ChipFind - документация

Электронный компонент: SCXL010DN

Скачать:  PDF   ZIP

Document Outline

Microstructure Pressure Sensors
Precision Compensated
0 in H
2
O to 4 in H
2
O and 0 in H
2
O to 10 in H
2
O
SCXL Series
FEATURES
Very Low Pressure
Resolution
Precision Temperature
Compensation
Small Size
Low Noise
Calibrated Zero & Span
High Impedance for Low
Power Applications
TYPICAL APPLICATIONS
Air Flow
Respirators
The SCXL series sensors provide a very cost-effective solution for pressure
applications that require high accuracy over very low operating pressure
ranges. These internally calibrated and temperature compensated sensors
were specifically designed to provide an accurate and stable output over a
0 C to 50 C [32
F to 122 F] temperature range. This series is intended for
use with non-corrosive, non-ionic working fluids such as air, dry gases and
the like.
HVAC
Medical Equipment
Computer Peripherals
Pneumatic Controls


The output of the bridge is ratiometric to the supply voltage. Operation from
any dc supply voltage up to 18 Vdc [Model SCXL004DN] or 20 Vdc
[SCXL010DN] is acceptable.


Contact your local honeywell representative or go to Honeywell's website at
www.honeywell.com/sensing for additional details.


WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.



WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Sensing and Control
Microstructure Pressure Sensors
Precision Compensated
0 in H
2
O to 4 in H
2
O and 0 in H
2
O to 10 in H
2
O
SCXL Series
GENERAL SPECIFICATIONS

Characteristic
Description (Maximum Ratings)
SCXL004DN
Description (Maximum Ratings)
SCXL010DN
Supply Voltage (V
S)
18 Vdc
20 Vdc
Common Mode Pressure
150 in H
2
O 50
psig
Lead Soldering Temperature
(2 seconds to 4 seconds)
250 C [482
F]
250 C [482
F]
Proof Pressure
(12)
10 in H
2
O 10
psi
Burst Pressure
5 psi
200 in H
2
O
ENVIRONMENTAL SPECIFICATIONS

Characteristic
Description (Maximum Ratings)
SCXL004DN
Description (Maximum Ratings)
SCXL010DN
Compensated Operating Temperature
0 C to 50 C [32
F to 122 F]
0 C to 50 C [32
F to 122 F]
Operating Temperature
0 C to 70 C [32
F to 158 F]
-40 C to 85 C [-40
F to 185 F]
Storage Temperature
0 C to 70 C [32
F to 158 F]
-40 C to 125 C [-40
F to 257 F]
Humidity Limits
0 % to 100 % RH
0 % to 100 % RH

PRESSURE RANGE SPECIFICATIONS
Full-Scale Span
(1)
Listing
Operating Pressure
Proof Pressure
(2)
Min. Typ. Max.
SCXL004DN
0 in H
2
O to 4 in H
2
O
10 in H
2
O
38.0 mV
40.0 mV
42.0 mV
SCXL010DN
0 in H
2
O to10 in H
2
O
10 psi
19.5 mV
20.0 mV
20.5 mV
SCXL004DN PERFORMANCE CHARACTERISTICS
(3)
Characteristic Min.
Typ.
Max.
Unit
Zero Pressure Offset
(4)
-1.5 0 1.5
mV
Sensitivity
10
mV/in
H
2
O
Combined Pressure Non-Linearity and Pressure Hysteresis
(5)
0.5
1.0
%
FSS
Temperature Effect on Span 0 C -50 C [32
F to 122 F]
(6)
0.2
0.1
%
FSS
Temperature Effect on Offset 0 C -50 C [32
F to 122 F]
(6)
0.5
2.0
mV
Repeatability
(7)
0.2
%
FSS
Input Resistance
(8)
4.0
kOhm
Output Resistance
(9)
4.0
kOhm
Common Mode Voltage
(10)
5.7 6.0 6.3
Vdc
Response Time
(11)
500
Microsec.
Long Term Stability of Offset and Span
(12)
0.5
%
FSS
Position Sensitivity
0.25
mV/g
2 Honeywell
Sensing and Control
Microstructure Pressure Sensors
Precision Compensated
0 in H
2
O to 4 in H
2
O and 0 in H
2
O to 10 in H
2
O
SCXL Series

