ChipFind - документация

Электронный компонент: ASPF240D3R

Скачать:  PDF   ZIP
Integral Heat Sink Design
For High Ratings
DC Control, AC Output
SCR Output
Crydom's Patente d Design
The Series ASPF Solid State Relay incor-
porates Crydom's patented PowerFin
TM
design technology with an intregal heat
sink on the compact Mini-SIP package.
FastFax Document No. 113
SERIES ASPF
Rev. 011602
PAGE 1 OF 1
Series ASPF
3.0 Amp 240 Vac AC MINI-SIP
Rated at 3.0 Amps up to 45C, this
SPST-NO AC output SSR is the pre-
ferred choice for applications where
precise electrical power control is essen-
tial. With no mechanical or moving
parts the ASPF is perfect for repetitive
switching where reliability and durabili-
ty are required. Zero voltage or random
switching (R suffix) versions are offered.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
M O D E L N O .
ASPF240D3
ASPF240D3R
INPUT SPECIFICATIONS
Control Voltage Range
4-10 Vdc
4-10 Vdc
Nominal Input Impedance
300 Ohm
300 Ohm
Typical Input Current @ 5 Vdc
15 mAdc
15 mAdc
Must Turn On Voltage
4.0 Vdc
4.0 Vdc
Must Turn Off Voltage
1.0 Vdc
1.0 Vdc
OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz)
24-280 Vrms
24-280 Vrms
Load Current Range
.1 - 3.0 Arms
.1 - 3.0 Arms
Transient Over-Voltage
600 Vpk
600 Vpk
Max. Surge Current, (16.6ms)
40 Apk
40 Apk
Min. Off-State dv/dt @ Max. Rated Voltage
500 V/sec
500 V/sec
Max.Off-State Leakage @ Rated Voltage
0.1 mArms
0.1 mArms
Max. On-State Voltage Drop @ Rated Current
1.5 Vpk
1.5 Vpk
Max.Turn-On Time
1/2 cycle
0.1 msec
Max. Turn-Off TIme
1/2 cycle
1/2 cycle
Power Factor (Min.) WIth Max. Load
0.5
0.5
GENERAL SPECIFICATIONS
Dielectric Strength
3750 Vrms
Insulation Resistance (Min.) @ 500 Vdc
10
9
Ohm
Max. Capacitance
8.0 pF
A
mbient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-30 to 125C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
0.35 oz. (10 g)
Encapsulation:
Thermally Conductive Epoxy
C U R R E N T D E R A T I N G C U R V E
.95
(24.1)
.66
(16.8)
.100
(2.5)
.500
(12.7)
.700
(17.8)
.030
(0.8)
.93
TYP.
(23.6)
.015
(0.4)
.25
(6.4)
1
2
3
4
TM
3.0
1.5
1.0
0
20
40
60
80
AMBIENT TEMPERATURE (C)
LOAD CURRENT (AMPS)
2.0
2.5
Max. Load Current vs. Temp.
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: ---DC CONTROL
G E N E R A L N O T E S
All parameters at 25C unless otherwise specified.
Dielectric and insulation resistance are measured between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
2001 CRYDOM, Specifications subject to change without notice.
All dimensions are in inches (millimeters)
APPROVALS
UL
E116950
CSA LR81689
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506