ChipFind - документация

Электронный компонент: 72V281

Скачать:  PDF   ZIP
1
2001 Integrated Device Technology, Inc.
DSC-4513/1
APRIL 2001
3.3 VOLT CMOS SuperSync FIFOTM
65,536 x 9
131,072 x 9
IDT72V281
IDT72V291
SuperSyncFIFO is a trademark and the IDT logo is a registered trademark of Integrated Device Technology, Inc.
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
.EATURES:




Choose among the following memory organizations:
IDT72V281
65,536 x 9
IDT72V291
131,072 x 9




Pin-compatible with the IDT72V261/72V271 SuperSync FIFOs




10ns read/write cycle time (6.5ns access time)




Fixed, low first word data latency time




Auto power down minimizes standby power consumption




Master Reset clears entire FIFO




Partial Reset clears data, but retains programmable
settings




Retransmit operation with fixed, low first word data
latency time




Empty, Full and Half-Full flags signal FIFO status




Programmable Almost-Empty and Almost-Full flags, each flag can
default to one of two preselected offsets




Program partial flags by either serial or parallel means




Select IDT Standard timing (using
EF
EF
EF
EF
EF and FF
FF
FF
FF
FF flags) or First Word
Fall Through timing (using
OR
OR
OR
OR
OR and IR
IR
IR
IR
IR flags)




Output enable puts data outputs into high impedance state




Easily expandable in depth and width




Independent Read and Write clocks (permit reading and writing
simultaneously)




Available in the 64-pin Thin Quad Flat Pack (TQFP) and the 64-pin
Slim Thin Quad Flat Pack (STQFP)




High-performance submicron CMOS technology
Industrial Temperature Range (-40C to + 85C) is available
DESCRIPTION:
The IDT72V281/72V291 are exceptionally deep, high speed, CMOS
First-In-First-Out (FIFO) memories with clocked read and write controls.
These FIFOs offer numerous improvements over previous SuperSync
FIFOs, including the following:




The limitation of the frequency of one clock input with respect to the other has
been removed. The Frequency Select pin (FS) has been removed, thus
it is no longer necessary to select which of the two clock inputs, RCLK or
WCLK, is running at the higher frequency.




The period required by the retransmit operation is now fixed and short.




The first word data latency period, from the time the first word is written to an
empty FIFO to the time it can be read, is now fixed and short. (The variable
clock cycle counting delay associated with the latency period found on
previous SuperSync devices has been eliminated on this SuperSync family.)
.UNCTIONAL BLOCK DIAGRAM
INPUT REGISTER
OUTPUT REGISTER
RAM ARRAY
65,536 x 9
131,072 x 9
FLAG
LOGIC
FF
/
IR
PAF
EF
/
OR
PAE
HF
READ POINTER
READ
CONTROL
LOGIC
WRITE CONTROL
LOGIC
WRITE POINTER
RESET
LOGIC
WEN
WCLK
D
0
-D
8
LD
MRS
REN
RCLK
OE
Q
0
-Q
8
OFFSET REGISTER
PRS
FWFT/SI
SEN
RT
4513 drw 01
2
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
PIN CON.IGURATIONS
TQFP (PN64-1, order code: PF)
STQFP (PP64-1, order code: TF)
TOP VIEW
DESCRIPTION (Continued)
NOTES:
1. DC = Don't Care. Must be tied to GND or V
CC
, cannot be left open.
2. This pin may either be tied to ground or left open.
3. DNC = Do Not Connect.
PIN 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
WEN
SEN
DC
(1)
V
CC
V
CC
GND
(2)
GND
(2)
GND
(2)
GND
(2)
GND
(2)
GND
(2)
GND
(2)
GND
(2)
GND
(2)
D8
D7
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
DNC
(3)
DNC
(3)
GND
DNC
(3)
DNC
(3)
V
CC
DNC
(3)
DNC
(3)
DNC
(3)
GND
DNC
(3)
DNC
(3)
Q8
Q7
Q6
GND
WCLK
PRS
MRS
LD
FWFT/SI
GND
FF
/
IR
PAF
HF
V
CC
PAE
EF
/
OR
RCLK
REN
RT
OE
Q5
Q4
V
CC
Q3
Q2
GND
Q1
Q0
GND
D0
D1
D2
D3
D4
D5
D6
4513 drw 02
SuperSync FIFOs are particularly appropriate for network, video, telecommu-
nications, data communications and other applications that need to buffer large
amounts of data.
The input port is controlled by a Write Clock (WCLK) input and a Write
Enable (
WEN) input. Data is written into the FIFO on every rising edge of
WCLK when
WEN is asserted. The output port is controlled by a Read
Clock (RCLK) input and Read Enable (
REN) input. Data is read from the
FIFO on every rising edge of RCLK when
REN is asserted. An Output
Enable (
OE) input is provided for three-state control of the outputs.
The frequencies of both the RCLK and the WCLK signals may vary from 0
to f
MAX
with complete independence. There are no restrictions on the frequency
of the one clock input with respect to the other.
There are two possible timing modes of operation with these devices:
IDT Standard mode and First Word Fall Through (FWFT) mode.
In IDT Standard mode, the first word written to an empty FIFO will not
appear on the data output lines unless a specific read operation is
performed. A read operation, which consists of activating
REN and
enabling a rising RCLK edge, will shift the word from internal memory to the
data output lines.
3
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
DESCRIPTION (Continued)
Figure 1. Block Diagram of Single 65,536 x 9 and 131,072 x 9 Synchronous FIFO
DATA OUT (Q
0
- Q
n
)
DATA IN (D
0
- D
n
)
MASTER RESET (
MRS
)
READ CLOCK (RCLK)
READ ENABLE (
REN
)
OUTPUT ENABLE (
OE
)
EMPTY FLAG/OUTPUT READY (
EF
/
OR
)
PROGRAMMABLE ALMOST-EMPTY (
PAE
)
WRITE CLOCK (WCLK)
WRITE ENABLE (
WEN
)
LOAD (
LD
)
FULL FLAG/INPUT READY (
FF
/
IR
)
PROGRAMMABLE ALMOST-FULL (
PAF
)
IDT
72V281
72V291
PARTIAL RESET (
PRS
)
FIRST WORD FALL THROUGH/SERIAL INPUT
(FWFT/SI)
RETRANSMIT (
RT
)
4513 drw 03
HALF-FULL FLAG (
HF
)
SERIAL ENABLE(
SEN
)
In FWFT mode, the first word written to an empty FIFO is clocked directly
to the data output lines after three transitions of the RCLK signal. A
REN
does not have to be asserted for accessing the first word. However,
subsequent words written to the FIFO do require a LOW on
REN for
access. The state of the FWFT/SI input during Master Reset determines the
timing mode in use.
For applications requiring more data storage capacity than a single FIFO
can provide, the FWFT timing mode permits depth expansion by chaining
FIFOs in series (i.e. the data outputs of one FIFO are connected to the
corresponding data inputs of the next). No external logic is required.
These FIFOs have five flag pins,
EF/OR (Empty Flag or Output
Ready),
FF/IR (Full Flag or Input Ready), HF (Half-full Flag), PAE
(Programmable Almost-Empty flag) and
PAF (Programmable Almost-Full
flag). The
EF and FF functions are selected in IDT Standard mode. The
IR and OR functions are selected in FWFT mode. HF, PAE and PAF are
always available for use, irrespective of timing mode.
PAE and PAF can be programmed independently to switch at any
point in memory. (See Table 1 and Table 2.) Programmable offsets
determine the flag switching threshold and can be loaded by two methods:
parallel or serial. Two default offset settings are also provided, so that
PAE
can be set to switch at 127 or 1,023 locations from the empty boundary and
the
PAF threshold can be set at 127 or 1,023 locations from the full
boundary. These choices are made with the
LD pin during Master Reset
.
For serial programming,
SEN together with LD on each rising edge
of WCLK, are used to load the offset registers via the Serial Input (SI). For
parallel programming,
WEN together with LD on each rising edge of
WCLK, are used to load the offset registers via D
n
.
REN together with LD on
each rising edge of RCLK can be used to read the offsets in parallel from Q
n
regardless of whether serial or parallel offset loading has been selected.
During Master Reset (
MRS) the following events occur: The read and
write pointers are set to the first location of the FIFO. The FWFT pin selects
IDT Standard mode or FWFT mode. The
LD pin selects either a partial flag
default setting of 127 with parallel programming or a partial flag default
setting of 1,023 with serial programming. The flags are updated according
to the timing mode and default offsets selected.
The Partial Reset (
PRS) also sets the read and write pointers to the first
location of the memory. However, the timing mode, partial flag program-
ming method, and default or programmed offset settings existing before
Partial Reset remain unchanged. The flags are updated according to the
timing mode and offsets in effect.
PRS is useful for resetting a device in
mid-operation, when reprogramming partial flags would be undesirable.
The Retransmit function allows data to be reread from the FIFO more
than once. A LOW on the
RT input during a rising RCLK edge initiates a
retransmit operation by setting the read pointer to the first location of the
memory array.
If, at any time, the FIFO is not actively performing an operation, the chip
will automatically power down. Once in the power down state, the standby
supply current consumption is minimized. Initiating any operation (by
activating control inputs) will immediately take the device out of the power
down state.
The IDT72V281/72V291 are fabricated using IDT's high speed submi-
cron CMOS technology.
4
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
PIN DESCRIPTION
Symbol
Name
I/O
Description
D
0
D
8
Data Inputs
I
Data inputs for a 9-bit bus.
MRS
Master Reset
I
MRS initializes the read and write pointers to zero and sets the output register to
all zeroes. During Master Reset, the FIFO is configured for either FWFT or IDT
Standard mode, one of two programmable flag default settings, and serial or
parallel programming of the offset settings.
PRS
Partial Reset
I
PRS initializes the read and write pointers to zero and sets the output register to
all zeroes. During Partial Reset, the existing mode (IDT or FWFT), programming
method (serial or parallel), and programmable flag settings are all retained.
RT
Retransmit
I
RT asserted on the rising edge of RCLK initializes the READ pointer to zero, sets
the
EF flag to LOW (OR to HIGH in FWFT mode) temporarily and does not disturb
the write pointer, programming method, existing timing mode or programmable flag
settings.
RT is useful to reread data from the first physical location of the FIFO.
FWFT/SI
First Word Fall
I
During Master Reset, selects First Word Fall Through or IDT Standard mode.
Through/Serial In
After Master Reset, this pin functions as a serial input for loading offset registers
WCLK
Write Clock
I
When enabled by
WEN, the rising edge of WCLK writes data into the FIFO and
offsets into the programmable registers for parallel programming, and when
enabled by
SEN, the rising edge of WCLK writes one bit of data into the
programmable register for serial programming.
WEN
Write Enable
I
WEN enables WCLK for writing data into the FIFO memory and offset registers.
RCLK
Read Clock
I
When enabled by
REN, the rising edge of RCLK reads data from the FIFO
memory and offsets from the programmable registers.
REN
Read Enable
I
REN enables RCLK for reading data from the FIFO memory and offset registers.
OE
Output Enable
I
OE controls the output impedance of Q
n.
SEN
Serial Enable
I
SEN enables serial loading of programmable flag offsets.
LD
Load
I
During Master Reset,
LD selects one of two partial flag default offsets (127 or 1,023
and determines the flag offset programming method, serial or parallel. After
Master Reset, this pin enables writing to and reading from the offset registers.
DC
Don't Care
I
This pin must be tied to either V
CC
or GND and must not toggle after Master
Reset.
FF/IR
Full Flag/
O
In the IDT Standard mode, the
FF function is selected. FF indicates whether or
Input Ready
not the FIFO memory is full. In the FWFT mode, the
IR function is selected. IR
indicates whether or not there is space available for writing to the FIFO memory.
EF/OR
Empty Flag/
O
In the IDT Standard mode, the
EF function is selected. EF indicates whether or
Output Ready
not the FIFO memory is empty. In FWFT mode, the
OR function is selected.
OR indicates whether or not there is valid data available at the outputs.
PAF
Programmable
O
PAF goes LOW if the number of words in the FIFO memory is more than
Almost-Full Flag
total word capacity of the FIFO minus the full offset value m, which is stored in the
Full Offset register. There are two possible default values for m: 127 or 1,023.
PAE
Programmable
O
PAE goes LOW if the number of words in the FIFO memory is less than offset n,
Almost-Empty Flag
which is stored in the Empty Offset register. There are two possible default values
for n: 127 or 1,023. Other values for n can be programmed into the device.
HF
Half-Full Flag
O
HF indicates whether the FIFO memory is more or less than half-full.
Q
0
Q
8
Data Outputs
O
Data outputs for a 9-bus.
V
CC
Power
+3.3 Volt power supply pins.
GND
Ground
Ground pins.
5
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Symbol
Rating
Commercial
Unit
V
TERM
Terminal Voltage
0.5 to +4.6
V
with respect to GND
T
STG
Storage
55 to +125
C
Temperature
I
OUT
DC Output Current
50 to +50
mA
NOTES:
1. With output deselected, (
OE




