ChipFind - документация

Электронный компонент: SXE15-48S1V8

Скачать:  PDF   ZIP
DC/DC CONVERTERS 10.8-15W High Efficiency DC/DC Converters
1
2 YEAR WARRANTY
SXE15 Series
S i n g l e o u t p u t
High efficiency topology, 87% typical at 5V
Wide operating temperature, up to and exceeding 70C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote on/off control
The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in
an industry standard footprint. All models in the series feature an input voltage range
of 33 to 75VDC and are available in output voltages of 12V, 5V, 3.3V, 2.5V and 1.8V.
The output voltage on each model is adjustable from 90% to 110% of the nominal
value. Typical efficiencies for the models are 87% for the 5V, 86% for the 3.3V, 85%
for the 2.5V and 12V and 83% for the 1.8V version. The SXE15 series also has a
remote on/off capability with active high or active low logic. Overcurrent and
overvoltage protection features are included as standard. With full international
safety approval including EN60950 and cUL1950, the SXE15 reduces compliance
costs and time to market.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
Radiated emissions
EN55022 (See Longform data sheet) Level B
Immunity:
ESD air
EN61000-4-2 8kV, 15kV
ESD contact
EN61000-4-2 6kV, 8kV
Radiated field enclosure EN61000-4-3 10V/m
Conducted (DC power)
EN61000-4-6 10V
Conducted (signal)
EN61000-4-6 10V
(See Note 12)
Input transients
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
1500VDC
Switching frequency
Fixed
265kHz typ.
Approvals and
UL/cUL1950, EN60950
standards
TV Rheinland
(See Notes 5 and 11)
Material flammability
UL94V-0
Weight
12g (0.42oz)
MTBF
MIL-HDBK-217F
>600,000 hours
Representative model:
48S05 @ 48Vin, 40C,
100% load ground benign
BELLCORE 332
>1,500,000
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
-40C to +65C
(See Note 9)
temp. (5V and 3.3V)
Operating ambient
-40C to +70C
temp. (1.8V, 2.5V
and 12V)
Non-operating
-40C to +120C
(All models)
OUTPUT SPECIFICATIONS
Voltage adjustability
90% to 110%
Total error band
(See Note 14)
4% max.
Line regulation
1V8 and 2V5 models
0.5% max.
Low line to high line
3V3 and S05 models
0.1% max.
Load regulation
1V8 model
2.0% max.
Full load to min. load
2V5 model
1.5% max
3V3 and S05 models
0.5% max.
Minimum load
(See Note 13)
0%
Overshoot
1V8 and 2V5 models
4% max.
At turn-on and turn-off
3V3 and S05 models
None
Undershoot
None
Ripple and noise
1V8 and 2V5 models
40mV pk-pk
(See Note 1)
14mV rms
5Hz to 20MHz
3V3 and S05 models
70mV pk-p
20mV rms
Transient response
1V8 and 2V5 models
150mV
(See Note 2)
3V3 and S05 models
100mV
Typical deviation
400s recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range
48Vin nominal
33 to 75VDC
Input current
No load
35mA max.
Remote OFF
25mA max.
Input current (max.)
(See Note 4)
0.55A max. @ Io max.
and Vin = 33 to 75V
Input reflected ripple
(See Note 6)
5mA (pk-pk) typ.
Active high remote ON/OFF
(See Note 8)
Logic compatibility
Open collector ref to -input
ON
Open circuit or >2VDC
OFF
<1.2VDC
Undervoltage lockout
Power up
33V (typ.)
Power down
30V (typ.)
Start-up time
Power up
1.5ms (typ.)
(See Note 7)
Remote ON/OFF
2.5ms (typ.)
SPECIFICATIONS
TV
File Name: SXE15S.PDF Rev: 17 Oct 2002
Tolerence:
.015 (
.38)
Recommended Land & Hole Pattern
1.575 (40.01)
0.197 (5.00)
0.394 (10.01)
0.063 (1.60)
1.200 (30.48)
0.161 (4.09)
0.125 (3.18)
1.812 (46.02)
0.130 (3.30)
0.047 (1.18)
1.812 (46.02)
1.575 (40.01)
1.885 (47.88)
0.070 (1.78) MAX
1.812 (46.03)
0.335 (8.51) MAX
0.010 (0.25) MIN
1.905 (48.39)
1.390 (35.31)
1.150 (29.21)
leadframe length
overall length
BOTTOM VIEW
SIDE VIEW
TOP VIEW
.050 (1.27)
Non-Skid Retaining Pins,
2 Places
1
0.477 (12.11)
0.502 (12.75)
0.053 (1.36)
All Dimensions in Inches [mm]
0.069 (1.74)
0.197 (5.00)
0.394 (10.01)
1.181 (30.00)
1.378 (35.00)
0.100 (2.54)
12 places
0.063 (1.60)
0.053 (1.36)
1.181 (30.00)
1.378 (35.00)
Data Sheet Artesyn Technologies 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1
Measured as per recommended set-up. See Application Note 116 for details.
2
di/dt = 0.1A/s, Vin = 48VDC, Tc = 25C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
3
The SXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
4
Recommended input fusing is a 2A HRC 200V rated fuse.
5
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6
Measured with external Pi filter. See Application Note 116 for further details.
7
Start-up into resistive load.
8
Active low remote on/off is available. Standard product is active high.
Designate with the Suffix `-R' e.g. SXE15-48S05-R.
9
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
10
SXE15-48S12 below 0.2A loading. OVP is TVS and 17V typical.
11
Approvals pending for the SXE12-48S12.
12
Signal line assumed < 3m in length.
13
A 5% minimum load is required to maintain the output voltage regulation
over all operating conditions for the SXE15-48S12.
14
This parameter is calculated at worst case line, load,
temperature and initial settings.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit protection
Continuous
Overvoltage protection
Latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
PIN CONNECTIONS
PIN NUMBER
FEATURE
1
Vout +
2
Vout -
3
N/C
4
Trim
5
N/C
6
N/C
7
N/C
8
On/Off
9
N/C
10
N/C
11
Vin -
12
Vin +
SXE15 Series
S i n g l e o u t p u t
DC/DC CONVERTERS 10.8-15W High Efficiency DC/DC Converters
2
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TV
TV Rheinland. Certificate No. R2074133
OUTPUT
INPUT
OVP
OUTPUT
OUTPUT
OUTPUT
EFFICIENCY
REGULATION
MODEL
POWER
VOLTAGE
VOLTAGE
CURRENT
CURRENT
(TYP.)
LINE
LOAD
NUMBER
(8)
(MAX.)
(MIN.)
(MAX.)
10.8W
33-75VDC
2.3VDC
1.8V
0A
6A
83%
0.3%
2.0%
SXE15-48S1V8
15W
33-75VDC
3.2VDC
2.5V
0A
6A
85%
0.3%
1.5%
SXE15-48S2V5
15W
33-75VDC
4VDC
3.3V
0A
4.5A
86%
0.1%
0.5%
SXE15-48S3V3
15W
33-75VDC
6VDC
5.0V
0A
3A
87%
0.1%
0.5%
SXE15-48S05
15W
33-75VDC
15VDC
(10)
12.0V
0A
1.25A
85%
0.1%
0.5%
SXE15-48S12
File Name: SXE15S.PDF Rev: 17 Oct 2002