Frequency/Rate Meter
K3NR
K-129
Panel
indicators
Frequency/Rate Meter
K3NR
High-speed, Intelligent Interface Modules
with Seven Operating Modes Convert Single
or Dual Input Pulses to Display Values
50-kHz input range and 0.006% accuracy for sophisticated
control.
A wide selection of outputs: relay, transistor, BCD, linear, or
communications.
Maximum/Minimum value hold, set value write protection, and
more.
Banks with four comparative output values and four prescale
values.
Prescale function available, which displays in units of actual
physical parameters (length, volume, etc.).
Set value teaching, linear output range teaching, and prescale
teaching are available using actual measured values.
Displays values in hours, minutes, and seconds in operating
mode 6.
A startup compensation time parameter keeps the
measurement operation from sending an unnecessary output
for a preset period up to 99.9 s.
Built-in sensor power supply (12 VDC, 80 mA).
Compact 1/8 DIN size.
Conforms to EMC standards, EN61010-1 (IEC61010-1).
UL/CSA approved.
Model Number Structure
I Model Number Legend
Base Units and Output Boards can be ordered individually or as sets. Refer to the Output Board Combinations table on page 130.
1, 2. Input Sensors Codes
NB:
NPN inputs/Voltage pulse inputs
PB:
PNP inputs
3. Supply Voltage
1:
100 to 240 VAC
2:
12 to 24 VDC
4. Display
A:Basic
C:Set Value LED Display
5, 6, 7, 8. Output Type Codes
C1:
3 comparative relay contact outputs (H, PASS, L: SPDT)
C2:
5 comparative relay contact outputs (HH, H, L, LL: SPST-
NO; PASS: SPDT)
C5:
5 comparative relay contact outputs (HH, H, L, LL: SPST-
NC; PASS: SPDT)
T1:
5 comparative transistor outputs (NPN open collector)
T2:
5 comparative transistor outputs (PNP open collector)
B2:
BCD output (NPN open collector) (see note)
B4:
BCD output + 5 transistor outputs (NPN open collector)
L1:
Linear output (4 to 20 mA) (see note)
L2:
Linear output (1 to 5 VDC) (see note)
L3:
Linear output (1 mV/10 digits) (see note)
L4:
Linear output, 4 to 20 mA + 5 transistor outputs (NPN open
collector)
L5:
Linear output, 1 to 5 V + 5 transistor outputs (NPN open col-
lector)
L6:
Linear output, 1 mV/10 digits+ 5 transistor outputs (NPN
open collector)
L7:
Linear output, 0 to 5 VDC (see note)
L8:
Linear output, 0 to 10 VDC (see note)
L9:
Linear output, 0 to 5 VDC + 5 transistor outputs (NPN open
collector)
L10: Linear output, 0 to 10 VDC + 5 transistor outputs (NPN open
collector)
FLK1: Communication RS-232C (see note)
FLK2: Communication RS-485 (see note)
FLK3: Communication RS-422 (see note)
FLK4: RS-232C + 5 transistor outputs (NPN open collector)
FLK5: RS-485 + 5 transistor outputs (NPN open collector)
FLK6: RS-422 + 5 transistor outputs (NPN open collector)
Note: These output types are available on Basic Models only.
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
Base Units with Output Boards
K3NR -
Base Units
Output Boards
K3NR - -
K31 -
K-130
Frequency/Rate Meter
K3NR
Ordering Information
I Base Unit
I Available Output Board Combinations
Note: For details, refer to the Communication Operation Manual.
Input type
NPN/Voltage pulse
PNP
Supply voltage
100 to 240 VAC
12 to 24 VDC
100 to 240 VAC
12 to 24 VDC
K3NR-NB1A
K3NR-NB2A
K3NR-PB1A
K3NR-PB2A
K3NR-NB1C
K3NR-NB2C
K3NR-PB1C
K3NR-PB2C
Output type
Output configuration
Output boards
Base units
Basic
Set Value
LED Display
Relay contact
3 outputs: H, PASS, L (SPDT)
K31-C1
Yes
Yes
5 outputs: HH, H, L, LL (SPST-NO), and PASS (SPDT)
K31-C2
Yes
Yes
5 outputs: HH, H, L, LL (SPST-NC), and PASS (SPDT)
K31-C5
Yes
Yes
Transistor
5 outputs (NPN open collector)
K31-T1
Yes
Yes
5 outputs (PNP open collector)
K31-T2
Yes
Yes
BCD (see note)
5-digit output (NPN open collector)
K31-B2
Yes
---
Linear
4 to 20 mA DC
K31-L1
Yes
---
1 to 5 VDC
K31-L2
Yes
---
1 mV/10 digits
K31-L3
Yes
---
0 to 5 VDC
K31-L7
Yes
---
0 to 10 VDC
K31-L8
Yes
---
Communication boards
(see note)
RS-232C
K31-FLK1
Yes
---
RS-485
K31-FLK2
Yes
---
RS-422
K31-FLK3
Yes
---
Combination output and
communication boards
BCD output + 5 transistor outputs (NPN open collector)
K31-B4
Yes
Yes
4 to 20 mA + 5 transistor outputs (NPN open collector)
K31-L4
Yes
Yes
1 to 5 V + 5 transistor outputs (NPN open collector)
K31-L5
Yes
Yes
1 mV/10 digits + 5 transistor outputs (NPN open collector)
K31-L6
Yes
Yes
0 to 5 VDC + 5 transistor outputs (NPN open collector)
K31-L9
Yes
Yes
0 to 10 VDC + 5 transistor outputs (NPN open collector)
K31-L10
Yes
Yes
RS-232C + 5 transistor outputs (NPN open collector)
K31-FLK4
Yes
Yes
RS-485 + 5 transistor outputs (NPN open collector)
K31-FLK5
Yes
Yes
RS-422 + 5 transistor outputs (NPN open collector)
K31-FLK6
Yes
Yes
Basic Models
These models provide a
present value LED and
front-panel control keys. Can
be connected to any Output
Board, or can be used for
display only without an
Output Board.