V
IH
).
2. Characterized values, not currently tested.
DC ELECTRICAL CHARACTERISTICS
(Commercial: V
CC
= 3.3V 0.3V, T
A
= 0
o
C to +70
o
C; Industrial: V
CC =
3.3V
0.3V, TA= -40
C to +85
C)
Symbol
Parameter
(1)
Conditions
Max.
Unit
C
IN
(2)
Input
V
IN
= 0V
10
pF
Capacitance
C
OUT
(1,2)
Output
V
OUT
= 0V
10
pF
Capacitance
Symbol
Parameter
Min.
Typ.
Max.
Unit
V
CC
Supply Voltage(Com'l & Ind''l)
3.0
3.3
3.6
V
GND
Supply Voltage(Com'l & Ind'l)
0
0
0
V
V
IH
Input High Voltage
(Com'l & Ind'l)
2.0
--
V
CC
+ 0.5
V
V
IL
(1)
Input Low Voltage
(Com'l & Ind'l)
--
--
0.8
V
T
A
Operating Temperature
0
--
70
O
C
Commercial
T
A
Operating Temperature
-40
85
C
Industrial
IDT72V281L
IDT72V291L
Com'l & Ind'l
(1)
t
CLK
= 10, 15, 20 ns
Symbol
Parameter
Min.
Max.
Unit
I
LI
(2)
Input Leakage Current
1
1
A
I
LO
(3)
Output Leakage Current
10
10
A
V
OH
Output Logic "1" Voltage, I
OH
= 2 mA
2.4
--
V
V
OL
Output Logic "0" Voltage, I
OL
= 8 mA
--
0.4
V
I
CC1
(4,5,6)
Active Power Supply Current
--
55
mA
I
CC2
(4,7)
Standby Current
--
20
mA
NOTES
:
1.
Industrial temperature range product for the 15ns speed grade is available as a standard device.
2. Measurements with 0.4
V
IN
V
CC
.
3.
OE
V
IH,
0.4
V
OUT
V
CC.
4. Tested with outputs open (I
OUT
= 0).
5. RCLK and WCLK toggle at 20 MHz and data inputs switch at 10 MHz.
6. Typical I
CC1
= 11 + 1.65*f
S
+ 0.02*C
L
*f
S
(in mA) with V
CC
= 3.3V, t
A
= 25
o
C, f
S
= WCLK frequency = RCLK frequency (in MHz, using TTL levels), data switching at f
S
/2, C
L
= capacitive load (in pF).
7. All Inputs = V
CC
- 0.2V or GND + 0.2V, except RCLK and WCLK, which toggle at 20 MHz.
ABSOLUTE MAXIMUM RATINGS
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect reliability.
NOTE:
1. 1.5V undershoots are allowed for 10ns once per cycle.
RECOMMENDED DC OPERATING
CONDITIONS
CAPACITANCE
(T
A
= +25
o
C, f = 1.0MHz)
6
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
AC ELECTRICAL CHARACTERISTICS
(1)
(Commercial: V
CC
= 3.3V 0.3V, T
A
= 0
o
C to +70
o
C; Industrial: V
CC
= 3.3V
3.3V, TA = -40
C to +85
C)
Commercial
Com'l & Ind'l
(2)
Commercial
IDT72V281L10
IDT72V281L15
IDT72V281L20
IDT72V291L10
IDT72V291L15
IDT72V291L20
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Unit
f
S
Clock Cycle Frequency
--
100
--
66.7
--
50
MHz
t
A
Data Access Time
2
6.5
2
10
2
12
ns
t
CLK
Clock Cycle Time
10
--
15
--
20
--
ns
t
CLKH
Clock High Time
4.5
--
6
--
8
--
ns
t
CLKL
Clock Low Time
4.5
--
6
--
8
--
ns
t
DS
Data Setup Time
3
--
4
--
5
--
ns
t
DH
Data Hold Time
0.5
--
1
--
1
--
ns
t
ENS
Enable Setup Time
3
--
4
--
5
--
ns
t
ENH
Enable Hold Time
0.5
--
1
--
1
--
ns
t
LDS
Load Setup Time
3
--
4
--
5
--
ns
t
LDH
Load Hold Time
0.5
--
1
--
1
--
ns
t
RS
Reset Pulse Width
(3)
10
--
15
--
20
--
ns
t
RSS
Reset Setup Time
10
--
15
--
20
--
ns
t
RSR
Reset Recovery Time
10
--
15
--
20
--
ns
t
RSF
Reset to Flag and Output Time
--
10
--
15
--
20
ns
t
FWFT
Mode Select Time
0
--
0
--
0
--
ns
t
RTS
Retransmit Setup Time
3
--
4
--
5
--
ns
t
OLZ
Output Enable to Output in Low Z
(4)
0
--
0
--
0
--
ns
t
OE
Output Enable to Output Valid
2
6
3
8
3
10
ns
t
OHZ
Output Enable to Output in High Z
(4)
2
6
3
8
3
10
ns
t
WFF
Write Clock to
FF or IR
--
6.5
--
10
--
12
ns
t
REF
Read Clock to
EF or OR
--
6.5
--
10
--
12
ns
t
PAF
Write Clock to
PAF
--
6.5
--
10
--
12
ns
t
PAE
Read Clock to
PAE
--
6.5
--
10
--
12
ns
t
HF
Clock to
HF
--
16
--
20
--
22
ns
t
SKEW1
Skew time between RCLK and WCLK
5
--
6
--
10
--
ns
for
FF/IR
t
SKEW2
Skew time between RCLK and WCLK
12
--
15
--
20
--
ns
for
PAE and PAF
t
SKEW3
Skew time between RCLK and WCLK
60
--
60
--
60
--
ns
for
EF/OR
NOTES:
1. All AC timings apply to both Standard IDT mode and First Word Fall Through mode.
2. Industrial temperature range product for the 15ns speed grade is available as a standard device.
3. Pulse widths less than minimum values are not allowed.
4. Values guarenteed by design, not currently tested.
Input Pulse Levels
GND to 3.0V
Input Rise/Fall Times
3ns
Input Timing Reference Levels
1.5V
Output Reference Levels
1.5V
Output Load
See Figure 2
AC TEST CONDITIONS
Figure 2. Output Load
* Includes jig and scope capacitances.
4513 drw 04
330
30pF*
510
3.3V
D.U.T.
7
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
When configured in IDT Standard mode, the
EF and FF outputs are
double register-buffered outputs.
Relevant timing diagrams for IDT Standard mode can be found in Figure
7, 8 and 11.
FIRST WORD FALL THROUGH MODE (FWFT)
In this mode, the status flags,
IR, PAF, HF, PAE, and OR operate in
the manner outlined in Table 2. To write data into to the FIFO,
WEN must
be LOW. Data presented to the DATA IN lines will be clocked into the FIFO
on subsequent transitions of WCLK. After the first write is performed, the
Output Ready (
OR) flag will go LOW. Subsequent writes will continue to fill
up the FIFO.
PAE will go HIGH after n + 2 words have been loaded into the
FIFO, where n is the empty offset value. The default setting for this value
is stated in the footnote of Table 2. This parameter is also user program-
mable. See section on Programmable Flag Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the
HF would toggle to LOW once the
32,770th word for the IDT72V281 and 65,538th word for the IDT72V291,
respectively was written into the FIFO. Continuing to write data into the
FIFO will cause the
PAF to go LOW. Again, if no reads are performed, the
PAF will go LOW after (65,537-m) writes for the IDT72V281 and (131,073-m)
writes for the IDT72V291, where m is the full offset value. The default setting
for this value is stated in the footnote of Table 2.
When the FIFO is full, the Input Ready (
IR) flag will go HIGH, inhibiting
further write operations. If no reads are performed after a reset,
IR will go
HIGH after D writes to the FIFO. D = 65,537 writes for the IDT72V281 and
131,073 writes for the IDT72V291, respectively. Note that the additional
word in FWFT mode is due to the capacity of the memory plus output
register.
If the FIFO is full, the first read operation will cause the
IR flag to go LOW.
Subsequent read operations will cause the
PAF and HF to go HIGH at the
conditions described in Table 2. If further read operations occur, without
write operations, the
PAE will go LOW when there are n + 1 words in the
FIFO, where n is the empty offset value. Continuing read operations will
cause the FIFO to become empty. When the last word has been read from
the FIFO,
OR will go HIGH inhibiting further read operations. REN is
ignored when the FIFO is empty.
When configured in FWFT mode, the
OR flag output is triple register-
buffered, and the
IR flag output is double register-buffered.
Relevant timing diagrams for FWFT mode can be found in Figure 9, 10
and 12.
PROGRAMMING FLAG OFFSETS
Full and Empty Flag offset values are user programmable. The
IDT72V281/72V291 has internal registers for these offsets. Default settings
are stated in the footnotes of Table 1 and Table 2. Offset values can be
programmed into the FIFO in one of two ways; serial or parallel loading
method. The selection of the loading method is done using the
LD (Load)
pin. During Master Reset, the state of the
LD input determines whether
serial or parallel flag offset programming is enabled. A HIGH on
LD during
Master Reset selects serial loading of offset values and in addition, sets a
default
PAE offset value of 3FFH (a threshold 1,023 words from the empty
boundary), and a default
PAF offset value of 3FFH (a threshold 1,023
words from the full boundary). A LOW on
LD during Master Reset selects
parallel loading of offset values, and in addition, sets a default
PAE offset
value of 07FH (a threshold 127 words from the empty boundary), and a
default
PAF offset value of 07FH (a threshold 127 words from the full
boundary). See Figure 3, Offset Register Location and Default Values.
.UNCTIONAL DESCRIPTION
TIMING MODES: IDT STANDARD vs FIRST WORD FALL THROUGH
(FWFT) MODE
The IDT72V281/72V291 support two different timing modes of opera-
tion: IDT Standard mode or First Word Fall Through (FWFT) mode. The
selection of which mode will operate is determined during Master Reset,
by the state of the FWFT/SI input.
If, at the time of Master Reset, FWFT/SI is LOW, then IDT Standard
