ChipFind - документация

Электронный компонент: B57164K0104J000

Скачать:  PDF   ZIP

Document Outline

NTC thermistors for
temperature measurement
Leaded NTCs,
lead spacing 5 mm
Series/Type:
B57164
Date:
March 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Applications
Temperature compensation
Temperature measurement
Temperature control
Features
Wide resistance range
Cost-effective
Lacquer-coated thermistor disk
Tinned copper leads
Lead spacing 5.0 mm
Marked with resistance and tolerance
Delivery mode
Bulk (standard),
cardboard tape, reeled or in Ammo pack
Dimensional drawing
Dimensions in mm
Approx. weight 0.4 g
General technical data
Climatic category
(IEC 60068-1)
55/125/21
Max. power
(at 25
C)
P
25
450
mW
Resistance tolerance
R
R
/R
R
5,
10
%
Rated temperature
T
R
25
C
Dissipation factor
(in air)
th
approx. 7.5
mW/K
Thermal cooling time constant
(in air)
c
approx. 20
s
Heat capacity
C
th
approx. 150
mJ/K
Electrical specification and ordering codes
R
25
No. of R/T
characteristic
B
25/100
K
Ordering code
+ =
Resistance tolerance
J =
5%
K =
10%
15
1203
2900
3%
B57164K0150+000
22
1203
2900
3%
B57164K0220+000
33
1203
2900
3%
B57164K0330+000
47
1302
3000
3%
B57164K0470+000
68
1303
3050
3%
B57164K0680+000
100
1305
3200
3%
B57164K0101+000
150
1305
3200
3%
B57164K0151+000
220
1305
3200
3%
B57164K0221+000
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 2 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
R
25
No. of R/T
characteristic
B
25/100
K
Ordering code
+ =
Resistance tolerance
J =
5%
K =
10%
330
1306
3450
3%
B57164K0331+000
470
1306
3450
3%
B57164K0471+000
1 k
1011
3730
3%
B57164K0102+000
1.5 k
1013
3900
3%
B57164K0152+000
2.2 k
1013
3900
3%
B57164K0222+000
3.3 k
4001
3950
3%
B57164K0332+000
4.7 k
4001
3950
3%
B57164K0472+000
6.8 k
2903
4200
3%
B57164K0682+000
10 k
2904
4300
3%
B57164K0103+000
15 k
1014
4250
3%
B57164K0153+000
22 k
1012
4300
3%
B57164K0223+000
33 k
1012
4300
3%
B57164K0333+000
47 k
4003
4450
3%
B57164K0473+000
68 k
2005
4600
3%
B57164K0683+000
100 k
2005
4600
3%
B57164K0104+000
150 k
2005
4600
3%
B57164K0154+000
220 k
2007
4830
3%
B57164K0224+000
330 k
2006
5000
3%
B57164K0334+000
470 k
2006
5000
3%
B57164K0474+000
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 3 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
Reliability data
Test
Standard
Test conditions
R
25
/R
25
(typical)
Remarks
Storage in
dry heat
IEC
60068-2-2
Storage at upper
category temperature
T: 125
C
t: 1000 h
< 3%
No visible
damage
Storage in damp
heat, steady state
IEC
60068-2-78
Temperature of air: 40
C
Relative humidity of air: 93%
Duration: 21 days
< 3%
No visible
damage
Rapid temperature
cycling
IEC
60068-2-14
Lower test temperature:
55
C
Upper test temperature: 125
C
Number of cycles: 100
< 3%
No visible
damage
Endurance
P
max
: 450 mW
t: 1000 h
< 3%
No visible
damage
Long-term stability
(empirical value)
Temperature: 125
C
t: 10000 h
< 5%
No visible
damage
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 4 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
R/T characteristics
B57164K0150J000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 15
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
453.8
382.3
525.3
15.8
2.8
5.6
50.0
344.5
293.3
395.7
14.9
2.7
5.4
45.0
264.2
227.2
301.2
14.0
2.7
5.2
40.0
204.8
177.8
231.7
13.2
2.6
5.0
35.0
160.1
140.2
179.9
12.4
2.6
4.8
30.0
126.3
111.6
141.0
11.7
2.5
4.7
25.0
100.5
89.52
111.5
10.9
2.4
4.5
20.0
80.64
72.38
88.89
10.2
2.4
4.3
15.0
65.17
58.93
71.40
9.6
2.3
4.2
10.0
53.06
48.32
57.80
8.9
2.2
4.0
5.0
43.49
39.88
47.11
8.3
2.1
3.9
0.0
35.89
33.12
38.66
7.7
2.0
3.8
5.0
29.80
27.67
31.93
7.1
2.0
3.7
10.0
24.89
23.25
26.54
6.6
1.9
3.5
15.0
20.91
19.64
22.18
6.1
1.8
3.4
20.0
17.67
16.69
18.65
5.5
1.7
3.3
25.0
15.00
14.25
15.75
5.0
1.6
3.2
30.0
12.80
12.09
13.51
5.5
1.8
3.1
35.0
10.98
10.32
11.63
6.0
2.0
3.0
40.0
9.455
8.845
10.06
6.4
2.2
2.9
45.0
8.180
7.617
8.743
6.9
2.4
2.9
50.0
7.108
6.588
7.627
7.3
2.6
2.8
55.0
6.200
5.722
6.679
7.7
2.9
2.7
60.0
5.430
4.989
5.871
8.1
3.1
2.6
65.0
4.773
4.368
5.179
8.5
3.3
2.5
70.0
4.211
3.837
4.585
8.9
3.6
2.5
75.0
3.728
3.383
4.072
9.2
3.8
2.4
80.0
3.310
2.993
3.628
9.6
4.1
2.3
85.0
2.949
2.656
3.243
9.9
4.4
2.3
90.0
2.636
2.365
2.907
10.3
4.6
2.2
95.0
2.363
2.112
2.613
10.6
4.9
2.2
100.0
2.124
1.892
2.355
10.9
5.2
2.1
105.0
1.914
1.699
2.129
11.2
5.5
2.1
110.0
1.730
1.530
1.929
11.5
5.8
2.0
115.0
1.567
1.382
1.752
11.8
6.1
2.0
120.0
1.423
1.251
1.595
12.1
6.4
1.9
125.0
1.296
1.135
1.456
12.4
6.7
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 5 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0150K000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 15
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
453.8
359.6
547.9
20.8
3.7
5.6
50.0
344.5
276.1
412.9
19.9
3.7
5.4
45.0
264.2
214.0
314.4
19.0
3.6
5.2
40.0
204.8
167.5
242.0
18.2
3.6
5.0
35.0
160.1
132.2
187.9
17.4
3.6
4.8
30.0
126.3
105.3
147.4
16.7
3.6
4.7
25.0
100.5
84.49
116.5
15.9
3.5
4.5
20.0
80.64
68.35
92.92
15.2
3.5
4.3
15.0
65.17
55.67
74.66
14.6
3.5
4.2
10.0
53.06
45.67
60.46
13.9
3.4
4.0
5.0
43.49
37.70
49.28
13.3
3.4
3.9
0.0
35.89
31.33
40.46
12.7
3.4
3.8
5.0
29.80
26.18
33.42
12.1
3.3
3.7
10.0
24.89
22.01
27.78
11.6
3.3
3.5
15.0
20.91
18.60
23.23
11.1
3.2
3.4
20.0
17.67
15.80
19.53
10.5
3.2
3.3
25.0
15.00
13.50
16.50
10.0
3.1
3.2
30.0
12.80
11.45
14.15
10.5
3.4
3.1
35.0
10.98
9.769
12.18
11.0
3.6
3.0
40.0
9.455
8.372
10.54
11.4
3.9
2.9
45.0
8.180
7.208
9.152
11.9
4.2
2.9
50.0
7.108
6.233
7.982
12.3
4.4
2.8
55.0
6.200
5.412
6.989
12.7
4.7
2.7
60.0
5.430
4.718
6.142
13.1
5.0
2.6
65.0
4.773
4.129
5.418
13.5
5.3
2.5
70.0
4.211
3.627
4.795
13.9
5.6
2.5
75.0
3.728
3.197
4.258
14.2
5.9
2.4
80.0
3.310
2.827
3.794
14.6
6.2
2.3
85.0
2.949
2.509
3.390
14.9
6.6
2.3
90.0
2.636
2.233
3.038
15.3
6.9
2.2
95.0
2.363
1.994
2.731
15.6
7.2
2.2
100.0
2.124
1.786
2.461
15.9
7.6
2.1
105.0
1.914
1.603
2.224
16.2
7.9
2.1
110.0
1.730
1.444
2.015
16.5
8.3
2.0
115.0
1.567
1.304
1.831
16.8
8.6
2.0
120.0
1.423
1.180
1.667
17.1
9.0
1.9
125.0
1.296
1.070
1.521
17.4
9.4
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 6 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0220J000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 22
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
665.5
560.7
770.4
15.8
2.8
5.6
50.0
505.2
430.2
580.3
14.9
2.7
5.4
45.0
387.5
333.2
441.7
14.0
2.7
5.2
40.0
300.3
260.7
339.9
13.2
2.6
5.0
35.0
234.8
205.7
263.9
12.4
2.6
4.8
30.0
185.3
163.7
206.9
11.7
2.5
4.7
25.0
147.4
131.3
163.5
10.9
2.4
4.5
20.0
118.3
106.2
130.4
10.2
2.4
4.3
15.0
95.58
86.43
104.7
9.6
2.3
4.2
10.0
77.83
70.88
84.78
8.9
2.2
4.0
5.0
63.79
58.49
69.09
8.3
2.1
3.9
0.0
52.64
48.58
56.71
7.7
2.0
3.8
5.0
43.71
40.58
46.83
7.1
2.0
3.7
10.0
36.51
34.10
38.92
6.6
1.9
3.5
15.0
30.67
28.81
32.53
6.1
1.8
3.4
20.0
25.91
24.47
27.35
5.5
1.7
3.3
25.0
22.00
20.90
23.10
5.0
1.6
3.2
30.0
18.77
17.74
19.81
5.5
1.8
3.1
35.0
16.10
15.13
17.06
6.0
2.0
3.0
40.0
13.87
12.97
14.76
6.4
2.2
2.9
45.0
12.00
11.17
12.82
6.9
2.4
2.9
50.0
10.42
9.663
11.19
7.3
2.6
2.8
55.0
9.094
8.392
9.796
7.7
2.9
2.7
60.0
7.964
7.318
8.611
8.1
3.1
2.6
65.0
7.001
6.406
7.596
8.5
3.3
2.5
70.0
6.176
5.628
6.724
8.9
3.6
2.5
75.0
5.467
4.962
5.972
9.2
3.8
2.4
80.0
4.855
4.389
5.321
9.6
4.1
2.3
85.0
4.326
3.896
4.756
9.9
4.4
2.3
90.0
3.866
3.469
4.263
10.3
4.6
2.2
95.0
3.465
3.098
3.832
10.6
4.9
2.2
100.0
3.114
2.775
3.454
10.9
5.2
2.1
105.0
2.807
2.492
3.122
11.2
5.5
2.1
110.0
2.537
2.244
2.829
11.5
5.8
2.0
115.0
2.298
2.027
2.570
11.8
6.1
2.0
120.0
2.087
1.835
2.340
12.1
6.4
1.9
125.0
1.900
1.665
2.135
12.4
6.7
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 7 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0220K000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 22
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
665.5
527.4
803.6
20.8
3.7
5.6
50.0
505.2
404.9
605.6
19.9
3.7
5.4
45.0
387.5
313.8
461.1
19.0
3.6
5.2
40.0
300.3
245.7
354.9
18.2
3.6
5.0
35.0
234.8
193.9
275.6
17.4
3.6
4.8
30.0
185.3
154.4
216.1
16.7
3.6
4.7
25.0
147.4
123.9
170.9
15.9
3.5
4.5
20.0
118.3
100.2
136.3
15.2
3.5
4.3
15.0
95.58
81.65
109.5
14.6
3.5
4.2
10.0
77.83
66.98
88.67
13.9
3.4
4.0
5.0
63.79
55.30
72.28
13.3
3.4
3.9
0.0
52.64
45.95
59.34
12.7
3.4
3.8
5.0
43.71
38.40
49.02
12.1
3.3
3.7
10.0
36.51
32.28
40.75
11.6
3.3
3.5
15.0
30.67
27.28
34.06
11.1
3.2
3.4
20.0
25.91
23.18
28.64
10.5
3.2
3.3
25.0
22.00
19.80
24.20
10.0
3.1
3.2
30.0
18.77
16.80
20.75
10.5
3.4
3.1
35.0
16.10
14.33
17.87
11.0
3.6
3.0
40.0
13.87
12.28
15.45
11.4
3.9
2.9
45.0
12.00
10.57
13.42
11.9
4.2
2.9
50.0
10.42
9.142
11.71
12.3
4.4
2.8
55.0
9.094
7.937
10.25
12.7
4.7
2.7
60.0
7.964
6.920
9.009
13.1
5.0
2.6
65.0
7.001
6.056
7.946
13.5
5.3
2.5
70.0
6.176
5.319
7.033
13.9
5.6
2.5
75.0
5.467
4.689
6.246
14.2
5.9
2.4
80.0
4.855
4.147
5.564
14.6
6.2
2.3
85.0
4.326
3.680
4.972
14.9
6.6
2.3
90.0
3.866
3.275
4.456
15.3
6.9
2.2
95.0
3.465
2.925
4.006
15.6
7.2
2.2
100.0
3.114
2.619
3.610
15.9
7.6
2.1
105.0
2.807
2.352
3.263
16.2
7.9
2.1
110.0
2.537
2.118
2.956
16.5
8.3
2.0
115.0
2.298
1.912
2.685
16.8
8.6
2.0
120.0
2.087
1.730
2.444
17.1
9.0
1.9
125.0
1.900
1.570
2.230
17.4
9.4
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 8 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0330J000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 33
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
998.3
841.1
1156
15.8
2.8
5.6
50.0
757.9
645.3
870.5
14.9
2.7
5.4
45.0
581.2
499.8
662.6
14.0
2.7
5.2
40.0
450.5
391.1
509.8
13.2
2.6
5.0
35.0
352.2
308.5
395.8
12.4
2.6
4.8
30.0
277.9
245.5
310.3
11.7
2.5
4.7
25.0
221.1
196.9
245.3
10.9
2.4
4.5
20.0
177.4
159.2
195.6
10.2
2.4
4.3
15.0
143.4
129.6
157.1
9.6
2.3
4.2
10.0
116.7
106.3
127.2
8.9
2.2
4.0
5.0
95.68
87.73
103.6
8.3
2.1
3.9
0.0
78.96
72.87
85.06
7.7
2.0
3.8
5.0
65.56
60.87
70.25
7.1
2.0
3.7
10.0
54.77
51.16
58.38
6.6
1.9
3.5
15.0
46.01
43.22
48.80
6.1
1.8
3.4
20.0
38.86
36.71
41.02
5.5
1.7
3.3
25.0
33.00
31.35
34.65
5.0
1.6
3.2
30.0
28.16
26.60
29.72
5.5
1.8
3.1
35.0
24.15
22.70
25.59
6.0
2.0
3.0
40.0
20.80
19.46
22.14
6.4
2.2
2.9
45.0
18.00
16.76
19.24
6.9
2.4
2.9
50.0
15.64
14.49
16.78
7.3
2.6
2.8
55.0
13.64
12.59
14.69
7.7
2.9
2.7
60.0
11.95
10.98
12.92
8.1
3.1
2.6
65.0
10.50
9.609
11.39
8.5
3.3
2.5
70.0
9.264
8.442
10.09
8.9
3.6
2.5
75.0
8.201
7.443
8.958
9.2
3.8
2.4
80.0
7.283
6.584
7.982
9.6
4.1
2.3
85.0
6.489
5.844
7.134
9.9
4.4
2.3
90.0
5.799
5.203
6.394
10.3
4.6
2.2
95.0
5.198
4.647
5.748
10.6
4.9
2.2
100.0
4.672
4.162
5.182
10.9
5.2
2.1
105.0
4.211
3.738
4.683
11.2
5.5
2.1
110.0
3.805
3.367
4.244
11.5
5.8
2.0
115.0
3.448
3.040
3.855
11.8
6.1
2.0
120.0
3.131
2.752
3.510
12.1
6.4
1.9
125.0
2.850
2.497
3.203
12.4
6.7
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 9 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0330K000
R/T No.