SCXL010DN PERFORMANCE CHARACTERISTICS
(3)
Characteristic Min.
Typ.
Max.
Unit
Zero Pressure Offset
(4)
-0.3
0.0
0.3
mV
Sensitivity
2
mV/in
H
2
O
Combined Pressure Non-Linearity and Pressure Hysteresis
(5)
0.2
0.5
%
FSS
Temperature Effect on Span 0 C to 50 C [32
F to 122 F]
(6)
0.2
0.1
%
FSS
Temperature Effect on Offset 0 C to 50 C [32
F to 122 F]
(6)
300
500
Microvolts
Repeatability
(7)
0.2
0.5
%
FSS
Input Resistance
(8)
4.0
kOhm
Output Resistance
(9)
4.0
kOhm
Common Mode Voltage
(10)
5.8 6.0 6.2 Vdc
Response Time
(11)
100
Microsec.
Long Term Stability of Offset and Span
(12)
100
Microvolts
SPECIFICATION NOTES
Note 1:
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Note 2:
Proof pressure is the pressure above which devices will not return to guaranteed specifications.
Note 3:
Reference Conditions: (Unless otherwise noted)
T
A
= 25 C, Supply V
S
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to
Port B. For absolute devices only,
pressure is applied to Port A, and the output polarity is reversed.
Note 4:
Zero pressure effect is measured with pins pointed towards the ground. Offset can be position sensitive.
Note 5:
Pressure Hysteresis the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure.
Note 6:
Maximum error band of the offset voltage and the error band of the span, relative to the 25 C [77 F] reading.
Note 7:
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 C to 50 C
[32 F to 122 F] after:
004DN: a) 100 temperature cycles, 0 C to 50 C [32 F to 122 F]
b) 1 million pressure cycles, 0 psi to Full-Scale Span.
010DN: a) 1,000 temperature cycles, 0 C to 50 C [32 F to 122 F]
b) 1.5 million pressure cycles, 0 psi to Full-Scale Span.
Note 8:
Input resistance is the resistance between pins 2 and 4.
Note 9:
Output resistance is the resistance between pins 3 and 5.
Note 10:
Common Mode voltage of the output arms (Pins 3 and 5) for V
S
=12 Vdc.
Note 11:
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Note 12:
Long term stability over a one-year period.

ORDERING INFORMATION
Description Part
Number
0 in H
2
O to 4 in H
2
O SCXL
004DN
0 in H
2
O to 10 in H
2
O SCXL
010DN
Special Options: Pins with N-90 = 90 Lead Bend
ELECTRICAL CONNECTION
Pinout
SCXL004DN [0 in H
2
O to 4 in H
2
O]
SCXL004DN [0 in H
2
O to 10 in H
2
O]
PIN 1) Temperature output (+)
PIN 2) V
s
PIN 3) + Output
PIN 4) Ground
PIN 5) - Output
PIN 6) Temperature output (-)
PIN 1) No Connection
PIN 2) V
s
PIN 3) + Output
PIN 4) Ground
PIN 5) - Output
PIN 6) No Connection
Honeywell
Sensing and Control 3
Microstructure Pressure Sensors
Precision Compensated
0 in H
2
O to 4 in H
2
O and 0 in H
2
O to 10 in H
2
O
SCXL Series
Sensing and Control
www.honeywell.com/sensing
PHYSICAL DIMENSIONS for Reference Only-(mm/in)

WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being
free of defective materials and faulty workmanship.
Contact your local sales office for warranty information. If
warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace
without charge those items it finds defective.
The
foregoing is Buyer's sole remedy and is in lieu of all
other warranties, expressed or implied, including
those of merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.

While we provide application assistance personally,
through our literature and the Honeywell web site, it is up
to the customer to determine the suitability of the product
in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008102-1-EN IL50 GLO 1203 Printed in USA
Copyright 2003 Honeywell International Inc. All Rights Reserved