High efficiency topology, 87% typical at 5V
Industry standard footprint
Wide operating temperature, up to and exceeding +70C (natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote on/off
Approvals to EN60950 and UL/cUL1950
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 (input voltage and current requirements)
Complies with ETS 300 386-1
The CXE15 is a new high efficiency open
frame isolated 15 Watt converter series in
an industry standard footprint. The first
four models in the series feature an input
voltage range of 33 to 75VDC and are
available in output voltages of 5V, 3.3V,
2.5V and 1.8V. The output voltage on
each model is adjustable from 90% to
110% of the nominal value. Typical
efficiencies for the models are 87% for the
5V, 86% for the 3.3V, 85% for the 2.5V
and 83% for the 1.8V version. The CXE15
series also has a remote on/off capability,
with active 'HI' or active 'LO' logic options
available. Overcurrent and overvoltage
protection features are included as
standard. With full international safety
approval including EN60950 and
cUL1950, the CXE15 reduces compliance
costs and time to market.
CXE15 48V SERIES
Single output
CXE15 Single Series
| 10.8 to 15W DC/DC
High Efficiency DC/DC Converters
1
[ 2 YEAR WARRANTY ]
TV
SXA10 Series
| 15W DC/DC
CXE15 Single Series
| 10.8 to 15W DC/DC
High Efficiency DC/DC converters
2
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input voltage - turn on
Vin (on)
30
33
36
V DC
Input voltage - turn off
Vin (off)
27
30
33
V DC
Hysteresis
3
V DC
Turn on delay - enabled,
Tdelay
1.5
4
msec
With the enable signal asserted,
then power applied
(power)
this is the time from when the
input voltage reaches the
minimum specified operating
voltage until the output voltage
is within the total regulation
band
Turn on delay - power
Tdelay
2.5
4
msec
Vin = Vin (nom), then enabled.
applied, then enabled
(enable)
This is the time taken until the
output voltage is within the total
error band
Rise time
Trise
0.6
1
msec
From 10% to 90%; full resistive
load, no external capacitance
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any
other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
All specifications are typical at nominal input Vin = 48V, full load under any resistive load combination at 25C unless otherwise stated.
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input voltage - continuous
Vin (cont)
-0.3
75
V DC
Vin(+) - Vin(-)
Input voltage - peak/surge
Vsurge
-0.3
80
V DC
2s max, non-repetitive
Operating temperature
Top
-40
115
C
Measured at thermal reference
points, see Note 1
Storage temperature
Tstorage
-40
120
C
Output power (1.8V)
Pout (max)
10.8
W
Output power (2.5V)
Pout (max)
15
W
Output power (3.3V)
Pout (max)
15
W
Output power (5V)
Pout (max)
15
W
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input voltage - operating
Vin (oper)
33
48
75
V DC
Input current - no load
lin
28
35
mADC
Vin (min) - Vin (max), enabled
Input current - Quiescent
lin (off)
20
25
mADC
Converter disabled
Input voltage variation
dv/dt
5
V/ms
Complies with ETS300 132 Part 4.4
Inrush current (i
2
t)
linrush
300
A
2
s
Complies with ETS300 132 Part 4.7,
with recommended LISN
Inrush current ratio
It/Im
19.5
Complies with ETS300 132 Part 4.7,
with recommended LISN
Input ripple rejection
45
dB
Frequency <1 kHz
Input fuse
2
A Slowblow/antisurge
HRC
recommended, 200V rating
Absolute Maximum Ratings
Input Characteristics
Turn On/Off
CXE15 Single Series
| 10.8 to 15W DC/DC
High Efficiency DC/DC converters
3
www.artesyn.com
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Input to output test voltage
1500
V DC
Test duration 1s
Input to output capacitance
1000
pF
Input to output resistance
100
M
Measured with 500 V DC
Input to output insulation system
Operational
Characteristic - Signal Name Symbol
Min
Typ
Max
Units
Notes and Conditions
At remote/control ON/OFF pin
See Notes 2 and 3
Open collector or equivalent
See Application Note 116 for
compatible
Remote On/Off details
Control pin open circuit voltage
