MODELS
VDC O
UTPUT
1
SINGLE
5
12
15
28
DUAL
5
12
15
DESCRIPTION
The MHP270 SeriesTM DC/DC converters provide up to 65 watts of
output power over the full 55C to 125C temperature range.
MHP270 models operate from a MIL-STD-704 nominal 270 volt DC
power bus from 160 to 400 VDC continuous operation with surges
to 450 volts and provide isolated outputs at 5, 12, 15, and 28 VDC.
Parallel operation for all loading conditions is supported without any
requirement for external components.
MHP270 DC/DC converters are constant frequency, pulse width
modulated switching power supplies which use a quasi-square
wave, two-switch single-ended forward converter design. Tight load
regulation is achieved through a wide-bandwidth magnetic feedback
circuit.
Up to five single output MHP converters may be used in parallel to
power a single load by simply connecting the share pins of all units.
Units in this configuration have a 85% current sharing accuracy over
all loading conditions.
MHP Series of converters feature a flexible synchronization scheme
in which units may be synchronized to an external clock or to one
another by using sync in and sync out pins provided on each unit.
MHP converters have a nominal switching frequency of 600 kHz, but
may be synchronized at any frequency from 525 to 675 kHz.
MHP converters meet a wide variety of military/aerospace perform-
ance and environmental specifications. Their continuous operation
input voltage (160 to 400) meets the normal operating limits of MIL-
STD-704. The unit shuts down above approximately 425 volts, but
it is rated to withstand a surge of up to 450 volts for 50 msec. The
units are built as fully hermetic thick film hybrids in Interpoint's MIL-
STD-1772 certified facilities.
The MHP270 Series offer a complete list of standard features which
include:
Undervoltage lock-out shuts down when the input line voltage falls
below approximately 120 VDC to provide smooth initialization.
Continuous short circuit protection current limit set at approxi-
mately 125%.
Soft-start controlled start-up at turn-on, release from inhibit, and
recovery from load fault conditions.
Remote sense to provide automatic compensation for voltage
drops on output lines on single output models.
DC/DC C
ONVERTERS
270 V
OLT
I
NPUT
MHP270 SERIES
65 WATT
F
EATURES
55 to +125C operation
160 to 400 VDC input
Fully isolated
Magnetic feedback
Fixed frequency, 600 kHz typical
Topology
Two Switch, Single Ended Forward
450 V / 50 ms transient protection
Inhibit input side and output side
Sync in and out
Indefinite short circuit protection
Remote sense on single models
Up to 85% efficiency
Parallelable: up to 5 converters
Size (max.): 3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm)
See Figures 5 and 6 for dimensions.
Weight:
86 grams maximum
Screening: Standard or ES. See Table 1 for more information
TYPICAL CHARACTERISTICS
SYNC AND INHIBIT (INH1, INH2)
RECOMMENDED OPERATING CONDITIONS
ABSOLUTE MAXIMUM RATINGS
Input Voltage
160 to 400 VDC
Output Power
50 to 65 watts depending on model
Lead Soldering Temperature (10 sec)
300C
Storage Temperature Range (Case)
65C to +150C
2
MHP270 SERIES
65 WATT
DC/DC C
ONVERTERS
Output Voltage Temperature Coefficient
100 ppm/C typical
Isolation
100 megohm minimum at 500 V
Conversion Frequency
Free run mode 600 kHz typical
525 kHz. min., 675 kHz max
External sync range: 525 to 675 kHz
Inhibit Pin Voltage (unit enabled)
INH1 =12 V typ., INH2 = 5 V typ
Low Line Drop Out - Vout drops 50 mv
Input voltage 155 VDC max
Undervoltage Lockout
Input voltage 110 VDC min
Input Voltage Range
160 to 400 VDC continuous
450 VDC for 50 msec transient
Case Operating Temperature (Tc)
55 to +125C full power
Derating Output Power/Current
Linearly from 100% at 125C to 0% at 135C
Electrical Characteristics: 25C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
Sync In (525 to 675 kHz)
Duty cycle 40% min, 60% max
Logic low 0.8 V max
Logic high 4.5 V min
If not used, connect to input common
Referenced to input common
Sync Out - Referenced to input common
Inhibit (INH1, INH2) TTL Open Collector
Logic low (output disabled)
INH1 referenced to input common
Logic low 0.8 V max
INH2 referenced to output common
Logic low 0.5 V max
Logic high (output enabled)