1203
T (
C)
B
25/100
= 2900 K, R
25
= 33
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
998.3
791.2
1205
20.8
3.7
5.6
50.0
757.9
607.4
908.4
19.9
3.7
5.4
45.0
581.2
470.8
691.6
19.0
3.6
5.2
40.0
450.5
368.5
532.4
18.2
3.6
5.0
35.0
352.2
290.9
413.4
17.4
3.6
4.8
30.0
277.9
231.6
324.2
16.7
3.6
4.7
25.0
221.1
185.9
256.3
15.9
3.5
4.5
20.0
177.4
150.4
204.4
15.2
3.5
4.3
15.0
143.4
122.5
164.3
14.6
3.5
4.2
10.0
116.7
100.5
133.0
13.9
3.4
4.0
5.0
95.68
82.94
108.4
13.3
3.4
3.9
0.0
78.96
68.92
89.01
12.7
3.4
3.8
5.0
65.56
57.60
73.52
12.1
3.3
3.7
10.0
54.77
48.42
61.12
11.6
3.3
3.5
15.0
46.01
40.92
51.10
11.1
3.2
3.4
20.0
38.86
34.77
42.96
10.5
3.2
3.3
25.0
33.00
29.70
36.30
10.0
3.1
3.2
30.0
28.16
25.20
31.13
10.5
3.4
3.1
35.0
24.15
21.49
26.80
11.0
3.6
3.0
40.0
20.80
18.42
23.18
11.4
3.9
2.9
45.0
18.00
15.86
20.14
11.9
4.2
2.9
50.0
15.64
13.71
17.56
12.3
4.4
2.8
55.0
13.64
11.91
15.38
12.7
4.7
2.7
60.0
11.95
10.38
13.51
13.1
5.0
2.6
65.0
10.50
9.084
11.92
13.5
5.3
2.5
70.0
9.264
7.978
10.55
13.9
5.6
2.5
75.0
8.201
7.033
9.368
14.2
5.9
2.4
80.0
7.283
6.220
8.346
14.6
6.2
2.3
85.0
6.489
5.520
7.458
14.9
6.6
2.3
90.0
5.799
4.913
6.684
15.3
6.9
2.2
95.0
5.198
4.387
6.008
15.6
7.2
2.2
100.0
4.672
3.928
5.415
15.9
7.6
2.1
105.0
4.211
3.528
4.894
16.2
7.9
2.1
110.0
3.805
3.176
4.434
16.5
8.3
2.0
115.0
3.448
2.868
4.027
16.8
8.6
2.0
120.0
3.131
2.596
3.667
17.1
9.0
1.9
125.0
2.850
2.355
3.346
17.4
9.4
1.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 10 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0470J000
R/T No.
1302
T (
C)
B
25/100
= 3000 K, R
25
= 47
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1584
1329
1839
16.1
2.7
5.9
50.0
1187
1006
1367
15.2
2.7
5.7
45.0
900.0
771.2
1029
14.3
2.6
5.4
40.0
690.2
597.2
783.1
13.5
2.6
5.2
35.0
534.9
467.2
602.6
12.7
2.5
5.0
30.0
418.6
368.9
468.3
11.9
2.5
4.8
25.0
330.7
293.9
367.5
11.1
2.4
4.6
20.0
263.5
236.1
291.0
10.4
2.3
4.5
15.0
211.7
191.1
232.3
9.7
2.3
4.3
10.0
171.4
155.9
187.0
9.1
2.2
4.2
5.0
139.8
128.0
151.6
8.4
2.1
4.0
0.0
114.8
105.8
123.8
7.8
2.0
3.9
5.0
94.91
88.06
101.8
7.2
1.9
3.7
10.0
78.94
73.70
84.19
6.6
1.8
3.6
15.0
66.05
62.02
70.08
6.1
1.7
3.5
20.0
55.57
52.48
58.66
5.6
1.6
3.4
25.0
47.00
44.65
49.35
5.0
1.5
3.3
30.0
39.95
37.74
42.17
5.5
1.7
3.2
35.0
34.13
32.07
36.18
6.0
1.9
3.1
40.0
29.28
27.38
31.18
6.5
2.2
3.0
45.0
25.23
23.48
26.98
6.9
2.4
2.9
50.0
21.83
20.22
23.45
7.4
2.6
2.9
55.0
18.97
17.49
20.45
7.8
2.8
2.8
60.0
16.54
15.18
17.90
8.2
3.0
2.7
65.0
14.48
13.23
15.72
8.6
3.3
2.6
70.0
12.71
11.57
13.86
9.0
3.5
2.6
75.0
11.20
10.15
12.25
9.4
3.8
2.5
80.0
9.901
8.936
10.87
9.8
4.0
2.4
85.0
8.778
7.891
9.665
10.1
4.2
2.4
90.0
7.805
6.989
8.621
10.5
4.5
2.3
95.0
6.958
6.207
7.709
10.8
4.8
2.3
100.0
6.220
5.528
6.911
11.1
5.0
2.2
105.0
5.575
4.938
6.213
11.4
5.3
2.2
110.0
5.010
4.422
5.599
11.7
5.5
2.1
115.0
4.512
3.969
5.056
12.0
5.8
2.1
120.0
4.073
3.571
4.576
12.3
6.1
2.0
125.0
3.685
3.219
4.150
12.6
6.4
2.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 11 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0470K000
R/T No.
1302
T (
C)
B
25/100
= 3000 K, R
25
= 47
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1584
1249
1918
21.1
3.6
5.9
50.0
1187
947.1
1427
20.2
3.6
5.7
45.0
900.0
726.2
1074
19.3
3.6
5.4
40.0
690.2
562.7
817.6
18.5
3.5
5.2
35.0
534.9
440.4
629.3
17.7
3.5
5.0
30.0
418.6
348.0
489.3
16.9
3.5
4.8
25.0
330.7
277.3
384.0
16.1
3.5
4.6
20.0
263.5
222.9
304.1
15.4
3.5
4.5
15.0
211.7
180.5
242.9
14.7
3.4
4.3
10.0
171.4
147.3
195.5
14.1
3.4
4.2
5.0
139.8
121.0
158.6
13.4
3.3
4.0
0.0
114.8
100.1
129.5
12.8
3.3
3.9
5.0
94.91
83.31
106.5
12.2
3.3
3.7
10.0
78.94
69.75
88.14
11.6
3.2
3.6
15.0
66.05
58.72
73.38
11.1
3.2
3.5
20.0
55.57
49.70
61.44
10.6
3.1
3.4
25.0
47.00
42.30
51.70
10.0
3.0
3.3
30.0
39.95
35.74
44.17
10.5
3.3
3.2
35.0
34.13
30.36
37.89
11.0
3.5
3.1
40.0
29.28
25.91
32.65
11.5
3.8
3.0
45.0
25.23
22.22
28.25
11.9
4.1
2.9
50.0
21.83
19.13
24.54
12.4
4.3
2.9
55.0
18.97
16.54
21.40
12.8
4.6
2.8
60.0
16.54
14.35
18.73
13.2
4.9
2.7
65.0
14.48
12.50
16.45
13.6
5.2
2.6
70.0
12.71
10.93
14.49
14.0
5.5
2.6
75.0
11.20
9.590
12.81
14.4
5.7
2.5
80.0
9.901
8.441
11.36
14.8
6.0
2.4
85.0
8.778
7.452
10.10
15.1
6.3
2.4
90.0
7.805
6.599
9.011
15.5
6.6
2.3
95.0
6.958
5.860
8.057
15.8
7.0
2.3
100.0
6.220
5.217
7.222
16.1
7.3
2.2
105.0
5.575
4.659
6.492
16.4
7.6
2.2
110.0
5.010
4.171
5.849
16.7
7.9
2.1
115.0
4.512
3.743
5.282
17.0
8.2
2.1
120.0
4.073
3.367
4.780
17.3
8.6
2.0
125.0
3.685
3.035
4.334
17.6
8.9
2.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 12 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0680J000
R/T No.
1303
T (
C)
B
25/100
= 3050 K, R
25
= 68
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
2337
1956
2718
16.3
2.8
5.7
50.0
1756
1486
2026
15.4
2.8
5.5
45.0
1335
1142
1528
14.5
2.7
5.3
40.0
1026
886.4
1166
13.6
2.6
5.2
35.0
796.4
694.6
898.2
12.8
2.6
5.0
30.0
624.1
549.2
698.9
12.0
2.5
4.8
25.0
493.4
437.9
548.8
11.2
2.4
4.6
20.0
393.3
352.0
434.6
10.5
2.3
4.5
15.0
316.0
285.0
347.0
9.8
2.3
4.3
10.0
255.8
232.4
279.1
9.1
2.2
4.2
5.0
207.7
190.1
225.3
8.5
2.1
4.1
0.0
169.9
156.6
183.3
7.9
2.0
3.9
5.0
139.9
129.8
150.1
7.3
1.9
3.8
10.0
115.9
108.2
123.7
6.7
1.8
3.7
15.0
96.63
90.72
102.5
6.1
1.7
3.6
20.0
80.99
76.48
85.50
5.6
1.6
3.5
25.0
68.00
64.60
71.40
5.0
1.5
3.4
30.0
57.84
54.62
61.05
5.6
1.7
3.3
35.0
49.22
46.25
52.20
6.0
1.9
3.2
40.0
42.09
39.35
44.83
6.5
2.1
3.1
45.0
36.13
33.61
38.65
7.0
2.3
3.0
50.0
31.15
28.84
33.47
7.4
2.5
2.9
55.0
26.95
24.84
29.07
7.9
2.8
2.8
60.0
23.42
21.48
25.36
8.3
3.0
2.8
65.0
20.46
18.68
22.23
8.7
3.2
2.7
70.0
17.93
16.31
19.56
9.1
3.5
2.6
75.0
15.78
14.29
17.28
9.5
3.7
2.5
80.0
13.94
12.57
15.31
9.8
4.0
2.5
85.0
12.34
11.08
13.60
10.2
4.2
2.4
90.0
10.96
9.804
12.11
10.5
4.5
2.4
95.0
9.745
8.684
10.81
10.9
4.7
2.3
100.0
8.687
7.713
9.662
11.2
5.0
2.2
105.0
7.792
6.892
8.691
11.5
5.3
2.2
110.0
7.008
6.177
7.839
11.9
5.6
2.1
115.0
6.307
5.540
7.074
12.2
5.9
2.1
120.0
5.690
4.981
6.399
12.5
6.1
2.0
125.0
5.150
4.493
5.807
12.8
6.4
2.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 13 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0680K000
R/T No.
1303
T (
C)
B
25/100
= 3050 K, R
25
= 68
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
2337
1839
2834
21.3
3.7
5.7
50.0
1756
1399
2114
20.4
3.7
5.5
45.0
1335
1075
1595
19.5
3.6
5.3
40.0
1026
835.1
1217
18.6
3.6
5.2
35.0
796.4
654.8
938.1
17.8
3.6
5.0
30.0
624.1
518.0
730.1
17.0
3.5
4.8
25.0
493.4
413.3
573.4
16.2
3.5
4.6
20.0
393.3
332.3
454.3
15.5
3.5
4.5
15.0
316.0
269.2
362.8
14.8
3.4
4.3
10.0
255.8
219.6
291.9
14.1
3.4
4.2
5.0
207.7
179.7
235.7
13.5
3.3
4.1
0.0
169.9
148.1
191.8
12.9
3.3
3.9
5.0
139.9
122.8
157.1
12.3
3.2
3.8
10.0
115.9
102.4
129.5
11.7
3.2
3.7
15.0
96.63
85.89
107.4
11.1
3.1
3.6
20.0
80.99
72.43
89.55
10.6
3.0
3.5
25.0
68.00
61.20
74.80
10.0
3.0
3.4
30.0
57.84
51.73
63.94
10.6
3.2
3.3
35.0
49.22
43.79
54.66
11.0
3.5
3.2
40.0
42.09
37.24
46.94
11.5
3.7
3.1
45.0
36.13
31.80
40.46
12.0
4.0
3.0
50.0
31.15
27.28
35.02
12.4
4.3
2.9
55.0
26.95
23.49
30.42
12.9
4.5
2.8
60.0
23.42
20.31
26.53
13.3
4.8
2.8
65.0
20.46
17.66
23.25
13.7
5.1
2.7
70.0
17.93
15.41
20.46
14.1
5.4
2.6
75.0
15.78
13.50
18.07
14.5
5.7
2.5
80.0
13.94
11.87
16.01
14.8
6.0
2.5
85.0
12.34
10.47
14.22
15.2
6.3
2.4
90.0
10.96
9.256
12.66
15.5
6.6
2.4
95.0
9.745
8.197
11.29
15.9
6.9
2.3
100.0
8.687
7.278
10.10
16.2
7.3
2.2
105.0
7.792
6.503
9.081
16.5
7.6
2.2
110.0
7.008
5.826
8.189
16.9
7.9
2.1
115.0
6.307
5.224
7.390
17.2
8.3
2.1
120.0
5.690
4.696
6.684
17.5
8.6
2.0
125.0
5.150
4.236
6.065
17.8
9.0
2.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 14 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0101J000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 100
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
4213
3503
4923
16.9
2.7
6.1
50.0
3113
2619
3607
15.9
2.7
5.9
45.0
2327
1980
2675
14.9
2.6
5.7
40.0
1759
1512
2006
14.0
2.6
5.5
35.0
1344
1167
1521
13.2
2.5
5.3
30.0
1037
908.7
1164
12.3
2.4
5.1
25.0
810.1
716.6
903.5
11.5
2.3
4.9
20.0
638.6
569.8
707.4
10.8
2.3
4.8
15.0
503.6
453.1
554.2
10.0
2.2
4.6
10.0
400.7
363.3
438.1
9.3
2.1
4.4
5.0
322.2
294.3
350.0
8.7
2.0
4.3
0.0
261.0
240.1
281.8
8.0
1.9
4.2
5.0
212.6
196.9
228.3
7.4
1.8
4.0
10.0
174.4
162.6
186.2
6.8
1.7
3.9
15.0
144.2
135.3
153.0
6.2
1.6
3.8
20.0
119.9
113.2
126.6
5.6
1.5
3.7
25.0
100.00
95.00
105.0
5.0
1.4
3.5
30.0
84.18
79.49
88.88
5.6
1.6
3.4
35.0
71.08
66.75
75.41
6.1
1.8
3.3
40.0
60.32
56.34
64.29
6.6
2.0
3.2
45.0
51.42
47.78
55.06
7.1
2.2
3.1
50.0
44.04
40.72
47.36
7.5
2.5
3.1
55.0
37.82
34.80
40.85
8.0
2.7
3.0
60.0
32.64
29.88
35.39
8.4
2.9
2.9
65.0
28.33
25.82
30.84
8.9
3.2
2.8
70.0
24.70
22.41
26.99
9.3
3.4
2.7
75.0
21.57
19.49
23.66
9.7
3.6
2.7
80.0
18.91
17.00
20.81
10.1
3.9
2.6
85.0
16.65
14.91
18.39
10.4
4.1
2.5
90.0
14.71
13.12
16.30
10.8
4.4
2.5
95.0
13.02
11.57
14.48
11.2
4.7
2.4
100.0
11.56
10.23
12.89
11.5
4.9
2.3
105.0
10.30
9.079
11.52
11.9
5.2
2.3
110.0
9.204
8.082
10.33
12.2
5.5
2.2
115.0
8.244
7.212
9.276
12.5
5.8
2.2
120.0
7.403
6.454
8.353
12.8
6.0
2.1
125.0
6.670
5.794
7.546
13.1
6.3
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 15 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0101K000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 100
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
4213
3292
5134
21.9
3.6
6.1
50.0
3113
2463
3763
20.9
3.5
5.9
45.0
2327
1863
2791
19.9
3.5
5.7
40.0
1759
1425
2094
19.0
3.5
5.5
35.0
1344
1100
1588
18.2
3.4
5.3
30.0
1037
856.9
1216
17.3
3.4
5.1
25.0
810.1
676.1
944.0
16.5
3.4
4.9
20.0
638.6
537.8
739.3
15.8
3.3
4.8
15.0
503.6
427.9
579.4
15.0
3.3
4.6
10.0
400.7
343.2
458.1
14.3
3.2
4.4
5.0
322.2
278.2
366.2
13.7
3.2
4.3
0.0
261.0
227.1
294.9
13.0
3.1
4.2
5.0
212.6
186.3
238.9
12.4
3.1
4.0
10.0
174.4
153.9
194.9
11.8
3.0
3.9
15.0
144.2
128.1
160.2
11.2
3.0
3.8
20.0
119.9
107.2
132.6
10.6
2.9
3.7
25.0
100.00
90.00
110.0
10.0
2.8
3.5
30.0
84.18
75.28
93.09
10.6
3.1
3.4
35.0
71.08
63.19
78.97
11.1
3.3
3.3
40.0
60.32
53.32
67.31
11.6
3.6
3.2
45.0
51.42
45.21
57.63
12.1
3.8
3.1
50.0
44.04
38.51
49.56
12.5
4.1
3.1
55.0
37.82
32.91
42.74
13.0
4.4
3.0
60.0
32.64
28.25
37.02
13.4
4.6
2.9
65.0
28.33
24.41
32.26
13.9
4.9
2.8
70.0
24.70
21.17
28.22
14.3
5.2
2.7
75.0
21.57
18.41
24.74
14.7
5.5
2.7
80.0
18.91
16.06
21.76
15.1
5.8
2.6
85.0
16.65
14.08
19.22
15.4
6.1
2.5
90.0
14.71
12.38
17.04
15.8
6.4
2.5
95.0
13.02
10.92
15.13
16.2
6.7
2.4
100.0
11.56
9.650
13.47
16.5
7.1
2.3
105.0
10.30
8.564
12.04
16.9
7.4
2.3
110.0
9.204
7.621
10.79
17.2
7.7
2.2
115.0
8.244
6.800
9.688
17.5
8.1
2.2
120.0
7.403
6.083
8.724
17.8
8.4
2.1
125.0
6.670
5.460
7.880
18.1
8.8
