ChipFind - документация

Электронный компонент: RE2425AA06

Скачать:  PDF   ZIP
2-78
Specifications are subject to change without notice (08.05.2002)
Solid State Relay
Switching mode
Rated operational voltage
Rated operational current
4 to 20 mA control current
Non-rep. off-state peak voltage
AC Solid State Relay
Analog switching for resistive load
applications
4 to 20 mA control current
Rated operational current: 10, 25 and 50 AACrms
Rated operational voltage: Up to 600 VACrms
LED-indication of loop current
Product Description
The analog switching relay
works in accordance with the
phase control principle, i.e.
the output switching point in
the AC sine wave depends on
the control current. 4 to 20
mA corresponds to no switch-
Ordering Key
Solid State Relays
ing and to full sine wave (near
linear). The relay switches off
every time the current crosses
zero, and switches ON in ac-
cordance with the applied
control current.
Type Selection
Switching mode
Rated operational
Rated operational
Control current
Non-rep. voltage
voltage
current
E: Analog switching
24: 115 VACrms
10: 10 AACrms
AA: 4 to 20 mA
06: 650 V
p
230 VACrms
25: 25 AACrms
12: 1200 V
p
48: 400 VACrms
50: 50 AACrms
16: 1600 V
p
480 VACrms
60: 600 VACrms
Selection Guide
Rated operational Non-rep. voltage
Control current
Rated operational current
voltage
10 AACrms
25 AACrms
50 AACrms
115 VACrms
650 V
p
4 to 20 mA
RE 2410 AA 06
RE 2425 AA 06
RE 2450 AA 06
230 VACrms
650 V
p
4 to 20 mA
RE 2410 AA 06
RE 2425 AA 06
RE 2450 AA 06
400 VACrms
1200 V
p
4 to 20 mA
RE 4810 AA 12
RE 4825 AA 12
RE 4850 AA 12
480 VACrms
1200 V
p
4 to 20 mA
RE 4810 AA 12
RE 4825 AA 12
RE 4850 AA 12
600 VACrms
1600 V
p
4 to 20 mA
-
-
RE 6050 AA 16
General Specifications
RE 24.. AA 06
RE 48.. AA 12
RE 6050 AA 16
Operational voltage range
90 to 280 VACrms
265 to 530 VACrms
330 to 660 VACrms
Non-rep. peak voltage
600 V
p
1200 V
p
1600 V
p
Operational frequency range
45 to 65 Hz
45 to 65 Hz
45 to 65 Hz
Power factor
0.5
0.5
0.5
Approvals
UL, CSA
UL, CSA
UL, CSA
CE-marking
Yes
Yes
Yes
Industrial, 1-Phase Analog Switching
Types RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
RE 48 50 AA 12
Specifications are subject to change without notice (08.05.2002)
2-79
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Rated insulation voltage
Input to output
4000 VACrms
Rated insulation voltage
Output to case
4000 VACrms
Insulation resistance
Input to output
10
10
Insulation resistance
Output to case
10
10
Insulation capacitance
Input to output
8 pF
Insulation capacitance
Output to case
50 pF
Insulation
Input Specifications
Control current range
4 to 20 mA
Voltage drop
8 VDC @ 20 mA
Dynamic impedance
100
Allowable input current
50 mA
Reverse polarity protected
Yes
RE ..10 AA ..
RE ..25 AA ..
RE ..50 AA ..
Operating temperature
-20 to +70C (-4 to +158F)
-20 to +70C (-4 to +158F)
-20 to +70C (-4 to +158F)
Storage temperature
-40 to +100C (-40 to +212F)
-40 to +100C (-40 to +212F)
-40 to +100C (-40 to +212F)
Junction temperature
125C (257F)
125C (257F)
125C (257F)
R
th
junction to case
2 K/W
1.25 K/W
0.65 K/W
R
th
junction to ambient
12.5 K/W
12 K/W
12 K/W
Thermal Specifications
Functional Diagram
Control
input
Load output/mains input
Mains input/load output
Control
input
Line/load
Wiring Diagram
Caution:
Current to input must be
limited to max. 50 mA.
RE ..10 AA ..
RE ..25 AA ..
RE ..50 AA ..
RE 6050 AA 16
Rated operational current AC 51 10 Arms
25 Arms
50 Arms
50 Arms
Minimum operational current
500 mArms
500 mArms
500 mArms
500 mArms
Rep. overload current t=1 s
< 35 AACrms
55 AACrms
125 AACrms
125 AACrms
Off-state leakage current
@ rated voltage and frequency*)
< 6 mA
< 6 mA
< 6 mA
< 6 mA
I
2
t for fusing t = 1-10 ms
130 A
2
s
310 A
2
s
1800 A
2
s
1800 A
2
s
Critical dI/dt
100 A/s
100 A/s
100 A/s
100 A/s
Critical dV/dt commutating
500 V/s
500 V/s
500 V/s
500 V/s
Critical dV/dt off-state
500 V/s
500 V/s
500 V/s
500 V/s
Output Specifications
*) Min. power let-through
0.5%. Please refer to Applications.
