ChipFind - документация

Электронный компонент: DCXL01GN

Скачать:  PDF   ZIP

SURSENSE
Ultra Low Pressure Sensors
Millivolt Output
High Accuracy Compensation
Full Scale Pressure Ranges
DCXL Series
Sensing and Control
FEATURES
Position sensitivity to
5 mV/g, typical
Offset Warm-up drift
<
50 mV, typical
Temperature
Compensated over
0
C to +50
C
Available in Gage and
Differential Pressure
Ranges
Long Term Stability
<
100 V, typical
Combined Linearity and
Hysteresis Error
<
0.25 % Span


TYPICAL APPLICATIONS
Medical Instrumentation
HVAC
Industrial Instrumentation
Environmental Controls




WARNING
PERSONAL INJURY
DO NOT USE these products
as safety or emergency stop
devices or in any other
application where failure of the
product could result in
personal injury.
Failure to comply with these
instructions could result in
death or serious injury.
The DCXL line of ultra low pressure sensors is based upon
SURSENSE
, a proprietary technology, which reduces all output offset or
common mode errors.
These sensors use a silicon micromachined sensing element which
features a unique stress concentration enhanced structure to provide a
highly stable linear output that is proportional to applied pressure. Output
offset errors due to changes in temperature, warm-up, long term stability
and position sensitivity have all been significantly reduced when compared
to conventional sensors.
The DCXL Series sensors provide a precision calibrated ratiometric
millivolt output using the enhanced stability of SURSENSE
technology.
Each sensor features calibrated offset, full scale span and thermal error
calibration to ensure the highest possible accuracy for flow pressure
measurement. These highly stable sensors feature an industry standard
ported package with improved stress isolation for printed circuit board
mount applications.
Product is patented by US patent 6023978.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as product installation information.
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious
injury.
SURSENSE
Ultra Low Pressure Sensors
Millivolt Output
DCXL Series
2 Honeywell
Sensing and Control
DCXL Electrical Specifications at 12 Vdc Excitation, 25
C
Min.
Typ.
Max.
Units
Excitation Voltage
3.0
12.0
16.0
Vdc
Common Mode Voltage, % Excitation
--
50
--
%
Span*except DCXL01DN
19
20.0
21.0
mV
Span*DCXL01DN
9.0
10.0
11.0
mV
Null*
- 500
0
+500
V
Offset Temperature Shift (0 C to +50 C [+32 F to +122 F])**
except DCXL01DN

-150

--

+150

V
Offset Temperature Shift (0 C to +50 C [+32 F to +122 F])**
DCXL01DN

- 250

0

+250

V
Span Temperature Shift (0 C to +50 C [+32 F to +122 F])** -200
0
+200
V
Linearity, Hysteresis Error***
--
0.05
0.25
%Span
Operating Temperature
-25
+85
C
Storage Temperature
-40
+125
C
Offset Warm-up Shift****except DCXL01DN
--
50
--
V
Offset Warm-up Shift****DCXL01DN
--
100
--
V
Offset Position Sensitivity (
1g) except DCXL01DN,
DCXL05DN and DCXL10DN

--
5

--

V
Offset Position Sensitivity (
1g) DCXL01DN
--
50
--
V
Offset Position Sensitivity (
1g) DCXL05DN, DCXL10DN
--
10
--
V
Offset Long Term Stability (1 year) except DCXL01DN
--
100
--
V
Offset Long Term Stability (1 year) DCXL01DN
--
200
--
V
*Note 1:
The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 1.0 V to 6.0 V.
**Note 2:
Shift is relative to 25
C
***Note 3:
Measured at full scale rated pressure using BFSL
****Note 4:
Shift is within the first hour of excitation applied to the device.
DCXL Series Pressure Ratings in H
2
O (by Catalog Listing)
DCXL-
01D
05D
10D
20D
30D
OPERATING PRESSURE RANGE
1.0
5.0
10.0
20.0
30.0
PROOF
100
150
150
300
450
BURST
200
300
300
450
750
COMMON MODE
50
50
50
50
50
DCXL Series Resistance (by Catalog Listing)
DCXL
01D
05D
10D
20D
30D
UNIT
INPUT RESISTANCE
4.5
10
13
10
12
K
O
OUTPUT RESISTANCE
1.5
1.5
1.5
2
1.5
K
O

SURSENSE
Ultra Low Pressure Sensors
Millivolt Output
DCXL Series
Honeywell
Sensing and Control 3
MOUNTING DIMENSIONS (for reference only) mm/in
DCXL SERIES, DCXL CERAMIC PACKAGE
APPLICATION INFORMATION
MEDIA COMPATIBILITY, WETTED MATERIALS
Port 2
P2 Port: Media must be compatible
with nylon housing, epoxy adhesive
and silicon.
Port 1
P1 Port: Dry Gases Only. Media
must be compatible with epoxy
based adhesive.
Testing to Non
Standard Conditions,
changes to:
Excitation Voltage
Common mode pressure. Standard
testing has positive pressure to port
2 with ambient pressure to port 1.
Pressure Compatibility:
Measures differential or gage pressure and vacuum.
Pressure may be applied to either port. For pressure to the
low pressure port, the output polarity is reversed.
Ratiometric Output: The output voltage of the sensor is
ratiometric, proportional, to the excitation voltage. For this
model sensor, all specifications will change proportionally
to any changes in the excitation voltage. The excitation
may vary between 3vots to 16 volts. All specifications will
nominally be changed by a ratio of V EXCITATION/12.0
volts. For example: if the excitation voltage is 5.0 volts,
then both the full scale output voltage and the offset
voltage nominals would be 5/12
th
the specified value.
Equivalent Circuit
Pinout
1. N/C
2. +V Supply
3. +V Output
4. -V Supply
5. -V Output
6. N/C


SURSENSE
Ultra Low Pressure Sensors
Millivolt Output
DCXL Series
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032
Printed with Soy Ink
on 50% Recycled Paper
008055-2-EN IL50 GLO 0801 Printed in USA
Copyright
1997- 2001 by Honeywell Data Instruments Inc. All rights reserved.
www.honeywell.com/sensing
DCXL SERIES ORDER GUIDE
(
Not all product combinations are released.)
DCXL Compensated and calibrated, mV
DCXL
05
D
Pressure Reference
G - Gage
D - Differential
Pressure Range
01, 05, 10, 20, 30 inches H
2
O
N
N- Plastic
Series
Package Type

WARRANTY/REMEDY
Honeywell warrants goods of
its manufacture as being free of
defective materials and faulty
workmanship. Contact your local
sales office for warranty
information. If warranted goods
are returned to Honeywell during
the period of coverage,
Honeywell will repair or replace
without charge those items it
finds defective. The foregoing is
Buyer's sole remedy and is in
lieu of all other warranties,
expressed or implied,
including those of
merchantability and fitness for
a particular purpose.

Specifications may change
without notice. The information
we supply is believed to be
accurate and reliable as of this
printing. However, we assume
no responsibility for its use.
While we provide application
assistance personally, through
our literature and the Honeywell
web site, it is up to the customer
to determine the suitability of the
product in the application.

For application assistance,
current specifications, or name of
the nearest Authorized
Distributor, contact a nearby
sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@micro.honeywell.com