FEATURES
LOW THERMAL RESISTANCE -- 1.1C/W
CURRENT FOLDOVER PROTECTION
EXCELLENT LINEARITY -- Class A/B Output
WIDE SUPPLY RANGE -- 10V to 45V
HIGH OUTPUT CURRENT -- Up to 15A Peak
APPLICATIONS
MOTOR, VALVE AND ACTUATOR CONTROL
MAGNETIC DEFLECTION CIRCUITS UP TO 10A
POWER TRANSDUCERS UP TO 100kHz
TEMPERATURE CONTROL UP TO 360W
PROGRAMMABLE POWER SUPPLIES UP TO 90V
AUDIO AMPLIFIERS UP TO 120W RMS
DESCRIPTION
The PA13 is a state of the art high voltage, very high
output current operational amplifier designed to drive resis-
tive, inductive and capacitive loads. For optimum linearity,
especially at low levels, the output stage is biased for class
A/B operation using a thermistor compensated base-emitter
voltage multiplier circuit. The safe operating area (SOA) can
be observed for all operating conditions by selection of user
programmable current limiting resistors. For continuous opera-
tion under load, a heatsink of proper rating is recommended.
The PA13 is not recommended for gains below 3 (inverting)
or +4 (non-inverting).
This hybrid integrated circuit utilizes thick film (cermet) resis-
tors, ceramic capacitors and semiconductor chips to maximize
reliability, minimize size and give top performance. Ultrasoni-
cally bonded aluminum wires provide reliable interconnections
at all operating temperatures. The 12-pin power SIP package
is electrically isolated.
TYPICAL APPLICATION
POWER RATING
Not all vendors use the same method to rate the power han-
dling capability of a Power Op Amp. APEX rates the internal
dissipation, which is consistent with rating methods used by
transistor manufacturers and gives conservative results. Rating
delivered power is highly application dependent and therefore
can be misleading. For example, the 135W internal dissipation
rating of the PA13 could be expressed as an output rating
of 260W for audio (sine wave) or as 440W if using a single
ended DC load. Please note that all vendors rate maximum
power using an infinite heatsink.
THERMAL STABILITY
APEX has eliminated the tendency of class A/B output
stages toward thermal runaway and thus has vastly increased
amplifier reliability. This feature, not found in most other Power
Op Amps, was pioneered by APEX in 1981 using thermistors
which assure a negative temperature coefficient in the quies-
cent current. The reliability benefits of this added circuitry far
outweigh the slight increase in component count.
EXTERNAL CONNECTIONS


EQUIVALENT SCHEMATIC
12-PIN SIP
PACKAGE STYLE DP
Formed leads avaliable
See package styles ED & EE
APEX MICROTECHNOLOGY CORPORATION 5980 NORTH SHANNON ROAD TUCSON, ARIZONA 85741 USA APPLICATIONS HOTLINE: 1 (800) 546-2739
2
ABSOLUTE MAXIMUM RATINGS
SPECIFICATIONS
SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
PA13
PA13A
PARAMETER
TEST CONDITIONS
2, 5
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
INPUT
OFFSET VOLTAGE, initial
T
C
= 25C
2
6
1
4
mV
OFFSET VOLTAGE, vs. temperature
Full temperature range
10
65
*
40
V/C
OFFSET VOLTAGE, vs. supply
T
C
= 25C
30
200
*
*
V/V
OFFSET VOLTAGE, vs. power
T
C
= 25C
20
*
V/W
BIAS CURRENT, initial
T
C
= 25C
12
30
10
20
nA
BIAS CURRENT, vs. temperature
Full temperature range
50
500
*
*
pA/C
BIAS CURRENT, vs. supply
