S78LxxF
Positive-Voltage Regulators



Descriptions
This series of fixed-voltage monolithic integrated-circuit voltage regulators is designed for a
wide range of applications. These applications include on-card regulation for elimination of
Noise and distribution problems associated with single-point regulation. In addition, they
can be used with power-pass elements to make high-current voltage regulators. Each of
these regulators can deliver up to 100mA of output current. The internal limiting and
thermal shutdown features of these regulators make them essentially immune to overload.
When used as a replacement for a Zener diode-resistor combination, on effective
improvement in output impedance can be obtained together with lover-bias current.
Features
3-Terminal Regulators
Output Current of 100mA
No External Components
Thermal Overload Protection
Short-Circuit Limit Protection

Ordering
Information
Type NO.
Marking
Package Code
S78LxxF xx SOT-89
xx:Voltage Code (05:5V, 06:6V, 08:8V, 09:9V, 10:10V,12:12V,15:15V,18:18V,24:24V)















S
S
e
e
m
m
i
i
c
c
o
o
n
n
d
d
u
u
c
c
t
t
o
o
r
r
PIN Connections
1. Output voltage
2. GND
3. Input voltage
Outline Dimensions
(Unit : mm )
BLOCK DIAGRAM
Reference
Voltage
I
Startup
Circuit
R2
Error
Amp
O
+
-
GND
V
V
Protection
Circuit
R1
Current
Source
KSI-9013-004
2
S78LxxF

Absolute maximum ratings
Ta=25
C
Characteristics Symbol
Rating
Unit
S78L05
Thru
S78L10
30
S78L12
Thru
S78L18
35
Input Voltage
V
I
S78L24 40
V
Power Dissipation
P
D
500
Junction Temperature
T
J
150
Storage Temperature Range
T
stg
-55 ~ +150
Device Selection Guide
Device Output
Voltage
S78L05F 5V
S78L06F 6V
S78L08F 8V
S78L09F 9V
S78L10F 10V
S78L12F 12V
S78L15F 15V
S78L18F 18V
S78L24F 24V











KSI-9013-004
3
S78LxxF

Electrical Characteristics
(Electrical Characteristics at V
I
=10V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L05
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
4.80 5 5.20
I
O
=1 ~ 40
V
I
=7V ~ 20V
4.75 - 5.25
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=10V
0T
J
125
4.75 - 5.25
V
V
I
=7V ~ 20V
-
32
150
Line Regulation
V
O(VI)
V
I
=8V ~ 20V
T
J
=25
- 26
100
I
O
=1 ~ 100
- 15 60
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 8 30
T
J
=25
- 3.8 6
Quiescent Current
I
QC
-
T
J
=125
- 5.5
V
I
=8V ~ 20V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=8V ~ 18V, f=120
0T
J
125
41 49
Electrical Characteristics
(Electrical Characteristics at V
I
=11V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L06
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
5.75 6 6.25
I
O
=1 ~ 40
V
I
=8V ~ 20V
5.70 - 6.30
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=11V
0T
J
125
5.70 - 6.30
V
V
I
=8V ~ 20V
-
35
175
Line Regulation
V
O(VI)
V
I
=9V ~ 20V
T
J
=25
- 29
125
I
O
=1 ~ 100
- 16 80
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 9 40
T
J
=25
- 3.9 6
Quiescent Current
I
QC
-
T
J
=125
- 5.5
V
I
=9V ~ 20V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=9V ~ 19V, f=120
0T
J
125
40 48
* Pulse testing techniques are used to maintain the junction temperature as close to the ambient
temperature as possible. Thermal effects must be taken into account separately. All characteristics
are measured with a 0.33 capacitor across the input and a 0.1 capacitor across the output.
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.
KSI-9013-004
4
S78LxxF
Electrical Characteristics
(Electrical Characteristics at V
I
=14V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L08
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
7.70 8 8.30
I
O
=1 ~ 40
V
I
=10.5V ~ 23V
7.60 - 8.40
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=14V
0T
J
125
7.60 - 8.40
V
V
I
=10.5V ~ 23V
-
42
175
Line Regulation
V
O(VI)
V
I
=11V ~ 23V
T
J
=25
- 36
125
I
O
=1 ~ 100
- 18 80
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 10 40
T
J
=25
- 4 6
Quiescent Current
I
QC
-
T
J
=125
- 5.5
V
I
=11V ~ 23V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=13V ~ 23V, f=120 0T
J
125
37 46
Electrical Characteristics
(Electrical Characteristics at V
I
=16V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L09
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
8.60 9 9.40
I
O
=1 ~ 40
V
I
=12V ~ 24V
8.55 - 9.45
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=16V
0T
J
125
8.55 - 9.45
V
V
I
=12V ~ 24V
-
45
175
Line Regulation
V
O(VI)
V
I
=13V ~ 24V
T
J
=25
- 40
125
I
O
=1 ~ 100
- 19 90
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 11 40
T
J
=25
- 4.1 6
Quiescent Current
I
QC
-
T
J
=125
- 5.5
V
I
=13V ~ 24V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=15V ~ 25V, f=120 0T
J
125
38 45
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient
temperature as possible. Thermal effects must be taken into account separately. All characteristics
are measured with a 0.33 capacitor across the input and a 0.1 capacitor across the output.
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.
KSI-9013-004
5
S78LxxF
Electrical Characteristics
(Electrical Characteristics at V
I
=17V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L10
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
9.60 10 10.4
I
O
=1 ~ 40
V
I
=13V ~ 25V
9.50 - 10.5
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=17V
0T
J
125
9.50 - 10.5
V
V
I
=13V ~ 25V
-
51
175
Line Regulation
V
O(VI)
V
I
=14V ~ 25V
T
J
=25
- 42
125
I
O
=1 ~ 100
- 20 90
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 11 40
T
J
=25
- 4.2 6
Quiescent Current
I
QC
-
T
J
=125
- 5.5
V
I
=14V ~ 25V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=15V ~ 25V, f=120 0T
J
125
37 44
Electrical Characteristics
(Electrical Characteristics at V
I
=19V, I
O
=40 , C
I
=0.33 , C
O
=0.1 , 0T
J
125, Unless
otherwise specified)
S78L12
Parameter Symbol
Test
Condition*
Min. Typ. Max.
Unit
-
T
J
=25
11.5 12 12.5
I
O
=1 ~ 40
V
I
=14V ~ 27V
11.4 - 12.5
Output Voltage**
V
O
I
O
=1 ~ 70
V
I
=19V
0T
J
125
11.4 - 12.6
V
V
I
=14.5V ~ 27V
-
55
250
Line Regulation
V
O(VI)
V
I
=16V ~ 27V
T
J
=25
- 49
200
I
O
=1 ~ 100
- 22
100
Load Regulation
V
O(IL)
I
O
=1 ~ 40
T
J
=25
- 13 50
T
J
=25
- 4.3 6.5
Quiescent Current
I
QC
-
T
J
=125
- 5
V
I
=16V ~ 27V
-
-
1.5
Quiescent Current
Change
I
QC
I
O
=1 ~ 40
0T
J
125
- - 0.1
Dropout Voltage
V
DROP
- T
J
=25
- 1.7 - V
Ripple Rejection
RR
V
I
=15V ~ 25V, f=120 0T
J
125
37 42
* Pulse testing techniques are used to maintain the junction temperature as close to the ambient
temperature as possible. Thermal effects must be taken into account separately. All characteristics
are measured with a 0.33 capacitor across the input and a 0.1 capacitor across the output.
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.