ChipFind - документация

Электронный компонент: LCC120

Скачать:  PDF   ZIP
1
www.clare.com
LBA127L
DS-LBA127L-R4
LBA127L is 250V, 200mA, 10
independent 1-Form-A
and 1-Form-B relays. It features a superior combination of
low on-resistance and enhanced peak load current han-
dling capabilities. Current limiting version is available ("L"
suffix, see specification for variations in performance).
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
Small 8 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
RMS
Input/Output Isolation
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Current Limiting, Surface Mount and Tape & Reel
Version Available
Applications
Features
Description
Approvals
DUAL POLE OptoMOS
Relay
Ordering Information
Part #
Description
LBA127L
8 Pin DIP (50/Tube)
LBA127LS
8 Pin Surface Mount (50/Tube)
LBA127LSTR
8 Pin Surface Mount (1000/Reel)
LBA127L
Units
Load Voltage
250
V
Load Current
200
mA
Max R
ON
10
Pin Configuration
Switching Characteristics of
Normally Open (Form A) Devices
CONTROL
LOAD
10ms
10%
10%
90%
+
T
ON
T
OFF
+
+
Switching Characteristics of
Normally Closed (Form B) Devices
CONTROL
10ms
10%
90%
90%
+
+
T
ON
T
OFF
+
1
2
3
4
+ Control - Normally Closed
Control - Normally Closed
+ Control - Normally Open
Control - Normally Open
8
Normally Closed Pole
Normally Open Pole
7
6
5
Pinout
AC/DC Configuration
www.clare.com
LBA127L
Rev. 4
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25 C)
2
Parameter
Min
Typ
Max Units
Input Power Dissipation
-
-
150
1
mW
Input Control Current
-
-
50
mA
Peak (10ms)
-
-
1
A
Reverse Input Voltage
-
-
5
V
Total Power Dissipation
-
-
800
2
mW
Isolation Voltage
Input to Output
3750
-
-
V
RMS
Operational Temperature
-40
-
+85
C
Storage Temperature
-40
-
+125
C
Soldering Temperature
DIP Package
-
-
+260
C
Flatpack/Surface Mount
Package
-
-
+220
C
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/C
2
Derate Linearly 6.67 mw/C
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25C
Load Voltage (Peak)
-
V
L
-
-
250
V
Load Current (Continuous)
AC/DC Configuration
-
I
L
-
-
150
mA
Peak Load Current
10ms
I
LPK
-
-
-
mA
On-Resistance
AC/DC Configuration
I
L
=Load Current
R
ON
-
8
15
Off-State Leakage Current
V
L
=250V
I
LEAK
-
-
1
A
Switching Speeds
Turn-On
I
F
=5mA, V
L
=10V
T
ON
-
-
5
ms
Turn-Off
I
F
=5mA, V
L
=10V
T
OFF
-
-
5
ms
Output Capacitance
50V; f=1MHz
C
OUT
-
110
-
pF
Input Characteristics @ 25C
Input Control Current
I
L
=Load Current
I
F
5
-
50
mA
Input Dropout Current
-
I
F
0.4
0.7
-
mA
Input Voltage Drop
I
F
=5mA
V
F
0.9
1.2
1.4
V
Reverse Input Voltage
-
V
R
-
-
5
V
Reverse Input Current
V
R
=5V
I
R
-
-
10
A
Input to Output Capacitance
-
C
I/O
-
3
-
pF
Input to Output Isolation
-
V
I/O
3750
-
-
V
RMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
LBA127L
www.clare.com
Rev. 4
PERFORMANCE DATA*
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
3
LBA127L
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25
C; I
F
= 5mADC)
35
30
25
20
15
10
5
0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
Device Count (N)
LBA127L - Form A
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC, I
F
= 5mADC)
35
30
25
20
15
10
5
0
11.25
12.25
13.25
14.25
11.75
12.75
13.75
On-Resistance (
)
Device Count (N)
LBA127L - Form B
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC, I
F
= 5mADC)
30
25
20
15
10
5
0
5.325
5.665
6.005
6.345
5.495
5.835
6.175
On-Resistance (
)
Device Count (N)
LBA127L - Form A
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25
C)
35
30
25
20
15
10
5
0
262.5
272.5
282.5
292.5
267.5
277.5
287.5
Blocking Voltage (V)
Device Count (N)
LBA127L - Form B
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25
C)
30
25
20
15
10
5
0
310
318
326
334
314
322
330
Blocking Voltage (V)
Device Count (N)
LBA127L - Form A
Typical I
F
for Switch Dropout
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC)
25
20
15
10
5
0
0.63
0.99
1.35
0.45
0.81
1.17
1.53
LED Current (mA)
Device Count (N)
LBA127L - Form A
Typical I
F
for Switch Operation
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC)
0.45
0.81
1.17
0.63
0.99
1.53
LED Current (mA)
Device Count (N)
25
20
15
10
5
0
1.35
LBA127L - Form B
Typical I
F
for Switch Operation
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC)
30
25
20
15
10
5
0
1.4
1.8
2.6
3.4
2.2
LED Current (mA)
Device Count (N)
3.0
LBA127L - Form B
Typical I
F
for Switch Dropout
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC)
25
20
15
10
5
0
1.4
2.2
3.0
1.0
1.8
2.6
3.4
LED Current (mA)
Device Count (N)
LBA127L - Form A
Typical Turn-On Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC; I
F
= 5mADC)
0.33
0.77
1.43
0.55
0.99
Turn-On (ms)
Device Count (N)
25
20
15
10
5
0
1.21
LBA127L - Form B