Open collector
Notes
1. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
2. Indefinite short circuit protection not guaranteed above 125C case.
3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
SINGLE OUTPUT MODELS
MHP27005S
MHP27012S
MHP27015S
MHP27028S
PARAMETER
CONDITION
MIN TYP MAX
MIN
TYP MAX
MIN
TYP MAX
MIN
TYP MAX
UNITS
OUTPUT VOLTAGE
4.95
5.00
5.05
11.88 12.00 12.12
14.85 15.00 15.15
27.22 28.00 28.28
VDC
OUTPUT CURRENT
V
IN
= 160 TO 400 VDC
0
--
10
0
--
5
0
--
4.33
0
--
2.32
A
OUTPUT POWER
V
IN
= 160 TO 400 VDC
0
--
50
0
--
60
0
--
65
0
--
65
W
OUTPUT RIPPLE
VOLTAGE
10 kHz - 2 MHz
--
--
50
--
--
50
--
--
75
--
--
280
mV p-p
LINE REGULATION
V
IN
= 160 TO 400 VDC
--
--
50
--
--
120
--
--
150
--
--
280
mV
LOAD REGULATION
NO LOAD TO FULL
--
--
50
--
--
120
--
--
150
--
--
280
mV
INPUT VOLTAGE
CONTINUOUS
160
270
400
160
270
400
160
270
400
160
270
400
VDC
TRANSIENT
1
50 ms
--
--
450
--
--
450
--
--
450
--
--
450
V
INPUT CURRENT
NO LOAD
--
--
20
--
--
20
--
--
20
--
--
20
mA
INHIBITED - INH1
--
--
8
--
--
10
--
--
7
--
--
10
mA
INHIBITED - INH2
--
--
15
--
--
15
--
--
15
--
--
15
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
--
--
50
--
--
50
--
--
45
--
--
50
mA p-p
EFFICIENCY
77
--
--
81
--
--
82
--
--
80
--
--
%
LOAD FAULT
2
POWER DISSIPATION
SHORT CIRCUIT
--
--
19
--
--
19
--
--
9
--
--
23
W
V
OUT
--
--
1.5
--
--
1.5
--
--
1.0
--
--
1.0
VDC
STEP LOAD RESP.
50% 100% 50%
TRANSIENT
--
--
300
--
--
700
--
--
700
--
--
1800
mV pk
RECOVERY
3
--
--
300
--
--
500
--
--
300
--
--
1000
s
3
MHP270 SERIES
65 WATT
DC/DC C
ONVERTERS
Electrical Characteristics: 25C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
