Description
Time Delay surface mount fuse capable of replacing
glass tube fuses in certain applications
Environmentally rugged, complies with EIA-IS-722
Standard
Solder Immersion Compatible
Targeted for Consumer Electronics
Agency Information
UL Recognition Guide & File numbers: JDYX2 & E19180.
CSA Component Acceptance: 053787 C 000 & Class
No: 1422 30.
Environmental Data
Life Test: MIL-STD-202, Method 108A, Test Condition D
Load Humidity: MIL-STD-202, Method 103B
Moisture Resistance: MIL-STD-202, Method 106E
Thermal Shock: MIL-STD-202, Method 107D, air-to-air
Case Resistance: EIA/IS-722
Resistance to Dissolution of Metallization:
ANSI J-STD-002, Test D
Mechanical Shock: MIL-STD-202, Method 213B, Test
Condition A
High Frequency Vibration: MIL-STD-202, Method 204D,
Test Condition D
Resistance to Solvents: MIL-STD-202, Method 215A
Ordering
Specify product code and packaging code
Soldering Method
Wave Immersion: 260C, 3 sec max.
Infrared: 260C, 30 sec max.
2.6
3.0
(0.102)
(0.118)
4.0
(0.157)
8.6
(0.338)
Land Pattern
Dimensions
mm
/
(inches)
Brick
TM
Fuses
6125TD Series, Time Delay
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
200%
1 Second Minimum
200%
2-4 Seconds Typical
200%
60 Seconds Maximum
SPECIFICATIONS
Product
Voltage
Interrupting
DC Cold
Typical
Typical
Code
Rating
Rating*
Resistance** (ohms)
Melting
Voltage
AC DC
125VAC 60VDC
min.
typ.
max.
I
2
t
Drop
6125TD500mA
125V 60V
50A 50A
.3350 .4025 .4700
0.716
245 mV
6125TD750mA
125V 60V
50A 50A
.2000 .2350 .2700
1.07
250 mV
6125TD1A
125V 60V
50A 50A
.1350 .1680 .2000
2.88
256 mV
6125TD1.5A
125V 60V
50A 50A
.0550 .0630 .0700
2.35
125 mV
6125TD2A
125V 60V
50A 50A
.0380 .0480 .0580
9.45
133 mV
6125TD2.5A
125V 60V
50A 50A
.0280 .0350 .0420
16.2
130 mV
6125TD3A
125V 60V
50A 50A
.0225 .0263 .0300
15.3
97 mV
6125TD3.5A
125V 60V
50A 50A
.0170 .0195 .0220
14.5
95 mV
6125TD4A
125V 60V
50A 50A
.0160 .0185 .0210
38.8
106 mV
6125TD5A
125V 60V
50A 50A
.0115 .0133 .0150
34.4
100 mV
6125TD7A
125V 60V
50A 50A
.0073 .0087 .0100
90.2
99 mV
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than
50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
Typical Melting I
2
t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)
Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.
TIME CURRENT CURVE
Brick
TM
Fuses
6125TD Series, Time Delay
250mA and 375mA
to be determined
Visit us on the Web at www.cooperET.com
3601 Quantum Boulevard Boynton Beach, Florida 33426-8638
Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper
Electronic Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of
any products. Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this
bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
OC-2530 Rev. M 5/03
Cooper Electronic
Technologies 2003
PACKAGING CODE
Packaging Code
Description
SP2
50 piece sample
TR1
Standard Package: (This is an insert)
1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481