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 16 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0151J000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 150
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
6320
5254
7385
16.9
2.7
6.1
50.0
4669
3928
5410
15.9
2.7
5.9
45.0
3491
2970
4012
14.9
2.6
5.7
40.0
2639
2269
3009
14.0
2.6
5.5
35.0
2016
1750
2281
13.2
2.5
5.3
30.0
1555
1363
1747
12.3
2.4
5.1
25.0
1215
1075
1355
11.5
2.3
4.9
20.0
957.8
854.7
1061
10.8
2.3
4.8
15.0
755.5
679.6
831.3
10.0
2.2
4.6
10.0
601.0
544.9
657.1
9.3
2.1
4.4
5.0
483.3
441.4
525.1
8.7
2.0
4.3
0.0
391.5
360.2
422.8
8.0
1.9
4.2
5.0
318.9
295.4
342.4
7.4
1.8
4.0
10.0
261.6
243.9
279.2
6.8
1.7
3.9
15.0
216.2
202.9
229.6
6.2
1.6
3.8
20.0
179.8
169.7
189.9
5.6
1.5
3.7
25.0
150.0
142.5
157.5
5.0
1.4
3.5
30.0
126.3
119.2
133.3
5.6
1.6
3.4
35.0
106.6
100.1
113.1
6.1
1.8
3.3
40.0
90.48
84.51
96.44
6.6
2.0
3.2
45.0
77.13
71.67
82.59
7.1
2.2
3.1
50.0
66.05
61.07
71.04
7.5
2.5
3.1
55.0
56.74
52.20
61.27
8.0
2.7
3.0
60.0
48.95
44.83
53.08
8.4
2.9
2.9
65.0
42.50
38.73
46.26
8.9
3.2
2.8
70.0
37.05
33.61
40.48
9.3
3.4
2.7
75.0
32.36
29.23
35.49
9.7
3.6
2.7
80.0
28.36
25.51
31.22
10.1
3.9
2.6
85.0
24.97
22.37
27.58
10.4
4.1
2.5
90.0
22.06
19.68
24.45
10.8
4.4
2.5
95.0
19.53
17.35
21.71
11.2
4.7
2.4
100.0
17.34
15.34
19.34
11.5
4.9
2.3
105.0
15.45
13.62
17.28
11.9
5.2
2.3
110.0
13.81
12.12
15.49
12.2
5.5
2.2
115.0
12.37
10.82
13.91
12.5
5.8
2.2
120.0
11.11
9.680
12.53
12.8
6.0
2.1
125.0
10.01
8.691
11.32
13.1
6.3
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 17 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0151K000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 150
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
6320
4938
7701
21.9
3.6
6.1
50.0
4669
3695
5644
20.9
3.5
5.9
45.0
3491
2795
4187
19.9
3.5
5.7
40.0
2639
2137
3141
19.0
3.5
5.5
35.0
2016
1650
2382
18.2
3.4
5.3
30.0
1555
1285
1824
17.3
3.4
5.1
25.0
1215
1014
1416
16.5
3.4
4.9
20.0
957.8
806.8
1109
15.8
3.3
4.8
15.0
755.5
641.8
869.1
15.0
3.3
4.6
10.0
601.0
514.9
687.1
14.3
3.2
4.4
5.0
483.3
417.3
549.2
13.7
3.2
4.3
0.0
391.5
340.6
442.3
13.0
3.1
4.2
5.0
318.9
279.5
358.3
12.4
3.1
4.0
10.0
261.6
230.8
292.3
11.8
3.0
3.9
15.0
216.2
192.1
240.4
11.2
3.0
3.8
20.0
179.8
160.7
198.9
10.6
2.9
3.7
25.0
150.0
135.0
165.0
10.0
2.8
3.5
30.0
126.3
112.9
139.6
10.6
3.1
3.4
35.0
106.6
94.79
118.4
11.1
3.3
3.3
40.0
90.48
79.99
101.0
11.6
3.6
3.2
45.0
77.13
67.82
86.44
12.1
3.8
3.1
50.0
66.05
57.77
74.34
12.5
4.1
3.1
55.0
56.74
49.36
64.11
13.0
4.4
3.0
60.0
48.95
42.38
55.53
13.4
4.6
2.9
65.0
42.50
36.61
48.39
13.9
4.9
2.8
70.0
37.05
31.76
42.33
14.3
5.2
2.7
75.0
32.36
27.61
37.11
14.7
5.5
2.7
80.0
28.36
24.09
32.63
15.1
5.8
2.6
85.0
24.97
21.12
28.83
15.4
6.1
2.5
90.0
22.06
18.57
25.55
15.8
6.4
2.5
95.0
19.53
16.37
22.69
16.2
6.7
2.4
100.0
17.34
14.48
20.21
16.5
7.1
2.3
105.0
15.45
12.85
18.06
16.9
7.4
2.3
110.0
13.81
11.43
16.18
17.2
7.7
2.2
115.0
12.37
10.20
14.53
17.5
8.1
2.2
120.0
11.11
9.125
13.09
17.8
8.4
2.1
125.0
10.01
8.190
11.82
18.1
8.8
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 18 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0221J000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 220
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
9269
7706
10831
16.9
2.7
6.1
50.0
6848
5761
7935
15.9
2.7
5.9
45.0
5120
4356
5884
14.9
2.6
5.7
40.0
3870
3327
4413
14.0
2.6
5.5
35.0
2956
2567
3345
13.2
2.5
5.3
30.0
2280
1999
2562
12.3
2.4
5.1
25.0
1782
1576
1988
11.5
2.3
4.9
20.0
1405
1253
1556
10.8
2.3
4.8
15.0
1108
996.8
1219
10.0
2.2
4.6
10.0
881.5
799.2
963.7
9.3
2.1
4.4
5.0
708.8
647.5
770.1
8.7
2.0
4.3
0.0
574.1
528.2
620.1
8.0
1.9
4.2
5.0
467.7
433.3
502.2
7.4
1.8
4.0
10.0
383.6
357.7
409.6
6.8
1.7
3.9
15.0
317.1
297.6
336.7
6.2
1.6
3.8
20.0
263.7
249.0
278.5
5.6
1.5
3.7
25.0
220.0
209.0
231.0
5.0
1.4
3.5
30.0
185.2
174.9
195.5
5.6
1.6
3.4
35.0
156.4
146.8
165.9
6.1
1.8
3.3
40.0
132.7
123.9
141.4
6.6
2.0
3.2
45.0
113.1
105.1
121.1
7.1
2.2
3.1
50.0
96.88
89.57
104.2
7.5
2.5
3.1
55.0
83.21
76.56
89.86
8.0
2.7
3.0
60.0
71.80
65.74
77.85
8.4
2.9
2.9
65.0
62.33
56.81
67.85
8.9
3.2
2.8
70.0
54.33
49.30
59.37
9.3
3.4
2.7
75.0
47.46
42.87
52.05
9.7
3.6
2.7
80.0
41.60
37.41
45.78
10.1
3.9
2.6
85.0
36.63
32.80
40.45
10.4
4.1
2.5
90.0
32.36
28.86
35.86
10.8
4.4
2.5
95.0
28.65
25.45
31.85
11.2
4.7
2.4
100.0
25.43
22.50
28.36
11.5
4.9
2.3
105.0
22.66
19.97
25.35
11.9
5.2
2.3
110.0
20.25
17.78
22.72
12.2
5.5
2.2
115.0
18.14
15.87
20.41
12.5
5.8
2.2
120.0
16.29
14.20
18.38
12.8
6.0
2.1
125.0
14.67
12.75
16.60
13.1
6.3
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 19 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0221K000
R/T No.
1305
T (
C)
B
25/100
= 3200 K, R
25
= 220
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
9269
7243
11295
21.9
3.6
6.1
50.0
6848
5419
8278
20.9
3.5
5.9
45.0
5120
4100
6140
19.9
3.5
5.7
40.0
3870
3134
4607
19.0
3.5
5.5
35.0
2956
2419
3493
18.2
3.4
5.3
30.0
2280
1885
2676
17.3
3.4
5.1
25.0
1782
1487
2077
16.5
3.4
4.9
20.0
1405
1183
1626
15.8
3.3
4.8
15.0
1108
941.4
1275
15.0
3.3
4.6
10.0
881.5
755.1
1008
14.3
3.2
4.4
5.0
708.8
612.0
805.5
13.7
3.2
4.3
0.0
574.1
499.5
648.8
13.0
3.1
4.2
5.0
467.7
409.9
525.6
12.4
3.1
4.0
10.0
383.6
338.5
428.7
11.8
3.0
3.9
15.0
317.1
281.7
352.5
11.2
3.0
3.8
20.0
263.7
235.8
291.7
10.6
2.9
3.7
25.0
220.0
198.0
242.0
10.0
2.8
3.5
30.0
185.2
165.6
204.8
10.6
3.1
3.4
35.0
156.4
139.0
173.7
11.1
3.3
3.3
40.0
132.7
117.3
148.1
11.6
3.6
3.2
45.0
113.1
99.46
126.8
12.1
3.8
3.1
50.0
96.88
84.73
109.0
12.5
4.1
3.1
55.0
83.21
72.40
94.02
13.0
4.4
3.0
60.0
71.80
62.15
81.44
13.4
4.6
2.9
65.0
62.33
53.69
70.97
13.9
4.9
2.8
70.0
54.33
46.58
62.09
14.3
5.2
2.7
75.0
47.46
40.50
54.42
14.7
5.5
2.7
80.0
41.60
35.33
47.86
15.1
5.8
2.6
85.0
36.63
30.97
42.29
15.4
6.1
2.5
90.0
32.36
27.24
37.48
15.8
6.4
2.5
95.0
28.65
24.01
33.28
16.2
6.7
2.4
100.0
25.43
21.23
29.63
16.5
7.1
2.3
105.0
22.66
18.84
26.48
16.9
7.4
2.3
110.0
20.25
16.77
23.73
17.2
7.7
2.2
115.0
18.14
14.96
21.31
17.5
8.1
2.2
120.0
16.29
13.38
19.19
17.8
8.4
2.1
125.0
14.67
12.01
17.34
18.1
8.8
2.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 20 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0331J000
R/T No.
1306
T (
C)
B
25/100
= 3450 K, R
25
= 330
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
16479
13549
19409
17.8
2.8
6.3
50.0
12091
10070
14113
16.7
2.7
6.1
45.0
8969
7561
10378
15.7
2.7
5.9
40.0
6722
5732
7712
14.7
2.6
5.7
35.0
5087
4385
5789
13.8
2.5
5.5
30.0
3886
3384
4387
12.9
2.4
5.3
25.0
2993
2633
3354
12.0
2.3
5.1
20.0
2326
2065
2587
11.2
2.3
5.0
15.0
1821
1631
2011
10.4
2.2
4.8
10.0
1437
1298
1576
9.7
2.1
4.7
5.0
1142
1040
1244
8.9
2.0
4.5
0.0
914.3
839.0
989.5
8.2
1.9
4.4
5.0
736.4
680.8
792.0
7.5
1.8
4.3
10.0
597.2
556.1
638.4
6.9
1.7
4.1
15.0
487.1
456.7
517.6
6.3
1.6
4.0
20.0
399.8
377.3
422.4
5.6
1.4
3.9
25.0
330.0
313.5
346.5
5.0
1.3
3.8
30.0
273.8
258.5
289.2
5.6
1.5
3.7
35.0
228.4
214.3
242.5
6.2
1.7
3.6
40.0
191.5
178.7
204.4
6.7
1.9
3.5
45.0
161.4
149.7
173.0
7.2
2.1
3.4
50.0
136.6
126.0
147.2
7.7
2.4
3.3
55.0
116.1
106.6
125.7
8.2
2.6
3.2
60.0
99.20
90.57
107.8
8.7
2.8
3.1
65.0
85.07
77.28
92.86
9.2
3.0
3.0
70.0
73.25
66.22
80.28
9.6
3.2
3.0
75.0
63.32
56.97
69.68
10.0
3.5
2.9
80.0
54.94
49.19
60.68
10.5
3.7
2.8
85.0
47.84
42.65
53.04
10.9
4.0
2.7
90.0
41.81
37.10
46.52
11.3
4.2
2.7
95.0
36.66
32.39
40.93
11.7
4.5
2.6
100.0
32.25
28.37
36.12
12.0
4.7
2.5
105.0
28.46
24.93
31.98
12.4
5.0
2.5
110.0
25.19
21.98
28.40
12.8
5.3
2.4
115.0
22.36
19.43
25.29
13.1
5.6
2.4
120.0
19.91
17.23
22.58
13.4
5.8
2.3
125.0
17.77
15.32
20.22
13.8
6.1
2.2
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 21 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0331K000
R/T No.
1306
T (
C)
B
25/100
= 3450 K, R
25
= 330
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
16479
12725
20232
22.8
3.6
6.3
50.0
12091
9465
14717
21.7
3.6
6.1
45.0
8969
7113
10826
20.7
3.5
5.9
40.0
6722
5396
8048
19.7
3.5
5.7
35.0
5087
4131
6044
18.8
3.4
5.5
30.0
3886
3190
4581
17.9
3.4
5.3
25.0
2993
2483
3503
17.0
3.3
5.1
20.0
2326
1949
2704
16.2
3.3
5.0
15.0
1821
1540
2102
15.4
3.2
4.8
10.0
1437
1227
1648
14.7
3.1
4.7
5.0
1142
983.0
1301
13.9
3.1
4.5
0.0
914.3
793.3
1035
13.2
3.0
4.4
5.0
736.4
644.0
828.8
12.5
2.9
4.3
10.0
597.2
526.2
668.2
11.9
2.9
4.1
15.0
487.1
432.3
542.0
11.3
2.8
4.0
20.0
399.8
357.3
442.4
10.6
2.7
3.9
25.0
330.0
297.0
363.0
10.0
2.6
3.8
30.0
273.8
244.8
302.9
10.6
2.9
3.7
35.0
228.4
202.9
254.0
11.2
3.1
3.6
40.0
191.5
169.1
214.0
11.7
3.4
3.5
45.0
161.4
141.6
181.1
12.2
3.6
3.4
50.0
136.6
119.2
154.0
12.7
3.9
3.3
55.0
116.1
100.8
131.5
13.2
4.1
3.2
60.0
99.20
85.61
112.8
13.7
4.4
3.1
65.0
85.07
73.03
97.12
14.2
4.7
3.0
70.0
73.25
62.55
83.95
14.6
4.9
3.0
75.0
63.32
53.80
72.84
15.0
5.2
2.9
80.0
54.94
46.45
63.43
15.5
5.5
2.8
85.0
47.84
40.25
55.44
15.9
5.8
2.7
90.0
41.81
35.01
48.61
16.3
6.1
2.7
95.0
36.66
30.56
42.76
16.7
6.4
2.6
100.0
32.25
26.76
37.74
17.0
6.7
2.5
105.0
28.46
23.51
33.41
17.4
7.0
2.5
110.0
25.19
20.72
29.66
17.8
7.4
2.4
115.0
22.36
18.31
26.41
18.1
7.7
2.4
120.0
19.91
16.24
23.58
18.4
8.0
2.3
125.0
17.77
14.44
21.11
18.8
8.4
2.2
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 22 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0471J000
R/T No.
1306
T (
C)
B
25/100
= 3450 K, R
25
= 470
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
23470
19297
27642
17.8
2.8
6.3
50.0
17221
14342
20100
16.7
2.7
6.1
45.0
12774
10769
14780
15.7
2.7
5.9
40.0
9574
8164
10984
14.7
2.6
5.7
35.0
7246
6246
8245
13.8
2.5
5.5
30.0
5534
4820
6248
12.9
2.4
5.3
25.0
4263
3749
4776
12.0
2.3
5.1
20.0
3313
2942
3685
11.2
2.3
5.0
15.0
2594
2323
2864
10.4
2.2
4.8
10.0
2047
1849
2245
9.7
2.1
4.7
5.0
1627
1481
1772
8.9
2.0
4.5
0.0
1302
1195
1409
8.2
1.9
4.4
5.0
1049
969.7
1128
7.5
1.8
4.3
10.0
850.6
792.0
909.2
6.9
1.7
4.1
15.0
693.8
650.4
737.2
6.3
1.6
4.0
20.0
569.5
537.3
601.6
5.6
1.4
3.9
25.0
470.0
446.5
493.5
5.0
1.3
3.8
30.0
390.0
368.1
412.0
5.6
1.5
3.7
35.0
325.3
305.2
345.4
6.2
1.7
3.6
40.0
272.8
254.5
291.1
6.7
1.9
3.5
45.0
229.8
213.2
246.4
7.2
2.1
3.4
50.0
194.6
179.5
209.6
7.7
2.4
3.3
55.0
165.4
151.8
179.0
8.2
2.6
3.2
60.0
141.3
129.0
153.6
8.7
2.8
3.1
65.0
121.2
110.1
132.3
9.2
3.0
3.0
70.0
104.3
94.31
114.3
9.6
3.2
3.0
75.0
90.19
81.14
99.24
10.0
3.5
2.9
80.0
78.25
70.07
86.43
10.5
3.7
2.8
85.0
68.14
60.74
75.55
10.9
4.0
2.7
90.0
59.54
52.84
66.25
11.3
4.2
2.7
95.0
52.21
46.13
58.29
11.7
4.5
2.6
100.0
45.93
40.40
51.45
12.0
4.7
2.5
105.0
40.53
35.51
45.55
12.4
5.0
2.5
110.0
35.87
31.30
40.45
12.8
5.3
2.4
115.0
31.85
27.68
36.02
13.1
5.6
2.4
120.0
28.35
24.54
32.16
13.4
5.8
2.3
125.0
25.31
21.83
28.80
13.8
6.1
2.2
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 23 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0471K000
R/T No.