MHP27005D
MHP27012D
MHP27015D
PARAMETER
CONDITIONS
MIN TYP MAX
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
OUTPUT VOLTAGE
+V
OUT
4.95
5.00
5.05
11.88 12.00
12.12 14.85 15.00
15.15
VDC
V
OUT
4.95
5.00
5.05
11.88 12.00
12.12
14.85 15.00
15.15
OUTPUT CURRENT
1
V
IN
= 160 TO 400 VDC
0
5
8.0
0
2.5
4.0
0
2.16
3.46
mA
OUTPUT POWER
V
IN
= 160 TO 400 VDC
0
--
50
0
--
60
0
--
65
W
OUTPUT RIPPLE
10 kHz - 2 MHz
VOLTAGE
V
OUT
--
50
100
--
50
125
--
50
125
mV p-p
LINE REGULATION
V
IN
= 160 TO 400 VDC
V
OUT
--
--
100
--
--
120
--
--
150
mV
LOAD REGULATION
2, 3
NO LOAD TO FULL
V
OUT
--
--
100
--
--
120
--
--
150
mV
CROSS REGULATION
4
EFFECT ON V
OUT
--
--
1000
--
--
800
--
--
750
mV
INPUT VOLTAGE
CONTINUOUS
160
270
400
160
270
400
160
270
400
VDC
TRANSIENT
5
50 ms
0
--
450
0
--
450
0
--
450
V
INPUT CURRENT
NO LOAD
--
--
20
--
--
20
--
--
20
mA
FULL LOAD
--
--
2.5
--
--
2.80
--
--
3.00
A
INHIBITED - INH1
--
--
10
--
--
10
--
--
8
mA
INHIBITED - INH2
--
--
15
--
--
15
--
--
15
INPUT RIPPLE
CURRENT
10 kHz - 10 MHz
--
--
45
--
--
45
--
--
45
mA p-p
EFFICIENCY
BALANCED LOAD
74
--
--
81
--
--
82
--
--
%
LOAD FAULT
6
POWER DISSIPATION
SHORT CIRCUIT
--
--
8
--
--
7.5
--
--
19
W
V
OUT
--
--
2.0
--
--
1.0
--
--
1.5
V
STEP LOAD
50 %100% LOAD
7
RESPONSE V
OUT
TRANSIENT
--
--
300
--
--
900
--
--
900
mV pk
RECOVERY
--
--
500
--
--
500
--
--
500
s
Notes
1. Up to 80% of the total output power is available from either output.
2. Connect Share pin (12) to Output Common (8) when not in use.
3. Assumes balanced loads on the outputs.
4. Effect on the negative output under the following conditions:
+I
OUT
70% to 30% of total power; I
OUT
30% to 70% of total power
5. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
6. Indefinite short circuit protection not guaranteed above 125C case.
7. Second output at 50%
8. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
RL
1
2
3
4
5
6
REMOTE SENSE CONNECTION
12
11
10
9
8
7
+
270 V
+
Inhibit
Sync In
Positive Input
Input Common
INH2
INH1
Sync Out
Sync In
Share
N/C
Pos. Sense
Sense Return
Output Common
Positive Output
F
IGURE
1: S
ENSE
C
ONNECTIONS
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - SENSE
4
MHP270 SERIES
65 WATT
DC/DC C
ONVERTERS
RL
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
12
11
10
9
8
7
12
11
10
9
8
7
12
11
10
9
8
7
MHP270 #1
MHP270 #2
MHP270 #N
270V
+
Positive Input
Input Common
INH2
INH1
Sync Out
Sync In
Share
N/C
Pos. Sense
Sense Return
Output Common
Positive Output
Positive Input
Input Common
INH2
INH1
Sync Out
Sync In
Share
N/C
Pos. Sense
Sense Return
Output Common
Positive Output
Positive Input
Input Common
INH2
INH1
Sync Out
Sync In
Share
N/C
Pos. Sense
Sense Return
Output Common
Positive Output
+
F
IGURE
2: P
ARALLEL
C
ONNECTIONS
PIN OUT
Pin
Single Output
Dual Output
1
Positive Input
Positive Input
2
Input Common
Input Common
3
Inhibit 2 (INH2)
Inhibit 2 (INH2)
4
Inhibit 1 (INH1)
Inhibit 1 (INH1)
5
Sync Out
Sync Out
6
Sync In
Sync In
7
Positive Output
Positive Output
8
Output Common
Output Common
9
Sense Return
Negative Output
10
Positive Sense
No connection
11
No connection
No connection
12
Share
Share
MODEL NUMBERING KEY
MHP 270 05 S / ES
Base Model
Input Voltage
Output Voltage
Screening
Number of Outputs
(S = single, D = dual)
(Standard screening has no designator
in this position.)
Pin 6 should be connected to input common if external
sync (Sync In) is not used.
Sense pins must be connected to their respective outputs
if not used.
Share operation not characterized for dual outputs.
Angled corner indicates pin one.
1
2
3
4
5
6
12
11
10
9
8
7
TOP VIEW
MHP
(Pin side, marked side)
See Figures 5 and 6 for dimensions.
F
IGURE
3: P
IN
O
UT
SINGLE OUTPUT MODELS CONNECTION DIAGRAM - PARALLEL
5
MHP270 SERIES
65 WATT
DC/DC C
ONVERTERS
Materials
Header Cold Rolled Steel/Nickel/Gold
Cover Kovar/Nickel
Pins
#52 alloy/Gold
compression glass seal
CASE U
TOP VIEW
(PIN SIDE)
See Figure 5 for dimensions
1.505 max (38.23)
3.005 (76.33) max.
Angled corner indicates pin one
F
IGURE
5: C
ASE
U M
AXIMUM
D
IMENSIONS
CAUTION
Heat from reflow or wave soldering may damage the
device. Solder pins individually with heat application not
exceeding 300C for 10 seconds per pin.
Case dimensions in inches (mm)
Tolerance 0.005 (0.13) for three decimal places, 0.01
(0.2) for two decimal places unless otherwise specified
Although every effort has been made to render the case
drawings at actual size, variations in the printing process
may cause some distortion. Please refer to the numerical
dimensions for accuracy.
Angled corner
indicates pin one.
1
2
3
4
5
6
12
11
10
9
8
7
0.000
0.050 (1.27)
0.000
0.120 (3.05)
0.250 (6.35)
0.450 (11.43)
0.650 (16.51)
0.850 (21.59)
1.050 (26.67)
1.250 (31.75)
1.380 (35.05)
1.505 (38.23) max.
0.000
0.120 (3.05)
0.250 (6.35)
2.750 (69.85)
2.880 (73.15)
3.005 (76.33) max.
0.128 dia
(3.25).
0.040 dia
(1.02)
0.23 (5.8) Lead Length
0.400 (10.16)
max.
0.220 (5.59
Seam Seal
TOP VIEW CASE U
F
IGURE
6: C
ASE
U