ChipFind - документация

Электронный компонент: PKL4110APIP

Скачать:  PDF   ZIP
Advanced Specification
50A - 60A DC/DC Power Module
48V Input, 3.3V Output
The PKL 4000 series represents another one of
Ericsson's "industry first" achievements in the con-
tinuing development of our "Third Generation" of
high-density, high-efficiency power modules. The
PKL 4110A PI module packs 68W/in
3
at 92%
efficiency (3.3V @ 60A) in an half-brick footprint
that has been enhanced to include two additional
output pins for motherboard connection reliability at
this high power.
These breakthrough features come from using the
most advanced patented topology utilizing inte-
grated magnetics and synchronous rectification on a
low-resistivity multilayer PCB.
This product features fast dynamic response times
and low output ripple, which are important
parameters when supplying low-voltage logics.
High Efficiency, 92% Typ
High Power Density, 68 W/in
3
(3.3V @
60A)
Fast Dynamic Response, 200 ms,
250 mVpeak Typ.
Low Output Ripple, 70mVp-p Typ.
Wide input voltage range (36-75V)
1,500 V dc isolation voltage
Max. case temperature +100C
UL 1950/UL
C
1950 Recognized
TUV to EN 60950 Type Approved
Demonstrated compliance with
isolation requirements equivalent to
Basic Insulation per UL 60950
Patent Pending Paralleling Feature
Heatsinks available as an option for
extended operation
E
The PKL 4000 PI Series also is especially well suited
for limited board space and high dynamic load
applications.
Ericsson's PKL 4000 Series Power Modules address
the converging "New Telecom" market, by specifying
the input voltage range in accor-dance with ETSI
specifications. The PKL 4000 Series also offers over-
voltage protection, under-voltage protection, over-
temperature protection, soft-start, paralleling, and
short circuit protection.
These modules are manufactured on highly
automated manufacturing lines. Ericsson's world-
class quality commitment is reflected in our standard
five year warranty. Ericsson Inc., Power Modules
has been an ISO 9001 certified Suplier since 1991.
For a complete product program, please reference the back
page.
PKL 4110A PI / PKL 4110 PI
2
EN/LZT 108 5167 R1 Ericsson Inc., Power Modules , November 2002
General
Mechanical Data
08EN/
2.42
[61,5] OVERALL LENGTH
2.042
[51,86]
0.400
[10,16]
2.00
[50,8]
1.400
[35,56]
1.000
[25,40]
0.50
[12,72]
0.20
[5,1]
-INPUT
CASE
REMOTE
ON/OFF
+INPUT
2.40
[61,0]
OVERALL
WIDTH
0.19
[4,82]
-OUTPUT
-SENSE
TRIM
+SENSE
+OUTPUT
0.137
[3,47]
0.332
[8,42]
0.50
[12,72
0.400
[10,16]
0.700
[17,78]
1.000
[25,40]
1.400
[35,56]
0.21
[5,3]
PIN
EXT.
0.50
[12,7]
OVERALL
HEIGHT
0.040 [1,02] DIA. PLATED
BRASS PINS
TYPICAL 7 PLACES
0.080 [2,06] DIA. PLATED
BRASS PINS
TYPICAL 4 PLACES
M3 X [0,5] MOUNTING INSERTS
TYPICAL 4 PLACES
MAX. SCREW TORQUE: 3.9 IN-LBS.[0,44 N-M]
Dimensions: inches [mm]
Tolerances: .xx 0.02 [ ,x ,5]
.xxx 0.010 [,xx ,25]
BOTTOM VIEW
I
I max
Max. Input V
i
= V
i
min = 36 V PKL 4110A PI 6.5 A
dc
Current
PKL 4110 PI 5.5
Input
T
C
<T
Cmax
unless otherwise specified
Weight
Pins
110 grams
Case
Aluminum base plate with metal standoffs.
Pin Material: Brass
Pin Plating: Tin/Lead over Nickel
V
I
Input voltage
range
36
75
V
d c
V
Ioff
Turn-off input
voltage
31
V
d c
33
Ramping from higher
voltage
V
Ion
Turn-on input
voltage
36
V
d c
34
Characteristics
Conditions
min
typ max
Units
Ramping from lower
voltage
Connections
Pin Designation
Function
1
-INPUT
Negative input
2
CASE
Connected to base plate
3
REMOTE
Remote control (primary) to
ON/OFF
turn-on and turn-off the output
4
+INPUT
Positive input.
5, 10
-OUTPUT
Negative output (two pins)
6
-SENSE
Negative remote sense
7
TRIM
Output voltage adjust
8
+SENSE
Positive remote sense
9, 11
+OUTPUT
Positive output (two pins)
Note: If the remote sense is not needed the "-Sense" should be
connected to "-Out" and the "+Sense" should be
connected to "+Out."