1306
T (
C)
B
25/100
= 3450 K, R
25
= 470
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
23470
18123
28816
22.8
3.6
6.3
50.0
17221
13481
20961
21.7
3.6
6.1
45.0
12774
10130
15419
20.7
3.5
5.9
40.0
9574
7685
11463
19.7
3.5
5.7
35.0
7246
5884
8607
18.8
3.4
5.5
30.0
5534
4543
6525
17.9
3.4
5.3
25.0
4263
3536
4989
17.0
3.3
5.1
20.0
3313
2776
3851
16.2
3.3
5.0
15.0
2594
2194
2994
15.4
3.2
4.8
10.0
2047
1747
2348
14.7
3.1
4.7
5.0
1627
1400
1853
13.9
3.1
4.5
0.0
1302
1130
1474
13.2
3.0
4.4
5.0
1049
917.2
1180
12.5
2.9
4.3
10.0
850.6
749.5
951.7
11.9
2.9
4.1
15.0
693.8
615.7
771.9
11.3
2.8
4.0
20.0
569.5
508.9
630.1
10.6
2.7
3.9
25.0
470.0
423.0
517.0
10.0
2.6
3.8
30.0
390.0
348.6
431.5
10.6
2.9
3.7
35.0
325.3
289.0
361.7
11.2
3.1
3.6
40.0
272.8
240.8
304.8
11.7
3.4
3.5
45.0
229.8
201.7
257.9
12.2
3.6
3.4
50.0
194.6
169.8
219.3
12.7
3.9
3.3
55.0
165.4
143.5
187.3
13.2
4.1
3.2
60.0
141.3
121.9
160.6
13.7
4.4
3.1
65.0
121.2
104.0
138.3
14.2
4.7
3.0
70.0
104.3
89.09
119.6
14.6
4.9
3.0
75.0
90.19
76.63
103.7
15.0
5.2
2.9
80.0
78.25
66.15
90.34
15.5
5.5
2.8
85.0
68.14
57.33
78.95
15.9
5.8
2.7
90.0
59.54
49.86
69.23
16.3
6.1
2.7
95.0
52.21
43.52
60.91
16.7
6.4
2.6
100.0
45.93
38.11
53.75
17.0
6.7
2.5
105.0
40.53
33.48
47.58
17.4
7.0
2.5
110.0
35.87
29.50
42.24
17.8
7.4
2.4
115.0
31.85
26.08
37.61
18.1
7.7
2.4
120.0
28.35
23.12
33.58
18.4
8.0
2.3
125.0
25.31
20.56
30.06
18.8
8.4
2.2
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 24 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0102J000
R/T No.
1011
T (
C)
B
25/100
= 3730 K, R
25
= 1000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
70014
56842
83186
18.8
2.7
6.9
50.0
49906
41090
58721
17.7
2.7
6.6
45.0
36015
30049
41981
16.6
2.6
6.4
40.0
26296
22216
30375
15.5
2.5
6.2
35.0
19411
16595
22227
14.5
2.4
6.0
30.0
14479
12518
16439
13.5
2.3
5.8
25.0
10903
9528
12278
12.6
2.3
5.6
20.0
8292
7320
9264
11.7
2.2
5.4
15.0
6359
5668
7050
10.9
2.1
5.2
10.0
4920
4426
5415
10.0
2.0
5.1
5.0
3828
3474
4182
9.2
1.9
4.9
0.0
3003
2748
3258
8.5
1.8
4.8
5.0
2377
2193
2562
7.7
1.7
4.6
10.0
1896
1762
2029
7.0
1.6
4.5
15.0
1521
1424
1617
6.4
1.5
4.3
20.0
1228
1158
1298
5.7
1.4
4.2
25.0
1000.0
950.0
1050
5.0
1.2
4.1
30.0
817.8
771.4
864.2
5.7
1.4
4.0
35.0
673.4
631.2
715.6
6.3
1.6
3.9
40.0
557.5
519.3
595.6
6.8
1.8
3.8
45.0
463.6
429.2
497.9
7.4
2.0
3.7
50.0
387.4
356.6
418.2
8.0
2.2
3.6
55.0
323.7
296.2
351.1
8.5
2.5
3.5
60.0
272.0
247.5
296.5
9.0
2.7
3.4
65.0
230.4
208.5
252.3
9.5
2.9
3.3
70.0
196.0
176.5
215.6
10.0
3.1
3.2
75.0
167.4
149.9
184.8
10.4
3.3
3.1
80.0
143.4
127.8
159.0
10.9
3.6
3.0
85.0
123.5
109.5
137.5
11.3
3.8
3.0
90.0
106.7
94.13
119.2
11.8
4.1
2.9
95.0
92.73
81.43
104.0
12.2
4.3
2.8
100.0
80.90
70.71
91.09
12.6
4.6
2.8
105.0
70.62
61.44
79.79
13.0
4.8
2.7
110.0
61.83
53.56
70.10
13.4
5.1
2.6
115.0
54.28
46.82
61.75
13.8
5.4
2.6
120.0
47.79
41.04
54.54
14.1
5.6
2.5
125.0
42.25
36.13
48.36
14.5
5.9
2.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 25 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0102K000
R/T No.
1011
T (
C)
B
25/100
= 3730 K, R
25
= 1000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
70014
53341
86686
23.8
3.5
6.9
50.0
49906
38595
61216
22.7
3.4
6.6
45.0
36015
28248
43782
21.6
3.4
6.4
40.0
26296
20901
31690
20.5
3.3
6.2
35.0
19411
15625
23197
19.5
3.3
6.0
30.0
14479
11794
17163
18.5
3.2
5.8
25.0
10903
8983
12823
17.6
3.2
5.6
20.0
8292
6906
9679
16.7
3.1
5.4
15.0
6359
5350
7368
15.9
3.0
5.2
10.0
4920
4180
5661
15.0
3.0
5.1
5.0
3828
3282
4373
14.2
2.9
4.9
0.0
3003
2598
3408
13.5
2.8
4.8
5.0
2377
2074
2680
12.7
2.8
4.6
10.0
1896
1668
2124
12.0
2.7
4.5
15.0
1521
1348
1693
11.4
2.6
4.3
20.0
1228
1097
1359
10.7
2.5
4.2
25.0
1000.0
900.0
1100
10.0
2.4
4.1
30.0
817.8
730.5
905.0
10.7
2.7
4.0
35.0
673.4
597.5
749.3
11.3
2.9
3.9
40.0
557.5
491.4
623.5
11.8
3.2
3.8
45.0
463.6
406.0
521.1
12.4
3.4
3.7
50.0
387.4
337.2
437.6
13.0
3.6
3.6
55.0
323.7
280.0
367.3
13.5
3.9
3.5
60.0
272.0
233.9
310.1
14.0
4.2
3.4
65.0
230.4
197.0
263.8
14.5
4.4
3.3
70.0
196.0
166.7
225.4
15.0
4.7
3.2
75.0
167.4
141.5
193.2
15.4
5.0
3.1
80.0
143.4
120.6
166.2
15.9
5.2
3.0
85.0
123.5
103.3
143.6
16.3
5.5
3.0
90.0
106.7
88.80
124.6
16.8
5.8
2.9
95.0
92.73
76.80
108.7
17.2
6.1
2.8
100.0
80.90
66.67
95.14
17.6
6.4
2.8
105.0
70.62
57.91
83.32
18.0
6.7
2.7
110.0
61.83
50.46
73.19
18.4
7.0
2.6
115.0
54.28
44.10
64.46
18.8
7.3
2.6
120.0
47.79
38.66
56.93
19.1
7.6
2.5
125.0
42.25
34.02
50.48
19.5
7.9
2.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 26 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0152J000
R/T No.
1013
T (
C)
B
25/100
= 3900 K, R
25
= 1500
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
115930
93390
138460
19.4
2.8
6.9
50.0
82407
67376
97437
18.2
2.7
6.7
45.0
59260
49132
69387
17.1
2.6
6.5
40.0
43083
36194
49972
16.0
2.5
6.3
35.0
31648
26921
36375
14.9
2.5
6.1
30.0
23478
20208
26747
13.9
2.4
5.9
25.0
17572
15295
19849
13.0
2.3
5.7
20.0
13281
11684
14878
12.0
2.2
5.5
15.0
10115
8989
11241
11.1
2.1
5.4
10.0
7772
6974
8570
10.3
2.0
5.2
5.0
6015
5447
6583
9.4
1.9
5.0
0.0
4693
4287
5098
8.6
1.8
4.9
5.0
3685
3395
3975
7.9
1.7
4.8
10.0
2916
2708
3124
7.1
1.5
4.6
15.0
2321
2172
2470
6.4
1.4
4.5
20.0
1860
1754
1967
5.7
1.3
4.4
25.0
1500
1425
1575
5.0
1.2
4.3
30.0
1217
1147
1286
5.7
1.4
4.1
35.0
992.2
929.4
1055
6.3
1.6
4.0
40.0
813.8
757.4
870.2
6.9
1.8
3.9
45.0
670.9
620.5
721.3
7.5
2.0
3.8
50.0
556.0
511.0
601.0
8.1
2.2
3.7
55.0
463.0
423.0
503.0
8.6
2.4
3.6
60.0
387.4
351.8
422.9
9.2
2.6
3.5
65.0
325.6
294.0
357.2
9.7
2.8
3.4
70.0
274.9
246.8
302.9
10.2
3.0
3.3
75.0
233.0
208.1
257.9
10.7
3.3
3.3
80.0
198.4
176.2
220.5
11.2
3.5
3.2
85.0
169.5
149.8
189.2
11.6
3.7
3.1
90.0
145.4
127.9
163.0
12.1
4.0
3.0
95.0
125.2
109.6
140.9
12.5
4.2
3.0
100.0
108.2
94.21
122.2
12.9
4.5
2.9
105.0
93.84
81.31
106.4
13.4
4.7
2.8
110.0
81.64
70.41
92.87
13.8
5.0
2.8
115.0
71.26
61.18
81.35
14.1
5.3
2.7
120.0
62.39
53.32
71.46
14.5
5.5
2.6
125.0
54.80
46.63
62.97
14.9
5.8
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 27 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0152K000
R/T No.
1013
T (
C)
B
25/100
= 3900 K, R
25
= 1500
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
115930
87594
144260
24.4
3.5
6.9
50.0
82407
63256
101560
23.2
3.5
6.7
45.0
59260
46169
72350
22.1
3.4
6.5
40.0
43083
34040
52126
21.0
3.3
6.3
35.0
31648
25338
37958
19.9
3.3
6.1
30.0
23478
19034
27921
18.9
3.2
5.9
25.0
17572
14417
20727
18.0
3.1
5.7
20.0
13281
11020
15542
17.0
3.1
5.5
15.0
10115
8483
11747
16.1
3.0
5.4
10.0
7772
6585
8959
15.3
2.9
5.2
5.0
6015
5146
6883
14.4
2.9
5.0
0.0
4693
4052
5333
13.6
2.8
4.9
5.0
3685
3211
4160
12.9
2.7
4.8
10.0
2916
2562
3269
12.1
2.6
4.6
15.0
2321
2056
2586
11.4
2.5
4.5
20.0
1860
1661
2060
10.7
2.5
4.4
25.0
1500
1350
1650
10.0
2.4
4.3
30.0
1217
1086
1347
10.7
2.6
4.1
35.0
992.2
879.8
1105
11.3
2.8
4.0
40.0
813.8
716.7
910.9
11.9
3.0
3.9
45.0
670.9
586.9
754.9
12.5
3.3
3.8
50.0
556.0
483.2
628.8
13.1
3.5
3.7
55.0
463.0
399.8
526.1
13.6
3.8
3.6
60.0
387.4
332.5
442.3
14.2
4.0
3.5
65.0
325.6
277.8
373.4
14.7
4.3
3.4
70.0
274.9
233.1
316.6
15.2
4.5
3.3
75.0
233.0
196.5
269.6
15.7
4.8
3.3
80.0
198.4
166.3
230.4
16.2
5.1
3.2
85.0
169.5
141.3
197.7
16.6
5.4
3.1
90.0
145.4
120.6
170.3
17.1
5.6
3.0
95.0
125.2
103.3
147.2
17.5
5.9
3.0
100.0
108.2
88.80
127.6
17.9
6.2
2.9
105.0
93.84
76.62
111.1
18.4
6.5
2.8
110.0
81.64
66.33
96.95
18.8
6.8
2.8
115.0
71.26
57.62
84.91
19.1
7.1
2.7
120.0
62.39
50.20
74.58
19.5
7.4
2.6
125.0
54.80
43.89
65.71
19.9
7.7
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 28 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0222J000
R/T No.
1013
T (
C)
B
25/100
= 3900 K, R
25
= 2200
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
170030
136970
203080
19.4
2.8
6.9
50.0
120860
98819
142910
18.2
2.7
6.7
45.0
86914
72061
101770
17.1
2.6
6.5
40.0
63188
53084
73292
16.0
2.5
6.3
35.0
46417
39484
53350
14.9
2.5
6.1
30.0
34434
29638
39229
13.9
2.4
5.9
25.0
25772
22433
29112
13.0
2.3
5.7
20.0
19479
17136
21821
12.0
2.2
5.5
15.0
14835
13184
16486
11.1
2.1
5.4
10.0
11399
10229
12570
10.3
2.0
5.2
5.0
8822
7989
9655
9.4
1.9
5.0
0.0
6882
6288
7477
8.6
1.8
4.9
5.0
5405
4980
5831
7.9
1.7
4.8
10.0
4276
3972
4581
7.1
1.5
4.6
15.0
3404
3186
3623
6.4
1.4
4.5
20.0
2729
2573
2885
5.7
1.3
4.4
25.0
2200
2090
2310
5.0
1.2
4.3
30.0
1784
1683
1886
5.7
1.4
4.1
35.0
1455
1363
1547
6.3
1.6
4.0
40.0
1194
1111
1276
6.9
1.8
3.9
45.0
984.0
910.0
1058
7.5
2.0
3.8
50.0
815.5
749.5
881.4
8.1
2.2
3.7
55.0
679.0
620.4
737.7
8.6
2.4
3.6
60.0
568.2
516.0
620.3
9.2
2.6
3.5
65.0
477.6
431.3
523.8
9.7
2.8
3.4
70.0
403.1
362.0
444.2
10.2
3.0
3.3
75.0
341.8
305.3
378.3
10.7
3.3
3.3
80.0
290.9
258.4
323.4
11.2
3.5
3.2
85.0
248.6
219.7
277.5
11.6
3.7
3.1
90.0
213.3
187.5
239.0
12.1
4.0
3.0
95.0
183.7
160.7
206.7
12.5
4.2
3.0
100.0
158.7
138.2
179.2
12.9
4.5
2.9
105.0
137.6
119.3
156.0
13.4
4.7
2.8
110.0
119.7
103.3
136.2
13.8
5.0
2.8
115.0
104.5
89.73
119.3
14.1
5.3
2.7
120.0
91.51
78.21
104.8
14.5
5.5
2.6
125.0
80.37
68.39
92.35
14.9
5.8
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 29 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0222K000
R/T No.
1013
T (
C)
B
25/100
= 3900 K, R
25
= 2200
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
170030
128470
211580
24.4
3.5
6.9
50.0
120860
92776
148950
23.2
3.5
6.7
45.0
86914
67715
106110
22.1
3.4
6.5
40.0
63188
49925
76452
21.0
3.3
6.3
35.0
46417
37163
55671
19.9
3.3
6.1
30.0
34434
27917
40951
18.9
3.2
5.9
25.0
25772
21144
30400
18.0
3.1
5.7
20.0
19479
16163
22795
17.0
3.1
5.5
15.0
14835
12442
17228
16.1
3.0
5.4
10.0
11399
9659
13140
15.3
2.9
5.2
5.0
8822
7548
10096
14.4
2.9
5.0
0.0
6882
5943
7821
13.6
2.8
4.9
5.0
5405
4709
6101
12.9
2.7
4.8
10.0
4276
3758
4795
12.1
2.6
4.6
15.0
3404
3016
3793
11.4
2.5
4.5
20.0
2729
2436
3021
10.7
2.5
4.4
25.0
2200
1980
2420
10.0
2.4
4.3
30.0
1784
1593
1975
10.7
2.6
4.1
35.0
1455
1290
1620
11.3
2.8
4.0
40.0
1194
1051
1336
11.9
3.0
3.9
45.0
984.0
860.8
1107
12.5
3.3
3.8
50.0
815.5
708.8
922.2
13.1
3.5
3.7
55.0
679.0
586.4
771.6
13.6
3.8
3.6
60.0
568.2
487.6
648.7
14.2
4.0
3.5
65.0
477.6
407.4
547.7
14.7
4.3
3.4
70.0
403.1
341.9
464.4
15.2
4.5
3.3
75.0
341.8
288.2
395.4
15.7
4.8
3.3
80.0
290.9
243.9
337.9
16.2
5.1
3.2
85.0
248.6
207.3
290.0
16.6
5.4
3.1
90.0
213.3
176.9
249.7
17.1
5.6
3.0
95.0
183.7
151.5
215.8
17.5
5.9
3.0
100.0
158.7
130.2
187.2
17.9
6.2
2.9
105.0
137.6
112.4
162.9
18.4
6.5
2.8
110.0
119.7
97.28
142.2
18.8
6.8
2.8
115.0
104.5
84.50
124.5
19.1
7.1
2.7
120.0
91.51
73.63
109.4
19.5
7.4
2.6
125.0
80.37
64.37
96.37
19.9
7.7
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 30 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0332J000
R/T No.
