DC/DC power module
2.5 V / 4.4 A / 11W
The MacroDensTM PKF 4919B I true component level
on-board DC/DC power modules are intended
as distributed power sources in decentralized 48 and
60VDC power systems.
The over-moulded rugged design also makes them
suitable for other demanding industrial applications.
They are optimized for an operational ambient
temperature range in compliance with present and
SMD package with ultra low
component height 8.0 mm (0.315 in.)
83% efficiency at full load
1,500 Vdc isolation voltage
Synchronous rectification
MTTF >10 million hours at +50C case
temperature
Low EMI
PKF 4919B I
E
future application needs, including non temperature
controlled environments. The mechanical design
offers a surface mount version, delivered in
ready-to-use tubes, trays or tape & reel package, and
compatibility with semi and fully aqueous cleaning
processes.
For mechanical and other information please refer to the
PKF series General information data sheet.
Patents Pending
2
EN/LZT 146 98 R1A Ericsson Microelectronics AB, June 2001
Stress in excess of Absolute Maximum
Ratings may cause permanent damage.
Absolute Maximum Ratings, sometimes
referred to as no destruction limits, are nor-
mally tested with one parameter at a
time exceeding the limits of Output data
or Electrical Characteristics. If exposed to
stress above these limits, function and per-
formance may degrade in an unspecified
manner.
Connections
Absolute Maximum Ratings
Characteristics
Isolation voltage
(input to output test voltage)
V
ISO
min
max
Unit
T
C
Case temperature at full output power
45
+100
C
T
S
Storage temperature
55
+125
C
V
I
Continuous input voltage
1)
0.5
+75
V dc
1,500
V dc
E
tr
Transient input energy
0.10
Ws
V
RC
Remote control voltage pin 11 ref. to pin 17
5
+16
V dc
V
adj
Output adjust voltage pin 8 ref. to pin 17
5
+40
V dc
NOTES:
1)
The input voltage range 36...75 V dc meets
the European Telecom Standard prETS
300 132-2 Nominal input voltage range in
48 V and 60 V dc power systems,
40.5... 57.0 V and 50.0... 72.0 V
respectively. Absolute max continuous input
voltage is 75 V dc.
2)
The power modules will operate down to
35V, when V
I
decreases, but will turn on at
V
I
36V, when V
I
increases (see also Operating
information).
Input T
C
<T
Cmax
unless otherwise specified
mW
mW
Input stand-by power
P
RC
V
I
Input voltage range
1)2)
36
75
V
V
Ioff
Turn-off input voltage
30.0
35.0
V
33.0
See typical characteristics
V
Ion
Turn-on input voltage
36.0
V
34.5
See typical characteristics
C
I
Input capacitance
mF
1.4
P
Ii
Input idling power
I
O
= 0, T
C
= 30...+ 95 C
(V
I
= 53V)
(V
I
= 66V)
600
700
(V
I
= 53V)
(V
I
= 66V)
40
60
T
C
= 30...+ 95 C,
RC connected to pin 17
Characteristics
Conditions
min
typ
max
Unit
32.0
Pin
Designation
Function
1
Out 1
Output 1(+)
2
Rtn
Output return.
3
Out 1
Output 1(+), Preferred output.
4-7
N C
Not connected. Galvanically isolated from other pins.
8
V
adj
Output voltage adjust.
9-10
N C
Not connected.
11
RC
Remote control and turn-on/off input voltage adjust
1216
N C
Not connected. Galvanically isolated from other pins.
17
In
Negative input.
18
+In
Positive input.
18 17 16 15 14 13 12 11 10
1
2
3
4
5
6
7
8
9
Note: Galvanic isolation is verified in an electric strength test. Test voltage is 1,500 Vdc for 60 s.
In final test however, duration is decreased to 1s. Pin 1 and 3 must be connected for optimum
performance.
3
EN/LZT 146 98 R1A Ericsson Microelectronics AB, June 2001
Fundamental circuit diagram
Single output
Electrical Data
Safety
The PKF 4919B I DC/DC power module is designed in accordance
with EN 60 950, Safety of information technology equipment including
electrical business equipment
.
The PKF power modules are recognized by UL and meet the applica-
ble requirements in UL 1950 Safety of information technology equipment,
the applicable Canadian safety requirements and UL 1012 Standard for
power supplies
.
The DC/DC power module shall be installed in an end-use equip-
ment and considerations should be given to measuring the case
temperature to comply with T
Cmax
when in operation. Abnormal
component tests are conducted with the input protected by an
external 15 A fuse. The need for repeating these tests in the end-use
appliance shall be considered if installed in a circuit having higher
rated devices.
When the supply to the DC/DC power module meets all the require-
ments for SELV (<60Vdc), the output is considered to remain within
SELV limits (level 3). The isolation is an operational insulation in
accordance with EN 60 950.
The DC/DC power module is intended to be supplied by isolated
secondary circuitry and shall be installed in compliance with the re-
quirements of the ultimate application. If they are connected to a
60 V DC system reinforced insulation must be provided in the power
supply that isolates the input from the mains. Single fault testing in
the power supply must be performed in combination with the
DC/DC power module to demonstrate that the output meets the re-
quirement for SELV. One pole of the input and one pole of the output
is to be grounded or both are to be kept floating.
