI 0.05% (Vz
1
)
0.05% Span 0.2 mV RTI 0.05% (Vz
1
)
Nonlinearity 0.02%
Span
*
Input Offset vs. Temperature
1 V/C
20 V/C
Output Offset vs. Temperature
20 V/C
*
Gain vs. Temperature
25 ppm of Reading/C
50 ppm of Reading/C
Input Bias Current
3 nA
0.2 nA
Input Resistance
Power On
5 M
650
k
Power Off
40 k
650
k
5B30 / 5B31
Rev. 0 | Page 4 of 8
Overload
40 k
650
k
Noise
Input, 0.1 Hz to 10 Hz Bandwidth
0.2 V rms
2 V rms
Output, 100 kHz Bandwidth
200 V rms
*
Bandwidth, -3 dB
4 Hz
*
Output Rise Time, 10% to 90% Span
200 ms
*
Common-Mode Voltage (CMV)
3
Input-to-Output, Continuous
1500 V rms maximum
*
Output-to-Power, Continuous
3 V maximum
*
Transient ANSI/IEEE
C37.90.1-1989
*
Common-Mode Rejection (CMR)
1 k
Source Imbalance, 50/60 Hz
160 dB (all ranges)
160 dB (span < 2 V)
150 dB (span = 10 V)
Normal Mode Rejection, 50/60 Hz
60 dB
*
Input Protection
Continuous
240 V rms maximum
*
Transient ANSI/IEEE
C37.90.1-1989
*
Output Resistance
4
50
*
Voltage Output Protection
Continuous Short to Ground
*
Output Selection Time
6 s @ C
load
= 0 to 2,000 pF
*
Output Enable Control
Max Logic "0"
+1 V
*
Min Logic "1"
+2.5 V
*
Max Logic "1"
+36 V
*
Input Current "0"
0.4 mA
*
Power Supply Voltage
+5 V 5%
*
Power Supply Current
30 mA
*
Power Supply Sensitivity, RTI
2 V/Vs%
0.4 mV/Vs%
Mechanical Dimensions
2.275" x 2.375" x 0.595"
(57.8 mm x 59.1 mm x 15.1 mm)
*
Environmental
Temperature Range
Rated Performance
-25C to +85C
*
Operating
-40C to +85C
*
Storage
-40C to +85C
*
Relative Humidity
0 to 93% @ +40C non-condensing
*
RFI Susceptibility
0.5% Span error @ 400 MHz, 5 Watt, 3 ft
*
* Specifications same as model 5B30.
1
Vz is the nominal input voltage that results in a 0 V output.
2
Includes the combined effects of repeatability, hysteresis, and nonlinearity and assumes R
L
> 50 k
.
3
The output common must be kept within 3 V of power common.
4
Loads heavier than 50 k
will degrade nonlinearity and gain temperature coefficient.
Specifications subject to change without notice.
5B30 / 5B31
Rev. 0 | Page 5 of 8
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS
Figure 3 5B30 /5B31 Input Field Connections
Table 1. Pin Function Descriptions--
Pin No.
Description
1 NC
2
LOW -
3 HIGH
+
4 NC
Figure 4 . Model 5B Series Module, with pin-out assignments.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human
body and test equipment and can discharge without detection. Although this product features proprietary ESD
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.