TECHNICAL DATA
IN24LC04B/08B
4K/8K 2.5V CMOS Serial EEPROMs


DESCRIPTION
IN24LC04B/08B is a 4K-or 8K-bit Electrically Erasable PROM. The device is organized as two or four blocks of 256 x
8 bit memory with a two wire serial interface. Low voltage design permits operation down to 2.5 volts with standby and
active currents of only 5
A and 1mA respectively. The IN24LC04B/08B also has a page-write capability for up to 16
bytes of data. The IN24LC04B/08B is available in the standard 8-pin DIP.
PACKAGE
T
A
= -40 ... +85
C
PINNING
Name Function
Vss Ground
SDA
Serial Address/Data I/O
SCL Serial
Clock
WP
Write Protect Input
VCC
+2.5V to 5.5V Power Supply
AO, A1, A2
No Internal Connection
FEATURES
Single supply with operation down to 2.5V
Low power CMOS technology
- 1 mA active current typical
- 10
A standby current typical at 5.5V
- 5
A standby current typical at 3.0V
Organized as two or four blocks of 256 bytes (2x256x8) and
(4x256x8)
Two wire serial interface bus, I
2
C compatible
Schmitt trigger, filtered inputs for noise suppression
Output slope control to eliminate ground bounce
100 kHz (2.5V) and 400 kHz (5V) compatibility
Self-timed write cycle (including auto-erase)
Page-write buffer for up to 16 bytes
2 ms typical write cycle time for page-write
Hardware write protect for entire memory
Can be operated as a serial ROM
Factory programming (QTP) available
ESD protection > 4,000V
1,000,000 ERASE/WRITE cycles guaranteed*
Data retention > 200 years
8-pin DIP
Temperature range -40 to +85
o
C

Pin Connection
1 8
2 7
3 6
4 5
A0
Vcc
A1
WP
A2
SCL
Vss
SDA
1
IN24LC04B/08B




Figure 1. Representative Block Diagram


ELECTRICAL CHARACTERISTICS
Maximum Ratings*
Parameter Value
V
CC
7.0 V
All inputs and outputs w.r.t.Vss
-0.3V to Vcc + 1.0V
Storage temperature
-65
o
C to +150
o
C
Ambient temp. with power applied
-40 to +85
o
C
Soldering temperature of leads (10 seconds)
+300
o
C
ESD protection on all pins
> 4 kV


DC CHARACTERISTICS
Vcc = +2.5V to +5.5V Commercial: Tamb = -40to +85
Parameter Symbol
Min
Max
Units
Mode
WP, SCL and SDA pins:
High level input voltage
Low level input voltage
Hysteresis of Schmitt trigger inputs
Low level output voltage
V
lH
V
IL
V
HYS
V
OL
0.7V
CC
-
0.05V
CC
-
-
0.3V
CC
-
0.40
V
V
V
V


Note 1
I
OL
= 3.0mA, V
CC
= 2.5V
Input leakage current
I
LI
-10 10
A
V
lN
=0.1V to V
CC
Output leakage current
I
LO
-10 10
A
V
OUT
=0.1V to V
CC
Pin capacitance (all inputs/outputs)
C
IN
C
OUT
- 10
pF
V
CC
= 5.0V (Note 1)
Tamb =25
o
C, Fclk =1MHz
Operating current
I
CC
WRITE
I
CC
READ
-
-
3
1
mA
mA
V
CC
= 5.5V SCL = 400kHz
Standby current
I
CCS
-
-
30
100
A
A
SDA=SCL=V
CC
=3.0V,
SDA=SCL=V
CC
=5.5V
2
IN24LC04B/08B