Vih
12
13
V
Iih = 0 A; open circuit voltage
High level input current
Iih
10
A
Current flowing into control pin
when pin is pulled high
(max. at Vih = 75V)
Acceptable high level
Iih (leakage)
-50
A
Acceptable leakage current from
leakage current
signal pin into the open collector
driver (neg = from converter)
Low level input voltage
ViI
0
1.2
V
Converter guaranteed off
when control pin is
less than Vil (max)
Low level input current
IiI
-1.4
mA
Vil = 0.4 V
Low level input current
Iil (max)
-1.5
mA
ViI = 0.0 V;
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Mean time between failure
MTBF
600,000
Hours
MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25C;
ground benign environment
Mean time between failure
MTBF
1,000,000
Hours
per Bellcore TR-NWT-000332
Issue 3, ground benign,
temp. = 40C, Vin = Vin (nom),
Iout = Iout (max)
Mean time between failure
MTBF
TBD
Hours
Demonstrated. This entry will be
periodically updated as the
number of test hours increase
Expected service life
Years
Signal Electrical Interface
Reliability and Service Life
Isolation
SXA10 Series
| 15W DC/DC
CXE15 Single Series
| 10.8 to 15W DC/DC
High Efficiency DC/DC converters
4
Other Specifications
Environmental Specifications
EMC
Electromagnetic Compatibility
Referenced ETSI standards:
ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment
ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations
ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Switching frequency
Fsw
265
kHz
Fixed frequency
Weight
12
g
Phenomenon
Port
Standard
Test level
Criteria
Notes and conditions
Immunity:
ESD
Enclosure
EN61000-4-2
6kV contact
As per ETS 300 386-1 table 5
8kV air
EFT
DC power
EN61000-4-4
2kV
As per ETS 300 386-1 table 5
4kV
Signal
EN61000-4-4
1kV
As per ETS 300 386-1 table 5
2kV
Radiated field
Enclosure
EN61000-4-3
10V/m
As per ETS 300 386-1 table 5
Conducted
DC power
EN61000-4-6
10V
As per ETS 300 386-1 table 5
Signal
EN61000-4-6
10V
Signal line assumed < 3m in length
Input transients
DC power
ETS 300 132, ETR 283
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Thermal performance
1V8 and 2V5 models
-40
70
C
See Notes 1, 4 and
3V5 and 5V models
-40
65
C
individual derating curves
Type
Parameter
Reference
Test Level
Notes and Conditions
Air temperature
Low
IEC 68-2-1
-40C
All characteristics and parameters
High
IEC 68-2-2
+70C
extracted from ETS 300 019
Change
IEC 68-2-14
-40C to +70C
classes 3.1, 3.2, 3.3, 3.4 and 3.5
Tmax. = +70C for T3.4
Relative humidity
Low
-
10%
High
IEC 68-2-56
100%
Condensation
IEC 68-2-30
90 to 100%
Vibration IEC Class 3M5
Freq. velocity
IEC 68-2-6
5-9Hz 5mm/s
Freq. acceleration IEC 68-2-6
9-200Hz 1g
Shocks IEC Class 3M5
Acceleration
IEC 68-2-29
10g
Model Input
Output
Overvoltage
Output
Current
Typical
Max.
Load
Number
Voltage
Voltage
Protection
(Max.)
Efficiency
Regulation
CXE15-48S1V8
33-75 VDC
1.8V
2.3V
6.0A
83%
2.0%
CXE15-48S2V5
33-75 VDC
2.5V
3.2V
6.0A
85%
1.5%
CXE15-48S3V3
33-75 VDC
3.3V
4.0V
4.5A
86%
0.5%
CXE15-48S05
33-75 VDC
5.0V
6.0V
3.0A
87%
0.5%
CXE15 Single Series
| 10.8 to 15W DC/DC
High Efficiency DC/DC converters
5
www.artesyn.com
EMC
Electromagnetic Compatibility
Material Ratings
Model Numbers
Standards Compliance List
Standard
Category
EN60950
2000
UL/cUL 1950
3rd edition
TV Rheinland
EN60950:2000
Characteristic - Signal Name Notes and Conditions
Flammability rating
UL94V-0
Material type
FR4 PCB
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions
Phenomenon
Port
Standard
Test level Criteria
Notes and conditions
Emission:
Conducted
DC power
EN55022
Level A
With recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1. See Application
Note 116 for details
EN55022
Level B
With recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1. See Application
Note 116 for details
Signal
EN55022
Level B
Bandwidth 150kHz to 30MHz,
as per ETS 300 386-1
Radiated
EN55022
Level B
Bandwidth 30 MHz to 1 GHz, as per
ETS 300 386-1
Safety Agency Approvals
Characteristic
UL/cUL 1950 File Number
E135734
TV Rheinland Certificate No.
R2074133