4001
T (
C)
B
25/100
= 3950 K, R
25
= 3300
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
290570
233550
347600
19.6
2.7
7.3
50.0
203450
166000
240900
18.4
2.6
7.0
45.0
144300
119420
169180
17.2
2.6
6.8
40.0
103600
86892
120320
16.1
2.5
6.5
35.0
75246
63912
86581
15.1
2.4
6.3
30.0
55248
47491
63005
14.0
2.3
6.1
25.0
40812
35482
46141
13.1
2.2
5.9
20.0
30477
26784
34169
12.1
2.1
5.7
15.0
23126
20534
25718
11.2
2.0
5.5
10.0
17706
15876
19536
10.3
1.9
5.3
5.0
13616
12323
14909
9.5
1.8
5.2
0.0
10560
9643
11477
8.7
1.7
5.0
5.0
8245
7593
8897
7.9
1.6
4.9
10.0
6488
6024
6953
7.2
1.5
4.7
15.0
5147
4816
5478
6.4
1.4
4.6
20.0
4111
3875
4346
5.7
1.3
4.4
25.0
3300
3135
3465
5.0
1.2
4.3
30.0
2652
2500
2803
5.7
1.4
4.2
35.0
2156
2020
2293
6.3
1.6
4.1
40.0
1764
1641
1887
7.0
1.8
4.0
45.0
1451
1341
1560
7.5
2.0
3.9
50.0
1200
1102
1297
8.1
2.2
3.8
55.0
996.0
909.5
1083
8.7
2.4
3.7
60.0
831.2
754.6
907.9
9.2
2.6
3.6
65.0
697.5
629.5
765.5
9.8
2.8
3.5
70.0
588.0
527.7
648.4
10.3
3.0
3.4
75.0
497.9
444.4
551.5
10.8
3.3
3.3
80.0
423.5
375.9
471.1
11.2
3.5
3.2
85.0
361.3
319.0
403.6
11.7
3.7
3.1
90.0
309.4
271.7
347.0
12.2
4.0
3.1
95.0
266.5
232.9
300.1
12.6
4.2
3.0
100.0
230.5
200.4
260.5
13.0
4.5
2.9
105.0
199.5
172.7
226.3
13.5
4.7
2.9
110.0
173.2
149.2
197.3
13.9
5.0
2.8
115.0
150.9
129.4
172.5
14.3
5.2
2.7
120.0
131.9
112.6
151.2
14.7
5.5
2.7
125.0
115.4
98.09
132.8
15.0
5.8
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 31 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0332K000
R/T No.
4001
T (
C)
B
25/100
= 3950 K, R
25
= 3300
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
290570
219020
362130
24.6
3.4
7.3
50.0
203450
155820
251070
23.4
3.3
7.0
45.0
144300
112200
176400
22.2
3.3
6.8
40.0
103600
81712
125500
21.1
3.2
6.5
35.0
75246
60149
90343
20.1
3.2
6.3
30.0
55248
44729
65767
19.0
3.1
6.1
25.0
40812
33442
48181
18.1
3.1
5.9
20.0
30477
25261
35693
17.1
3.0
5.7
15.0
23126
19378
26874
16.2
2.9
5.5
10.0
17706
14990
20421
15.3
2.9
5.3
5.0
13616
11642
15590
14.5
2.8
5.2
0.0
10560
9115
12005
13.7
2.7
5.0
5.0
8245
7181
9310
12.9
2.7
4.9
10.0
6488
5700
7277
12.2
2.6
4.7
15.0
5147
4559
5735
11.4
2.5
4.6
20.0
4111
3670
4552
10.7
2.4
4.4
25.0
3300
2970
3630
10.0
2.3
4.3
30.0
2652
2368
2936
10.7
2.5
4.2
35.0
2156
1912
2401
11.3
2.8
4.1
40.0
1764
1553
1975
12.0
3.0
4.0
45.0
1451
1269
1633
12.5
3.2
3.9
50.0
1200
1042
1357
13.1
3.5
3.8
55.0
996.0
859.7
1132
13.7
3.7
3.7
60.0
831.2
713.0
949.5
14.2
4.0
3.6
65.0
697.5
594.6
800.4
14.8
4.2
3.5
70.0
588.0
498.3
677.8
15.3
4.5
3.4
75.0
497.9
419.5
576.4
15.8
4.8
3.3
80.0
423.5
354.7
492.3
16.2
5.0
3.2
85.0
361.3
300.9
421.6
16.7
5.3
3.1
90.0
309.4
256.3
362.5
17.2
5.6
3.1
95.0
266.5
219.6
313.4
17.6
5.9
3.0
100.0
230.5
188.9
272.1
18.0
6.2
2.9
105.0
199.5
162.7
236.3
18.5
6.5
2.9
110.0
173.2
140.6
205.9
18.9
6.8
2.8
115.0
150.9
121.9
180.0
19.3
7.1
2.7
120.0
131.9
106.0
157.8
19.7
7.4
2.7
125.0
115.4
92.32
138.6
20.0
7.7
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 32 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0472J000
R/T No.
4001
T (
C)
B
25/100
= 3950 K, R
25
= 4700
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
413850
332630
495060
19.6
2.7
7.3
50.0
289760
236420
343100
18.4
2.6
7.0
45.0
205520
170080
240960
17.2
2.6
6.8
40.0
147560
123760
171360
16.1
2.5
6.5
35.0
107170
91026
123310
15.1
2.4
6.3
30.0
78687
67639
89734
14.0
2.3
6.1
25.0
58126
50535
65716
13.1
2.2
5.9
20.0
43406
38147
48665
12.1
2.1
5.7
15.0
32937
29245
36629
11.2
2.0
5.5
10.0
25217
22611
27824
10.3
1.9
5.3
5.0
19392
17551
21234
9.5
1.8
5.2
0.0
15040
13733
16347
8.7
1.7
5.0
5.0
11743
10815
12672
7.9
1.6
4.9
10.0
9241
8580
9902
7.2
1.5
4.7
15.0
7330
6859
7802
6.4
1.4
4.6
20.0
5855
5520
6190
5.7
1.3
4.4
25.0
4700
4465
4935
5.0
1.2
4.3
30.0
3777
3561
3992
5.7
1.4
4.2
35.0
3071
2877
3266
6.3
1.6
4.1
40.0
2512
2338
2687
7.0
1.8
4.0
45.0
2066
1910
2222
7.5
2.0
3.9
50.0
1709
1570
1848
8.1
2.2
3.8
55.0
1419
1295
1542
8.7
2.4
3.7
60.0
1184
1075
1293
9.2
2.6
3.6
65.0
993.4
896.5
1090
9.8
2.8
3.5
70.0
837.5
751.5
923.4
10.3
3.0
3.4
75.0
709.2
632.9
785.5
10.8
3.3
3.3
80.0
603.2
535.4
671.0
11.2
3.5
3.2
85.0
514.5
454.3
574.8
11.7
3.7
3.1
90.0
440.6
387.0
494.2
12.2
4.0
3.1
95.0
379.6
331.7
427.4
12.6
4.2
3.0
100.0
328.3
285.5
371.1
13.0
4.5
2.9
105.0
284.1
245.9
322.4
13.5
4.7
2.9
110.0
246.7
212.5
281.0
13.9
5.0
2.8
115.0
215.0
184.3
245.6
14.3
5.2
2.7
120.0
187.9
160.3
215.4
14.7
5.5
2.7
125.0
164.4
139.7
189.1
15.0
5.8
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 33 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0472K000
R/T No.
4001
T (
C)
B
25/100
= 3950 K, R
25
= 4700
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
413850
311930
515760
24.6
3.4
7.3
50.0
289760
221930
357580
23.4
3.3
7.0
45.0
205520
159800
251230
22.2
3.3
6.8
40.0
147560
116380
178740
21.1
3.2
6.5
35.0
107170
85667
128670
20.1
3.2
6.3
30.0
78687
63704
93669
19.0
3.1
6.1
25.0
58126
47629
68622
18.1
3.1
5.9
20.0
43406
35977
50835
17.1
3.0
5.7
15.0
32937
27598
38276
16.2
2.9
5.5
10.0
25217
21350
29085
15.3
2.9
5.3
5.0
19392
16581
22203
14.5
2.8
5.2
0.0
15040
12981
17099
13.7
2.7
5.0
5.0
11743
10228
13259
12.9
2.7
4.9
10.0
9241
8118
10364
12.2
2.6
4.7
15.0
7330
6493
8168
11.4
2.5
4.6
20.0
5855
5227
6483
10.7
2.4
4.4
25.0
4700
4230
5170
10.0
2.3
4.3
30.0
3777
3372
4181
10.7
2.5
4.2
35.0
3071
2723
3420
11.3
2.8
4.1
40.0
2512
2212
2813
12.0
3.0
4.0
45.0
2066
1807
2326
12.5
3.2
3.9
50.0
1709
1485
1933
13.1
3.5
3.8
55.0
1419
1224
1613
13.7
3.7
3.7
60.0
1184
1015
1352
14.2
4.0
3.6
65.0
993.4
846.9
1140
14.8
4.2
3.5
70.0
837.5
709.7
965.3
15.3
4.5
3.4
75.0
709.2
597.4
821.0
15.8
4.8
3.3
80.0
603.2
505.2
701.1
16.2
5.0
3.2
85.0
514.5
428.6
600.5
16.7
5.3
3.1
90.0
440.6
365.0
516.2
17.2
5.6
3.1
95.0
379.6
312.8
446.4
17.6
5.9
3.0
100.0
328.3
269.0
387.5
18.0
6.2
2.9
105.0
284.1
231.7
336.6
18.5
6.5
2.9
110.0
246.7
200.2
293.3
18.9
6.8
2.8
115.0
215.0
173.6
256.4
19.3
7.1
2.7
120.0
187.9
150.9
224.8
19.7
7.4
2.7
125.0
164.4
131.5
197.4
20.0
7.7
2.6
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 34 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0682J000
R/T No.
2903
T (
C)
B
25/100
= 4200 K, R
25
= 6800
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
816190
648480
983900
20.5
2.7
7.6
50.0
560180
452330
668040
19.3
2.6
7.4
45.0
389280
319150
459420
18.0
2.5
7.2
40.0
273740
227660
319810
16.8
2.4
7.0
35.0
194670
164110
225220
15.7
2.3
6.7
30.0
139930
119490
160370
14.6
2.2
6.5
25.0
101150
87433
114880
13.6
2.1
6.3
20.0
73987
64692
83281
12.6
2.1
6.1
15.0
54950
48577
61323
11.6
2.0
5.9
10.0
41216
36818
45614
10.7
1.9
5.7
5.0
31042
28006
34077
9.8
1.8
5.6
0.0
23602
21497
25706
8.9
1.7
5.4
5.0
18105
16640
19569
8.1
1.6
5.2
10.0
14007
12986
15028
7.3
1.4
5.1
15.0
10927
10215
11639
6.5
1.3
4.9
20.0
8589
8093
9085
5.8
1.2
4.8
25.0
6800
6460
7140
5.0
1.1
4.6
30.0
5412
5101
5723
5.7
1.3
4.5
35.0
4338
4060
4617
6.4
1.5
4.4
40.0
3500
3252
3747
7.1
1.7
4.2
45.0
2848
2629
3068
7.7
1.9
4.1
50.0
2331
2137
2524
8.3
2.1
4.0
55.0
1909
1739
2080
8.9
2.3
3.9
60.0
1574
1424
1723
9.5
2.5
3.8
65.0
1306
1175
1438
10.0
2.7
3.7
70.0
1090
974.4
1205
10.6
2.9
3.6
75.0
912.6
811.1
1014
11.1
3.2
3.5
80.0
767.6
678.3
856.8
11.6
3.4
3.4
85.0
648.2
569.6
726.8
12.1
3.6
3.3
90.0
549.6
480.3
619.0
12.6
3.9
3.2
95.0
468.6
407.3
530.0
13.1
4.1
3.2
100.0
401.1
346.8
455.5
13.5
4.4
3.1
105.0
344.8
296.5
393.0
14.0
4.6
3.0
110.0
297.4
254.5
340.3
14.4
4.9
2.9
115.0
256.9
218.7
295.0
14.8
5.2
2.9
120.0
222.6
188.6
256.6
15.3
5.4
2.8
125.0
193.9
163.5
224.3
15.7
5.7
2.7
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 35 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0682K000
R/T No.
2903
T (
C)
B
25/100
= 4200 K, R
25
= 6800
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
816190
607670
1024700
25.5
3.3
7.6
50.0
560180
424320
696050
24.3
3.3
7.4
45.0
389280
299690
478880
23.0
3.2
7.2
40.0
273740
213980
333500
21.8
3.1
7.0
35.0
194670
154370
234960
20.7
3.1
6.7
30.0
139930
112490
167370
19.6
3.0
6.5
25.0
101150
82375
119930
18.6
2.9
6.3
20.0
73987
60993
86980
17.6
2.9
6.1
15.0
54950
45829
64070
16.6
2.8
5.9
10.0
41216
34757
47675
15.7
2.7
5.7
5.0
31042
26454
35629
14.8
2.7
5.6
0.0
23602
20317
26887
13.9
2.6
5.4
5.0
18105
15735
20475
13.1
2.5
5.2
10.0
14007
12286
15728
12.3
2.4
5.1
15.0
10927
9668
12185
11.5
2.3
4.9
20.0
8589
7664
9514
10.8
2.3
4.8
25.0
6800
6120
7480
10.0
2.2
4.6
30.0
5412
4831
5994
10.7
2.4
4.5
35.0
4338
3843
4834
11.4
2.6
4.4
40.0
3500
3077
3922
12.1
2.9
4.2
45.0
2848
2486
3210
12.7
3.1
4.1
50.0
2331
2020
2641
13.3
3.3
4.0
55.0
1909
1644
2175
13.9
3.6
3.9
60.0
1574
1346
1802
14.5
3.8
3.8
65.0
1306
1110
1503
15.0
4.1
3.7
70.0
1090
919.9
1260
15.6
4.3
3.6
75.0
912.6
765.5
1060
16.1
4.6
3.5
80.0
767.6
639.9
895.2
16.6
4.9
3.4
85.0
648.2
537.2
759.3
17.1
5.2
3.3
90.0
549.6
452.8
646.4
17.6
5.4
3.2
95.0
468.6
383.9
553.4
18.1
5.7
3.2
100.0
401.1
326.7
475.5
18.5
6.0
3.1
105.0
344.8
279.3
410.2
19.0
6.3
3.0
110.0
297.4
239.6
355.2
19.4
6.6
2.9
115.0
256.9
205.9
307.9
19.8
6.9
2.9
120.0
222.6
177.5
267.7
20.3
7.2
2.8
125.0
193.9
153.8
234.0
20.7
7.5
2.7
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 36 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0103J000
R/T No.
2904
T (
C)
B
25/100
= 4300 K, R
25
= 10000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1214600
960540
1468600
20.9
2.9
7.3
50.0
844390
678960
1009800
19.6
2.7
7.1
45.0
592430
483870
701000
18.3
2.6
7.0
40.0
419380
347620
491150
17.1
2.5
6.9
35.0
299480
251710
347240
16.0
2.4
6.7
30.0
215670
183670
247670
14.8
2.3
6.5
25.0
156410
134870
177940
13.8
2.2
6.3
20.0
114660
100050
129270
12.7
2.1
6.2
15.0
84510
74576
94443
11.8
2.0
6.0
10.0
62927
56128
69726
10.8
1.9
5.8
5.0
47077
42421
51733
9.9
1.8
5.6
0.0
35563
32359
38767
9.0
1.6
5.5
5.0
27119
24905
29332
8.2
1.5
5.3
10.0
20860
19328
22391
7.3
1.4
5.2
15.0
16204
15143
17266
6.6
1.3
5.0
20.0
12683
11949
13418
5.8
1.2
4.9
25.0
10000
9500
10500
5.0
1.1
4.7
30.0
7942
7484
8400
5.8
1.3
4.6
35.0
6327
5918
6735
6.5
1.4
4.5
40.0
5074
4713
5435
7.1
1.6
4.3
45.0
4103
3784
4421
7.8
1.8
4.2
50.0
3336
3056
3616
8.4
2.0
4.1
55.0
2724
2479
2970
9.0
2.3
4.0
60.0
2237
2022
2452
9.6
2.5
3.9
65.0
1846
1658
2034
10.2
2.7
3.8
70.0
1530
1366
1695
10.7
2.9
3.7
75.0
1275
1132
1419
11.3
3.1
3.6
80.0
1068
941.9
1194
11.8
3.4
3.5
85.0
899.3
788.7
1010
12.3
3.6
3.4
90.0
760.7
663.4
858.0
12.8
3.8
3.3
95.0
645.2
559.6
730.9
13.3
4.1
3.2
100.0
549.4
473.9
624.9
13.7
4.3
3.2
105.0
470.0
403.3
536.8
14.2
4.6
3.1
110.0
403.6
344.5
462.7
14.6
4.8
3.0
115.0
347.4
295.0
399.8
15.1
5.1
3.0
120.0
300.1
253.5
346.6
15.5
5.4
2.9
125.0
260.1
218.7
301.5
15.9
5.6
2.8
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 37 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0103K000
R/T No.
2904
T (
C)
B
25/100
= 4300 K, R
25
= 10000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1214600
899810
1529400
25.9
3.6
7.3
50.0
844390
636740
1052000
24.6
3.4
7.1
45.0
592430
454250
730620
23.3
3.3
7.0
40.0
419380
326650
512120
22.1
3.2
6.9
35.0
299480
236730
362220
21.0
3.1
6.7
30.0
215670
172890
258460
19.8
3.0
6.5
25.0
156410
127050
185760
18.8
3.0
6.3
20.0
114660
94315
135000
17.7
2.9
6.2
15.0
84510
70351
98669
16.8
2.8
6.0
10.0
62927
52981
72872
15.8
2.7
5.8
5.0
47077
40067
54087
14.9
2.6
5.6
0.0
35563
30581
40545
14.0
2.6
5.5
5.0
27119
23550
30688
13.2
2.5
5.3
10.0
20860
18285
23434
12.3
2.4
5.2
15.0
16204
14332
18076
11.6
2.3
5.0
20.0
12683
11315
14052
10.8
2.2
4.9
25.0
10000
9000
11000
10.0
2.1
4.7
30.0
7942
7087
8797
10.8
2.3
4.6
35.0
6327
5602
7051
11.5
2.6
4.5
40.0
5074
4459
5689
12.1
2.8
4.3
45.0
4103
3579
4627
12.8
3.0
4.2
50.0
3336
2889
3783
13.4
3.3
4.1
55.0
2724
2343
3106
14.0
3.5
4.0
60.0
2237
1910
2563
14.6
3.8
3.9
65.0
1846
1566
2126
15.2
4.0
3.8
70.0
1530
1290
1771
15.7
4.3
3.7
75.0
1275
1068
1483
16.3
4.5
3.6
80.0
1068
888.5
1247
16.8
4.8
3.5
85.0
899.3
743.7
1055
17.3
5.1
3.4
90.0
760.7
625.3
896.0
17.8
5.3
3.3
95.0
645.2
527.3
763.2
18.3
5.6
3.2
100.0
549.4
446.4
652.4
18.7
5.9
3.2
105.0
470.0
379.8
560.3
19.2
6.2
3.1
110.0
403.6
324.3
482.9
19.6
6.5
3.0
115.0
347.4
277.7
417.2
20.1
6.8
3.0
120.0
300.1
238.5
361.6
20.5
7.1
2.9
125.0
260.1
205.7
314.5
20.9
7.4
2.8
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 38 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0153J000
R/T No.
1014
T (
C)
B
25/100
= 4250 K, R
25
= 15000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1259000
998000
1520100
20.7
3.1
6.6
50.0
903420
727950
1078900
19.4
3.0
6.5
45.0
653890
535080
772710
18.2
2.9
6.4
40.0
477220
396230
558220
17.0
2.7
6.2
35.0
351070
295510
406620
15.8
2.6
6.1
30.0
260240
221930
298560
14.7
2.5
5.9
25.0
194190
167650
220730
13.7
2.4
5.8
20.0
146160
127670
164650
12.7
2.2
5.7
15.0
110610
97692
123520
11.7
2.1
5.5
10.0
84370
75311
93429
10.7
2.0
5.4
5.0
64595
58242
70947
9.8
1.9
5.2
0.0
49831
45364
54298
9.0
1.8
5.1
5.0
38668
35526
41810
8.1
1.6
5.0
10.0
30216
28005
32426
7.3
1.5
4.9
15.0
23772
22219
25326
6.5
1.4
4.7
20.0
18820
17733
19908
5.8
1.2
4.6
25.0
15000
14250
15750
5.0
1.1
4.5
30.0
11987
11297
12677
5.8
1.3
4.4
35.0
9643
9022
10264
6.4
1.5
4.3
40.0
7799
7245
8352
7.1
1.7
4.2
45.0
6345
5854
6836
7.7
1.9
4.1
50.0
5186
4752
5619
8.4
2.1
4.0
55.0
4245
3864
4625
9.0
2.3
3.9
60.0
3492
3158
3825
9.5
2.5
3.8
65.0
2889
2597
3181
10.1
2.7
3.7
70.0
2401
2145
2657
10.7
2.9
3.7
75.0
2002
1778
2226
11.2
3.1
3.6
80.0
1676
1480
1873
11.7
3.3
3.5
85.0
1409
1237
1581
12.2
3.5
3.4
90.0
1188
1037
1339
12.7
3.8
3.4
95.0
1006
873.2
1138
13.2
4.0
3.3
100.0
854.0
737.4
970.5
13.6
4.2
3.2
105.0
728.9
626.1
831.6
14.1
4.4
3.2
110.0
624.1
533.4
714.8
14.5
4.7
3.1
115.0
534.8
454.8
614.8
15.0
4.9
3.1
120.0
459.5
388.9
530.2
15.4
5.1
3.0
125.0
396.8
334.2
459.5
15.8
5.4
2.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 39 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0153K000
R/T No.
1014
T (
C)
B
25/100
= 4250 K, R
25
= 15000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1259000
935050
1583000
25.7
3.9
6.6
50.0
903420
682780
1124100
24.4
3.8
6.5
45.0
653890
502380
805400
23.2
3.6
6.4
40.0
477220
372370
582080
22.0
3.5
6.2
35.0
351070
277960
424170
20.8
3.4
6.1
30.0
260240
208910
311570
19.7
3.3
5.9
25.0
194190
157950
230440
18.7
3.2
5.8
20.0
146160
120360
171960
17.7
3.1
5.7
15.0
110610
92161
129050
16.7
3.0
5.5
10.0
84370
71092
97648
15.7
2.9
5.4
5.0
64595
55013
74177
14.8
2.8
5.2
0.0
49831
42873
56790
14.0
2.7
5.1
5.0
38668
33593
43743
13.1
2.6
5.0
10.0
30216
26495
33937
12.3
2.5
4.9
15.0
23772
21031
26514
11.5
2.4
4.7
20.0
18820
16792
20849
10.8
2.3
4.6
25.0
15000
13500
16500
10.0
2.2
4.5
30.0
11987
10698
13276
10.8
2.4
4.4
35.0
9643
8540
10746
11.4
2.7
4.3
40.0
7799
6855
8742
12.1
2.9
4.2
45.0
6345
5537
7153
12.7
3.1
4.1
50.0
5186
4493
5879
13.4
3.3
4.0
55.0
4245
3652
4837
14.0
3.6
3.9
60.0
3492
2984
3999
14.5
3.8
3.8
65.0
2889
2453
3326
15.1
4.0
3.7
70.0
2401
2025
2777
15.7
4.3
3.7
75.0
2002
1678
2327
16.2
4.5
3.6
80.0
1676
1396
1956
16.7
4.8
3.5
85.0
1409
1166
1652
17.2
5.0
3.4
90.0
1188
978.1
1399
17.7
5.3
3.4
95.0
1006
822.9
1189
18.2
5.5
3.3
100.0
854.0
694.7
1013
18.6
5.8
3.2
105.0
728.9
589.7
868.1
19.1
6.0
3.2
110.0
624.1
502.1
746.0
19.5
6.3
3.1
115.0
534.8
428.0
641.6
20.0
6.5
3.1
120.0
459.5
365.9
553.2
20.4
6.8
3.0
125.0
396.8
314.3
479.3
20.8
7.1
2.9
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 40 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0223J000
R/T No.
1012
T (
C)
B
25/100
= 4300 K, R
25
= 22000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1919200
1517800
2320700
20.9
3.1
6.8
50.0
1369800
1101400
1638200
19.6
2.9
6.7
45.0
986790
805960
1167600
18.3
2.8
6.5
40.0
717180
594450
839900
17.1
2.7
6.3
35.0
525650
441800
609490
16.0
2.6
6.2
30.0
388390
330760
446010
14.8
2.5
6.0
25.0
288150
248480
327830
13.8
2.4
5.8
20.0
215730
188240
243220
12.7
2.2
5.7
15.0
163380
144180
182590
11.8
2.1
5.5
10.0
124690
111220
138160
10.8
2.0
5.4
5.0
95069
85666
104470
9.9
1.9
5.3
0.0
73058
66476
79641
9.0
1.8
5.1
5.0
56853
52213
61493
8.2
1.6
5.0
10.0
44524
41255
47793
7.3
1.5
4.9
15.0
34887
32601
37172
6.6
1.4
4.8
20.0
27514
25922
29107
5.8
1.2
4.7
25.0
22000
20900
23100
5.0
1.1
4.6
30.0
17521
16511
18531
5.8
1.3
4.4
35.0
14092
13182
15001
6.5
1.5
4.3
40.0
11390
10579
12201
7.1
1.7
4.2
45.0
9231
8514
9948
7.8
1.9
4.1
50.0
7518
6886
8149
8.4
2.1
4.1
55.0
6133
5581
6685
9.0
2.3
4.0
60.0
5029
4547
5512
9.6
2.5
3.9
65.0
4152
3730
4574
10.2
2.7
3.8
70.0
3442
3073
3811
10.7
2.9
3.7
75.0
2863
2540
3185
11.3
3.1
3.6
80.0
2390
2108
2671
11.8
3.3
3.6
85.0
2005
1758
2251
12.3
3.5
3.5
90.0
1687
1472
1903
12.8
3.8
3.4
95.0
1427
1238
1617
13.3
4.0
3.3
100.0
1211
1045
1377
13.7
4.2
3.3
105.0
1030
883.3
1176
14.2
4.4
3.2
110.0
877.9
749.3
1006
14.6
4.7
3.1
115.0
753.6
640.0
867.3
15.1
4.9
3.1
120.0
649.0
548.3
749.6
15.5
5.1
3.0
125.0
559.9
470.8
649.0
15.9
5.4
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 41 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0223K000
R/T No.
1012
T (
C)
B
25/100
= 4300 K, R
25
= 22000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
1919200
1421800
2416600
25.9
3.8
6.8
50.0
1369800
1033000
1706700
24.6
3.7
6.7
45.0
986790
756620
1217000
23.3
3.6
6.5
40.0
717180
558590
875760
22.1
3.5
6.3
35.0
525650
415520
635770
21.0
3.4
6.2
30.0
388390
311340
465430
19.8
3.3
6.0
25.0
288150
234070
342240
18.8
3.2
5.8
20.0
215730
177460
254000
17.7
3.1
5.7
15.0
163380
136010
190760
16.8
3.0
5.5
10.0
124690
104980
144400
15.8
2.9
5.4
5.0
95069
80913
109230
14.9
2.8
5.3
0.0
73058
62823
83294
14.0
2.7
5.1
5.0
56853
49371
64335
13.2
2.6
5.0
10.0
44524
39029
50019
12.3
2.5
4.9
15.0
34887
30857
38916
11.6
2.4
4.8
20.0
27514
24546
30483
10.8
2.3
4.7
25.0
22000
19800
24200
10.0
2.2
4.6
30.0
17521
15635
19407
10.8
2.4
4.4
35.0
14092
12478
15706
11.5
2.6
4.3
40.0
11390
10009
12771
12.1
2.9
4.2
45.0
9231
8052
10410
12.8
3.1
4.1
50.0
7518
6511
8525
13.4
3.3
4.1
55.0
6133
5274
6992
14.0
3.5
4.0
60.0
5029
4295
5763
14.6
3.8
3.9
65.0
4152
3522
4782
15.2
4.0
3.8
70.0
3442
2901
3983
15.7
4.2
3.7
75.0
2863
2397
3328
16.3
4.5
3.6
80.0
2390
1989
2791
16.8
4.7
3.6
85.0
2005
1658
2351
17.3
5.0
3.5
90.0
1687
1387
1988
17.8
5.2
3.4
95.0
1427
1166
1688
18.3
5.5
3.3
100.0
1211
984.0
1438
18.7
5.7
3.3
105.0
1030
831.8
1227
19.2
6.0
3.2
110.0
877.9
705.4
1050
19.6
6.3
3.1
115.0
753.6
602.3
905.0
20.1
6.5
3.1
120.0
649.0
515.9
782.0
20.5
6.8
3.0
125.0
559.9
442.8
677.0
20.9
7.1
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 42 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0333J000
R/T No.
1012
T (
C)
B
25/100
= 4300 K, R
25
= 33000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
2878800
2276700
3481000
20.9
3.1
6.8
50.0
2054700
1652200
2457300
19.6
2.9
6.7
45.0
1480200
1208900
1751400
18.3
2.8
6.5
40.0
1075800
891680
1259900
17.1
2.7
6.3
35.0
788470
662700
914230
16.0
2.6
6.2
30.0
582580
496140
669020
14.8
2.5
6.0
25.0
432230
372720
491740
13.8
2.4
5.8
20.0
323590
282360
364820
12.7
2.2
5.7
15.0
245080
216270
273880
11.8
2.1
5.5
10.0
187040
166830
207240
10.8
2.0
5.4
5.0
142600
128500
156710
9.9
1.9
5.3
0.0
109590
99714
119460
9.0
1.8
5.1
5.0
85279
78320
92239
8.2
1.6
5.0
10.0
66786
61883
71690
7.3
1.5
4.9
15.0
52330
48901
55758
6.6
1.4
4.8
20.0
41272
38883
43660
5.8
1.2
4.7
25.0
33000
31350
34650
5.0
1.1
4.6
30.0
26281
24767
27796
5.8
1.3
4.4
35.0
21138
19773
22502
6.5
1.5
4.3
40.0
17085
15868
18302
7.1
1.7
4.2
45.0
13846
12770
14922
7.8
1.9
4.1
50.0
11277
10330
12224
8.4
2.1
4.1
55.0
9199
8371
10028
9.0
2.3
4.0
60.0
7544
6820
8268
9.6
2.5
3.9
65.0
6228
5595
6861
10.2
2.7
3.8
70.0
5163
4609
5716
10.7
2.9
3.7
75.0
4294
3810
4778
11.3
3.1
3.6
80.0
3585
3162
4007
11.8
3.3
3.6
85.0
3007
2637
3377
12.3
3.5
3.5
90.0
2531
2207
2855
12.8
3.8
3.4
95.0
2141
1856
2425
13.3
4.0
3.3
100.0
1817
1567
2066
13.7
4.2
3.3
105.0
1544
1325
1764
14.2
4.4
3.2
110.0
1317
1124
1510
14.6
4.7
3.1
115.0
1130
959.9
1301
15.1
4.9
3.1
120.0
973.4
822.5
1124
15.5
5.1
3.0
125.0
839.8
706.1
973.5
15.9
5.4
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 43 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0333K000
R/T No.
1012
T (
C)
B
25/100
= 4300 K, R
25
= 33000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
2878800
2132700
3624900
25.9
3.8
6.8
50.0
2054700
1549400
2560000
24.6
3.7
6.7
45.0
1480200
1134900
1825400
23.3
3.6
6.5
40.0
1075800
837890
1313600
22.1
3.5
6.3
35.0
788470
623280
953660
21.0
3.4
6.2
30.0
582580
467010
698140
19.8
3.3
6.0
25.0
432230
351110
513350
18.8
3.2
5.8
20.0
323590
266180
381000
17.7
3.1
5.7
15.0
245080
204020
286140
16.8
3.0
5.5
10.0
187040
157470
216600
15.8
2.9
5.4
5.0
142600
121370
163840
14.9
2.8
5.3
0.0
109590
94234
124940
14.0
2.7
5.1
5.0
85279
74056
96503
13.2
2.6
5.0
10.0
66786
58543
75029
12.3
2.5
4.9
15.0
52330
46285
58375
11.6
2.4
4.8
20.0
41272
36819
45724
10.8
2.3
4.7
25.0
33000
29700
36300
10.0
2.2
4.6
30.0
26281
23452
29110
10.8
2.4
4.4
35.0
21138
18717
23559
11.5
2.6
4.3
40.0
17085
15014
19156
12.1
2.9
4.2
45.0
13846
12078
15614
12.8
3.1
4.1
50.0
11277
9766
12787
13.4
3.3
4.1
55.0
9199
7911
10488
14.0
3.5
4.0
60.0
7544
6443
8645
14.6
3.8
3.9
65.0
6228
5283
7172
15.2
4.0
3.8
70.0
5163
4351
5974
15.7
4.2
3.7
75.0
4294
3596
4992
16.3
4.5
3.6
80.0
3585
2983
4186
16.8
4.7
3.6
85.0
3007
2487
3527
17.3
5.0
3.5
90.0
2531
2081
2982
17.8
5.2
3.4
95.0
2141
1749
2532
18.3
5.5
3.3
100.0
1817
1476
2157
18.7
5.7
3.3
105.0
1544
1248
1841
19.2
6.0
3.2
110.0
1317
1058
1576
19.6
6.3
3.1
115.0
1130
903.4
1357
20.1
6.5
3.1
120.0
973.4
773.8
1173
20.5
6.8
3.0
125.0
839.8
664.1
1015
20.9
7.1
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 44 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0473J000
R/T No.
4003
T (
C)
B
25/100
= 4450 K, R
25
= 47000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
4879100
3831600
5926700
21.5
3.1
6.8
50.0
3464200
2768000
4160500
20.1
3.0
6.7
45.0
2478000
2012400
2943500
18.8
2.8
6.6
40.0
1785400
1472400
2098500
17.5
2.7
6.5
35.0
1295600
1084000
1507200
16.3
2.6
6.4
30.0
946690
803000
1090400
15.2
2.4
6.2
25.0
695650
597760
793550
14.1
2.3
6.1
20.0
515860
448750
582970
13.0
2.2
6.0
15.0
384200
338140
430260
12.0
2.1
5.8
10.0
288610
256850
320380
11.0
1.9
5.7
5.0
217760
195850
239660
10.1
1.8
5.5
0.0
165640
150490
180800
9.1
1.7
5.4
5.0
126880
116380
137370
8.3
1.6
5.3
10.0
97906
90639
105170
7.4
1.4
5.1
15.0
76090
71065
81115
6.6
1.3
5.0
20.0
59531
56070
62992
5.8
1.2
4.9
25.0
47000
44650
49350
5.0
1.1
4.8
30.0
36825
34693
38957
5.8
1.2
4.6
35.0
29315
27409
31221
6.5
1.4
4.5
40.0
23470
21782
25159
7.2
1.6
4.4
45.0
18903
17416
20389
7.9
1.8
4.3
50.0
15302
13999
16604
8.5
2.0
4.2
55.0
12409
11274
13544
9.1
2.2
4.1
60.0
10118
9131
11105
9.8
2.4
4.0
65.0
8316
7455
9176
10.3
2.6
3.9
70.0
6869
6119
7620
10.9
2.8
3.8
75.0
5685
5033
6338
11.5
3.1
3.8
80.0
4725
4157
5293
12.0
3.3
3.7
85.0
3937
3443
4431
12.6
3.5
3.6
90.0
3292
2862
3722
13.1
3.7
3.5
95.0
2770
2394
3146
13.6
3.9
3.4
100.0
2340
2011
2668
14.0
4.2
3.4
105.0
1981
1693
2269
14.5
4.4
3.3
110.0
1683
1431
1935
15.0
4.6
3.2
115.0
1434
1212
1655
15.4
4.9
3.2
120.0
1225
1031
1420
15.9
5.1
3.1
125.0
1050
878.6
1221
16.3
5.4
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 45 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0473K000
R/T No.
