ChipFind - документация

Электронный компонент: 40CPV120

Скачать:  PDF   ZIP
120 & 240 Vac Models
0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary
function modules provide control of the
phased turn-on of a solid state relay, in
response to the application of a 0-5 Vdc
control signal. They must be used with
FastFax Document No. 203
SERIES CPV.040898, PAGE 1 OF 2
Crydom Series 1 (-10) random turn-on
solid state relays. Consult factory about
use with 480 Vac loads. For a com-
plete set (control module and solid state
relay) order 10CPV120, 25CPV120, etc.
Manufactured in Crydom's ISO 9002
Certified facility for optimum product
performance and reliability.
Series CPV
Phase Control Modules
M O D E L N U M B E R S
120 Vac
10CPV120
25CPV120
40CPV120
240 Vac
10CPV240
25CPV240
50CPV240
75CPV240
90CPV240
RELAY OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz) [Vrms]
90-140 (120 Vac Models)
180-280 (240 Vac Models)
Load Current Range
[Arms]
.04-10
.04-25
.04-50
.04-75
.04-90
Transient Overvoltage [Vpk]
400 (120 Vac models)
600 (240 Vac models)
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case [R
JC] C/W
1.48
1.02
0.63
0.31
0.28
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10.0
10.0
10.0
10.0
10.0
Min. Off-State dv/dt @ Max. Rated Voltage [V/sec]
500
500
500
500
500
Max. Turn-On Time [msec]
0.02
0.02
0.02
0.02
0.02
Max. Turn-Off Time
1
/
2
cycle
1
/
2
cycle
1
/
2
cycle
1
/
2
cycle
1
/
2
cycle
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
CONTROL MODULE INPUT SPECIFICATIONS
DC CONTROL
Logic Supply Range (Terminal 3A)
3.5-10Vdc
Typical Supply Current
1.6mA @ 5Vdc
Control Voltage Range (Terminal 3B)
0-5 Vdc
Nominal Control Input Impedance
1500 Ohms
Min. Turn-Off Voltage
1.0
CONTROL MODULE OUTPUT (Terminal 4B Input to Relay)
Max. Off-State Operating Voltage
36 Vdc
Max. Load Current (Sink)
3.0 mA
Max. On-State Voltage @ 3mA
0.5 Vdc
Max. Off-State Leakage @ 10Vdc
1.0 Adc
GENERAL NOTES
All parameters at 25C unless otherwise specified.
Off-State dv/dt test method per
EIA/NARM standard RS-443,
paragraph 13.11.1
Heat sinking required (Relay Only),
see Series 1 data sheet.
1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 (619) 715-7200 fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
FASTON TERMINAL
.250 X .032
4 PLCS.
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.87
(22.2)
.270 (2)
(6.9)
.50
(12.7)
1.10
(27.9)
1.00
(25.4)
1.80
(45.7)
.270
(6.9)
FASTON
TERMINAL
.187 X .032
4 PLCS.
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
4000 Vrms
Dielectric Strength, Signal to Base
4000 Vrms
Ambient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-40 to 125C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (43g)
Encapsulation:
Thermally Conductive Epoxy
All dimensions are in inches (millimeters)
Series CPV
Phase Control Modules
DERATING CURVES
See Series 1
Positive
Supply (+)
(5Vdc)
Control
Voltage (+)
(0 to 5Vdc)
Common ()
Line
Load
Notes
1. Following pins may be interchanged: 1A & 1B, 2A & 2B.
2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B.
3. The line and load may be interchanged.
10 RELAY
1
2
4
3
CONTROL MODULE
1A 1B
2B 2A
4A 4B
3B 3A
OUTPUT
INPUT
+
--
AVAILABLE OPTIONS
CPV120 Control Module Only (120 Vac line)
CPV240 Control Module Only (120 Vac line)
FastFax Document No. 203
SERIES CPV.040898, PAGE 2 OF 2
1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 (619) 715-7200 fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany