ChipFind - документация

Электронный компонент: ADN10-24-3PM

Скачать:  PDF   ZIP
rev 03.25.05
Technical Support: (888) 41ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
190
Special Features
120-960 Watts
ADN Series
3-Phase
Electrical Specs
Complies with EN61000-3-2
DC OK Signal (indicator)
Adjustable Voltage
Industrial grade design
(no derating to 60C)
User-friendly front panel
Single phase input available
Highly efficient >90% switching technology
High MTBF and reliability
Peak current capability 2x rated
current for 2 seconds
Three year warranty
Input
Nominal voltage
380-480 VAC
Power factor (PFC)
EN61000-3-2
AC Input range
340-576 VAC
DC Input range
450-820 VDC
Frequency
47 - 63 Hz, 500 Hz
Phase
1 or 3 on 5, 10 & 20A* models.
30A & 40A models are 3 only.
Output
Nominal voltage
24V (22.5 - 28.5 VDC Adj.)
Holdup time
>20ms at full load (25C)
Tolerance
<2% overall
(combination line/load/time/temp)
Line regulation
<0.5%
Load regulation
<0.5%
Time & temp. drift
<1%
Initial voltage setting
24.5V 1%
Ripple
<50mVpp
Parallel Operation
Current limit (fold forward)
constant power
10A, 20A, 30A
User selectable
40A
Active single wire parallel
Over voltage protection >30.5 <33 VDC
*On 20A unit, derate to 75% when operating 1.
Storage/shipment
-25C to +85C
Operating
-10C to 60C
(convection)
(derate to 50% at +70C)
Humidity
<90% RH noncondensing
per IEC 68-2-2, 68-2-3
IP20 (EN60529), protection
from moisture & conden-
sation
Note: Derate output to 50% when unit is
mounted sideways or front side up.
EMC
Emissions
EN500081-1, -2 Class B EN55011, EN55022
Radiated and Conducted including Annex A.
Immunity
EN50082-1, -2; EN61000-4-2, Level 4,
EN61000-4-3 Level 3, EN61000-4-6 Level 3;
EN61000-4-4 Level 4 input and Level 3 output;
EN61000-4-5 Isolation Class 4, EN61000-4-11;
Transient resistance according to VDE
0160/W2 over entire load range.
Approvals
CB Scheme, EN60950; EN50178; EN60204;
UL508 Listed, cULus; UL60950, cRUus, CE (LVD
73/23 & 93/68/EEC) EN61000-3-2, IEC 60079-
15 Class 1, Zone 2 hazardous location, Groups
IIA, IIB, IIC w/T3 temp class up to 60C
Ambient.
Protection
Class 1 (IEC536), degree of protection
SELV rated per EN60950
Environmental
Safety
Total Power:
120 - 960 Watts
Input Voltage: 1 or 3 380-480 VAC
# of Outputs:
One
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
191
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Weight
Power
Input Voltage
Current
ADN5-24-3PM
1.7lbs (730g)
120W
380-480VAC
5A
ADN10-24-3PM
2.16lbs (980g)
240W
380-480VAC
10A
ADN20-24-3PM
3.97lbs. (1800g)
480W
380-480VAC
20A
ADN30-24-3PM
4.0lbs (2000g)
720W
380-480VAC
30A
ADN40-24-3PM
6.6lbs (3300g)
960W
380-480VAC
40A
ADN
Series
Catalog Number
Dimensions - inches (mm)
H
W
D
ADN5-24-3PM
4.88 (124)
2.91 (73)
4.55 (116)
Catalog Number
Dimensions - inches (mm)
H
W
D
ADN10-24-3PM
4.88 (124)
3.50 (89)
4.55 (116)
ADN20-24-3PM
4.88 (124)
5.90 (150)
4.55 (116)
ADN30-24-3PM
4.88 (124)
9.72 (247)
4.55 (116)
ADN40-24-3PM
4.88 (124)
11.10 (282)
4.55 (116)
Installation
Fusing
-Input
Internally fused.
-Output
Outputs are capable of providing high currents for short periods of time for inductive load startup or switching.
Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current
overload allows for reliable fuse tripping.
Mounting
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-
PMBRK2 required).
Connections
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm
2
) for solid conductors. 16-12
AWG (0.5-4 mm
2
) for standard conductors. Output: Two connectors per output, connector size range:
16-10 AWG (1.5 - 6mm
2
) for solid conductors.
Case
Fully enclosed metal housing with fine ventilation grid to keep out small parts.
-Free Space
25mm above and below
25 mm left and right
15 mm in front
70 mm above and below
25 mm left and right
15 mm in front