ChipFind - документация

Электронный компонент: B101120006

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.10.99)
1
Plug
Output
Time ranges
Supply: 24 VAC/DC
Supply: 120 VAC
Supply: 220 VAC
Circular
SPDT
0.15 -
6 s
B 108 024 006
B 108 120 006
B 108 220 006
8 pin
1.5 - 60 s
B 108 024 060
B 108 120 060
B 108 220 060
15
- 600 s
B 108 024 600
B 108 120 600
B 108 220 600
Circular
0.15 - 6 s
B 101 024 006
B 101 120 006
B 101 220 006
11 pin
1.5 - 60 s
B 101 024 060
B 101 120 060
B 101 220 060
15
- 600 s
B 101 024 600
B 101 120 600
B 101 220 600
Circular
DPDT
0.15 -
6 s
B 208 024 006
B 208 120 006
B 208 220 006
8 pin
1.5 - 60 s
B 208 024 060
B 208 120 060
B 208 220 060
15
- 600 s
B 208 024 600
B 208 120 600
B 208 220 600
Circular
0.15 - 6
s
B 201 024 006
B 201 120 006
B 201 220 006
11 pin
1.5 - 60 s
B 201 024 060
B 201 120 060
B 201 220 060
15
- 600 s
B 201 024 600
B 201 120 600
B 201 220 600
Timers
Time ranges
0.15- 6 s
1.5 - 60 s
15
- 600 s
Time range accuracy
0 to +10% on max.
min. actual time
min.
set time
Repeatability deviation
1%
Time variation
Within rated power supply
0.05%/V
and ambient temperature
0.2%/C
Reset
Power supply interruption
Time and/or relay
250 ms
Mono-function, plug-in mini-
ature interval time relays up
to 600 s (10 min) covering 3
individual time ranges. This
economical timer is often
used in applications such as
lubricating pumps, drying ele-
ments, etc. where an opera-
tion is wanted to last for a lon-
ger period of time.
Function
Output
Type
Power supply
Time range
Time ranges: 0.15 s to 600 s
Automatic start
Knob-adjustable time within range
Oscillator-controlled time circuit
Repeatability deviation:
1%
Output: 10 A SPDT or 8 A DPDT relay
Plug-in type module
Scantimer housing
LED-indication for relay on
AC or DC power supply
Interval
Types B 101, B 201, B 108, B 208
Ordering Key
Product Description
Type Selection
Time Specifications
B 108 024 600
2
Specifications are subject to change without notice (25.10.99)
B 108, B 208, B 101, B 201
Power ON delay
200 ms
Power OFF delay
250 ms
Indication for
Output ON
LED. red
Environment
IP 20 B
Pollution degree
2 (IEC 60664)
Operating temperature
-20 to +50C (-4 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Weight
85 g
Approvals
UL, CSA
B 108, B 101
B 208, B 201
Output
SPDT relay
DPDT relay
Basic electrical insulation
250 VAC (rms) (contact/electronics)
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (AgCdO)
(micro gap)
(micro gap)
Resistive loads
AC 1
10 A/250 VAC (2500 VA)
8 A/250 VAC (2000 VA)
DC 1
1 A/250 VDC (250 W)
0.4 A/250 VDC (100 W)
or
10 A/25 VDC (250 W)
4 A/25 VDC (100 W)
Small inductive loads AC 15 2.5 A/230 VAC
2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
30 x 10
6
operations
30 x 10
6
operations
Electrical life
AC 1
2.5 x 10
5
operations (at max. load)
2.5 x 10
5
operations (at max. load)
Operating frequency
7200 operations/h
7200 operations/h
Insulation voltages
Rated insulation voltage
2.0 kVAC (rms) (contact/electronics)
2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt.
4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
4 kV (1.2/50 s) (contact/electronics) (IEC 60664)
Power supply AC types
Installation cat. III
Rated operational voltage
through pins 2 & 10
220
220 VAC + 15/- 20%,
or pins 2 & 7
45 to 65 Hz
120
120 VAC + 15/- 20%,
45 to 65 Hz
024
24 VAC + 15/- 20%,
45 to 65 Hz
Drop-out tolerance
10 ms
Rated insulation voltage
None
Rated transient protection volt.
4 kV (1.2/50 s) @ 220 VAC
2.5 kV (1.2/50 s) @ 120 VAC
800 V (1.2/50 s) @ 24 VAC
(line/neutral)
Power supply DC type
Installation cat. III
Rated operational voltage 024
24 VDC + 15/- 20% (pin 2 pos.)
Rated insulation voltage
None
Rated transient protection volt.
800 V (1.2/50 s)
Consumption
AC supply
60 mA @ 50 Hz/70 mA @ 60 Hz
DC supply
1 W
Power supply
B 108, B 208
Power supply
B 101, B 201
The relay operates and the ti-
me period starts when power
supply is applied to the time
relay.
At the end of the set delay,
the relay releases and will not
operate again until power
supply is reapplied.
Mode of Operation
A recovery period of 250 ms
should be allowed before re-
applying power supply.
If power supply is interrupted
for more than 250 ms before
the time period has expired,
the relay releases and the time
is reset to zero.
Output Specifications
Supply Specifications
General Specifications
Wiring Diagrams
Specifications are subject to change without notice (25.10.99)
3
B 108, B 208, B 101, B 201
Knob-adjustable on scale in
seconds.
Sockets
S 408, S 411
Hold down spring
HF
Mounting rack
SM 13
Socket cover
BB 4
Potentiometer lock
PL 1
For further information refer to "Accessories".
Time Setting
Accessories
Operation Diagram
Power supply
Relay on