Figure 2. Bus timing Start/Stop

AC CHARACTERISTICS
STANDARD
MODE
Vcc = 4.5 - 5.5V
FAST MODE

Parameter
Symbol
Min
Max Min Max

Units

Remarks
Clock frequency
F
CLK
-
100 - 400
kHz
Clock high time
T
HIGH
4000
-
600
- ns
Clock low time
T
LOW
4700
- 1300 - ns
SDA and SCL rise time
T
R
-
1000 - 300
ns
Note
2
SDA and SCL fall time
T
F
-
300 - 300
ns
Note
2
START condition hold time
T
HD:STA
4000
-
600
-
ns
After this period the
first clock pulse is
generated
START condition setup time
T
SU:STA
4700
-
600
-
ns
Only relevant for
repeated START
condition
Data input hold time
T
HD:DAT
0 -
0
- ns
Data input setup time
T
SU:DAT
250 -
100
- ns
STOP condition setup time
T
SU:STO
4000
-
600
-
ns
Output valid from clock
T
AA
-
3500 - 900
ns
Note
1
Bus free time
T
BUF
4700
- 1300 - ns
Time the bus must be
free before a new
transmission can start
Output fall time from V
IH
min
to V
IL
max
T
OF
-
250
20+0.1C
B
250 ns
Note2,
C
B
100pF
Input filter spike suppres-sion
(SDA & SCL pins)
T
SP
-
50 - 50
ns
Note 3
Write cycle time
T
WR
-
10 - 10
ms
Byte or Page
mode
Note 1: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined
region (minimum 300 ns) of the falling edge of SCL to avoid unintended generation of START or
STOP conditions.
Note 2: Not 100% tested. C
B
= total capacitance of one bus line in pF.
Note 3: The combined T
SP
and V
HYS
specifications are due to new Schmitt trigger inputs which provide
improved noise and spike suppression. This eliminates the need for a Ti specification for standard
operation.

3
IN24LC04B/08B


Figure 3. Bus timing Data

FUNCTIONAL DESCRIPTION
The IN24LC04B/08B supports a bidirectional two wire bus and data transmission protocol. A
device that sends data onto the bus is defined as transmitter, and a device receiving data as receiver.
The bus has to be controlled by a master device which generates the serial clock (SCL), controls the
bus access, and generates the START and STOP conditions, while the IN24LC04B/08B works as
slave. Both, master and slave can operate as transmitter or receiver but the master device
determines which mode is activated.
BUS CHARACTERISTICS
The following bus protocol has been defined:
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in
the data line while the clock line is HIGH will be interpreted as a START or STOP condition.
Accordingly, the following bus conditions have been defined (see Figure 4).
Bus not Busy (A)
Both data and clock lines remain HIGH.
Start Data Transfer (B)
A HIGH to LOW transition of the SDA line while the clock (SCL) is HIGH determines a START
condition. All commands must be preceded by a START condition.
Stop Data Transfer (C)
A LOW to HIGH transition of the SDA line while the clock (SCL) is HIGH determines a STOP
condition. All operations must be ended with a STOP condition.
Data Valid (D)
The state of the data line represents valid data when, after a START condition, the data line is stable
for the duration of the HIGH period of the clock signal.
The data on the line must be changed during the LOW period of the clock signal. There is one clock
pulse per bit of data.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of the data bytes transferred between the START and STOP conditions is determined by the
master device and is theoretically unlimited, although only the last sixteen will be stored when
doing a write operation. When an overwrite does occur it will replace data in a first in first out
fashion.



4
IN24LC04B/08B


Acknowledge
Each receiving device, when addressed, is obliged to generate an acknowledge after the reception of
each byte. The master device must generate an extra clock pulse which is associated with this
acknowledge bit.

Note:
The IN24LC04B/08B does not generate any acknowledge bits if an internal programming cycle is in
progress

The device that acknowledges, has to pull down the SDA line during the acknowledge clock pulse
in such a way that the SDA line is stable LOW during the HIGH period of the acknowledge related
clock pulse. Of course, setup and hold times must be taken into account. A master must signal an
end of data to the slave by not generating an acknowledge bit on the last byte that has been clocked
out of the slave. In this case, the slave must leave the data line HIGH to enable the master to
generate the STOP condition.

Figure 4. Data Transfer Sequence on the serial bus


BUS CHARACTERISTICS
Device Addressing and Operation
A control byte is the first byte received following the start condition from the master device. The
control byte consists of a four bit control code, for the IN24LC04B/08B this is set as 1010 binary
for read and write operations. The next three bits of the control byte are the block select bits (B2,
B1, BO). B2 is a don't care for both the IN24LC04B and IN24LC08B; B1 is a don't care for the
IN24LC04B. They are used by the master device to select which of the two or four 256 word blocks
of memory are to be accessed. These bits are in effect the most significant bits of the word address.
The last bit of the control byte defines the operation to be performed. When set to one a read
operation is selected, when set to zero a write operation is selected. Following the start condition,
the IN24LC04B/08B monitors the SDA bus checking the device type identifier being transmitted,
upon a 1010 code the slave device outputs an acknowledge signal on the SDA line. Depending on
the state of the R/W bit, the IN24LC04B/ 08B will select a read or write operation.
Operation
Control Code
Block Select
R/W
Read 1010
Block
Address
1
Write 1010
Block
Address 0



5