4003
T (
C)
B
25/100
= 4450 K, R
25
= 47000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
4879100
3587600
6170700
26.5
3.9
6.8
50.0
3464200
2594800
4333700
25.1
3.7
6.7
45.0
2478000
1888500
3067400
23.8
3.6
6.6
40.0
1785400
1383100
2187700
22.5
3.5
6.5
35.0
1295600
1019200
1571900
21.3
3.3
6.4
30.0
946690
755660
1137700
20.2
3.2
6.2
25.0
695650
562980
828330
19.1
3.1
6.1
20.0
515860
422960
608770
18.0
3.0
6.0
15.0
384200
318930
449460
17.0
2.9
5.8
10.0
288610
242420
334810
16.0
2.8
5.7
5.0
217760
184960
250550
15.1
2.7
5.5
0.0
165640
142210
189080
14.1
2.6
5.4
5.0
126880
110040
143710
13.3
2.5
5.3
10.0
97906
85744
110070
12.4
2.4
5.1
15.0
76090
67260
84919
11.6
2.3
5.0
20.0
59531
53094
65969
10.8
2.2
4.9
25.0
47000
42300
51700
10.0
2.1
4.8
30.0
36825
32852
40798
10.8
2.3
4.6
35.0
29315
25943
32687
11.5
2.5
4.5
40.0
23470
20608
26333
12.2
2.8
4.4
45.0
18903
16471
21334
12.9
3.0
4.3
50.0
15302
13234
17370
13.5
3.2
4.2
55.0
12409
10654
14164
14.1
3.4
4.1
60.0
10118
8625
11611
14.8
3.7
4.0
65.0
8316
7040
9592
15.3
3.9
3.9
70.0
6869
5776
7963
15.9
4.1
3.8
75.0
5685
4748
6622
16.5
4.4
3.8
80.0
4725
3921
5529
17.0
4.6
3.7
85.0
3937
3246
4628
17.6
4.9
3.6
90.0
3292
2697
3886
18.1
5.1
3.5
95.0
2770
2256
3284
18.6
5.4
3.4
100.0
2340
1894
2785
19.0
5.7
3.4
105.0
1981
1594
2368
19.5
5.9
3.3
110.0
1683
1346
2019
20.0
6.2
3.2
115.0
1434
1141
1727
20.4
6.5
3.2
120.0
1225
969.5
1481
20.9
6.7
3.1
125.0
1050
826.1
1273
21.3
7.0
3.0
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 46 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0683J000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 68000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
8175000
6374600
9975500
22.0
3.2
6.8
50.0
5812600
4614900
7010400
20.6
3.0
6.8
45.0
4148200
3349700
4946800
19.3
2.8
6.8
40.0
2972400
2438800
3506100
18.0
2.7
6.7
35.0
2139200
1781700
2496700
16.7
2.5
6.6
30.0
1546700
1306700
1786800
15.5
2.4
6.4
25.0
1121300
960100
1282500
14.4
2.3
6.3
20.0
820800
711820
929780
13.3
2.1
6.2
15.0
601490
527980
675010
12.2
2.0
6.0
10.0
445030
395160
494910
11.2
1.9
5.9
5.0
332200
298220
366170
10.2
1.8
5.7
0.0
250110
226880
273330
9.3
1.7
5.6
5.0
190020
174100
205940
8.4
1.5
5.5
10.0
145460
134550
156370
7.5
1.4
5.3
15.0
112250
104780
119720
6.7
1.3
5.2
20.0
87197
82105
92289
5.8
1.2
5.1
25.0
68000
64600
71400
5.0
1.0
4.9
30.0
53307
50208
56406
5.8
1.2
4.8
35.0
42039
39285
44794
6.6
1.4
4.7
40.0
33356
30932
35780
7.3
1.6
4.6
45.0
26599
24481
28716
8.0
1.8
4.5
50.0
21332
19491
23173
8.6
2.0
4.3
55.0
17230
15631
18829
9.3
2.2
4.2
60.0
13984
12598
15370
9.9
2.4
4.1
65.0
11398
10199
12598
10.5
2.6
4.1
70.0
9334
8296
10372
11.1
2.8
4.0
75.0
7669
6772
8567
11.7
3.0
3.9
80.0
6328
5552
7103
12.3
3.2
3.8
85.0
5248
4576
5920
12.8
3.5
3.7
90.0
4370
3787
4953
13.3
3.7
3.6
95.0
3650
3145
4156
13.9
3.9
3.5
100.0
3060
2621
3499
14.4
4.1
3.5
105.0
2578
2196
2961
14.8
4.4
3.4
110.0
2180
1846
2514
15.3
4.6
3.3
115.0
1847
1555
2138
15.8
4.8
3.3
120.0
1569
1315
1824
16.2
5.1
3.2
125.0
1338
1115
1561
16.7
5.3
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 47 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0683K000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 68000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
8175000
5965800
10384000
27.0
4.0
6.8
50.0
5812600
4324200
7301000
25.6
3.8
6.8
45.0
4148200
3142200
5154200
24.3
3.6
6.8
40.0
2972400
2290100
3654700
23.0
3.4
6.7
35.0
2139200
1674800
2603700
21.7
3.3
6.6
30.0
1546700
1229300
1864100
20.5
3.2
6.4
25.0
1121300
904030
1338600
19.4
3.1
6.3
20.0
820800
670780
970820
18.3
3.0
6.2
15.0
601490
497900
705080
17.2
2.9
6.0
10.0
445030
372910
517160
16.2
2.8
5.9
5.0
332200
281610
382780
15.2
2.7
5.7
0.0
250110
214380
285840
14.3
2.6
5.6
5.0
190020
164600
215440
13.4
2.5
5.5
10.0
145460
127280
163650
12.5
2.3
5.3
15.0
112250
99162
125330
11.7
2.2
5.2
20.0
87197
77746
96649
10.8
2.1
5.1
25.0
68000
61200
74800
10.0
2.0
4.9
30.0
53307
47543
59071
10.8
2.3
4.8
35.0
42039
37183
46896
11.6
2.5
4.7
40.0
33356
29264
37448
12.3
2.7
4.6
45.0
26599
23152
30046
13.0
2.9
4.5
50.0
21332
18424
24240
13.6
3.1
4.3
55.0
17230
14769
19691
14.3
3.4
4.2
60.0
13984
11899
16070
14.9
3.6
4.1
65.0
11398
9629
13168
15.5
3.8
4.1
70.0
9334
7829
10839
16.1
4.1
4.0
75.0
7669
6389
8950
16.7
4.3
3.9
80.0
6328
5236
7420
17.3
4.6
3.8
85.0
5248
4314
6182
17.8
4.8
3.7
90.0
4370
3569
5171
18.3
5.1
3.6
95.0
3650
2962
4338
18.9
5.3
3.5
100.0
3060
2468
3652
19.4
5.6
3.5
105.0
2578
2067
3090
19.8
5.8
3.4
110.0
2180
1737
2623
20.3
6.1
3.3
115.0
1847
1463
2231
20.8
6.4
3.3
120.0
1569
1236
1903
21.2
6.6
3.2
125.0
1338
1048
1628
21.7
6.9
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 48 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0104J000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 100000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
12022000
9374400
14670000
22.0
3.2
6.8
50.0
8548000
6786600
10309000
20.6
3.0
6.8
45.0
6100400
4926000
7274700
19.3
2.8
6.8
40.0
4371200
3586400
5156000
18.0
2.7
6.7
35.0
3145900
2620200
3671600
16.7
2.5
6.6
30.0
2274600
1921600
2627600
15.5
2.4
6.4
25.0
1649000
1411900
1886000
14.4
2.3
6.3
20.0
1207100
1046800
1367300
13.3
2.1
6.2
15.0
884550
776440
992660
12.2
2.0
6.0
10.0
654460
581120
727800
11.2
1.9
5.9
5.0
488520
438560
538490
10.2
1.8
5.7
0.0
367810
333650
401960
9.3
1.7
5.6
5.0
279440
256030
302850
8.4
1.5
5.5
10.0
213910
197870
229960
7.5
1.4
5.3
15.0
165070
154080
176060
6.7
1.3
5.2
20.0
128230
120740
135720
5.8
1.2
5.1
25.0
100000
95000
105000
5.0
1.0
4.9
30.0
78393
73836
82950
5.8
1.2
4.8
35.0
61822
57772
65873
6.6
1.4
4.7
40.0
49053
45489
52618
7.3
1.6
4.6
45.0
39116
36002
42229
8.0
1.8
4.5
50.0
31371
28663
34078
8.6
2.0
4.3
55.0
25338
22987
27690
9.3
2.2
4.2
60.0
20565
18527
22604
9.9
2.4
4.1
65.0
16762
14998
18526
10.5
2.6
4.1
70.0
13726
12200
15253
11.1
2.8
4.0
75.0
11279
9959
12598
11.7
3.0
3.9
80.0
9305
8165
10446
12.3
3.2
3.8
85.0
7718
6730
8706
12.8
3.5
3.7
90.0
6426
5569
7283
13.3
3.7
3.6
95.0
5368
4624
6111
13.9
3.9
3.5
100.0
4500
3854
5145
14.4
4.1
3.5
105.0
3792
3229
4354
14.8
4.4
3.4
110.0
3206
2715
3697
15.3
4.6
3.3
115.0
2716
2287
3145
15.8
4.8
3.3
120.0
2308
1933
2683
16.2
5.1
3.2
125.0
1968
1640
2296
16.7
5.3
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 49 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0104K000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 100000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
12022000
8773300
15271000
27.0
4.0
6.8
50.0
8548000
6359200
10737000
25.6
3.8
6.8
45.0
6100400
4621000
7579800
24.3
3.6
6.8
40.0
4371200
3367900
5374600
23.0
3.4
6.7
35.0
3145900
2462900
3828900
21.7
3.3
6.6
30.0
2274600
1807900
2741300
20.5
3.2
6.4
25.0
1649000
1329500
1968500
19.4
3.1
6.3
20.0
1207100
986430
1427700
18.3
3.0
6.2
15.0
884550
732210
1036900
17.2
2.9
6.0
10.0
654460
548400
760530
16.2
2.8
5.9
5.0
488520
414130
562920
15.2
2.7
5.7
0.0
367810
315260
420350
14.3
2.6
5.6
5.0
279440
242050
316820
13.4
2.5
5.5
10.0
213910
187170
240660
12.5
2.3
5.3
15.0
165070
145830
184310
11.7
2.2
5.2
20.0
128230
114330
142130
10.8
2.1
5.1
25.0
100000
90000
110000
10.0
2.0
4.9
30.0
78393
69916
86870
10.8
2.3
4.8
35.0
61822
54681
68964
11.6
2.5
4.7
40.0
49053
43036
55071
12.3
2.7
4.6
45.0
39116
34046
44185
13.0
2.9
4.5
50.0
31371
27094
35647
13.6
3.1
4.3
55.0
25338
21720
28957
14.3
3.4
4.2
60.0
20565
17498
23632
14.9
3.6
4.1
65.0
16762
14160
19365
15.5
3.8
4.1
70.0
13726
11514
15939
16.1
4.1
4.0
75.0
11279
9395
13162
16.7
4.3
3.9
80.0
9305
7699
10911
17.3
4.6
3.8
85.0
7718
6344
9092
17.8
4.8
3.7
90.0
6426
5248
7605
18.3
5.1
3.6
95.0
5368
4356
6380
18.9
5.3
3.5
100.0
4500
3629
5370
19.4
5.6
3.5
105.0
3792
3039
4544
19.8
5.8
3.4
110.0
3206
2555
3858
20.3
6.1
3.3
115.0
2716
2152
3281
20.8
6.4
3.3
120.0
2308
1818
2798
21.2
6.6
3.2
125.0
1968
1541
2395
21.7
6.9
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 50 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0154J000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 150000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
18033000
14062000
22005000
22.0
3.2
6.8
50.0
12822000
10180000
15464000
20.6
3.0
6.8
45.0
9150500
7389000
10912000
19.3
2.8
6.8
40.0
6556900
5379600
7734100
18.0
2.7
6.7
35.0
4718900
3930300
5507500
16.7
2.5
6.6
30.0
3411900
2882400
3941400
15.5
2.4
6.4
25.0
2473400
2117900
2829000
14.4
2.3
6.3
20.0
1810600
1570200
2051000
13.3
2.1
6.2
15.0
1326800
1164700
1489000
12.2
2.0
6.0
10.0
981690
871680
1091700
11.2
1.9
5.9
5.0
732790
657830
807740
10.2
1.8
5.7
0.0
551710
500480
602940
9.3
1.7
5.6
5.0
419150
384040
454270
8.4
1.5
5.5
10.0
320870
296800
344940
7.5
1.4
5.3
15.0
247600
231120
264080
6.7
1.3
5.2
20.0
192350
181120
203580
5.8
1.2
5.1
25.0
150000
142500
157500
5.0
1.0
4.9
30.0
117590
110750
124430
5.8
1.2
4.8
35.0
92733
86657
98809
6.6
1.4
4.7
40.0
73580
68233
78927
7.3
1.6
4.6
45.0
58673
54003
63344
8.0
1.8
4.5
50.0
47056
42995
51117
8.6
2.0
4.3
55.0
38008
34480
41535
9.3
2.2
4.2
60.0
30848
27790
33906
9.9
2.4
4.1
65.0
25143
22497
27790
10.5
2.6
4.1
70.0
20589
18300
22879
11.1
2.8
4.0
75.0
16918
14939
18897
11.7
3.0
3.9
80.0
13958
12247
15669
12.3
3.2
3.8
85.0
11577
10094
13059
12.8
3.5
3.7
90.0
9639
8354
10925
13.3
3.7
3.6
95.0
8052
6936
9167
13.9
3.9
3.5
100.0
6749
5781
7718
14.4
4.1
3.5
105.0
5688
4843
6532
14.8
4.4
3.4
110.0
4809
4073
5546
15.3
4.6
3.3
115.0
4074
3431
4717
15.8
4.8
3.3
120.0
3462
2900
4024
16.2
5.1
3.2
125.0
2952
2460
3444
16.7
5.3
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 51 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0154K000
R/T No.
2005
T (
C)
B
25/100
= 4600 K, R
25
= 150000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
18033000
13160000
22906000
27.0
4.0
6.8
50.0
12822000
9538700
16105000
25.6
3.8
6.8
45.0
9150500
6931400
11370000
24.3
3.6
6.8
40.0
6556900
5051800
8061900
23.0
3.4
6.7
35.0
4718900
3694300
5743400
21.7
3.3
6.6
30.0
3411900
2711800
4112000
20.5
3.2
6.4
25.0
2473400
1994200
2952700
19.4
3.1
6.3
20.0
1810600
1479700
2141500
18.3
3.0
6.2
15.0
1326800
1098300
1555300
17.2
2.9
6.0
10.0
981690
822600
1140800
16.2
2.8
5.9
5.0
732790
621190
844380
15.2
2.7
5.7
0.0
551710
472890
630530
14.3
2.6
5.6
5.0
419150
363080
475230
13.4
2.5
5.5
10.0
320870
280750
360980
12.5
2.3
5.3
15.0
247600
218740
276460
11.7
2.2
5.2
20.0
192350
171500
213200
10.8
2.1
5.1
25.0
150000
135000
165000
10.0
2.0
4.9
30.0
117590
104870
130310
10.8
2.3
4.8
35.0
92733
82021
103450
11.6
2.5
4.7
40.0
73580
64554
82606
12.3
2.7
4.6
45.0
58673
51070
66277
13.0
2.9
4.5
50.0
47056
40642
53470
13.6
3.1
4.3
55.0
38008
32580
43436
14.3
3.4
4.2
60.0
30848
26247
35448
14.9
3.6
4.1
65.0
25143
21240
29047
15.5
3.8
4.1
70.0
20589
17271
23908
16.1
4.1
4.0
75.0
16918
14093
19743
16.7
4.3
3.9
80.0
13958
11549
16367
17.3
4.6
3.8
85.0
11577
9515
13638
17.8
4.8
3.7
90.0
9639
7872
11407
18.3
5.1
3.6
95.0
8052
6534
9569
18.9
5.3
3.5
100.0
6749
5443
8056
19.4
5.6
3.5
105.0
5688
4559
6816
19.8
5.8
3.4
110.0
4809
3832
5787
20.3
6.1
3.3
115.0
4074
3227
4921
20.8
6.4
3.3
120.0
3462
2727
4197
21.2
6.6
3.2
125.0
2952
2312
3592
21.7
6.9
3.1
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 52 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0224J000
R/T No.