mode will be selected. This mode uses the Empty Flag (
EF) to indicate
whether or not there are any words present in the FIFO. It also uses the Full
Flag function (
FF) to indicate whether or not the FIFO has any free space
for writing. In IDT Standard mode, every word read from the FIFO, including
the first, must be requested using the Read Enable (
REN) and RCLK.
If, at the time of Master Reset, FWFT/SI is HIGH, then FWFT mode will
be selected. This mode uses Output Ready (
OR) to indicate whether or not
there is valid data at the data outputs (Q
n)
. It also uses Input Ready (
IR)
to indicate whether or not the FIFO has any free space for writing. In the
FWFT mode, the first word written to an empty FIFO goes directly to Q
n
after
three RCLK rising edges,
REN = LOW is not necessary. Subsequent
words must be accessed using the Read Enable (
REN) and RCLK.
Various signals, both input and output signals operate differently de-
pending on which timing mode is in effect.
IDT STANDARD MODE
In this mode, the status flags,
FF, PAF, HF, PAE, and EF operate in
the manner outlined in Table 1. To write data into to the FIFO, Write Enable
(
WEN) must be LOW. Data presented to the DATA IN lines will be clocked
into the FIFO on subsequent transitions of the Write Clock (WCLK). After the
first write is performed, the Empty Flag (
EF) will go HIGH. Subsequent
writes will continue to fill up the FIFO. The Programmable Almost-Empty
flag (
PAE) will go HIGH after n + 1 words have been loaded into the FIFO,
where n is the empty offset value. The default setting for this value is stated
in the footnote of Table 1. This parameter is also user programmable. See
section on Programmable Flag Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the Half-Full flag (
HF) would toggle to LOW
once the 32,769th word for IDT72V281 and 65,537th word for IDT72V291
respectively was written into the FIFO. Continuing to write data into the
FIFO will cause the Programmable Almost-Full flag (
PAF) to go LOW.
Again, if no reads are performed, the
PAF will go LOW after (65,536-m)
writes for the IDT72V281 and (131,072-m) writes for the IDT72V291. The
offset "m" is the full offset value. The default setting for this value is stated
in the footnote of Table 1. This parameter is also user programmable. See
section on Programmable Flag Offset Loading.
When the FIFO is full, the Full Flag (
FF) will go LOW, inhibiting further
write operations. If no reads are performed after a reset,
FF will go LOW
after D writes to the FIFO. D = 65,536 writes for the IDT72V281 and
131,072 for the IDT72V291, respectively.
If the FIFO is full, the first read operation will cause
FF to go HIGH.
Subsequent read operations will cause
PAF and HF to go HIGH at the
conditions described in Table 1. If further read operations occur, without
write operations,
PAE will go LOW when there are n words in the FIFO,
where n is the empty offset value. Continuing read operations will cause the
FIFO to become empty. When the last word has been read from the FIFO,
the
EF will go LOW inhibiting further read operations. REN is ignored when
the FIFO is empty.
8
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Number of
Words in
FIFO
0
1 to n
(1)
0
1 to n
(1)
(n+1) to 32,768
32,769 to (65,536-(m+1))
(65,536-m)
(2)
to 65,535
65,536
72V281
72V291
FF PAF HF PAE EF
H
H
H
L
L
H
H
H
L
H
H
H
H
H
H
H
H
L
H
H
H
L
L
H
H
L
L
L
H
H
4513 drw 05
0
1 to n+1
(1)
0
1 to n+1
(1)
(n+2) to 65,537
65,538 to (131,073-(m+1))
(131,073-m)
(2)
to 131,072
131,073
IR PAF HF PAE OR
L
H
H
L
H
L
H
H
L
L
L
H
H
H
L
L
H
L
H
L
L
L
L
H
L
H
L
L
H
L
72V281
72V291
Number of
Words in
FIFO
(n+1) to 65,536
65,537 to (131,072-(m+1))
(131,072-m)
(2)
to 131,071
131,072
(n+2) to 32,769
32,770 to (65,537-(m+1))
(65,537-m)
(2)
to 65,536
65,537
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
In addition to loading offset values into the FIFO, it also possible to read the
current offset values. It is only possible to read offset values via parallel read.
Figure 4, Programmable Flag Offset Programming Sequence, summa-
rizes the control pins and sequence for both serial and parallel programming
modes. For a more detailed description, see discussion that follows.
The offset registers may be programmed (and reprogrammed) any time
after Master Reset, regardless of whether serial or parallel programming
has been selected.
TABLE 1
STATUS .LAGS .OR IDT STANDARD MODE
TABLE 2
STATUS .LAGS .OR .W.T MODE
9
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 4. Programmable Flag Offset Programming Sequence
Figure 3. Offset Register Location and Default Values
NOTES:
1. The programming method can only be selected at Master Reset.
2. Parallel reading of the offset registers is always permitted regardless of which programming method has been selected.
3. The programming sequence applies to both IDT Standard and FWFT modes.
WCLK
RCLK
X
X
X
X
X
X
X
X
4513 drw 07
LD
0
0
X
1
1
1
0
WEN
0
1
1
0
X
1
1
REN
1
0
1
X
0
1
1
X
SEN
1
1
1
X
X
X
0
Parallel write to registers:
Empty Offset (LSB)
Full Offset (LSB)
Full Offset (MSB)
Parallel read from registers:
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
No Operation
Write Memory
Read Memory
No Operation
Empty Offset (MSB)
Serial shift into registers:
32 bits for the 72V281
Full Offset (LSB)
Parallel read from registers:
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
No Operation
Write Memory
Read Memory
No Operation
Serial shift into registers:
Empty Offset (Mid-Byte)
Full Offset (Mid-Byte)
1 bit for each rising WCLK edge
Starting with Empty Offset (LSB)
Ending with Full Offset (MSB)
Parallel write to registers:
Empty Offset (LSB)
Full Offset (MSB)
Full Offset (Mid-Byte)
Empty Offset (Mid-Byte)
Empty Offset (MSB)
34 bits for the 72V291
1 bit for each rising WCLK edge
Starting with Empty Offset (LSB)
Ending with Full Offset (MSB)
72V281
72V291
EMPTY OFFSET (LSB) REGISTER
8
7
0
72V281 (65,536 x 9>BIT)
FULL OFFSET (LSB) REGISTER
8
7
0
FULL OFFSET (MSB) REGISTER
8
7
0
DEFAULT VALUE
7FH if
LD
is LOW at Master Reset
FFH if
LD
is HIGH at Master Reset
DEFAULT VALUE
00H if
LD
is LOW at Master Reset
03H if
LD
is HIGH at Master Reset
DEFAULT VALUE
7FH if
LD
is LOW at Master Reset
FFH if
LD
is HIGH at Master Reset
EMPTY OFFSET (MSB) REGISTER
8
7
0
DEFAULT VALUE
00H if
LD
is LOW at Master Reset
03H if
LD
is HIGH at Master Reset
EMPTY OFFSET (LSB) REGISTER
8
7
0
72V291 (131,072 x 9>BIT)
FULL OFFSET (LSB) REGISTER
8
7
0
FULL OFFSET (MID-BYTE) REGISTER
8
7
0
DEFAULT VALUE
7FH if
LD
is LOW at Master Reset
FFH if
LD
is HIGH at Master Reset
DEFAULT VALUE
7FH if
LD
is LOW at Master Reset
FFH if
LD
is HIGH at Master Reset
DEFAULT VALUE
00H if
LD
is LOW at Master Reset
03H if
LD
is HIGH at Master Reset
EMPTY OFFSET (MID-BYTE) REGISTER
8
7
0
DEFAULT VALUE
00H if
LD
is LOW at Master Reset
03H if
LD
is HIGH at Master Reset
8
1
0
0H
8
0
1
DEFAULT
0H
DEFAULT
EMPTY OFFSET
(MSB) REGISTER
FULL OFFSET
(MSB) REGISTER
4513 drw 06
10
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
SERIAL PROGRAMMING MODE
If Serial Programming mode has been selected, as described above,
then programming of
PAE and PAF values can be achieved by using a
combination of the
LD, SEN, WCLK and SI input pins. Programming PAE
and
PAF proceeds as follows: when LD and SEN are set LOW, data on
the SI input are written, one bit for each WCLK rising edge, starting with the
Empty Offset LSB and ending with the Full Offset MSB. A total of 32 bits
for the IDT72V281 and 34 bits for the IDT72V291. See Figure 13, Serial
Loading of Programmable Flag Registers
, for the timing diagram for this
mode.
Using the serial method, individual registers cannot be programmed
selectively.
PAE and PAF can show a valid status only after the complete
set of bits (for all offset registers) has been entered. The registers can be
reprogrammed as long as the complete set of new offset bits is entered.
When
LD is LOW and SEN is HIGH, no serial write to the registers can
occur.
Write operations to the FIFO are allowed before and during the serial
programming sequence. In this case, the programming of all offset bits
does not have to occur at once. A select number of bits can be written to
the SI input and then, by bringing
LD and SEN HIGH, data can be written
