TECHNICAL DATA

Low Power Ground Fault Interrupter
IL4145A


ORDERING INFORMATION
IL4145AN Plastic DIP
IL4145AD SOIC
T
A
= -35
to 85 C for all packages.
The IL4145AN is a low power controller for AC outlet ground fault
interrupters. These devices detect hazardous grounding conditions, such as
equipment (connected to opposite phases of the AC line) in contact with a
pool of water and open circuits the line before a harmful or lethal shock
occurs.
Contained internally are a 26V zener shunt regulator, an op amp, and an
SCR driver. With the addition of two sense transformers, a bridge rectifier,
an SCR, a relay, and a few additional components, the IL4145AN will
detect and protect against both hot wire to ground and neutral wire to
ground faults. The simple layout and conventional design ensure ease of
application and long-term reliability.
No
potentiomenter required
Direct interface to SCR
Supply voltage derived from AC line - 26V shunt
Adjustable sensitivity
Grounded neutral fault detection
Meets U.L. 943 standards
450 A quiescent current
Ideal for 120 V or 220 V systems
BLOCK DIAGRAM
+
+
+
R1
+Input
V
FB
V
REF
+V
S
(+13V)
(+26V)
Op Amp Output
SCR Trigger
Ground
6.5 V
6.5 V
6.5 V
6.5 V
R2
R3
10K
10K
4.7K
PIN ASSIGNMENT
1
2
3
4
NC
8
7
6
5
GND
+V
S
V
REF
+Input
V
FB
Op Amp Output
SCR Trigger
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter
Value
Unit
I
CC
Supply Current
18
mA
P
D
Internal Power Dissipation
500
mW
Tstg
Storage Temperature Range
-65 to +150
C
Topr
Operating Temperature Range
-35 to +85
C
T
J
Junction Temperature
125
C
T
L
Lead Temperature
125
C
T
A
< 50C
450
mW
P
D
For T
A
> 50C Derate at
6
mW/C
IL4145A
ELECTRICAL CHARACTERISTICS
(I
S
= 1.5 mA and T
A
= +25C)
Symbol Parameter
Test Condition
Min
Max
Unit
V
OH
Detector Reference Voltage
Pin 7 to Pin 3
6.8
8.1
V
Shunt Regulator
+V
S
Zener Voltage
Pin 6 to Pin 4
25 29.2 V
V
REF
Reference Voltage
Pin 3 to Pin 4
12.5 14.6 V
I
S
Quiescent Current
+V
S
= 24 V
750 A
Operational Amplifier
V
IO
Offset Voltage
Pin 2 to Pin 3
-3.0
+3.0
mV
V
D
+Output Voltage Swing
Pin 7 to Pin 3
6.8
8.1
V
V
OL
-Output Voltage Swing
Pin 7 to Pin 3
-13.5
-9.5
V
I
OH
+Output Source Current
Pin 7 to Pin 3
-450 -850
A
I
OL
-Output Source Current
Pin 7 to Pin 3
800
1200
A
BW
Gain Bandwidth Product
F = 50 KHz
1.0
MHz
Resistors
I
S
= 0 mA
R1
R1
Pin 1 to Pin 3
8
12
k
R2
R2
Pin 2 to Pin 3
8
12
k
R3
R3
Pin 5 to Pin 4
3.5
5.9
k
SCR Trigger Voltage
Pin 5 to Pin 4
V
ON
Detector On
1.5
V
V
OFF
Detector Off
0 10 mV

ELECTRICAL CHARACTERISTICS
(I
S
= 1.5 mA and -35C T
A
+85C)
Symbol Parameter
Test Condition
Min
Max
Unit
V
OH
Detector Reference Voltage
Pin 7 to Pin 3
6.5
8.3
V
Shunt Regulator
+V
S
Zener Voltage
Pin 6 to Pin 4
24
30 V
V
REF
Reference Voltage
Pin 3 to Pin 4
12
15 V
I
S
Quiescent Current
+V
S
= 23 V
800 A
Operational Amplifier
V
IO
Offset Voltage
Pin 2 to Pin 3
-5.0
+5.0
mV
V
D
+Output Voltage Swing
Pin 7 to Pin 3
6.5
8.3
V
V
OL
-Output Voltage Swing
Pin 7 to Pin 3
-14
-9
V
Resistors
I
S
= 0 mA
R1
R1
Pin 1 to Pin 3
7.5
12.5
k
R2
R2
Pin 2 to Pin 3
7.5
12.5
k
R3
R3
Pin 5 to Pin 4
3.5
5.9
k
SCR Trigger Voltage
Pin 5 to Pin 4
V
ON
Detector On
1.3
V
V
OFF
Detector Off
0 50 mV
IL4145A