T
C
= 25C
10
*
pA/V
OFFSET CURRENT, initial
T
C
= 25C
12
30
5
10
nA
OFFSET CURRENT, vs. temperature
Full temperature range
50
*
pA/C
INPUT IMPEDANCE, DC
T
C
= 25C
200
*
M
INPUT CAPACITANCE
T
C
= 25C
3
*
pF
COMMON MODE VOLTAGE RANGE
3
Full temperature range
V
S
5 V
S
3
*
*
V
COMMON MODE REJECTION, DC
Full temp. range, V
CM
= V
S
6V
74
100
*
*
dB
GAIN
OPEN LOOP GAIN at 10Hz
T
C
= 25C, 1K load
110
*
dB
OPEN LOOP GAIN at 10Hz
Full temp. range, 8 load
96
108
*
*
dB
GAIN BANDWIDTH PRODUCT @ 1MHz
T
C
= 25C, 8 load
4
*
MHz
POWER BANDWIDTH
T
C
= 25C, 8 load
13
20
*
*
kHz
PHASE MARGIN , A
V
= +4
Full temp. range, 8 load
20
*
OUTPUT
VOLTAGE SWING
3
T
C
= 25C, PA13 = 10A, PA13A = 15A
V
S
6
*
V
VOLTAGE SWING
3
T
C
= 25C, I
O
= 5A
V
S
5
*
V
VOLTAGE SWING
3
Full temp. range, I
O
= 80mA
V
S
5
*
V
CURRENT, peak
T
C
= 25C
10
15
A
SETTLING TIME to .1%
T
C
= 25C, 2V step
2
*
s
SLEW RATE
T
C
= 25C
2.5
4
*
*
V/s
CAPACITIVE LOAD
Full temperature range, A
V
= 4
1.5
*
nF
CAPACITIVE LOAD
Full temperature range, A
V
> 10
SOA
*
POWER SUPPLY
VOLTAGE
Full temperature range
10
40
45
*
*
*
V
CURRENT, quiescent
T
C
= 25C
25
50
*
*
mA
THERMAL
RESISTANCE, AC, junction to case
4
T
C
= 55 to +125C, F > 60Hz
.6
.7
*
*
C/W
RESISTANCE, DC, junction to case
T
C
= 55 to +125C
.9
1.1
*
*
C/W
RESISTANCE, DC, junction to air
T
C
= 55 to +125C
30
*
C/W
TEMPERATURE RANGE, case
Meets full range specification
25
+85
*
*
C
PA13
NOTES: * The specification of PA13A is identical to the specification for PA13 in the applicable column to the left
1. Long term operation at the maximum junction temperature will result in reduced product life. Derate internal power dissipation to
achieve high MTTF.
2. The power supply voltage for all tests is 40, unless otherwise noted as a test condition.
3. +V
S
and V
S
denote the positive and negative supply rail respectively. Total V
S
is measured from +V
S
to V
S
.
4. Rating applies if the output current alternates between both output transistors at a rate faster than 60Hz.
5. Full temperature range specifications are guaranteed but not 100% tested.
PA13/PA13A
SUPPLY VOLTAGE, +Vs to Vs
100V
OUTPUT CURRENT, within SOA
15A
POWER DISSIPATION, internal
135W
INPUT VOLTAGE, differential
V
S
3V
INPUT VOLTAGE, common mode
V
S
TEMPERATURE, pin solder -10s max.
260C
TEMPERATURE, junction
1
175C
TEMPERATURE RANGE, storage
40 to +85C
OPERATING TEMPERATURE RANGE, case
25 to +85C
The exposed substrate contains beryllia (BeO). Do not crush, machine, or subject to temperatures in excess of 850C to
avoid generating toxic fumes.
CAUTION
APEX MICROTECHNOLOGY CORPORATION TELEPHONE (520) 690-8600 FAX (520) 888-3329 ORDERS (520) 690-8601 EMAIL prodlit@apexmicrotech.com
3
TYPICAL PERFORMANCE
GRAPHS
PA13
APEX MICROTECHNOLOGY CORPORATION 5980 NORTH SHANNON ROAD TUCSON, ARIZONA 85741 USA APPLICATIONS HOTLINE: 1 (800) 546-2739
4
load and short circuits to the supply rail or common if the
current limits are set as follows at T
C
= 25C:
SHORT TO V
S
SHORT TO
V
S
C, L, OR EMF LOAD
COMMON
45V
.43A
3.0A
40V
.65A
3.4A
35V
1.0A
3.9A
30V
1.7A
4.5A
25V
2.7A
5.4A
20V
3.4A
6.7A
15V
4.5A
9.0A
These simplified limits may be exceeded with further analysis
using the operating conditions for a specific application.
