ChipFind - документация

Электронный компонент: 1516A-40-4.0B

Скачать:  PDF   ZIP
1516
Doc #97029
DATA DELAY DEVICES, INC.
1
2/7/97
3 Mt. Prospect Ave. Clifton, NJ 07013
5-TAP DIP/SMD DELAY LINE
T
D
/T
R
= 3
(SERIES 1516)
FEATURES
PACKAGES
5 taps of equal delay increment
Delays to 200ns
Low profile
Epoxy encapsulated
Meets or exceeds MIL-D-23859C
FUNCTIONAL DESCRIPTION
The 1516-series device is a fixed, single-input, five-
output, passive delay line. The signal input (IN) is
reproduced at the outputs (T1-T5) in equal increments.
The delay from IN to T5 (T
D
) and the characteristic
impedance of the line (Z) are determined by the dash
number. The rise time (T
R
) of the line is 30% of T
D
, and
the 3dB bandwidth is given by 1.05 / T
D
. The device is
available in a 8-pin DIP (1516) or a 8-pin SMD (1516S),
and a wide range of pinouts may be specified.
Part numbers are constructed according to the scheme
shown at right. For example, 1516C-101-500B is a 290
mil DIP, 100ns, 50
delay line with pinout code B.
Similarly, 1516SB-151-501 is a 240 mil SMD, 150ns,
500
delay line with standard pinout.
SERIES SPECIFICATIONS
Dielectric breakdown:
50 Vdc
Distortion @ output:
10% max.
Operating temperature:
-55
C to +125
C
Storage temperature:
-55
C to +125
C
Temperature coefficient: 100 PPM/
C
PINOUT CODES
CODE
IN
T1
T2
T3
T4
T5
GND
STD
2
3
4
5
6
7
1,8
A
1
2
3
4
6
7
5,8
B
1
7
3
6
4
5
8
C
7
2
6
3
5
4
1,8
D
1
2
7
3
6
4
5,8
MOUNTING HEIGHT CODES
CODE
HEIGHT (MAX)
DIP
SMD
A
0.187
Yes
No
B
0.240
Yes
Yes
C
0.290
Yes
Yes
Note:
Codes A and B are not available
for all values of T
D
Contact technical staff for details
data
delay
devices,
inc.
3
IN
Signal Input
T1-T5 Tap Outputs
GND
Ground
Note: Standard pinout shown
Other pinouts available
8
7
6
5
1
2
3
4
GND
IN
T1
T2
GND
T5
T4
T3
DELAY TIME
Expressed in nanoseconds (ns)
First two digits are significant figures
Last digit specifies # of zeros to follow
IMPEDANCE
Expressed in nanoseconds (ns)
First two digits are significant figures
Last digit specifies # of zeros to follow
PINOUT CODE
See Table
Omit for STD pinout
MOUNTING HEIGHT CODE
See Table
PART NUMBER CONSTRUCTION
1516(S)m - xxx - zzz p
DELAY SPECIFICATIONS
T
D
T
I
T
R
ATTENUATION (%) TYPICAL
(ns)
(ns)
(ns)
Z=50
Z=100
Z=200
Z=300
Z=500
5
1.0
3.0
N/A
5
N/A
N/A
N/A
10
2.0
4.0
3
5
5
N/A
N/A
15
3.0
5.0
3
5
5
N/A
N/A
20
4.0
6.0
3
5
5
5
N/A
25
5.0
7.0
3
5
5
5
7
30
6.0
10.0
3
5
5
5
7
40
8.0
13.0
3
5
5
5
7
50
10.0
15.0
3
5
5
7
7
60
12.0
20.0
3
5
6
7
8
75
15.0
25.0
3
5
6
7
8
80
16.0
26.0
4
5
6
7
8
100
20.0
30.0
4
5
6
7
8
110
22.0
32.0
4
5
6
7
8
125
25.0
40.0
4
5
6
7
8
150
30.0
50.0
N/A
5
8
10
10
180
36.0
60.0
N/A
7
8
10
10
200
50.0
70.0
N/A
8
10
12
12
Notes: T
I
represents nominal tap-to-tap delay increment
Tolerance on T
D
=

5% or

2ns, whichever is greater
Tolerance on T
I
=

5% or

1ns, whichever is greater
"N/A" indicates that delay is not available at this Z
1997 Data Delay Devices
1516
Doc #97029
DATA DELAY DEVICES, INC.
2
2/7/97
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
FUNCTIONAL DIAGRAM
GND
IN
T5
T1
T2
T3
T4
GND
PACKAGE DIMENSIONS
1516-xx (DIP)
See
Table
.500 MAX.
1
2
3
4
5
6
7
8
.015 TYP.
.070 MAX.
.018
TYP.
.300
.010
3 Equal spaces
each .100
.010
Non-Accumulative
.280
MAX.
.350
MAX.
.010
.002
Lead Material:
Nickel-Iron alloy 42
TIN PLATE
1516S-xx (Gull-Wing)
See
Table
.520 MAX.
1
2
3
4
5
6
7
8
.430
TYP.
.020
TYP.
.040
TYP.
.100
.110
.300
.270
TYP.
.010 TYP.
.050
TYP.
1516
Doc #97029
DATA DELAY DEVICES, INC.
3
2/7/97
3 Mt. Prospect Ave. Clifton, NJ 07013
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature:
25
o
C
3
o
C
R
load
:
10M
Input Pulse:
High = 3.0V typical
C
load
:
10pf
Low = 0.0V typical
Threshold: 50% (Rising & Falling)
Source Impedance:
50
Max.
Rise/Fall Time:
3.0 ns Max. (measured
at 10% and 90% levels)
Pulse Width (T
D
<= 75ns): PW
IN
= 100ns
Period
(T
D
<= 75ns): PER
IN
= 1000ns
Pulse Width (T
D
> 75ns): PW
IN
= 2 x T
D
Period
(T
D
> 75ns): PER
IN
= 10 x T
D
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
Timing Diagram For Testing
T
RISE
T
FALL
PER
IN
PW
IN
T
RISE
T
FALL
10%
10%
50%
50%
90%
90%
50%
50%
V
IH
V
IL
V
OH
V
OL
INPUT
SIGNAL
OUTPUT
SIGNAL
T
RISE
T
FALL
10%
10%
90%
90%
IN
T1
OUT
TRIG
IN
TRIG
Test Setup
DEVICE UNDER
TEST (DUT)
OSCILLOSCOPE
PULSE
GENERATOR
50
R
OUT
R
IN
R
IN
= R
OUT
= Z
LINE
T2
T3
T4
T5