to FIFO memory via D
n
by toggling
WEN. When WEN is brought HIGH
with
LD and SEN restored to a LOW, the next offset bit in sequence is
written to the registers via SI. If an interruption of serial programming is
desired, it is sufficient either to set
LD LOW and deactivate SEN or to set
SEN LOW and deactivate LD. Once LD and SEN are both restored to
a LOW level, serial offset programming continues.
From the time serial programming has begun, neither partial flag will be
valid until the full set of bits required to fill all the offset registers has been
written. Measuring from the rising WCLK edge that achieves the above
criteria;
PAF will be valid after two more rising WCLK edges plus t
PAF
,
PAE will be valid after the next two rising RCLK edges plus t
PAE
plus
t
SKEW2
.
It is not possible to read the flag offset values in a serial mode.
PARALLEL MODE
If Parallel Programming mode has been selected, as described above,
then programming of
PAE and PAF values can be achieved by using a
combination of the
LD, WCLK , WEN and D
n
input pins. For the
IDT72V281, programming
PAE and PAF proceeds as follows: when LD
and
WEN are set LOW, data on the inputs Dn are written into the Empty
Offset LSB Register on the first LOW-to-HIGH transition of WCLK. Upon the
second LOW-to-HIGH transition of WCLK, data are written into the Empty
Offset MSB Register. Upon the third LOW-to-HIGH transition of WCLK,
data are written into the Full Offset LSB Register. Upon the fourth LOW-
to-HIGH transition of WCLK, data are written into the Full Offset MSB
Register. The fifth transition of WCLK writes, once again, to the Empty
Offset LSB Register. See Figure 14, Parallel Loading of Programmable
Flag Registers for the IDT72V281
, for the timing diagram for this mode.
For the IDT72V291, programming
PAE and PAF proceeds as
follows: when
LD and WEN are set LOW, data on the inputs D
n
are written
into the Empty Offset LSB Register on the first LOW-to-HIGH transition of
WCLK. Upon the second LOW-to-HIGH transition of WCLK, data are
written into the Empty Offset Mid-Byte Register. Upon the third LOW-to-
HIGH transition of WCLK, data are written into the Empty Offset MSB
Register. Upon the fourth LOW-to-HIGH transition of WCLK, data are
written into the Full Offset LSB Register. Upon the fifth LOW-to-HIGH
transition of WCLK, data are written into the Full Offset Mid-Byte Register.
Upon the sixth LOW-to-HIGH transition of WCLK, data are written into the
Full Offset MSB Register. The seventh transition of WCLK writes, once
again, into the Empty Offset LSB Register. See Figure 15, Parallel Loading
of Programmable Flag Registers for the IDT72V291
, for the timing diagram
for this mode.
The act of writing offsets in parallel employs a dedicated write offset
register pointer. The act of reading offsets employs a dedicated read offset
register pointer. The two pointers operate independently; however, a read
and a write should not be performed simultaneously to the offset registers.
A Master Reset initializes both pointers to the Empty Offset (LSB) register.
A Partial Reset has no effect on the position of these pointers.
Write operations to the FIFO are allowed before and during the parallel
programming sequence. In this case, the programming of all offset registers
does not have to occur at one time. One, two or more offset registers can
be written and then by bringing
LD HIGH, write operations can be
redirected to the FIFO memory. When
LD is set LOW again, and WEN is
LOW, the next offset register in sequence is written to. As an alternative to
holding
WEN LOW and toggling LD, parallel programming can also be
interrupted by setting
LD LOW and toggling WEN.
Note that the status of a partial flag (
PAE or PAF) output is invalid
during the programming process. From the time parallel programming has
begun, a partial flag output will not be valid until the appropriate offset word
has been written to the register(s) pertaining to that flag. Measuring from the
rising WCLK edge that achieves the above criteria;
PAF will be valid after
two more rising WCLK edges plus t
PAF
,
PAE will be valid after the next two
rising RCLK edges plus t
PAE
plus t
SKEW2
.
The act of reading the offset registers employs a dedicated read offset
register pointer. The contents of the offset registers can be read on the Q
0
-
Q
n
pins when
LD is set LOW and REN is set LOW. For the IDT72V281,
data are read via Q
n
from the Empty Offset LSB Register on the first LOW-
to-HIGH transition of RCLK. Upon the second LOW-to-HIGH transition of
RCLK, data are read from the Empty Offset MSB Register. Upon the third
LOW-to-HIGH transition of RCLK, data are read from the Full Offset LSB
Register. Upon the fourth LOW-to-HIGH transition of RCLK, data are read
from the Full Offset MSB Register. The fifth transition of RCLK reads, once
again, from the Empty Offset LSB Register. See Figure 16, Parallel Read
of Programmable Flag Registers for the IDT72V281
, for the timing diagram
for this mode.
For the IDT72V291, data is read via Q
n
from the Empty Offset LSB
Register on the first LOW-to-HIGH transition of RCLK. Upon the second
LOW-to-HIGH transition of RCLK, data are read from the Empty Offset Mid-
Byte Register. Upon the third LOW-to-HIGH transition of RCLK, data are
read from the Empty Offset MSB Register. Upon the fourth LOW-to-HIGH
transition of RCLK, data are read from the Full Offset LSB Register. Upon
the fifth LOW-to-HIGH transition of RCLK, data are read from the Full Offset
Mid-Byte Register. Upon the sixth LOW-to-HIGH transition of RCLK, data
are read from the Full Offset MSB Register. The seventh transition of RCLK
reads, once again, from the Empty Offset LSB Register. See Figure 17,
Parallel Read of Programmable Flag Registers for the IDT72V291, for the
timing diagram for this mode.
It is permissible to interrupt the offset register read sequence with reads
or writes to the FIFO. The interruption is accomplished by deasserting
REN, LD, or both together. When REN and LD are restored to a LOW
level, reading of the offset registers continues where it left off. It should be
noted, and care should be taken from the fact that when a parallel read of
the flag offsets is performed, the data word that was present on the output
lines Qn will be overwritten.
11
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Parallel reading of the offset registers is always permitted regardless of
which timing mode (IDT Standard or FWFT modes) has been selected.
RETRANSMIT OPERATION
The Retransmit operation allows data that has already been read to be
accessed again. There are two stages: first, a setup procedure that resets
the read pointer to the first location of memory, then the actual retransmit,
which consists of reading out the memory contents, starting at the beginning
of memory.
Retransmit setup is initiated by holding
RT LOW during a rising RCLK
edge.
REN and WEN must be HIGH before bringing RT LOW. At least
one word, but no more than D - 2 words should have been written into the
FIFO between Reset (Master or Partial) and the time of Retransmit setup.
D = 65,536 for the IDT72V281 and D = 131,072 for the IDT72V291 in IDT
Standard mode. In FWFT mode, D = 65,537 for the IDT72V281 and
D = 131,073 for the IDT72V291.
If IDT Standard mode is selected, the FIFO will mark the beginning of
the Retransmit setup by setting
EF LOW. The change in level will only be
noticeable if
EF was HIGH before setup. During this period, the internal
read pointer is initialized to the first location of the RAM array.
When
EF goes HIGH, Retransmit setup is complete and read opera-
tions may begin starting with the first location in memory. Since IDT
Standard mode is selected, every word read including the first word
following Retransmit setup requires a LOW on
REN to enable the rising
edge of RCLK. See Figure 11, Retransmit Timing (IDT Standard Mode), for
the relevant timing diagram.
If FWFT mode is selected, the FIFO will mark the beginning of the
Retransmit setup by setting
OR HIGH. During this period, the internal read
pointer is set to the first location of the RAM array.
When
OR goes LOW, Retransmit setup is complete; at the same time,
the contents of the first location appear on the outputs. Since FWFT mode
