ChipFind - документация

Электронный компонент: EXQ50

Скачать:  PDF   ZIP
DC/DC CONVERTERS 36-50W High Efficiency DC/DC Converters
1
2 YEAR WARRANTY
EXQ50 Series
S i n g l e o u t p u t
High efficiency topology, 90% at 5V and 86.5% typical at 1.8V
Low profile, open-frame package
Industry standard footprint
Wide operating temperature, -40C to +90C
(with derating)
90% to 110% output trim
No minimum load
Remote on/off
EXQ50 series high-efficiency, open-frame, isolated DC/DC converters have an industry
standard quarter-brick footprint and a height of just 0.4 inches. The converters provide
up to 50 Watts of output power, are capable of delivering very high current at low
voltages, and offer exceptional power densities for today's high-end applications. The
first four models in the series feature an input voltage range of 33 to 75VDC and are
available with output voltages of 5.0V, 3.3V, 2.5V or 1.8V. The output voltage of each
model is adjustable from 90% to 110% of its nominal value. Typical efficiencies are
90% for the 5V model, 89% for the 3.3V, 88% for the 2.5V and 86.5% for the 1.8V. All
EXQ50 series converters have a remote on/off capability, and are fully protected against
over-voltage, over-temperature and short-circuit conditions. Featuring full international
safety approval, including EN60950 (TV Product Service) and UL/cUL 60950, EXQ50
series converters reduce compliance costs and time to market.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022 (See Note 2)
Level A
EN55022 (See Note 2)
Level B
Radiated emissions
EN55022
Level A
Immunity:
ESD air
EN61000-4-2
8kV, 15kV
ESD contact
EN61000-4-2
6kV, 8kV
EFT DC Input
EN61000-4-4
2kV (NP)
Radiated field enclosure
EN61000-4-3
10V/m
Conducted (DC power)
EN61000-4-6
10V (NP)
Conducted (signal)
EN61000-4-6
10V (NP)
Input transients
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
1500VDC
Switching frequency
Fixed
350kHz
Approvals and
EN60950 (TV Product Service)
standards (See Note 4)
UL/cUL60950
Material flammability
UL94V-0
Weight
25g (0.88oz)
MTBF
MIL-HDBK-217F
>292,000 hours
@ 40C, 100% load
ground benign
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating temperature
-40C to +90C
Non-operating
-40C to +125C
OUTPUT SPECIFICATIONS
Total error
(See Note 8)
4.5%
Set point accuracy
2.0% max.
Line regulation
Low line to high line
0.3% max.
Load regulation
Full load to min. load
0.3% max.
Voltage adjustability
90% to 110%
Output remote
(See Note 9)
10%
sense range
Minimum load
0A
Overshoot
At turn-on and turn-off
None
Undershoot
None
Ripple and noise
5Hz to 20MHz
120mV pk-pk
30mV rms
Transient response
5% max. deviation
(See Note 1)
200s recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range
48Vin nominal
33 to 75VDC
Input current
No load
60mA
Remote OFF
25mA
Input current (max.)
1.73A max. @ Io max.
(See Note 3)
and Vin = 33
Input reflected ripple
(See Note 5)
110mA (pk-pk)
Active high remote ON/OFF
(See Note 7)
Logic compatibility
Open collector ref to -input
ON
Open circuit or <12VDC
OFF
<1.2VDC
Undervoltage lockout
Power up
32.5V
Power down
30.5V
Start-up time
Power up
10ms
(See Note 6)
Remote ON/OFF
3ms
SPECIFICATIONS
File Name: EXQ50S.PDF Rev: 01 Nov 2002
TV
Data Sheet Artesyn Technologies 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
2.300
0.020 (58.42
0.5)
2.000 (50.80)
0.140 (3.56)
0.435 (11.05)
0.435
(11.05)
0.150 (3.81)
0.300 (7.62)
0.300 (7.62)
0.300 (7.62)
0.450 (11.43)
0.600 (15.24)
0.150 (3.81)
0.062
0.002
(1.57
0.05) 2 Places
0.040
0.002
(1.04
0.05) 6 Places
All dimensions in inches (mm)
All tolerances
0.010in (
0.25mm)
Unless otherwise stated
0.138 (3.50) REF
Vout-
Vin+
Top view
Seating Plane
Remote
on/off
Vin-
Vin-
Remote
on/off
Vin+
Sense-
Trim
Sense+
Vout+
1.450
0.020
(36.83
0.5)
0.400
0.017 (10.18
0.44)
Installed HT
0.017 (0.43)
Min clearance
Bottom view
Vout+
Sense+
Vout-
Trim
Sense-
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TV
TV Product Service. Certificate No. B 01 11 38572 029
Notes
1
di/dt = 0.1A/s, Vin = 48VDC, Tc = 25C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
2
The EXQ50 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 120 for details.
3
Recommended input fusing is a 3.15A HRC 200V rated fuse.
4
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5
Measured with no external Pi filter. Significant reduction possible with
external filter.
6
Start-up into resistive load.
7
Active low remote On/Off is available. Standard product is active high.
When ordering active low parts, designate with the Suffix '-R', e.g
EXQ50-48S3V3-R.
8
This parameter is calculated at worst case line, load, temperature and
initial settings.
9
This is inclusive of the output trim range. If 6.0% trim-up is used, for
example, then only 4.0% output sense is available.
10
Maximum, not typical, specification.
OUTPUT
INPUT
OVP
OUTPUT
OUTPUT
OUTPUT
EFFICIENCY
REGULATION
(10)
MODEL
POWER
VOLTAGE
VOLTAGE
CURRENT
CURRENT
(TYP.)
LINE
LOAD
NUMBER
(7)
(MAX.)
(MIN.)
(MAX.)
36W
33-75VDC
2.3VDC
1.8V
0A
20A
86.5%
0.3%
0.3%
EXQ50-48S1V8
50W
33-75VDC
3.0VDC
2.5V
0A
20A
88.0%
0.3%
0.3%
EXQ50-48S2V5
50W
33-75VDC
3.9VDC
3.3V
0A
15A
89.0%
0.3%
0.3%
EXQ50-48S3V3
50W
33-75VDC
6.0VDC
5.0V
0A
10A
90.0%
0.3%
0.3%
EXQ50-48S05
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit protection
(<20m
short)
Continuous
Overvoltage protection
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
PIN CONNECTIONS
PIN NUMBER
FUNCTION
1
+Vin
2
On/Off
3
-Vin
4
-Vout
5
-Sense
6
Trim
7
+Sense
8
+Vout
EXQ50 Series
S i n g l e o u t p u t
DC/DC CONVERTERS 36-50W High Efficiency DC/DC Converters
2
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
File Name: EXQ50S.PDF Rev: 01 Nov 2002