W
W
Input stand-by
power
P
RC
C
I
Input capacitance
F
P
Ii
Input idling
power
I
O
= 0 , T
C
=30...+95C
6
0.4
T
C
=30...+95C,
RC Open
Inrush Current
3.5
I
I rush
Except Charging of C
I
A
dc
1
0.6
3
EN/LZT 108 5167 R1 Ericsson Inc., Power Modules, November 2002
Absolute Maximum Ratings
PKL 4110A PI / PKL 4110 PI
T
C
= 40...+100C, V
I
= 36...75V unless otherwise specified.
Output
All 200
s
Conditions
Output voltage initial
setting and accuracy
T
C
=+25C, V
I
= 53 V, I
O
=I
Omax
V
Oi
Output voltage
tolerance band
V
O
Load regulation
V
I
= 53V, I
O
=0
to I
Omax
,
V
t r
Load transient
recovery time
t
t r
Line regulation
I
O
=I
Om a x
Load transient
voltage deviation
All 3.25 3.3 3.35 V
I
O
=0 to I
Omax
Output adjust range
Load step = 0.25 x I
Omax
di/dt = 1A/us
I
O
=I
Omax
Characteristics
Output
min typ max
Unit
Supply voltage
rejection (ac)
Output current
I
O
Max output power
P
Omax
Current limit threshold
I
lim
V
O
= 0.96 V
Onom
@ T
C
<100
o
C
Short circuit current
I
sc
V
I
= 53V,
Output ripple & noise
OVP
All 70 150 mV
p-p
V
Oa c
All 3.9 4.4 5.0 V
I
O
=I
Omax, f < 20 MHz
At V
O
= V
Onom
All 10 15 ms
Start-up time
t
s
From V
I
connection to V
O
= 0.9
V
Onom
Device
All 2.64 3.63 V
All 3.2 3.4 V
All 5 15 mV
All 5 15 mV
All +/-250 mV
A
PKL 4110A PI 0 60
PKL 4110 PI 0 50
W
PKL 4110A PI 198
PKL 4110 PI 165
A
PKL 4110A PI 61.0 64.8 72.0
PKL 4110 PI 51.0 54.5 62.0
A
PKL 4110A PI 65 74
PKL 4110 PI 55 64
f < 1kHz
SVR
All -50 dB
Over voltage protection
Stress in excess of Absolute Maximum Ratings may cause permanent
damage. Absolute Maximum Ratings, sometimes referred to as "no
destruction limits," are normally tested with one parameter at a time
exceeding the limits of output data or electrical characteristics. If exposed
to stress above these limits, function and performance may degrade in an
unspecified manner.
T
C
Maximum Operating Case Temperature 40 +100 C
T
S
Storage temperature
40 +125 C
V
I
Input voltage: Continuous 0.5 +80 V dc
V
I S O
1,500 V dc
12 Vdc
Characteristics
min max Unit
Isolation voltage
(input to output test voltage)
I
2
t
Inrush transient
1 A
2
s
V
RC
Remote control voltage
Transient (100ms) +100 V dc
Miscellaneous
Characteristics
Conditions
f
S
Switching frequency
I
O
= 0...1.0 x I
Omax
All
150 kHz
Efficiency
I
O
= I
Omax
, V
I
= 53V, T
C
= +25
o
C
All
92
%
P
d
Power dissapation
I
O
= I
Omax
, V
I
= 53V, T
C
= +25
o
C
Unit
Device
min typ max
W
PKL 4110A PI 17.2
PKL 4110 PI 14.3
Typical Characteristics
PKL 4110A PI & PKL 4110 PI Efficiency
84.0%
85.0%
86.0%
87.0%
88.0%
89.0%
90.0%
91.0%
92.0%
93.0%
94.0%
95.0%
0
10
20
30
40
50
60
Output Current (A)
Efficiency (%)
36V
53V
72V
4
EN/LZT 108 5167 R1b Ericsson Inc., Power Modules , November 2002
Ericsson Inc.,
Power Modules
1700 International Pkwy.
Richardson, Texas 75081
Phone: 877-374-2642
www.ericsson.com/powermoduless
EN/LZT 108 5167 R1b
Ericsson Inc., Power Modules, November, 2002
Preliminary
Advanced Specification
The latest and most complete
information can be found on our website!
The PKL 4000 DC/DC power modules will be
available with the different options listed in the
Product Options Table
Please check with the factory for availability.
Information given in this Advanced Specification is believed to be accurate
and reliable. No responsibility is assumed for the consequences of its use
for any infringement of patents or other rights of third parties that may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of Ericsson Power Modules. These products are
sold only according to Ericsson Power Modules' general conditions of
sale, unless otherwise confirmed in writing. Specifications are subject to
change without notice.
V
I
V
O
/I
O
P
O
max Ordering Number
Product Program
48/60V 3.3V/60A 198W PKL 4110A PI
48/60V 3.3V/50A 165W PKL 4110 PI
Negative remote on/off - PKL 4110A PI
logic
Positive remote on/off logic P PKL 4110A PIP
Lead length 0.145"
0.010" LA PKL 4110A PILA
Industry Standard Trim T PKL 4110A PIT
Product Options