is selected, the first word appears on the outputs, no LOW on
REN is
necessary. Reading all subsequent words requires a LOW on
REN to
enable the rising edge of RCLK. See Figure 12, Retransmit Timing (FWFT
Mode)
, for the relevant timing diagram.
For either IDT Standard mode or FWFT mode, updating of the
PAE,
HF and PAF flags begin with the rising edge of RCLK that RT is setup.
PAE is synchronized to RCLK, thus on the second rising edge of RCLK
after
RT is setup, the PAE flag will be updated. HF is asynchronous, thus
the rising edge of RCLK that
RT is setup will update HF. PAF is
synchronized to WCLK, thus the second rising edge of WCLK that occurs
t
SKEW
after the rising edge of RCLK that
RT is setup will update PAF. RT
is synchronized to RCLK.
12
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
SIGNAL DESCRIPTION
INPUTS:
DATA IN (D
0
- D
8
)
Data inputs for 9-bit wide data.
CONTROLS:
MASTER RESET (
MRS
MRS
MRS
MRS
MRS)
A Master Reset is accomplished whenever the
MRS input is taken to
a LOW state. This operation sets the internal read and write pointers to the
first location of the RAM array.
PAE will go LOW, PAF will go HIGH, and
HF will go HIGH.
If FWFT is LOW during Master Reset then the IDT Standard mode,
along with
EF and FF are selected. EF will go LOW and FF will go HIGH.
If FWFT is HIGH, then the First Word Fall Through mode (FWFT), along with
IR and OR, are selected. OR will go HIGH and IR will go LOW.
If
LD is LOW during Master Reset, then PAE is assigned a threshold
127 words from the empty boundary and
PAF is assigned a threshold 127
words from the full boundary; 127 words corresponds to an offset value of
07FH. Following Master Reset, parallel loading of the offsets is permitted,
but not serial loading.
If
LD is HIGH during Master Reset, then PAE is assigned a threshold
1,023 words from the empty boundary and
PAF is assigned a threshold
1,023 words from the full boundary; 1,023 words corresponds to an offset
value of 3FFH. Following Master Reset, serial loading of the offsets is
permitted, but not parallel loading.
Parallel reading of the registers is always permitted. (See section
describing the
LD pin for further details.)
During a Master Reset, the output register is initialized to all zeroes. A
Master Reset is required after power up, before a write operation can take
place.
MRS is asynchronous.
See Figure 5, Master Reset Timing, for the relevant timing diagram.
PARTIAL RESET (
PRS
PRS
PRS
PRS
PRS)
A Partial Reset is accomplished whenever the
PRS input is taken to a LOW
state. As in the case of the Master Reset, the internal read and write pointers are
set to the first location of the RAM array,
PAE goes LOW, PAF goes HIGH, and
HF goes HIGH.
Whichever mode is active at the time of Partial Reset, IDT Standard mode
or First Word Fall Through, that mode will remain selected. If the IDT Standard
mode is active, then
FF will go HIGH and EF will go LOW. If the First Word
Fall Through mode is active, then
OR will go HIGH, and IR will go LOW.
Following Partial Reset, all values held in the offset registers remain
unchanged. The programming method (parallel or serial) currently active
at the time of Partial Reset is also retained. The output register is initialized
to all zeroes.
PRS is asynchronous.
A Partial Reset is useful for resetting the device during the course of
operation, when reprogramming partial flag offset settings may not be
convenient.
See Figure 6, Partial Reset Timing, for the relevant timing diagram.
RETRANSMIT (
RT
RT
RT
RT
RT)
The Retransmit operation allows data that has already been read to be
accessed again. There are two stages: first, a setup procedure that resets the
read pointer to the first location of memory, then the actual retransmit, which
consists of reading out the memory contents, starting at the beginning of the
memory.
Retransmit setup is initiated by holding
RT LOW during a rising RCLK
edge.
REN and WEN must be HIGH before bringing RT LOW.
If IDT Standard mode is selected, the FIFO will mark the beginning of
the Retransmit setup by setting
EF LOW. The change in level will only be
noticeable if
EF was HIGH before setup. During this period, the internal
read pointer is initialized to the first location of the RAM array.
When
EF goes HIGH, Retransmit setup is complete and read opera-
tions may begin starting with the first location in memory. Since IDT
Standard mode is selected, every word read including the first word
following Retransmit setup requires a LOW on
REN to enable the rising
edge of RCLK. See Figure 11, Retransmit Timing (IDT Standard Mode), for
the relevant timing diagram.
If FWFT mode is selected, the FIFO will mark the beginning of the Retransmit
setup by setting
OR HIGH. During this period, the internal read pointer is set to
the first location of the RAM array.
When
OR goes LOW, Retransmit setup is complete; at the same time,
the contents of the first location appear on the outputs. Since FWFT mode
is selected, the first word appears on the outputs, no LOW on
REN is
necessary. Reading all subsequent words requires a LOW on
REN to
enable the rising edge of RCLK. See Figure 12, Retransmit Timing (FWFT
Mode)
, for the relevant timing diagram.
FIRST WORD FALL THROUGH/SERIAL IN (FWFT/SI)
This is a dual purpose pin. During Master Reset, the state of the FWFT/SI
input determines whether the device will operate in IDT Standard mode or First
Word Fall Through (FWFT) mode.
If, at the time of Master Reset, FWFT/SI is LOW, then IDT Standard
mode will be selected. This mode uses the Empty Flag (
EF) to indicate
whether or not there are any words present in the FIFO memory. It also uses
the Full Flag function (
FF) to indicate whether or not the FIFO memory has
any free space for writing. In IDT Standard mode, every word read from the
FIFO, including the first, must be requested using the Read Enable (
REN)
and RCLK.
If, at the time of Master Reset, FWFT/SI is HIGH, then FWFT mode will
be selected. This mode uses Output Ready (
OR) to indicate whether or not
there is valid data at the data outputs (Q
n)
. It also uses Input Ready (
IR)
to indicate whether or not the FIFO memory has any free space for writing.
In the FWFT mode, the first word written to an empty FIFO goes directly to
Q
n
after three RCLK rising edges,
REN = LOW is not necessary. Subse-
quent words must be accessed using the Read Enable (
REN) and RCLK.
After Master Reset, FWFT/SI acts as a serial input for loading
PAE and
PAF offsets into the programmable registers. The serial input function can
only be used when the serial loading method has been selected during
Master Reset. Serial programming using the FWFT/SI pin functions the
same way in both IDT Standard and FWFT modes.
WRITE CLOCK (WCLK)
A write cycle is initiated on the rising edge of the WCLK input. Data setup
and hold times must be met with respect to the LOW-to-HIGH transition of
the WCLK. It is permissible to stop the WCLK. Note that while WCLK is idle,
the
FF/IR, PAF and HF flags will not be updated. (Note that WCLK is only
capable of updating
HF flag to LOW.) The Write and Read Clocks can
either be independent or coincident.
WRITE ENABLE (
WEN
WEN
WEN
WEN
WEN)
When the
WEN input is LOW, data may be loaded into the FIFO RAM
array on the rising edge of every WCLK cycle if the device is not full. Data
is stored in the RAM array sequentially and independently of any ongoing
read operation.
13
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
When
WEN is HIGH, no new data is written in the RAM array on each
WCLK cycle.
To prevent data overflow in the IDT Standard mode,
FF will go LOW,
inhibiting further write operations. Upon the completion of a valid read cycle,
FF will go HIGH allowing a write to occur. The FF is updated by two WCLK
cycles + t
SKEW
after the RCLK cycle.
To prevent data overflow in the FWFT mode,
IR will go HIGH, inhibiting
further write operations. Upon the completion of a valid read cycle,
IR will
go LOW allowing a write to occur. The
IR flag is updated by two WCLK
cycles + t
SKEW
after the valid RCLK cycle.
WEN is ignored when the FIFO is full in either FWFT or IDT Standard
mode.
READ CLOCK (RCLK)