IC
2-80
Specifications are subject to change without notice (08.05.2002)
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Heatsink Dimensions
(load current versus ambient temperature)
With the output fully on (360
conduction angle)
RE ..10 AA ..
2.7
2.2
1.8
1.3
0.87
0.41
22
3.1
2.6
2.1
1.7
1.2
0.65
20
3.7
3,1
2.6
2
1.5
0.92
18
4.3
3.7
3.1
2.5
1.9
1.2
16
5
4.3
3.7
3
2.3
1.6
15
5.9
5.1
4.4
3.6
2.8
2.1
13
6.9
6
5.2
4.3
3.5
2.6
12
7.9
6.9
5.9
4.9
4
3
10
10.8
9.5
8.1
6.8
5.4
4.1
7
-
14.2
12.2
10.2
8.1
6.1
5
-
-
-
-
14.6
10.9
3
-
-
-
-
-
-
1
20
30
40
50
60
70
16
15
14
13
12
11
10
9
7
5
3
1
Load
current [A]
Thermal resistance
[K/W]
T
A
Ambient temp. [
C]
Power
dissipation [W]
RE ..50 AA ..
T
A
Ambient temp. [
C]
0.92
0.76
0.60
0.45
0.29
- 63
1.2
0.99
0.80
0.62
0.44
0.26
55
1.5
1.3
1.1
0.85
0.63
0.42
47
1.9
1.6
1.4
1.1
0.89
0.63
40
2.4
2.1
1.8
1.5
1.2
0.91
33
3
2.7
2.3
1.9
1.5
1.1
26
3.9
3.5
3
2.5
2
1.5
20
5.5
4.8
4.1
3.4
2.7
2.1
15
8.6
7.5
6.4
5.4
4.3
3.2
9
17.9
15.6
13.4
11.2
8,9
6.7
4
20
30
40
50
60
70
50
45
40
35
30
25
20
15
10
5
Power
dissipation [W]
Thermal resistance
[K/W]
Load
current [A]
RE ..25 AA ..
Power
dissipation [W]
2
1.7
1.4
1
0.71
0.40 32
2.5
2.1
1.8
1.4
1
0.66
27
3.1
2.7
2.3
1.9
1.4
1
23
4
3.5
3
2.5
2
1.4
20
4.9
4.3
3.7
3.1
2.5
1.9
16
6.2
5.4
4.6
3.9
3.1
2.3
13
8.1
7.1
6.1
5.1
4
3
10
11.3
9.9
8.5
7.1
5.6
4.2
7
-
15.6
13.3
11.1
8.9
6.7
5
-
-
-
-
18.7
14
2
20
30
40
50
60
70
25
22.5
20
17.5
15
12.5
10
7.5
5
2.5
T
A
Ambient temp. [
C]
Load
current [A]
Thermal resistance
[K/W]
Carlo Gavazzi Heatsink
(see Accessories)
No heatsink required
RHS 100 Assy
RHS 301 Assy
RHS 301 F Assy
Consult your distributor
Heatsink Selection
Thermal resistance
R
th s-a
> 12.5
K/W
3.0 K/W
0.8 K/W
0.25 K/W
< 0.25 K/W
Compare the value found in the current versus temperature
chart with the standard heatsink values and select the heat-
sink with the next lower value.
Specifications are subject to change without notice (08.05.2002)
2-81
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Applications
This relay is suitable for tem-
perature control or control of
lighting.
The relay can also be used for
soft turn-on of high-power in-
candescent lamps.
Load
4 to
20 mA
L
C
F
I
in
U
line
RE 24.. AA 06
U
L
= 230 V
RE 48.. AA 12
U
L
= 480 V
RE 6050 AA 16 U
L
= 600 V
Application hints:
L and C must be connected
as close as possible to the
SSR.
Max. unit variation:
5% @ Tj = 25
C
Temperature variation:
5% @ Tj = -20
to + 125
C
I
in
[mA]
P
out
[%]
typically 50/60 Hz
4
0.5
6
8
8
22
10
40
12
54
14
66
16
75
18
81
20
86
25
92
Transfer characteristics
Output power as a function of control input (4 to 20 mA)
Dimensions
**
***
***
*** ***
***
***
**
** =
0.4 mm
*** =
0.5 mm
Housing Specifications
Weight
Approx. 110 g
Housing material
Noryl GFN 1, black
Base plate
Aluminium
Potting compound
Polyurethane
Relay
Mounting screws
M5
Mounting torque
1.5 Nm
Control terminal
Mounting screws
M3 x 6
Mounting torque
0.5 Nm
Power terminal
Mounting screws
M5 x 6
Mounting torque
2.4 Nm
Accessories
Protection cover
Heatsinks
DIN rail adapter
Varistors
Fuses
L: Optional radio interfer-
ence low-pass filter com-
ponent
C: Optional radio interfer-
ence low-pass filter com-
ponent
For further information refer