ChipFind - документация

Электронный компонент: EAADT231M

Скачать:  PDF   ZIP
Specifications are subject to change without notice (21.12.99)
1
Timers
Delay on Operate
Type EAA
Time range 0.1 s to 10 h
Automatic start
Knob-adjustable time setting
Knob selection of time range
Oscillator-controlled time circuit
Repeat accuracy:
0.2%
Output: 5 A SPDT or 5 A DPDT
For mounting on DIN-rail in accordance with
DIN/EN 50 022
22.5 mm Euronorm housing
LED-indication for relay and power supply ON
Combined AC and DC power supply
Product Description
Ordering Key
Housing
Function
Type
Output
Power supply
Time range
Mono-function timer with 3
selectable time ranges within
0,1 s to 1 m or 1 m to 10 h.
For mounting on DIN-rail.
Often used to prevent over-
loading the power distribution
system, when e.g. pumps
should not be switched on at
the same time.
Type Selection
Mounting
Output
Time range
Supply: 24 VAC/DC & 115-230 VAC
For DIN-rail
SPDT
0.1 s - 1 m
EAA C T23 1M
SPDT
1 m - 10 h
EAA C T23 10H
DPDT
0.1 s - 1 m
EAA D T23 1M
DPDT
1 m - 10 h
EAA D T23 10H
Time Specifications
Time ranges
Type 1 M
Selectable by rotary switch
0.1 s - 1 s
1 s - 10 s
0.1 m - 1 m
Type 10 H
Selectable by rotary switch
1 m - 10 m
0.1 h - 1 h
1 h - 10 h
Time range accuracy
10% on max.
min. setting: actual time
min. set time
Repeat accuracy
0.2%
Time variation
Within rated power supply
0.05%/V
and ambient temperature
0.2%/C
Reset
Time and relay
Power supply interruption
200 ms
Output Specifications
Output
Type C
SPDT relay
Type D
DPDT relay
Rated insulation voltage
250 VAC (contact/elect.)
Contact ratings (AgCdO)
(micro gap)
Resistive loads
AC 1
5 A, 250 VAC
DC 1
5 A, 24 VDC
Small inductive loads AC 15
2 A, 250 VAC
DC 13
3 A, 24 VDC
Mechanical life
40 x 10
6
operations
Electrical life
10
5
operations
(at max. load)
Operating frequency
7200 operations/h
Dielectric strength
Dielectric voltage
2 kVAC (rms)
Rated impulse withstand volt. 4 kV (1.2/50 s)
EAA C T23 1M
2
Specifications are subject to change without notice (21.12.99)
Supply Specifications
Power supply
Overvoltage cat. III (IEC 60664)
Rated operational voltage
(IEC 60038)
through term. A1 & A2
T23
115-230 VAC, -10/+15%
frequency
50/60 Hz, -5/+5 Hz
through term. A2 & A3
T23
24 VAC/DC, -10/+15%
frequency
50/60 Hz, -5/+5 Hz
Voltage interruption
40 ms
Dielectric voltage
None
Rated impulse withstand
voltage
4 kV (1.2/50 s)
Rated operational current
Type C
20 mA @ 24 VDC
40 mA @ 24 VAC
20 mA @ 115 VAC
40 mA @ 230 VAC
Type D
25 mA @ 24 VDC
40 mA @ 24 VAC
30 mA @ 115 VAC
60 mA @ 230 VAC
General Specifications
EMC
Electromagnetic
Compatibility
Immunity
Acc. to IEC 60801-4
Acc. to IEC 60801-5
Power ON delay
200 ms
Power OFF delay
200 ms
Indication for
Power supply ON
LED, green
Output ON
LED, yellow
Environment
Degree of protection
IP 20
Pollution degree
3
Operating temperature
-20 to +50C (-4 to +122F)
Storage temperature
-50 to +85C (-58 to +185F)
Weight
125 g
Screw terminals
Tightening torque
Max. 0,5 Nm acc. to IEC 60947
Approvals
UL, CSA
CE-marking
Yes
EAA
Mode of Operation
The delay period begins
when
power supply is
applied. At the end of the
set delay, the relay will oper-
ate and will not release until
power supply is interrupted
for at least 200 ms. If power
supply is interrupted for at
least 200 ms before the relay
operates, the time circuit is
reset to zero and the relay is
ready for a new time period.
Time Setting
Selection of time ranges
Upper knob:
3-position rotary switch.
Time setting
Lower knob:
Knob-adjustable on relative
scale 1-10.
Wiring Diagrams
Operation Diagram
Power supply
Relay ON
EAA C
EAA D