The terminal pins are only intended for connection to mating connec-
tors of internal wiring inside the end-use equipment.
These DC/DC power modules may be used in telephone equipment in
accordance with paragraph 34 A.1 of UL 1459 (Standard for Telephone
Equipment, second edition).
The galvanic isolation is verified in an electric strength test. Test
voltage (V
ISO
) between input and output is 1,500 Vdc for 60 s. In
production the test duration may be decreased to 1 s.
The capacitor between input and output has a value of 2.2 nF and
the leakage current is less than 1A @ 53 Vdc.
The case is designed in non-conductive epoxy. Its flammability
rating meets UL 94V-0. The oxygen index is 34%.
Transient input voltage
Single voltage pulse at +25C ambient temperature.
4
EN/LZT 146 98 R1A Ericsson Microelectronics AB, June 2001
T
C
= 30...+95 C, V
I
= 36 ...75 V.
0
4.4
A
Characteristics
Conditions
Output 1
min
typ
max
Unit
Output voltage initial
setting and accuracy
V
Oi
Output voltage
tolerance band
V
O
Idling voltage
I
O
= 0 A
Load regulation
I
O
= 0...4.4 A, V
I
= 53 V
t
tr
Load transient voltage
V
tr
Temperature coefficient
2)
T
coeff
t
r
Start-up time
t
s
I
O
Max output power
2)
P
Omax
Current limiting
threshold
I
lim
T
C
<T
Cmax
, V
O
= 2.2 V
Short circuit current
I
sc
V
O
= 0.2...0.5V, T
C
= +25C
20 Hz...5 MHz
Line regulation
I
O
= 4.4 A
Load transient
recovery time
2.43
2.50
2.56
V
2.36
2.5
2.65
V
7
230
mV
0.2 mV/C
2
ms
6
ms
11 W
5.9
A
6.5
A
20
50
mV
p-p
60
ms
2.39
2.61
V
Long term drift
included
Output
V
I
= 36...60 V
Output adjust range
1)
2.20
2.80
V
60
dB
1)
See also Operating Information
2)
See Typical Characteristics
T
C
= +25C, I
O
= 3.5 A, V
I
= 53 V
Ramp-up time
Output current
2)
I
O
= 3 A
Output ripple & noise
V
Oac
f = 100 Hz sine wave, 1V
p-p
, V
I
= 53 V
(SVR = 20 log (1 V
p-p
/V
Op-p
))
I
O
= 0.3...4.4...A
,
V
I
= 53 V
From V
I
connection to V
O
= 0.9 V
Oi
I
O
=
0.3-4.4...A,
0.1...0.9 V
Oi
, V
I
= 53 V
SVR
Supply voltage rejection (ac)
V
I
= 55...75 V
0
mV
Calculated value
30
mV
I
O
= 0.4...4.4 A
I
O
= 0.4...4.0 A , Pin1
2.32
2.61
V
30
75
mV
p-p
0.4...50 MHz
I
O
= 4.4 A
20 Hz...5 MHz
80
dB
mV
3.2
Characteristics
Conditions
Unit
min
typ
max
P
d
Power dissipation
Miscellaneous
%
Efficiency
h
I
O
= 4.4 A
78
83
V
I
= 53 V
V
I
= 60 V
V
I
= 53 V
V
I
= 66 V
78
83
3.2
W
I
O
= 0.3...4.4 A
,
V
I
= 53 V
load step= 2.0A
I
O
= 4.4 A, T
C
= 40...+90
O
C
5
EN/LZT 146 98 R1A Ericsson Microelectronics AB, June 2001
Typical Characteristics
Output characteristic (typ)
Power derating
Temperature coefficient
Turn-on/turn-off input voltage
Efficiency (typ)
@ T
A
= +25C
Current derating
Dynamic load response (typ) @ +25C
0
0.6
1.2
1.8
2.5
3.1
3.7
4.3
5
70
73
76
80
83
86
90
Efficiency (%)
36 V
75 V
Load Current (A)
-50 -40 -30 +80 +90 +100 +110 +120
Output voltage (V)
Case temperature (C)
0
3
6
9
12
-40
-22.5 -5.0
12.5
30.0
47.5
65.0
82.5
100
2.39
2.42
2.46
2.50
2.53
2.57
2.61
Output voltage (V)
Case temperature (C)
V
I
= 53V. Loadstep 2.4 4.4 A
The output
voltage
deviation is
determined
by the load
transient
(dl/dt)
Load change:
(dl/dt) 4A/s
3.90
4.00
4.10
4.20
4.30
4.40
4.50
2.2
2.5
Output voltage (V) initial setting
Load curr
ent (A)
2.8
0
1
2
3
4
5
6
2.39
2.42
2.46
2.50
2.53
2.57
2.61
Output voltage (V)
Load current (A)
-30.0 -14.3
1.2
16.8
32.5
48.1
63.7
79.3
95
32.0
32.5
33.0
33.5
34.0
34.5
35.0
Turn-on
Turn-off
Turn-on/Tur-off voltage
Case temperature (C)