ChipFind - документация

Электронный компонент: ADXL05EM-1

Скачать:  PDF   ZIP
REV. A
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
a
FEATURES
High Performance Prepackaged Accelerometers
Complete Acceleration Measurement System
Single and Multiaxis Versions
Small, Low Cost, Ready-to-Use
Available in 4
g or 25 g Full-Scale Ranges
See ADXL150EM Data Sheet for 10
g Modules
+5 V Single Supply Operation
Reliable Industrial Packaging With Screw-Down Mounting
APPLICATIONS
Vibration Analysis, Tilt Sensing, Position and Motion,
Inertial Guidance, Virtual Reality Systems, Seismic and
Earthquake Monitoring, Crash Sensing, Robotic Appli-
cations, Shipping and Transportation Shock Monitor-
ing, Active Suspension Applications, Medical Analysis,
Active Sound Cancellation, and Much More
ADXL50/ADXL05
Evaluation Modules
ADXL50EM-1, ADXL05EM-1/EM-3
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
0.75
(19.05)
36.0 (914.4) TYP
1.00 (25.4)
1.375 (34.93)
1.875 (47.63)
1.0 (25.4)
0.188 (4.78) DIA
FUNCTION
+5VDC
COM RTN
A1 (X) OUT
A2 (Y) OUT
A3 (Z) OUT
COLOR
RED
BLACK
WHITE
YELLOW
GREEN
MODEL
UNI-AXIAL
BI-AXIAL
TRI-AXIAL
CABLE SIGNAL COLOR CODE
0.25 (6.35) R
0.188 (4.78)
DIA
1.00 (25.4)
1.375 (34.93)
1.875 (47.63)
1.00
(25.4)
DESCRIPTION
The ADXLEM Series of evaluation modules provides a com-
plete acceleration measurement system in a low cost package.
The modules simplify the evaluation and testing of our ADXL50
and ADXL05 monolithic accelerometer ICs. Each module con-
tains one or more accelerometers precalibrated to a convenient
output scale factor with onboard low-pass filtering.
All that is required to use these modules is a +5 volt power
supply. The module should be attached (i.e., screwed or glued
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 617/329-4700
World Wide Web Site: http://www.analog.com
Fax: 617/326-8703
Analog Devices, Inc., 1996
down) securely to the object being measured, taking care that
the axis of sensitivity, indicated by the large arrow on the top of
the module, is aligned with the expected acceleration.
Modules are available in other package styles (such as rug-
gedized metallic box) and in other g ranges from NGT Tech-
nology, 3 Cross Road, LaGrangeville, NY 12540-5705,
914-223-3359, and from Crossbow Technology, 2880 North 1st
Street, San Jose, CA 95134, 408-428-6204.
ACCELEROMETER EVALUATION MODULES
Model
ADXL50
ADXL05
ADXL05
EM-1
EM-1
EM-3
Parameters
Single Axis
Single Axis
Tri-Axial
Units
Remarks
Span
25
4
4
g
5%
Sensitivity
80
500
500
mV/g
5%
Bandwidth
DC400 Hz
DC100 Hz
DC100 Hz
Hz
5%
Noise
130 mg
5 mg
5 mg
mg rms
Typical
Orientation
Horizontal
Horizontal
Triaxial
Zero g Output
+2.5
0.1
+2.5
0.1
+2.5
0.1
Volts
@ +25
C
Zero g Drift
60
60
60
mV
0
C to 70
C
0.75
0.12
0.12
g
0
C to 70
C
145
100
100
mV
40
C to +85
C
1.8
0.2
0.2
g
40
C to +85
C
Span Output
2.0
0.1
2.0
0.1
2.0
0.1
Volts
@ +25
C
Nonlinearity
0.2
0.2
0.2
% FS
Typical
Alignment
2
2
2
Degrees
Typical
Transverse Sensitivity
3.5
3.5
3.5
% FS
Typical
Temperature Range
40 to +85
40 to +85
40 to +85
C
Shock
500
500
500
g
Powered
2000
1000
1000
g
Unpowered
Output Loading
>10 k
< 1 nF
>10 k
< 1 nF
>10 k
< 1 nF
Max
Supply Voltage
+5
0.25
+5
0.25
+5
0.25
Volts
Max
Supply Current
10
8
24
mA
Typical
NOTES
1
All frequency break points are 3 dB, single pole, 6 dB per octave roll-off.
2
Nonlinearity is the deviation from a best fit straight line at full scale.
3
Transverse sensitivity is error measured in the primary axis output created by forces induced in the orthogonal axis.
4
Zero g Drift is specified as the typical change in 0 g level from its initial value at +25
C to its worst case value at T
MIN
or T
MAX
.
5
Consult factory for availability of higher bandwidth version of ADXL05EM modules.
6
Transverse sensitivity error is primarily due to the effects of misalignment (i.e., much of it can be tuned out by adjusting the package orientation).
Specifications subject to change without notice.
ADXL50EM-1, ADXL05EM-1/EM-3SPECIFICATIONS
REV. A
2
C2034a212/96
PRINTED IN U.S.A.