Principles of Operation

The 26V shunt regulator voltage generated by the string
of zener diodes is divided into three reference voltages:
3/4 VS , 1/2 VS , and 1/4 VS . VREF is at 1/2VS and is
used as a reference to create an artifical ground of +13V
at the op amp noninverting input.
Figure 1 shows a three-wire 120V AC outlet GFI
application using an IL4145AN. Fault signals from the
sense transformer are AC coupled into the input and are
amplified according to the following equation:

V7 = RSENSE x ISENSE/N
Where V7 is the RMS voltage at pin 7 relative to pin 3,
RSENSE is the value of the feedback resistor connected
from pin 7 to pin 1, ISENSE is the fault current in amps
RMS and N is the turns ratio of the transformer. When
V7 exceeds plus or minus 7.2V relative to pin 3 the SCR
Trigger output will go high and fire the external SCR.
The formula for V7 is approximate because it does not
include the sense transformer characteristics.


Grounded neutral fault detection is accomplished when a
short or fault closes a magnetic path between the sense
transformer and the grounded neutral transformer. The
resultant AC coupling closes a positive feedback path
around the op amp, and therefore the op amp oscillates.
When the peaks of the oscillation voltage exceed the
SCR trigger comparator thresholds, the SCR output will
go high.
Shunt Regulator
RLINE limits the current into the shunt regulator; 220V
applications will require substituting a 47k
2W
resistor. In addition to supplying power to the IC, the
s
h
u
n
t
regulator creates internal reference voltages (see above).
Operational Amplifier
RSENSE is a feedback resistor that sets gain and
therefore sensitivity to normal faults. To adjust
RSENSE, follow this procedure: apply the desired fault
current (a difference in current of 5mA is the UL 943
standard).


Adjust RSENSE upward until the SCR activates. A fixed
resistor can be used for RSENSE, since the resultant
15% variation in sensitivity will meet UL's 943 4-6mA
specification window.
The roll-off frequency is greater than the grounded
neutral fault oscillation frequency, in order to preserve
loop gain for oscillation (which is determined by the
inductance of the 200:1 transformer and C4).
The senstivity to grounded neutral faults is adjusted by
changing the frequency of oscillation. Increasing the
frequency reduces the sensitivity by reducing the loop
gain of the positive feedback circuit. As frequency
increases, the signal becomes attenuated and the loop
gain decreases. With the values shown the circuit will
detect a grounded neutral fault having resistance of 2

or less.
The input to the op amp are protected from overvoltage
by back-toback diodes.
SCR Driver
The SCR used must have a high dV/dt rating to ensure
that line noise (generated by noisy appliances such as a
drill motor) does not falsely trigger the SCR. Also, the
SCR must have a gate drive requirement of less than
200A. C
F
is a noise filter capacitor that prevents narrow
pulses from firing the SCR.
The relay solenoid used should have a 3ms or less
response time in order to meet the UL 943 timing
requirement.
Sense Transformers and Cores
The sense and grounded neutral transformer cores are
usually fabricated using high permeability laminated
steel rings. Their single turn primary is created by
passing the line and neutral wires through the center of
its core. The secondary is usually from 200 to 1500
turns.
Two-Wire Application Circuit
Figure 2 shows the diagram of a 2-wire 120V AC outlet
GFI circuit using an IL4145AN. This circuit is not
designed to detect grounded neutral faults. Thus, the
grounded neutral transformer and capacitors C3 and C4
of Figure 1 are not used.






IL4145A







1000:1
Hot
Line
C1
C3
C4
C2
C
F
Q1 ON Semi
MCR100-6
DB1
Solenoid
Load
Latching
Contacts
K1
1M*
IL4145AN
10 F
0.01 F
0.03 F
0.01 F
2.2 F
1N4004 (4)
15K
R
TEST
M
OV
R
SENSE
V
FB
+V
S
R
LINE
V
REF
(+13V)
Neutral
Press
To Test
200:1
Sense Transformer
Ground Neutral
Transformer
GND
24 K
Op Amp Output
SCR Trigger



* Value depends on transformer characteristics.

Figure 1. GFI Application Circuit (Three-Wire Outlet)










IL4145A



1000:1
Hot
Line
C1
C2
C
F
Q1 Tagi
X0103DA
DB1
Solenoid
Load
Latching
Contacts
K1
1M*
IL4145AN
10 F
0.01 F
2.2 F
1N4004 (4)
15K
R
TEST
M
OV
R
SENSE
V
FB
+V
S
R
LINE
V
REF
(+13V)
Neutral
Press
To Test
Sense Transformer
GND
24 K
Op Amp Output
SCR Trigger

* Value depends on transformer characteristics.

Figure 2. GFI Application Circuit (Two-Wire Outlet)