CURRENT LIMITING
Refer to Application Note 9, "Current Limiting", for details of
both fixed and foldover current limit operation. Visit the Apex web
site at www.apexmicrotech.com for a copy of Power_design.
exe which plots current limits vs. steady state SOA. Beware that
current limit should be thought of as a +/20% function initially
and varies about 2:1 over the range of 55C to 125C.
For fixed current limit, leave pin 4 open and use equations
1 and 2.
R
CL
= 0.65/L
CL
(1)
I
CL
= 0.65/R
CL
(2)
Where:
I
CL
is the current limit in amperes.
R
CL
is the current limit resistor in ohms.
For certain applications, foldover current limit adds a slope
to the current limit which allows more power to be delivered
to the load without violating the SOA. For maximum foldover
slope, ground pin 4 and use equations 3 and 4.
0.65 + (Vo * 0.014)
I
CL
=
(3)
R
CL
0.65 + (Vo * 0.014)
R
CL
=
(4)
I
CL
Where:
Vo is the output voltage in volts.
Most designers start with either equation 1 to set R
CL
for the
desired current at 0v out, or with equation 4 to set R
CL
at the
maximum output voltage. Equation 3 should then be used to
plot the resulting foldover limits on the SOA graph. If equa-
tion 3 results in a negative current limit, foldover slope must
be reduced. This can happen when the output voltage is the
opposite polarity of the supply conducting the current.
In applications where a reduced foldover slope is desired,
this can be achieved by adding a resistor (R
FO
) between pin
4 and ground. Use equations 4 and 5 with this new resistor
in the circuit.
Vo * 0.14
0.65 +
10.14 + R
FO
I
CL
=
(5)
R
CL
Vo * 0.14
0.65 +
10.14 + R
FO
R
CL
=
(6)
I
CL
Where:
R
FO
is in K ohms.
OPERATING
CONSIDERATIONS
PA13
GENERAL
Please read Application Note 1 "General Operating Con-
siderations" which covers stability, supplies, heat sinking,
mounting, current limit, SOA interpretation, and specification
interpretation. Visit www.apexmicrotech.com for design tools
that help automate tasks such as calculations for stability,
internal power dissipation, current limit; heat sink selection;
Apex's complete Application Notes library; Technical Seminar
Workbook; and Evaluation Kits.
SAFE OPERATING AREA (SOA)
The output stage of most power amplifiers has three distinct
limitations:
1. The current handling capability of the transistor geometry
and the wire bonds.
2. The second breakdown effect which occurs whenever the
simultaneous collector current and collector-emitter voltage
exceeds specified limits.
3. The junction temperature of the output transistors.
The SOA curves combine the effect of all limits for this Power
Op Amp. For a given application, the direction and magnitude
of the output current should be calculated or measured and
checked against the SOA curves. This is simple for resistive
loads but more complex for reactive and EMF generating
loads. However, the following guidelines may save extensive
analytical efforts.
1. Capacitive and dynamic* inductive loads up to the following
maximum are safe with the current limits set as specified.
CAPACITIVE LOAD
INDUCTIVE LOAD
V
S
I
LIM
= 5A
I
LIM
= 10A
I
LIM
= 5A
I
LIM
= 10A
50V
200F
125F
5mH
2.0mH
40V
500F
350F
15mH
3.0mH
35V
2.0mF
850F
50mH
5.0mH
30V
7.0mF
2.5mF
150mH
10mH
25V
25mF
10mF
500mH
20mH
20V
60mF
20mF
1,000mH
30mH
15V
150mF
60mF
2,500mH
50mH
*If the inductive load is driven near steady state conditions,
allowing the output voltage to drop more than 12.5V below the
supply rail with I
LIM
= 10A or 27V below the supply rail with I
LIM
= 5A while the amplifier is current limiting, the inductor must
be capacitively coupled or the current limit must be lowered
to meet SOA criteria.
2. The amplifier can handle any EMF generating or reactive

This data sheet has been carefully checked and is believed to be reliable, however, no responsibility is assumed for possible inaccuracies or omissions. All specifications are subject to change without notice.
PA13U REV K NOVEMBER 2003 2003 Apex Microtechnology Corp.