A read cycle is initiated on the rising edge of the RCLK input. Data can be
read on the outputs, on the rising edge of the RCLK input. It is permissible to
stop the RCLK. Note that while RCLK is idle, the
EF/OR, PAE and HF flags
will not be updated. (Note that RCLK is only capable of updating the
HF flag
to HIGH.) The Write and Read Clocks can be independent or coincident.
READ ENABLE (
REN
REN
REN
REN
REN)
When Read Enable is LOW, data is loaded from the RAM array into the
output register on the rising edge of every RCLK cycle if the device is not empty.
When the
REN input is HIGH, the output register holds the previous data
and no new data is loaded into the output register. The data outputs Q
0
-Q
n
maintain the previous data value.
In the IDT Standard mode, every word accessed at Q
n
, including the first
word written to an empty FIFO, must be requested using
REN. When the
last word has been read from the FIFO, the Empty Flag (
EF) will go LOW,
inhibiting further read operations.
REN is ignored when the FIFO is empty.
Once a write is performed,
EF will go HIGH allowing a read to occur. The
EF flag is updated by two RCLK cycles + t
SKEW
after the valid WCLK cycle.
In the FWFT mode, the first word written to an empty FIFO automatically
goes to the outputs Q
n
, on the third valid LOW to HIGH transition of RCLK+ t
SKEW
after the first write.
REN does not need to be asserted LOW. In order to access
all other words, a read must be executed using
REN. The RCLK LOW to HIGH
transition after the last word has been read from the FIFO, Output Ready (
OR)
will go HIGH with a true read (RCLK with
REN = LOW), inhibiting further read
operations.
REN is ignored when the FIFO is empty.
SERIAL ENABLE (
SEN
SEN
SEN
SEN
SEN)
The
SEN input is an enable used only for serial programming of the
offset registers. The serial programming method must be selected during
Master Reset.
SEN is always used in conjunction with LD. When these
lines are both LOW, data at the SI input can be loaded into the program
register one bit for each LOW-to-HIGH transition of WCLK. (See Figure 4.)
When
SEN is HIGH, the programmable registers retains the previous
settings and no offsets are loaded.
SEN functions the same way in both
IDT Standard and FWFT modes.
OUTPUT ENABLE (
OE
OE
OE
OE
OE)
When Output Enable is enabled (LOW), the parallel output buffers receive
data from the output register. When
OE is HIGH, the output data bus (Q
n
) goes
into a high impedance state.
LOAD (
LD
LD
LD
LD
LD)
This is a dual purpose pin. During Master Reset, the state of the
LD input
determines one of two default offset values (127 or 1,023) for the
PAE and
PAF flags, along with the method by which these offset registers can be
programmed, parallel or serial. After Master Reset,
LD enables write
operations to and read operations from the offset registers. Only the offset
loading method currently selected can be used to write to the registers.
Offset registers can be read only in parallel. A LOW on
LD during Master
Reset selects a default
PAE offset value of 07FH (a threshold 127 words
from the empty boundary), a default
PAF offset value of 07FH (a threshold
127 words from the full boundary), and parallel loading of other offset
values. A HIGH on
LD during Master Reset selects a default PAE offset
value of 3FFH (a threshold 1,023 words from the empty boundary), a default
PAF offset value of 3FFH (a threshold 1,023 words from the full boundary),
and serial loading of other offset values.
After Master Reset, the
LD pin is used to activate the programming
process of the flag offset values
PAE and PAF. Pulling LD LOW will begin
a serial loading or parallel load or read of these offset values. See Figure 4,
Programmable Flag Offset Programming Sequence.
OUTPUTS:
FULL FLAG (
FF
FF
FF
FF
FF/IR
IR
IR
IR
IR)
This is a dual purpose pin. In IDT Standard mode, the Full Flag (
FF)
function is selected. When the FIFO is full,
FF will go LOW, inhibiting further
write operations. When
FF is HIGH, the FIFO is not full. If no reads are
performed after a reset (either
MRS or PRS), FF will go LOW after D
writes to the FIFO (D = 65,536 for the IDT72V281 and 131,072 for the
IDT72V291). See Figure 7, Write Cycle and Full Flag Timing (IDT Standard
Mode)
, for the relevant timing information.
In FWFT mode, the Input Ready (
IR) function is selected. IR goes
LOW when memory space is available for writing in data. When there is no
longer any free space left,
IR goes HIGH, inhibiting further write operations.
If no reads are performed after a reset (either
MRS or PRS), IR will go
HIGH after D writes to the FIFO (D = 65,537 for the IDT72V281 and
131,073 for the IDT72V291) See Figure 9, Write Timing (FWFT Mode), for
the relevant timing information.
The
IR status not only measures the contents of the FIFO memory, but
also counts the presence of a word in the output register. Thus, in FWFT
mode, the total number of writes necessary to deassert
IR is one greater
than needed to assert
FF in IDT Standard mode.
FF/IR is synchronous and updated on the rising edge of WCLK. FF/IR
are double register-buffered outputs.
EMPTY FLAG (
EF
EF
EF
EF
EF/OR
OR
OR
OR
OR)
This is a dual purpose pin. In the IDT Standard mode, the Empty Flag
(
EF) function is selected. When the FIFO is empty, EF will go LOW,
inhibiting further read operations. When
EF is HIGH, the FIFO is not empty.
See Figure 8, Read Cycle, Empty Flag and First Word Latency Timing (IDT
Standard Mode)
, for the relevant timing information.
In FWFT mode, the Output Ready (
OR) function is selected. OR goes
LOW at the same time that the first word written to an empty FIFO appears
valid on the outputs.
OR stays LOW after the RCLK LOW to HIGH
transition that shifts the last word from the FIFO memory to the outputs.
OR
goes HIGH only with a true read (RCLK with
REN = LOW). The previous
data stays at the outputs, indicating the last word was read. Further data
reads are inhibited until
OR goes LOW again. See Figure 10, Read Timing
(FWFT Mode), for the relevant timing information.
EF/OR is synchronous and updated on the rising edge of RCLK.
In IDT Standard mode,
EF is a double register-buffered output. In FWFT
mode,
OR is a triple register-buffered output.
14
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
PROGRAMMABLE ALMOST-FULL FLAG (
PAF
PAF
PAF
PAF
PAF)
The Programmable Almost-Full flag (
PAF) will go LOW when the FIFO
reaches the almost-full condition. In IDT Standard mode, if no reads are
performed after reset (
MRS), PAF will go LOW after (D - m) words are
written to the FIFO. The
PAF will go LOW after (65,536-m) writes for the
IDT72V281 and (131,072-m) writes for the IDT72V291. The offset "m" is the
full offset value. The default setting for this value is stated in the footnote of
Table 1.
In FWFT mode, the
PAF will go LOW after (65,537-m) writes for the
IDT72V281 and (131,073-m) writes for the IDT72V291, where m is the full
offset value. The default setting for this value is stated in the footnote of
Table 2.
See Figure 18, Programmable Almost-Full Flag Timing (IDT Standard
and FWFT Mode), for the relevant timing information.
PAF is synchronous and updated on the rising edge of WCLK.
PROGRAMMABLE ALMOST-EMPTY FLAG (
PAE
PAE
PAE
PAE
PAE)
The Programmable Almost-Empty flag (
PAE) will go LOW when the
FIFO reaches the almost-empty condition. In IDT Standard mode, PAE will
go LOW when there are n words or less in the FIFO. The offset "n" is the
empty offset value. The default setting for this value is stated in the footnote
of Table 1.
In FWFT mode, the
PAE will go LOW when there are n+1 words or less in
the FIFO. The default setting for this value is stated in the footnote of Table 2.
See Figure 19, Programmable Almost-Empty Flag Timing (IDT Stan-
dard and FWFT Mode), for the relevant timing information.
PAE is synchronous and updated on the rising edge of RCLK.
HALF-FULL FLAG (
HF
HF
HF
HF
HF)
This output indicates a half-full FIFO. The rising WCLK edge that fills the
FIFO beyond half-full sets
HF LOW. The flag remains LOW until the
difference between the write and read pointers becomes less than or equal
to half of the total depth of the device; the rising RCLK edge that accom-
plishes this condition sets
HF HIGH.