Set Value LED Models
These models provide a
present value LED, set
value LED, and front-panel
control keys. Can be
connected to Relay,
Transistor, or Combination
Output Boards.
Frequency/Rate Meter
K3NR
K-131
Panel
indicators
Specifications
I Ratings
Note: A K3NR with DC supply voltage requires approximately 1 A DC as control power supply current the moment the K3NR is turned ON. Do not
forget to take this into consideration when using several K3NR units. When the K3NR is not in measuring operation (e.g., the K3NR has
been just turned ON or is operating for startup compensation time), the display will read "00000" and all outputs will be OFF.
Supply voltage
100 to 240 VAC (50/60 Hz); 12 to 24 VDC
Operating voltage range
85% to 110% of supply voltage
Power consumption (see note)
15 VA max. (max. AC load with all indicators lit)
10 W max. (max. DC load with all indicators lit)
Sensor power supply
80 mA at 12 VDC
10%
Insulation resistance
20 M
min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Dielectric strength
2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Noise immunity
1,500 V on power supply terminals in normal or common mode 1 s, 100 ns for square-wave noise
with 1 ns
Vibration resistance
Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction: 98 m/s
2
for 3 times each in X, Y, and Z directions
Destruction: 294 m/s
2
for 3 times each in X, Y, and Z directions
Ambient temperature
Operating:
-10C to 55C (with no icing)
Storage:
-20C to 65C (with no icing)
Ambient humidity
Operating:
25% to 85% (with no condensation)
EMC
(EMI)
EN61326+A1
Industry
Emission Enclosure:
CISPR 11 Group 1 class A: CISRP16-1/-2
Emission AC Mains:
CISPR 11 Group 1 class A: CISRP16-1/-2
(EMS)
EN61326+A1
Industry
Immunity ESD:
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
EN61000-4-3:
10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
Immunity Fast Transient Noise:
EN61000-4-4:
2 kV (power line) (level 3)
Immunity Burst Noise:
1 kV line to line (I/O signal line)
Immunity Surge:
EN61000-4-5:
1 kV line to line
2 kV line to ground (power line)
Immunity Conducted Disturbance EN61000-4-6:
3 V (0.15 to 80 MHz) (level 2)
Immunity Voltage Dip/Interrupting EN61000-4-11:
0.5 cycles, 0, 180
, 100% (rated voltage)
Approved standards
UL508, CSA22.2;
Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.
Weight
Approx. 400 g
K-132
Frequency/Rate Meter
K3NR
I Characteristics
Note: 1. The linear output range cannot be set when connected to a 1 mV/10-digit Linear Output Board.
2. Not effective for operating mode 7.
Input signal
No-voltage contact (30 Hz max., ON/OFF pulse width: 15 ms min.)
Voltage pulse (50 kHz max., ON/OFF pulse width: 9
s min., ON voltage: 4.5 to 30 V/OFF voltage: -30 to 2 V)
Open collector (50 kHz max., ON/OFF pulse width: 9
s min.)
Connectable Sensors
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current:
Must have switching capacity of 20 mA min.
Must be able to dependably switch a load current of 5 mA max.