Typical Turn-On Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC; I
F
= 5mADC)
0.03
0.07
0.11
0.05
0.09
0.13
Turn-On (ms)
Device Count (N)
30
25
20
15
10
5
0
LBA127L - Form A
Typical Turn-Off Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC; I
F
= 5mADC)
0.08
0.05
0.14
0.20
0.17
0.11
Turn-Off (ms)
Device Count (N)
25
20
15
10
5
0
www.clare.com
4
LBA127L
Rev. 4
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LBA127L - Form B
Typical Turn-Off Time
(N=50 Ambient Temperature = 25
C)
(Load Current = 170mADC; I
F
= 5mADC)
1.05
1.65
2.25
1.95
1.35
0.75
Turn-Off (ms)
Device Count (N)
30
25
20
15
10
5
0
LBA127L - Form A
Typical Load Current vs. Temperature
Temperature (
C)
Load Current (mA)
-40
300
250
200
150
100
50
0
-20
0
20
40
60
80
120
100
5mA
10mA
20mA
LBA127L - Form B
Typical Load Current vs. Temperature
Temperature (
C)
Load Current (mA)
-40
300
250
200
150
100
50
0
-20
0
20
40
60
80
120
100
5mA
LBA127L
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
Temperature (
C)
Leakage (
A)
-40
0.045
0.040
0.035
0.030
0.025
0.020
0.015
0.010
0.005
0
-20
0
20
40
60
80
100
LBA127L - Form A
Typical Blocking Voltage vs. Temperature
Temperature (
C)
Blocking Voltage (V
RMS
)
-40
290
285
280
275
270
265
260
255
-20
0
20
40
60
80
100
LBA127L - Form B
Typical Blocking Voltage vs. Temperature
Temperature (
C)
Blocking Voltage (V
RMS
)
-40
400
350
300
250
200
150
100
50
0
-20
0
20
40
60
80
100
LBA127L - Form A
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
Turn-On (ms)
3.0
2.5
2.0
1.5
1.0
0.5
0
-40
-20
0
20
40
60
80
120
100
5mA
10mA
20mA
LBA127L - Form B
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
Turn-On (ms)
-40
0.12
0.10
0.08
0.06
0.04
0.02
0
-20
0
20
40
60
80
100
5mA
LBA127L - Form A
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
Turn-Off (ms)
-40
0.18
0.16
0.14
0.12
0.10
0.08
0.06
0.04
-20
0
20
40
60
80
100
5mA
LBA127L - Form B
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
Turn-Off (ms)
-40
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-20
0
20
40
60
80
100
5mA
10mA
20mA
LBA127L
Typical LED Forward Voltage Drop
vs. Temperature
Temperature (
C)
LED Forward Voltage Drop (V)
-40
1.8
1.6
1.4
1.2
1.0
0.8
-20
0
20
40
60
80
120
100
50mA
30mA
20mA
10mA
5mA
LBA127L - Form A
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
LED Forward Current (mA)
Turn-On (ms)
0
5
10
15
20
25
30
35
40
45
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
50
LBA127L
www.clare.com
5
Rev. 4
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
LBA127L - Form A
Typical Current Limiting vs. Temperature
I
F
= 5mADC
Temperature (
C)
Current (mA)
400
350
300
250
200
150
100
50
0
-40
-20
0
20
40
60
80
120
100
LBA127L - Form B
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
LED Forward Current (mA)
Turn-On (ms)
0
5
10
15
20
25
30
35
40
45
0.06
0.05
0.04
0.03
0.02
0.01
50
LBA127L - Form A
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
LED Forward Current (mA)
Turn-Off (ms)
0
5
10
15
20
25
30
35
40
45
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0
50
LBA127L - Form B
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
LED Forward Current (mA)
Turn-Off (ms)
0
5
10
15
20
25
30
35
40
45
1.6
1.4
1.2
1.0
0.8
0.6
50
LBA127L - Form A
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; I
F
= 5mADC)
Temperature (
C)
On-Resistance (
)
-40
60
50
40
30
20
10
0
-20
0
20
40
60
80
100
LBA127L - Form B
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; I
F
= 5mADC)
Temperature (
C)
On-Resistance (
)
-40
-20
0
20
40
60
80
100
9
8
7
6
5
4
3
2
1
0
LBA127L - Form A
Typical I
F
for Switch Operation vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0
-20
0
20
40
60
80
100
LBA127L - Form B
Typical I
F
for Switch Operation vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
LED Current (mA)
-40
4.500
4.000
3.500
3.000
2.500
2.000
1.500
-20
0
20
40
60
80
100
LBA127L - Form A
Typical I
F
for Switch Dropout vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0
-20
0
20
40
60
80
100
LBA127L - Form B
Typical I
F
for Switch Dropout vs. Temperature
(Load Current = 170mADC)
Temperature (
C)
LED Current (mA)
-40
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-20
0
20
40
60
80
100
LBA127L - Form A
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25
C; I
F
= 5mADC)
Load Voltage (V)
Load Current (mA)
200
150
100
50
0
-50
-100
-150
-200
-1.5
-2.0
-2.5
-0.5
-1.0
0
0.5 1.0 1.5 2.0 2.5
LBA127L - Form B
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25
C; I
F
= 5mADC)
Load Voltage (V)
Load Current (mA)
200
150
100
50
0
-50
-100
-150
-200
-1.0
-0.6
-0.2
-0.4
-0.8
0
0.2 0.4 0.6 0.8 1.0
LBA127L
Energy Rating Curve
Time
Load Current (A)
10
s
1.2
1.0
0.8
0.6
0.4
0.2
0
1ms
100
s
100ms
1s
10ms
10s
100s