In IDT Standard mode, if no reads are performed after reset (
MRS or
PRS), HF will go LOW after (D/2 + 1) writes to the FIFO, where D = 65,536
for the IDT72V281 and 131,072 for the IDT72V291.
In FWFT mode, if no reads are performed after reset (
MRS or PRS),
HF will go LOW after (D-1/2 + 2) writes to the FIFO, where D = 65,537 for
the IDT72V281 and 131,073 for the IDT72V291.
See Figure 20, Half-Full Flag Timing (IDT Standard and FWFT Modes),
for the relevant timing information. Because
HF is updated by both RCLK
and WCLK, it is considered asynchronous.
DATA OUTPUTS (Q
0
-Q
8
)
(Q
0
- Q
8
) are data outputs for 9-bit wide data.
15
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 5. Master Reset Timing
t
RS
MRS
t
RSR
REN
t
RSS
FWFT/SI
4513 drw 08
t
RSR
t
FWFT
t
RSR
WEN
t
RSS
LD
t
RSR
t
RSS
t
RSS
RT
SEN
t
RSS
t
RSF
t
RSF
OE
= HIGH
OE
= LOW
PAE
PAF
,
HF
Q
0
- Q
n
t
RSF
EF
/
OR
FF
/
IR
t
RSF
t
RSF
If FWFT = HIGH,
OR
= HIGH
If FWFT = LOW,
EF
= LOW
If FWFT = LOW,
FF
= HIGH
If FWFT = HIGH,
IR
= LOW
16
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 6. Partial Reset Timing
t
RS
PRS
t
RSR
REN
t
RSS
4513 drw 09
t
RSR
WEN
t
RSS
RT
SEN
t
RSS
t
RSF
t
RSF
OE
= HIGH
OE
= LOW
PAE
PAF
,
HF
Q
0
- Q
n
t
RSF
EF
/
OR
FF
/
IR
t
RSF
t
RSF
If FWFT = HIGH,
OR
= HIGH
If FWFT = LOW,
EF
= LOW
If FWFT = LOW,
FF
= HIGH
If FWFT = HIGH,
IR
= LOW
t
RSS
17
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 8. Read Cycle, Empty Flag and First Data Word Latency Timing (IDT Standard Mode)
NOTES:
1. t
SKEW3
is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that
EF will go HIGH (after one RCLK cycle plus t
REF
). If the time between the rising edge
of WCLK and the rising edge of RCLK is less than t
SKEW3
, then
EF deassertion may be delayed one extra RCLK cycle.
2.
LD = HIGH.
3. First data word latency: 60ns + t
REF
+ 1*T
RCLK
.
NOTES:
1. t
SKEW1
is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that
FF will go high (after one WCLK cycle pus t
WFF
). If the time between the rising
edge of the RCLK and the rising edge of the WCLK is less than t
SKEW1
, then the
FF deassertion may be delayed one extra WCLK cycle.
2.
LD = HIGH, OE = LOW, EF = HIGH
Figure 7. Write Cycle and Full Flag Timing (IDT Standard Mode)
D
0
- D
n
WEN
RCLK
REN
t
ENH
t
ENH
Q
0
- Q
n
DATA READ
NEXT DATA READ
DATA IN OUTPUT REGISTER
t
SKEW1
(1)
4513 drw 10
WCLK
NO WRITE
1
2
1
2
t
DS
NO WRITE
t
WFF
t
WFF
t
WFF
t
A
t
ENS
t
ENS
t
SKEW1
(1)
t
DS
t
A
D
X
t
DH
t
CLK
t
CLKH
t
CLKL
D
X
+1
t
WFF
t
DH
FF
NO OPERATION
RCLK
REN
4513 drw 11
EF
t
CLK
t
CLKH
t
CLKL
t
ENH
t
REF
t
A
t
OLZ
t
OE
Q
0
- Q
n
OE
WCLK
(1)
t
SKEW3
WEN
D
0
- D
n
t
ENS
t
ENS
t
ENH
t
DS
t
DHS
D
0
1
2
t
OLZ
NO OPERATION
LAST WORD
D
0
D
1
D
1
t
ENS
t
ENH
t
DS
t
DH
t
OHZ
LAST WORD
t
REF
t
ENH
t
ENS
t
A
t
A
t
REF
t
ENS
t
ENH
18
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 9. Write Timing (First Word Fall Through Mode
)
NOTES:
1. t
SKEW3
is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that
OR will go LOW after two RCLK cycles plus t
REF
. If the time between the rising edge of WCLK and the rising edge of RCLK is less than
t
SKEW3
, then
OR assertion may be delayed one extra RCLK cycle.
2. t
SKEW2
is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that
PAE will go HIGH after one RCLK cycle plus t
PAE
. If the time between the rising edge of WCLK and the rising edge of RCLK is less than
t
SKEW2
, then the
PAE deassertion may be delayed one extra RCLK cycle.
3.
LD = HIGH, OE = LOW
4. n =
PAE offset, m = PAF offset and D = maximum FIFO depth.
5. D = 65,537 for the IDT72V281 and 131,073 for the IDT72V291.
6. First data word latency: 60ns + t
REF
+ 2*T
RCLK
.
W
1
W
2
W
4
W
[n +2]
W
[D-m-1]
W
[D-m-2]
W
[D-1]
W
D
W
[n+3]
W
[n+4]
W
[D-m]
W
[D-m+1]
WCLK
WEN
D
0
- D
8
RCLK
t
DH
t
DS
t
ENS
t
SKEW3
(1)
REN
Q
0
- Q
8
PAF
HF
PAE
IR
t
DS
t
DS
t
DS
t
SKEW2
t
A
t
REF
OR
t
PAE
t
HF
t
PAF
t
WFF
W
[D-m+2]
W
1
t
ENH
4513 drw 12
DATA IN OUTPUT REGISTER
(2)
W
3
1
2
3
1
D-1
]
[
W
D-1
]
[
W
D-1
]
[
W
1
2
19
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 10. Read Timing (First Word Fall Through Mode
)
NOTES:
1. t
SKEW1
is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that
IR will go LOW after one WCLK cycle plus t
WFF
. If the time between the rising edge of RCLK and the rising edge of WCLK is less than
t
SKEW1
, then the
IR assertion may be delayed one extra WCLK cycle.
2. t
SKEW2
is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that
PAF will go HIGH after one WCLK cycle plus t
PAF
. If the time between the rising edge of RCLK and the rising edge of WCLK is less than
t
SKEW2
, then the
PAF deassertion may be delayed one extra WCLK cycle.
3.
LD = HIGH
4. n =
PAE Offset, m = PAF offset and D = maximum FIFO depth.
5. D = 65,537 for the IDT72V281 and 131,073 for the IDT72V291.
WCLK
1
2
WEN
D
0
- D
8
RCLK
t
ENS
REN
Q
0
- Q
8
PAF
HF
PAE
IR
OR
W
1
W
1
W
2
W
3
W
m+2
W
[m+3]
t
OHZ
t
SKEW1
t
ENH
t
DS
t
DH
t
OE
t
A
t
A
t
A
t
PAF
t
WFF
t
WFF
t
ENS
OE
t
SKEW2
W
D
4513 drw 13
t
PAE
W
[D-n]
W
[D-n-1]
t
A
t
A
t
HF
t
REF
W
[D-1]
W
D
t
A
W
[D-n+1]
W
[m+4]
W
[D-n+2]
(1)
(2)
t
ENS
D-1
]
[
W
D-1
]
[
W
1
20
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
NOTES:
1. Retransmit setup is complete after
EF returns HIGH, only then can a read operation begin.
2.
OE = LOW.
3. W
1
= first word written to the FIFO after Master Reset, W
2
= second word written to the FIFO after Master Reset.
4. No more than D - 2 may be written to the FIFO between Reset (Master or Partial) and Retransmit setup. Therefore,
FF will be HIGH throughout the Retransmit setup procedure. D = 65,536
for the IDT72V281 and 131,072 for the IDT72V291.
5.
EF goes HIGH at 60ns + 1 RCLK cycle + t
REF
.
Figure 11. Retransmit Timing (IDT Standard Mode)
t
REF
t
RTS
t
ENH
4513 drw 14
t
A
t
ENS
W
x
WCLK
RCLK
REN
RT
EF
PAF
HF
PAE
Q
0
- Q
n
t
SKEW2
1
2
1
W
1
t
PAF
t
HF
t
PAE
t
REF
W
x+1
2
W
2
t
ENH
WEN
t
ENS
t
RTS
t
ENS
t
ENH
(3)
t
A
t
A
(3)
(5)
21
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
NOTES:
1. Retransmit setup is complete after
OR returns LOW.
2. No more than D - 2 words may be written to the FIFO between Reset (Master or Partial) and Retransmit setup. Therefore,
IR will be LOW throughout the Retransmit setup procedure.
D = 65,537 for the IDT72V281 and 131,073 for the IDT72V291.
3.
OE = LOW
4. W
1
, W
2
, W
3
= first, second and third words written to the FIFO after Master Reset.
5.
OR goes LOW at 60ns + 2 RCLK cycles + t
REF
.
Figure 12. Retransmit Timing (FWFT Mode)
Figure 13. Serial Loading of Programmable Flag Registers (IDT Standard and FWFT Modes)
NOTE:
1. X = 15 for the IDT72V281 and X = 16 for the IDT72V291.
t
REF
t
RTS
t
ENH
4513 drw 15
t
ENS
W
x
WCLK
RCLK
REN
RT
OR
PAF
HF
PAE
Q
0
- Q
n
t
SKEW2
1
2
1
t
PAF
t
HF
t
PAE
t
REF
W
x+1
2
W
2
t
ENH
t
RTS
WEN
t
ENS
W
1
t
ENH
(4)
(5)
3
4
t
ENH
W
3
t
A
t
A
WCLK
SEN
SI
4513 drw 16
t
ENH
t
ENS
t
LDS
LD
t
DS
BIT 0
EMPTY OFFSET
BIT X
BIT 0
FULL OFFSET
(1)
t
ENH
BIT X
(1)
t
LDH
t
DH
t
LDH
22
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 15. Parallel Loading of Programmable Flag Registers (IDT Standard and FWFT Modes) for the IDT72V291
Figure 14. Parallel Loading of Programmable Flag Registers (IDT Standard and FWFT Modes) for the IDT72V281
Figure 16. Parallel Read of Programmable Flag Registers (IDT Standard and FWFT Modes) for the IDT72V281
NOTE:
1.
OE = LOW
Figure 17. Parallel Read of Programmable Flag Registers (IDT Standard and FWFT Modes) for the IDT72V291
NOTE:
1.
OE = LOW
LD
REN
t
LDH
t
LDH
t
LDS
t
ENS
t
ENH
t
ENH
4513 drw 20
RCLK
Q
0
- Q
7
DATA IN OUTPUT REGISTER
PAE OFFSET
(MSB)
PAF OFFSET
(MSB)
P A E O F F S E T
( M I D - B Y T E )
PAE OFFSET
(LSB)
PAF OFFSET
(MID-BYTE)
PAF OFFSET
(LSB)
t
CLKL
t
CLKH
t
CLK
t
A
t
A
RCLK
LD
REN
Q
0
- Q
7
t
LDH
t
LDS
t
ENS
DATA IN OUTPUT REGISTER
t
ENH
t
ENH
t
LDH
4513 drw 19
t
CLK
t
A
t
A
t
CLKH
t
CLKL
PAF OFFSET
(MSB)
PAF OFFSET
(LSB)
PAE OFFSET
(MSB)
PAE OFFSET
(LSB)
WCLK
LD
WEN
D
0
- D
7
t
LDS
t
ENS
PAE OFFSET
(LSB)
PAE OFFSET
(MID-BYTE)
t
DS
t
DH
t
ENH
PAE OFFSET
(MSB)
PAF OFFSET
(LSB)
4513 drw 18
PAF OFFSET
(MID-BYTE)
PAF OFFSET
(MSB)
t
LDH
t
CLK
t
DH
t
CLKH
t
CLKL
t
LDH
t
ENH
WCLK
LD
WEN
D
0
- D
7
t
LDS
t
ENS
PAE OFFSET
(LSB)
t
DS
t
DH
t
ENH
PAF OFFSET
(LSB)
PAF OFFSET
(MSB)
4513 drw 17
t
LDH
t
CLK
t
DH
t