2007
T (
C)
B
25/100
= 4830 K, R
25
= 220000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
40891000
31538000
50244000
22.9
2.7
8.4
50.0
27110000
21313000
32908000
21.4
2.7
8.1
45.0
18235000
14595000
21875000
20.0
2.6
7.8
40.0
12440000
10126000
14753000
18.6
2.5
7.5
35.0
8593400
7107200
10080000
17.3
2.4
7.3
30.0
6010700
5046400
6975000
16.0
2.3
7.0
25.0
4251800
3620700
4882800
14.8
2.2
6.8
20.0
3041000
2624700
3457300
13.7
2.1
6.6
15.0
2200300
1923500
2477100
12.6
2.0
6.4
10.0
1607500
1422400
1792600
11.5
1.8
6.2
5.0
1176000
1052700
1299300
10.5
1.7
6.1
0.0
868650
786150
951160
9.5
1.6
5.9
5.0
651090
595460
706720
8.5
1.5
5.7
10.0
491880
454380
529390
7.6
1.4
5.6
15.0
374010
348820
399210
6.7
1.2
5.4
20.0
286460
269620
303300
5.9
1.1
5.3
25.0
220000
209000
231000
5.0
1.0
5.2
30.0
170630
160650
180620
5.9
1.2
5.0
35.0
133120
124290
141940
6.6
1.4
4.9
40.0
104500
96785
112200
7.4
1.5
4.8
45.0
82574
75881
89266
8.1
1.7
4.7
50.0
65610
59830
71390
8.8
1.9
4.6
55.0
52279
47316
57242
9.5
2.1
4.5
60.0
41891
37636
46145
10.2
2.3
4.4
65.0
33782
30134
37430
10.8
2.5
4.3
70.0
27372
24246
30499
11.4
2.7
4.2
75.0
22289
19607
24970
12.0
3.0
4.1
80.0
18229
15929
20529
12.6
3.2
4.0
85.0
14961
12987
16934
13.2
3.4
3.9
90.0
12327
10632
14022
13.7
3.6
3.8
95.0
10203
8745
11662
14.3
3.8
3.7
100.0
8477
7221
9733
14.8
4.0
3.7
105.0
7077
5992
8162
15.3
4.3
3.6
110.0
5929
4991
6868
15.8
4.5
3.5
115.0
4985
4171
5798
16.3
4.7
3.4
120.0
4205
3498
4911
16.8
5.0
3.4
125.0
3564
2949
4179
17.3
5.2
3.3
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 53 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0224K000
R/T No.
2007
T (
C)
B
25/100
= 4830 K, R
25
= 220000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
40891000
29494000
52289000
27.9
3.3
8.4
50.0
27110000
19957000
34263000
26.4
3.3
8.1
45.0
18235000
13684000
22787000
25.0
3.2
7.8
40.0
12440000
9504100
15375000
23.6
3.1
7.5
35.0
8593400
6677600
10509000
22.3
3.1
7.3
30.0
6010700
4745900
7275600
21.0
3.0
7.0
25.0
4251800
3408100
5095400
19.8
2.9
6.8
20.0
3041000
2472600
3609300
18.7
2.8
6.6
15.0
2200300
1813500
2587100
17.6
2.7
6.4
10.0
1607500
1342000
1872900
16.5
2.6
6.2
5.0
1176000
993860
1358100
15.5
2.6
6.1
0.0
868650
742720
994590
14.5
2.5
5.9
5.0
651090
562900
739280
13.5
2.4
5.7
10.0
491880
429780
553980
12.6
2.3
5.6
15.0
374010
330120
417910
11.7
2.2
5.4
20.0
286460
255290
317620
10.9
2.1
5.3
25.0
220000
198000
242000
10.0
1.9
5.2
30.0
170630
152120
189150
10.9
2.2
5.0
35.0
133120
117640
148590
11.6
2.4
4.9
40.0
104500
91560
117430
12.4
2.6
4.8
45.0
82574
71752
93395
13.1
2.8
4.7
50.0
65610
56550
74671
13.8
3.0
4.6
55.0
52279
44702
59856
14.5
3.3
4.5
60.0
41891
35542
48239
15.2
3.5
4.4
65.0
33782
28445
39119
15.8
3.7
4.3
70.0
27372
22877
31868
16.4
3.9
4.2
75.0
22289
18493
26084
17.0
4.2
4.1
80.0
18229
15017
21441
17.6
4.4
4.0
85.0
14961
12239
17682
18.2
4.7
3.9
90.0
12327
10016
14638
18.7
4.9
3.8
95.0
10203
8235
12172
19.3
5.2
3.7
100.0
8477
6797
10157
19.8
5.4
3.7
105.0
7077
5638
8516
20.3
5.7
3.6
110.0
5929
4694
7165
20.8
5.9
3.5
115.0
4985
3922
6048
21.3
6.2
3.4
120.0
4205
3288
5121
21.8
6.5
3.4
125.0
3564
2771
4358
22.3
6.7
3.3
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 54 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0334J000
R/T No.
2006
T (
C)
B
25/100
= 5000 K, R
25
= 330000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
66183000
50630000
81736000
23.5
2.7
8.7
50.0
43235000
33741000
52729000
22.0
2.6
8.3
45.0
28767000
22873000
34660000
20.5
2.6
7.9
40.0
19466000
15753000
23180000
19.1
2.5
7.6
35.0
13380000
11008000
15751000
17.7
2.4
7.3
30.0
9329800
7796900
10863000
16.4
2.3
7.1
25.0
6599100
5596900
7601300
15.2
2.2
6.9
20.0
4716400
4056400
5376400
14.0
2.1
6.7
15.0
3415500
2976700
3854200
12.8
2.0
6.5
10.0
2495300
2202300
2788200
11.7
1.9
6.3
5.0
1826300
1631300
2021300
10.7
1.7
6.1
0.0
1348400
1218200
1478600
9.7
1.6
6.0
5.0
1002300
915460
1089200
8.7
1.5
5.8
10.0
751080
693130
809030
7.7
1.4
5.7
15.0
567210
528670
605760
6.8
1.2
5.5
20.0
431440
405950
456930
5.9
1.1
5.4
25.0
330000
313500
346500
5.0
0.9
5.3
30.0
254060
239120
269000
5.9
1.1
5.2
35.0
196480
183350
209610
6.7
1.3
5.1
40.0
152930
141520
164330
7.5
1.5
4.9
45.0
119880
110030
129720
8.2
1.7
4.8
50.0
94500
86050
102950
8.9
1.9
4.7
55.0
74646
67443
81849
9.6
2.1
4.6
60.0
59313
53183
65443
10.3
2.3
4.5
65.0
47453
42232
52673
11.0
2.5
4.4
70.0
38147
33703
42590
11.6
2.7
4.3
75.0
30788
27009
34567
12.3
2.9
4.2
80.0
24955
21740
28171
12.9
3.1
4.1
85.0
20334
17593
23075
13.5
3.3
4.1
90.0
16637
14298
18975
14.1
3.5
4.0
95.0
13705
11702
15709
14.6
3.8
3.9
100.0
11337
9618
13056
15.2
4.0
3.8
105.0
9413
7936
10891
15.7
4.2
3.7
110.0
7845
6574
9117
16.2
4.5
3.6
115.0
6551
5456
7646
16.7
4.7
3.6
120.0
5489
4544
6433
17.2
4.9
3.5
125.0
4625
3807
5443
17.7
5.2
3.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 55 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0334K000
R/T No.
2006
T (
C)
B
25/100
= 5000 K, R
25
= 330000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
66183000
47321000
85045000
28.5
3.3
8.7
50.0
43235000
31579000
54891000
27.0
3.3
8.3
45.0
28767000
21435000
36098000
25.5
3.2
7.9
40.0
19466000
14779000
24153000
24.1
3.2
7.6
35.0
13380000
10339000
16420000
22.7
3.1
7.3
30.0
9329800
7330400
11329000
21.4
3.0
7.1
25.0
6599100
5266900
7931300
20.2
2.9
6.9
20.0
4716400
3820600
5612200
19.0
2.9
6.7
15.0
3415500
2806000
4025000
17.8
2.8
6.5
10.0
2495300
2077500
2913000
16.7
2.7
6.3
5.0
1826300
1540000
2112700
15.7
2.6
6.1
0.0
1348400
1150800
1546000
14.7
2.5
6.0
5.0
1002300
865340
1139300
13.7
2.3
5.8
10.0
751080
655580
846580
12.7
2.2
5.7
15.0
567210
500310
634120
11.8
2.1
5.5
20.0
431440
384370
478500
10.9
2.0
5.4
25.0
330000
297000
363000
10.0
1.9
5.3
30.0
254060
226420
281700
10.9
2.1
5.2
35.0
196480
173530
219440
11.7
2.3
5.1
40.0
152930
133870
171980
12.5
2.5
4.9
45.0
119880
104040
135720
13.2
2.7
4.8
50.0
94500
81325
107680
13.9
2.9
4.7
55.0
74646
63711
85581
14.6
3.2
4.6
60.0
59313
50217
68409
15.3
3.4
4.5
65.0
47453
39860
55046
16.0
3.6
4.4
70.0
38147
31796
44497
16.6
3.8
4.3
75.0
30788
25469
36107
17.3
4.1
4.2
80.0
24955
20492
29419
17.9
4.3
4.1
85.0
20334
16577
24092
18.5
4.6
4.1
90.0
16637
13467
19807
19.1
4.8
4.0
95.0
13705
11017
16394
19.6
5.1
3.9
100.0
11337
9051
13623
20.2
5.3
3.8
105.0
9413
7465
11361
20.7
5.6
3.7
110.0
7845
6181
9510
21.2
5.8
3.6
115.0
6551
5128
7974
21.7
6.1
3.6
120.0
5489
4270
6707
22.2
6.4
3.5
125.0
4625
3576
5675
22.7
6.6
3.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 56 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0474J000
R/T No.
2006
T (
C)
B
25/100
= 5000 K, R
25
= 470000
, T
R
= 25
C,
R
R
/R
R
=
5%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
94260000
72109000
116410000
23.5
2.7
8.7
50.0
61577000
48056000
75099000
22.0
2.6
8.3
45.0
40971000
32577000
49364000
20.5
2.6
7.9
40.0
27725000
22436000
33013000
19.1
2.5
7.6
35.0
19056000
15678000
22434000
17.7
2.4
7.3
30.0
13288000
11105000
15471000
16.4
2.3
7.1
25.0
9398700
7971300
10826000
15.2
2.2
6.9
20.0
6717300
5777300
7657300
14.0
2.1
6.7
15.0
4864500
4239600
5489300
12.8
2.0
6.5
10.0
3553900
3136600
3971100
11.7
1.9
6.3
5.0
2601100
2323400
2878900
10.7
1.7
6.1
0.0
1920400
1735000
2105900
9.7
1.6
6.0
5.0
1427600
1303800
1551300
8.7
1.5
5.8
10.0
1069700
987190
1152200
7.7
1.4
5.7
15.0
807850
752950
862750
6.8
1.2
5.5
20.0
614470
578170
650770
5.9
1.1
5.4
25.0
470000
446500
493500
5.0
0.9
5.3
30.0
361840
340570
383120
5.9
1.1
5.2
35.0
279840
261140
298540
6.7
1.3
5.1
40.0
217800
201560
234050
7.5
1.5
4.9
45.0
170740
156710
184760
8.2
1.7
4.8
50.0
134590
122560
146630
8.9
1.9
4.7
55.0
106310
96055
116570
9.6
2.1
4.6
60.0
84476
75745
93207
10.3
2.3
4.5
65.0
67584
60149
75019
11.0
2.5
4.4
70.0
54330
48002
60658
11.6
2.7
4.3
75.0
43849
38467
49232
12.3
2.9
4.2
80.0
35543
30963
40122
12.9
3.1
4.1
85.0
28961
25057
32864
13.5
3.3
4.1
90.0
23695
20364
27025
14.1
3.5
4.0
95.0
19520
16667
22373
14.6
3.8
3.9
100.0
16147
13699
18595
15.2
4.0
3.8
105.0
13407
11303
15511
15.7
4.2
3.7
110.0
11174
9362
12985
16.2
4.5
3.6
115.0
9330
7771
10890
16.7
4.7
3.6
120.0
7817
6472
9162
17.2
4.9
3.5
125.0
6587
5422
7753
17.7
5.2
3.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 57 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
B57164K0474K000
R/T No.
2006
T (
C)
B
25/100
= 5000 K, R
25
= 470000
, T
R
= 25
C,
R
R
/R
R
=
10%
R
nom
[
]
R
min
[
]
R
max
[
]
R
R
/R
R
[
%]
T[
C]
(%/K)
55.0
94260000
67396000
121120000
28.5
3.3
8.7
50.0
61577000
44977000
78178000
27.0
3.3
8.3
45.0
40971000
30529000
51412000
25.5
3.2
7.9
40.0
27725000
21050000
34399000
24.1
3.2
7.6
35.0
19056000
14725000
23387000
22.7
3.1
7.3
30.0
13288000
10440000
16135000
21.4
3.0
7.1
25.0
9398700
7501400
11296000
20.2
2.9
6.9
20.0
6717300
5441500
7993100
19.0
2.9
6.7
15.0
4864500
3996400
5732600
17.8
2.8
6.5
10.0
3553900
2958900
4148800
16.7
2.7
6.3
5.0
2601100
2193300
3008900
15.7
2.6
6.1
0.0
1920400
1639000
2201900
14.7
2.5
6.0
5.0
1427600
1232500
1622700
13.7
2.3
5.8
10.0
1069700
933700
1205700
12.7
2.2
5.7
15.0
807850
712560
903140
11.8
2.1
5.5
20.0
614470
547440
681500
10.9
2.0
5.4
25.0
470000
423000
517000
10.0
1.9
5.3
30.0
361840
322480
401210
10.9
2.1
5.2
35.0
279840
247140
312530
11.7
2.3
5.1
40.0
217800
190670
244940
12.5
2.5
4.9
45.0
170740
148180
193300
13.2
2.7
4.8
50.0
134590
115830
153360
13.9
2.9
4.7
55.0
106310
90739
121890
14.6
3.2
4.6
60.0
84476
71521
97431
15.3
3.4
4.5
65.0
67584
56770
78398
16.0
3.6
4.4
70.0
54330
45285
63375
16.6
3.8
4.3
75.0
43849
36274
51424
17.3
4.1
4.2
80.0
35543
29186
41900
17.9
4.3
4.1
85.0
28961
23609
34312
18.5
4.6
4.1
90.0
23695
19180
28210
19.1
4.8
4.0
95.0
19520
15691
23349
19.6
5.1
3.9
100.0
16147
12891
19402
20.2
5.3
3.8
105.0
13407
10632
16181
20.7
5.6
3.7
110.0
11174
8804
13544
21.2
5.8
3.6
115.0
9330
7304
11356
21.7
6.1
3.6
120.0
7817
6081
9553
22.2
6.4
3.5
125.0
6587
5093
8082
22.7
6.6
3.4
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 58 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
Cautions and warnings
General
See "Important notes" at the end of this document.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature
25
C ... +45
C, relative
humidity
75% annual mean, maximum 95%, dew precipitation is inadmissible.
Do not store SMDs where they are exposed to heat or direct sunlight. Otherwise, the packing
material may be deformed or SMDs may stick together, causing problems during mounting.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environments like corrosive gases (SOx, Cl etc).
After opening the factory seals, such as polyvinyl-sealed packages, use the SMDs as soon as
possible.
Solder thermistors after shipment from EPCOS within the time specified:
SMDs: 12 months
Leaded components: 24 months
Handling
NTC thermistors must not be dropped. Chip-offs must not be caused during handling of NTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering
Use resin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Mounting
When NTC thermistors are encapsulated with sealing material or overmolded with plastic
material, the precautions given in chapter "Mounting instructions", "Sealing, potting and
overmolding" must be observed.
Electrode must not be scratched before/during/after the mounting process.
Contacts and housings used for assembly with thermistor have to be clean before mounting.
During operation, the thermistor's surface temperature can be very high (ICL). Ensure that
adjacent components are placed at a sufficient distance from the thermistor to allow for proper
cooling ot the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can
withstand this temperature.
Make sure that thermistors (ICLs) are adequately ventilated to avoid overheating.
Avoid contamination of thermistor surface during processing.
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 59 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
Operation
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified voltage and current ranges (ICLs).
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be
ensured that no water enters the NTC thermistor (e.g. through plug terminals). For
measurement purposes (checking the specified resistance vs. temperature), the component
must not be immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by malfunction (e.g. use VDR for limitation of overvoltage condition).
Temperature measurement
B57164
Leaded NTCs, lead spacing 5 mm
K164
Page 60 of 61
Please read Important notes and
Cautions and warnings at the end of this document.
The following applies to all products named in this publication:
1.
Some parts of this publication contain statements about the suitability of our products for
certain areas of application
. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application
.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2.
We also point out that in individual cases, a malfunction of passive electronic compon-
ents or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified
. In customer applica-
tions requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3.
The warnings, cautions and product-specific notes must be observed.
4.
In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as "hazardous")
. Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5.
We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time
. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an or-
der.
We also reserve the right to discontinue production and delivery of products. Con-
sequently, we cannot guarantee that all products named in this publication will always be
available.
6.
Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI)
.
7.
The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will
be found on the Internet at www.epcos.com/trademarks.
Important notes