ChipFind - документация

Электронный компонент: VC12RT23010M

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.06.99)
1
Level Sensors
Capacitive level sensor for solid,
fluid or granulated substances
Adjustable sensing distance: 4-12 mm
VC11/12RT: With adjustable time delay
VC12RN: Without time delay
Product Description
Ordering Key
VC11RT12010M
Capacitive sensor in thermo-
plastic polyester for mount-
ing in PG 36 screw gland.
Available with adjustable
sensing distance and with/-
without built-in time delay
(ON or OFF delay). The relay
output ensures that the load
can be driven directly. Ex-
cellent for use in the agricul-
ture area (detection of grains,
fluids etc.).
Type
Time delay
Voltage
Time
Specifications
Supply voltage
Ordering no.
Ordering no.
Ordering no.
With ON delay
With OFF delay
Without time delay
120 VAC
VC 11RT12010M
VC 12RT12010M
VC 12RN120
230 VAC
VC 11RT23010M
VC 12RT23010M
VC 12RN230
24 VAC/DC
VC 11RT92410M
VC 12RT92410M
VC 12RN924
Type Selection
Rated operational voltage
120
120 VAC, 47-63 Hz
230
230 VAC, 47-63 Hz
924
24 VAC/DC, 47-63 Hz (VAC)
Consumption
Max. 1,5 W
Sensing distance
4-12 mm, adjustable
Hysteresis
1,5 mm at 7 mm sensing dist.
Operating frequency
1 Hz
Output
Relay SPDT, 2 A/240 VAC
Indication for output ON
LED, yellow
Time delay
VC11/12RT
1 s - 10 m
Environment
Degree of protection
IP 67
Operating temperature
-20 to +70C (-4 to +158F)
Storage temperature
-40 to +85C (-40 to +185F)
Housing material
Thermoplastic polyester
Cable
PVC, 2 m
Approvals
CSA (only with OFF delay)
CE-marking
Yes
Capacitive
Types VC11RT, VC12RT, VC12RN
VC11RT/VC12RT
VC12RN
Wiring Diagram
2 A
240 V~
BN
BU
GR
YE
BK
Sensitivity and time delay
Dimensions
Sensitivity
2
Specifications are subject to change without notice (25.06.99)
Mode of Operation
VC11RT (See operation dia-
gram). Power supply is
applied to the sensor (brown
and blue cables). When sen-
sor is not activated, the relay
operates (connection be-
tween black and yellow
cables) and LED lights.
When sensor is activated the
time measurement starts
and LED flashes. After expi-
ration of the set time (0-10
min.), the relay releases
(connection between black
and grey cables) and LED
turns off. The relay remains
released until sensor is acti-
vated again.
VC12RN (See operation dia-
gram). Power supply is
applied to the sensor (brown
and blue cables). The relay
operates (connection be-
tween black and yellow
cables) and remains ON until
the sensor is activated. After
activation of the sensor the
relay releases (connection
between black and grey
cables.)
VC12RT (See operation dia-
gram). Power supply is
applied to the sensor (brown
and blue cables) and time
measurement starts. When
the set time has expired (0-
10 min.) the relay operates
(connection between black
and yellow cable) and
remains connected until the
sensor is activated. After
activation of the sensor the
relay releases (connection
between black and grey
cable). As soon as the sen-
sor is unactivated again the
time measurements of the
set time starts.
Adjustment
VC12RN
VC1.RT
DELAY
1 s - 10 min
DISTANCE
4 - 12 mm
LED
LED
DISTANCE
4 - 12 mm
Operation Diagrams
Power supply (brown - blue cable)
Sensor activated
LED indication
Relay ON
VC12RN
VC11RT
Power supply (brown - blue cable)
Sensor activated
Relay (black - yellow cable)
LED indication
VC12RT
Power supply (brown - blue cable)
Sensor activated
Relay ON (black - yellow cable)
LED indication
VC11RT, VC12RT, VC12RN
Installation Hint
For mounting VC 11/12 through wall of tank
Delivery Contents
Capacitive switch: VC11/12
Screwdriver
Packaging: Plastic bag
User manual