CLKH
t
CLKL
t
LDH
t
ENH
PAE OFFSET
(MSB)
23
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
NOTES:
1. m =
PAF offset .
2. D = maximum FIFO depth.
In IDT Standard mode: D = 65,536 for the IDT72V281 and 131,072 for the IDT72V291.
In FWFT mode: D = 65,537 for the IDT72V281 and 131,073 for the IDT72V291.
3. t
SKEW2
is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that
PAF will go HIGH (after one WCLK cycle plus t
PAF
). If the time between the rising edge of
RCLK and the rising edge of WCLK is less than t
SKEW2
, then the
PAF deassertion time may be delayed one extra WCLK cycle.
4.
PAF is asserted and updated on the rising edge of WCLK only.
Figure 18. Programmable Almost-Full Flag Timing (IDT Standard and FWFT Modes)
NOTES:
1. n =
PAE offset.
2. For IDT Standard mode
3. For FWFT mode.
4. t
SKEW2
is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that
PAE will go HIGH (after one RCLK cycle plus t
PAE
). If the time between the rising edge of
WCLK and the rising edge of RCLK is less than t
SKEW2
, then the
PAE deassertion may be delayed one extra RCLK cycle.
5.
PAE is asserted and updated on the rising edge of WCLK only.
Figure 20. Half-Full Flag Timing (IDT Standard and FWFT Modes)
Figure 19. Programmable Almost-Empty Flag Timing (IDT Standard and FWFT Modes)
NOTES:
1. For IDT Standard mode: D = maximum FIFO depth. D = 65,536 for the IDT72V281 and 131,072 for the IDT72V291.
2. For FWFT mode: D = maximum FIFO depth. D = 65,537 for the IDT72V281 and 131,073 for the IDT72V291.
WCLK
t
ENS
t
ENH
WEN
HF
t
ENS
t
HF
RCLK
t
HF
REN
4513 drw 23
t
CLKL
t
CLKH
D/2 words in FIFO
(1)
,
[
+ 1
]
words in FIFO
(2)
D-1
2
D/2 + 1 words in FIFO
(1)
,
[
+ 2
]
words in FIFO
(2)
D-1
2
D/2 words in FIFO
(1)
,
[
+ 1
]
words in FIFO
(2)
D-1
2
WCLK
t
ENH
t
CLKH
t
CLKL
WEN
PAE
RCLK
t
ENS
n words in FIFO
(2)
,
n+1 words in FIFO
(3)
t
PAE
t
SKEW2
t
PAE
1
2
1
2
(4)
REN
4513 drw 22
t
ENS
t
ENH
n+1 words in FIFO
(2)
,
n+2 words in FIFO
(3)
n words in FIFO
(2)
,
n+1 words in FIFO
(3)
WCLK
t
ENH
t
CLKH
t
CLKL
WEN
PAF
RCLK
(3)
t
PAF
REN
4513 drw 21
t
ENS
t
ENH
t
ENS
D - (m+1) words in FIFO
(2)
t
PAF
D - m words in FIFO
(2)
t
SKEW2
1
2
1
2
D-(m+1) words
in FIFO
(2)
24
COCOMM
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
NOTES:
1. Use an AND gate in IDT Standard mode, an OR gate in FWFT mode.
2. Do not connect any output control signals directly together.
3. FIFO #1 and FIFO #2 must be the same depth, but may be different word widths.
OPTIONAL CON.IGURATIONS
WIDTH EXPANSION CONFIGURATION
Word width may be increased simply by connecting together the control
signals of multiple devices. Status flags can be detected from any one
device. The exceptions are the
EF and FF functions in IDT Standard mode
and the
IR and OR functions in FWFT mode. Because of variations in skew
between RCLK and WCLK, it is possible for
EF/FF deassertion and IR/
OR assertion to vary by one cycle between FIFOs. In IDT Standard mode,
Figure 21. Block Diagram of 65,536 x 18 and 131,072 x 18 Width Expansion
DEPTH EXPANSION CONFIGURATION (FWFT MODE ONLY)
The IDT72V281 can easily be adapted to applications requiring depths
greater than 65,536 and 131,072 for the IDT72V291 with a 9-bit bus width.
In FWFT mode, the FIFOs can be connected in series (the data outputs of
one FIFO connected to the data inputs of the next) with no external logic
necessary. The resulting configuration provides a total depth equivalent to
the sum of the depths associated with each single FIFO. Figure 22 shows
a depth expansion using two IDT72V281/72V291 devices.
Care should be taken to select FWFT mode during Master Reset for all
FIFOs in the depth expansion configuration. The first word written to an
empty configuration will pass from one FIFO to the next ("ripple down") until
it finally appears at the outputs of the last FIFO in the chainno read
operation is necessary but the RCLK of each FIFO must be free-running.
Each time the data word appears at the outputs of one FIFO, that device's
OR line goes LOW, enabling a write to the next FIFO in line.
For an empty expansion configuration, the amount of time it takes for
OR
of the last FIFO in the chain to go LOW (i.e. valid data to appear on the last
FIFO's outputs) after a word has been written to the first FIFO is the sum of the
delays for each individual FIFO:
(N 1)*(4*transfer clock) + 3*T
RCLK
where N is the number of FIFOs in the expansion and T
RCLK
is the RCLK period.
Note that extra cycles should be added for the possibility that the t
SKEW3
specification is not met between WCLK and transfer clock, or RCLK and transfer
clock, for the
OR flag.
The "ripple down" delay is only noticeable for the first word written to an
empty depth expansion configuration. There will be no delay evident for
subsequent words written to the configuration.
The first free location created by reading from a full depth expansion
configuration will "bubble up" from the last FIFO to the previous one until it
finally moves into the first FIFO of the chain. Each time a free location is
created in one FIFO of the chain, that FIFO's
IR line goes LOW, enabling
the preceding FIFO to write a word to fill it.
such problems can be avoided by creating composite flags, that is, ANDing
EF of every FIFO, and separately ANDing FF of every FIFO. In FWFT
mode, composite flags can be created by ORing
OR of every FIFO, and
separately ORing
IR of every FIFO.
Figure 21 demonstrates a width expansion using two IDT72V281/
72V291 devices. D
0
- D
8
from each device form a 18-bit wide input bus and
Q
0
-Q
8
from each device form a 18-bit wide output bus. Any word width can
be attained by adding additional IDT72V281/72V291 devices.
WRITE CLOCK (WCLK)
m + n
m
n
MASTER RESET (
MRS
)
READ CLOCK (RCLK)
DATA OUT
n
m + n
WRITE ENABLE (
WEN
)
FULL FLAG/INPUT READY (
FF
/
IR
)
PROGRAMMABLE (
PAF
)
PROGRAMMABLE (
PAE
)
EMPTY FLAG/OUTPUT READY (
EF
/
OR
) #2
OUTPUT ENABLE (
OE
)
READ ENABLE (
REN
)
m
LOAD (
LD
)
IDT
72V281
72V291
EMPTY FLAG/OUTPUT READY (
EF
/
OR
) #1
PARTIAL RESET (
PRS
)
IDT
72V281
72V291
4513 drw 24
FULL FLAG/INPUT READY (
FF
/
IR
) #2
HALF-FULL FLAG (
HF
)
FIRST WORD FALL THROUGH/
SERIAL INPUT (FWFT/SI)
RETRANSMIT (
RT
)
#1
FIFO
#2
GATE
(1)
GATE
(1)
D
0
- Dm
DATA IN
Dm
+1
- Dn
Q
0
- Qm
Qm
+1
- Qn
FIFO
#1
25
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGE
IDT72V281/72V291
Figure 22. Block Diagram of 131,072 x 9 and 262,144 x 9 Depth Expansion
For a full expansion configuration, the amount of time it takes for
IR of the first
FIFO in the chain to go LOW after a word has been read from the last FIFO is
the sum of the delays for each individual FIFO:
(N 1)*(3*transfer clock) + 2 T
WCLK
where N is the number of FIFOs in the expansion and T
WCLK
is the WCLK
period. Note that extra cycles should be added for the possibility that the
t
SKEW1
specification is not met between RCLK and transfer clock, or WCLK and
transfer clock, for the
IR flag.
The Transfer Clock line should be tied to either WCLK or RCLK,
whichever is faster. Both these actions result in data moving, as quickly as
possible, to the end of the chain and free locations to the beginning of the
chain.
Dn
INPUT READY
WRITE ENABLE
WRITE CLOCK
WEN
WCLK
IR
DATA IN
RCLK
READ CLOCK
RCLK
REN
OE
OUTPUT ENABLE
OUTPUT READY
Qn
Dn
IR
GND
WEN
WCLK
OR
REN
OE
Qn
READ ENABLE
OR
DATA OUT
IDT
72V281
72V291
TRANSFER CLOCK
4513 drw 25
n
n
n
FWFT/SI
FWFT/SI
FWFT/SI
IDT
72V281
72V291
26
2975 Stender Way
800-345-7015
Santa Clara, CA 95054
fax: 408-492-8674
www.idt.com
SuperSyncFIFO is a trademark and the IDT logo is a registered trademark of Integrated Device Technology, Inc.
ORDERING IN.ORMATION
NOTE:
1. Industrial temperature range product for the 15ns speed grade is available as a standard device.
Thin Plastic Quad Flatpack (TQFP, PN64-1)
Commercial (0 C to +70 C)
Low Power
65,536 x 9 3.3V SuperSyncFIFO
4513 drw 26
Clock Cycle Time (t
CLK
)
Speed in Nanoseconds
Commercial Only
PF
IDT
XXXXX
Device Type
X
Power
XX
Speed
X
Package
X
Process /
Temperature
Range
BLANK
72V281
I
(1)
Industrial (-40 C to +85 C)
TF
Slim Thin Quad Flatpack (STQFP, PP64-1)
10
15
20
Com'l & Ind'l
Commercial Only
L
72V291
131,072 x 9 3.3V SuperSyncFIFO
DATASHEET DOCUMENT HISTORY
04/24/2001
pgs. 1, 5, 6 and 26.