ChipFind - документация

Электронный компонент: UBD1.2

Скачать:  PDF   ZIP
561
DESCRIPTION
www.cpclare.com
HIGH-SPEED TRANSIENT SURGE PROTECTORS
UNI-IMPS
DESCRIPTION
STANDARD VOLTAGES
APPLICATIONS
FEATURES
CP Clare's UNI-IMP high-speed transient surge protectors (0.55-20kV) provide the ultimate protection from high-
energy, fast-rising transients such as Nuclear EMP. These devices are constructed using a proprietary
semiconductor junction process that results in nanosecond response times combined with peak current ratings in
excess of 20kA. A unique benefit of this technology is that the breakdown voltage is virtually independent of the
rise time of the transient. In addition, the low capacitance of these devices allows for direct placement on high-
frequency lines and antenna feeds without excessive loading.
s
Fast impulse breakdown (
120% of typical DC
breakdown to 200kV/
s)
s
Tight DC breakdown voltage tolerance (
10%)
s
Non-radioactive
s
Low capacitance
s
Antenna feedlines
s
Test equipment
s
Video displays
s
Medical electronics
s
Instrumentation circuits
Series
DC Breakdown
Unit
Voltage (typ)
UBD
550
V
600
V
650
V
750
V
850
V
1.0
kV
1.2
kV
1.5
kV
2.0
kV
2.5
kV
3.0
kV
4.0
kV
UBT
4.0
kV
and
5.0
kV
UGT
6.0
kV
7.5
kV
10.0
kV
12.0
kV
15.0
kV
20.0
kV
(See detailed specifications for more information.)
SPECIFICATIONS
562
North America: 1-800-CPCLARE
Europe: 32-11-300868
Asia: 886-2-2523-6368
Japan: 81-3-3980-2212
HIGH-SPEED TRANSIENT SURGE PROTECTORS
UNI-IMPS
All characteristics at 25C
UBD-550
UBD-600
UBD-650
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
495
550
605
540
600
660
585
650
715
V
Impulse Breakdown
5kV/
s
V
bd
-
-
660
-
-
720
-
-
780
V
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
20.0
-
-
20.0
-
-
20.0
pF
Life Ratings
Surge Life
3kA (PW=15
s)
-
330
-
-
420
-
-
500
-
-
surges
UBD-750
UBD-850
UBD-1.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
675
750
825
765
850
935
900
1000
1100
V
Impulse Breakdown
5kV/
s
V
bd
-
-
900
-
-
1020
-
-
1200
V
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
20.0
-
-
20.0
-
-
15.0
pF
Life Ratings
Surge Life
3kA (PW=15
s)
660
-
-
830
-
-
1080
-
-
surges
UBD-1.2
UBD-1.5
UBD-2.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
1.08
1.20
1.32
1.35
1.50
1.65
1.80
2.00
2.20
kV
Impulse Breakdown
5kV/
s
V
bd
-
-
1.44
-
-
1.80
-
-
2.40
kV
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
15.0
-
-
15.0
-
-
10.0
pF
Life Ratings
Surge Life
3kA (PW=15
s)
-
1410
-
-
1900
-
-
2400
-
-
surges
UBD-2.5
UBD-3.0
UBD-4.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
2.25
2.50
2.75
2.70
3.00
3.30
3.60
4.00
4.40
kV
Impulse Breakdown
5kV/
s
V
bd
-
-
3.00
-
-
3.60
-
-
4.80
kV
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
10.0
-
-
5.0
-
-
5.0
pF
Life Ratings
Surge Life
3kA (PW=15
s)
-
2400
-
-
2400
-
-
2400
-
-
surges
UBT-4.0
UBT-5.0
UBT-6.0
UGT-4.0
UGT5.0
UGT-6.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
3.60
4.00
4.40
4.50
5.00
5.50
5.40
6.00
6.60
kV
Impulse Breakdown
5kV/
s
V
bd
-
-
4.80
-
-
6.00
-
-
7.20
kV
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
5.0
-
-
3.0
-
-
3.0
pF
Life Ratings
Surge Life
10kA (PW=5
s)
-
1300
-
-
1300
-
-
1300
-
-
surges
SPECIFICATIONS
563
www.cpclare.com
HIGH-SPEED TRANSIENT SURGE PROTECTORS
UNI-IMPS
All characteristics at 25C
UBT-15.0
UBT-20.0
UGT-15.0
UGT-20.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
13.5
15.0
16.5
18.0
20.0
22.0
kV
Impulse Breakdown
5KV/
s
V
bd
-
-
18.0
-
-
24.0
kV
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
2.0
-
-
2.0
pF
Life Ratings
Surge Life
10kA (PW=5
s)
-
1300
-
-
1300
-
-
surges
MECHANICAL DIMENSIONS
DIMENSIONS
mm
(inches)
ORDERING INFORMATION
14.96
0.79 DIA.
(0.589
0.031)
20.64
1.59
(0.812
0.063)
14.29
1.59
(0.562
0.063)
6.32
1.59
(0.249
0.063)
UBD SERIES
14.96
0.79 DIA.
(0.589
0.031)
30.16
1.59
(1.187
0.063)
7.94
1.59
(0.312
0.063)
7.94
1.59
(0.312
0.063)
UBT SERIES
14.22
0.79 DIA.
(0.560
0.031)
54.28
1.59
(2.137
0.063)
7.94
1.59
(0.312
0.063)
7.94
1.59
(0.312
0.063)
UGT SERIES
UBT-7.5
UBT-10.0
UBT-12.0
UGT-7.5
UGT-10.0
UGT-12.0
PARAMETER
CONDITIONS
SYMBOL MIN TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Device Specifications
DC Breakdown
100V/s
V
BD
6.75
7.50
8.25
9.0
10.0
11.0
10.8
12.0
13.2
kV
Impulse Breakdown
5KV/
s
V
bd
-
-
4.8
-
-
6
-
-
7.2
kV
Insulation Resistance
100V
IR
10
10
-
-
10
10
-
-
10
10
-
-
Capacitance
1MHz
C
-
-
5.0
-
-
3.0
-
-
3.0
pF
Life Ratings
Surge Life
10kA (PW=5
s)
-
1300
-
-
1300
-
-
1300
-
-
surges
UBT- X.X
for 4.0-9.0kV
UBT-XX.X
for 10.0-20.0kV
UGT- X.X
for 4.0-9.0kV
UGT-XX.X
for 10.0-20.0kV
Series
UBD
UBT
UGT
Breakdown Voltage
See specifications
tables
UNI-IMPS with other breakdown voltages in the 0.55 to 20kV range
are available on request. All UNI-IMPs are available with .360 O.D.
endcaps. UGTs are also available with .250 O.D. endcaps. UBDs are
available with a threaded male termination (#8-20) on one end.
A complete part number is represented by the digits below.
Breakdown voltages are expressed in Volts for devices <1000V and
kV for devices
1kV. For example, UBD-550 is a 550V UBD series
device, and UBT-10.0 is a 10kV UBT series device.