Measuring accuracy
(at 23
5C)
Operating modes 1 and 6:
0.006%rdg1 digit
Operating modes 2 to 5:
0.02%rdg1 digit
Measuring modes and
ranges
(Operating modes 1 to 6 are
for no-contact sensor
models)
Operating mode 1: Rotational/circumferential speed
0.0005 to 50,000 Hz
Operating mode 2: Absolute ratio
0.0005 to 50,000 Hz
Operating mode 3: Error ratio
0.0005 to 50,000 Hz
Operating mode 4: Rotational difference
0.0005 to 50,000 Hz
Operating mode 5: Flow rate ratio
0.0005 to 50,000 Hz
Operating mode 6: Passing time
0.0005 to 50,000 Hz
Operating mode 7: Pulse counting
0 to 4G count (32-bit counter)
Max. displayed digits
5 digits (
-19999 to 99999)
Display
7-segment LED
Polarity display
"
-" is displayed automatically with a negative input signal.
Zero display
Leading zeros are not displayed.
Prescale function
Programming via front-panel key inputs. (0.0001 x 10
-9
to 9.9999 x 10
9
, decimal point can be set freely)
Can be set using prescale value teaching.
HOLD functions
(see note 2)
Max. value (peak) hold, Min. value (bottom) hold
External control
HOLD (Process value held)
RESET (Maximum/minimum data reset, counting value reset)
BANK (Selection of one bank out of 4 banks of set values)
(Selection of one bank out of 4 banks of prescale values)
Comparative output
hysteresis setting
Programmable with front-panel key inputs (1 to 9999).
Other functions
Variable linear output range (for models with linear outputs only) (note 1)
Remote/Local processing (available for communications output models only)
Maximum/Minimum value data reset with front panel keys
Comparative output pattern selection
Process time for averaging measured values
Startup compensation time (0.0 to 99.9 s)
Time unit display
Security
Memory power failure
Output configuration
Relay contact output (3 or 5 outputs)
Transistor output (NPN and PNP open collector), BCD (NPN open collector)
Parallel BCD (NPN open collector) + transistor output (NPN open collector)
Linear output (4 to 20 mA, 1 to 5 V) + transistor output (NPN open collector)
Communication functions (RS-232C, RS-485, RS-422)
Communication functions (RS-232C, RS-485, RS-422) + transistor output (NPN open collector)
Delay in comparative
outputs (at transistor output)
Operating modes 1 to 6: 200 ms max.
Operating mode 7:
1 ms max.
Linear output response time Operating modes 1 to 6: 220 ms max.
Operating mode 7:
20 ms max.
Degree of protection
Front panel: NEMA4X for indoor use (equivalent to IP66)
Rear case: IEC standard IP20
Terminals:
IEC standard IP00
Memory protection
Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)
Frequency/Rate Meter
K3NR
K-133
Panel
indicators
I Input/Output Ratings
Relay Contact Output
(Incorporating a G6B Relay)
Transistor Output
BCD Output
Note: Logic method: negative logic
Linear Output
Note: For the 1 mV/10-digit output, the output voltage changes for every 40 to 50 increment in the display value.
I Communications Specifications
For details, refer to Communication Operation Manual.
Item
Resistive load (cos
= 1)
Inductive load (cos
= 0.4, L/R = 7 ms)
Rated load
5 A at 250 VAC; 5 A at 30 VDC
1.5 A at 250 VAC, 1.5 A at 30 VDC
Rated carry current
5 A max. (at COM terminal)
Max. contact voltage
380 VAC, 125 VDC
Max. contact current
5 A max. (at COM terminal)
Max. switching capacity
1,250 VA, 150 W
375 VA, 80 W
Min. permissible load
(P level, reference value)
10 mA at 5 VDC
Mechanical life
50,000,000 times min. (at a switching frequency of 18,000 times/hr)
Electrical life
(at an ambient temperature of 23
C)
100,000 times min. (at a rated load switching frequency of 1,800 times/hr)
Rated load voltage
24 VDC max.
Max. load current
50 mA
Leakage current
100
A max.
I/O signal name
Item
Rating
Inputs
REQUEST, HOLD, MAX, MIN, RESET
Input signal
No-voltage contact input
Input current with no-voltage input
10 mA
Signal level
ON voltage: 1.5 V max.
OFF voltage: 3 V min.
Outputs
DATA, POLARITY, OVERFLOW,
DATA VALID, RUN
Rated load voltage
24 VDC max.
Max. load current
10 mA
Leakage current
100
A max.
Item
4 to 20 mA
1 to 5 V
1 mV/10 digits (see note)
Resolution
4,096
Output error
0.5% FS
1.5% FS
Permissible load resistance
600
max.
500
min.
1 K
min.
Item
RS-232C, RS-422
RS-485
Transmission method
4-wire, half-duplex
2-wire, half-duplex
Synchronization method
Start-stop synchronization
Baud rate
1,200/2,400/4,800/9,600/19,200/38,400 bps
Transmission code
ASCII (7-bit)
Communications
Write
Comparative set value, prescaling value, remote/local programming, reset control of maximum/mini-
mum values, and other setting mode items excluding communications conditions.
Read
Process value, comparative set value, maximum value, minimum value, model data, error code, and
others