IS24C52
ISSI
Copyright 2004 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no liability
arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on any published
information and before placing orders for products.
2k-bit 2-WIRE SERIAL CMOS EEPROM
with Permanent Write-Protection
FEATURES
Two-Wire Serial Interface
Bidirectional data transfer protocol
400 kHz (I
2
C
TM
Protocol) Compatibility
Organization:
256-bit x 8-bit
Data Protection Features
Write Protect Pin
Permanent Software Protection
16-Byte Page Write Buffer
Partial Page-writes permitted
Low Power CMOS Technology
Active Current less than 2 mA (5V)
Standby Current less than 6 A (5V)
Standby Current less than 2 A (2.5V)
Low Voltage Operation
IS24C52-2: Vcc = 1.8V to 5.5V
IS24C52-3: Vcc = 2.5V to 5.5V
ADVANCED INFORMATION
JANUARY 2004
Random or Sequential Read Modes
Filtered Inputs for Noise Suppression
Self timed Write cycle with auto clear
5 ms @ 2.5V
High Reliability
Endurance: 1,000,000 Cycles
Data Retention: 40 Years
Commercial and Industrial temperature ranges
8-pin SOIC, 8-pin TSSOP, and 8-pin MSOP
DESCRIPTION
The IS24C52 is an electrically erasable PROM device
that uses the standard 2-wire interface for
communications. The IS24C52 contains a memory array
of 2,048-bits (256K x 8), and is further subdivided into 16
pages of 16 bytes each for page-write mode. The
software write-protection feature is initiated with a unique
irreversible instruction. After this command is
transmitted, the first 128 bytes of the array become
permanently read-only. This feature is popular in
applications like DRAM DIMMs to retain DRAM related
data. This EEPROM is offered in wide operating voltages
of
1.8V to 5.5V
(IS24C52-2) and 2.5V to 5.5V (IS24C52-
3) to be compatible with most application voltages. ISSI
designed the IS24C52 as a low-cost and low-power 2-
wire EEPROM solution. The devices are packaged in 8-
pin SOIC, and 8-pin TSSOP, and 8-pin MSOP.
The IS24C52 maintains compatibility with the popular 2-
wire bus protocol, so it is easy to use in applications
implementing this bus type. The simple bus consists of
the Serial Clock wire (SCL) and the Serial Data wire
(SDA). Using the bus, a Master device such as a
microcontroller is usually connected to one or more
Slave devices such as the IS24C52. The bit stream over
the SDA line includes a series of bytes, which identifies
a particular Slave device, an instruction, an address
within that Slave device, and a series of data, if
appropriate. The IS24C52 has a Write Protect pin (WP)
to allow blocking of any write instruction transmitted over
the bus.
2
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
PRELIMINARY INFORMATION
Rev. 00B
01/26/04
IS24C52
ISSI
FUNCTIONAL BLOCK DIAGRAM
>
CONTROL
LOGIC
X
DECODER
SLAVE ADDRESS
REGISTER &
COMPARATOR
WORD ADDRESS
COUNTER
HIGH VOLTAGE
GENERATOR,
TIMING & CONTROL
Y
DECODER
DATA
REGISTER
Clock
DI/O
ACK
GND
WP
SCL
SDA
Vcc
nMOS
A0
A1
A2
ARRAY
80H-FFH
00H-7FH
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
3
PRELIMINARY INFORMATION
Rev. 00B
01/26/04
IS24C52
ISSI
PIN DESCRIPTIONS
A0-A2
Address Inputs
SDA
Serial Address/Data I/O
SCL
Serial Clock Input
WP
Write Protect Input
Vcc
Power Supply
GND
Ground
SCL
This input clock pin is used to synchronize the data
transfer to and from the device.
SDA
The SDA is a Bi-directional pin used to transfer addresses
and data into and out of the device. The SDA pin is an open
drain output and can be wire Or'ed with other open drain or
open collector outputs. The SDA bus
requires a pullup
resistor to Vcc.
PIN CONFIGURATION
8-Pin SOIC, TSSOP, MSOP
WP
WP is the Write Protect pin. If the WP pin is tied to Vcc, the
entire array becomes Write Protected, and software write-
protection cannot be initiated. When WP is tied to GND or
left floating, normal read/write operations are allowed to the
device. If the device has already received a write-protection
command, the memory in the range of 00h-7Fh is read -only
regardless of the setting of the WP pin.
1
2
3
4
8
7
6
5
A0
A1
A2
GND
VCC
WP
SCL
SDA
A0, A1, A2
The A0, A1, and A2 are the device address inputs that are
hardwired or left unconnected for hardware flexibility. When
pins are hardwired, as many as eight devices may be
addressed on a single bus system. When the pins are not
hardwired, the default A0, A1, and A2 are zero.
DEVICE OPERATION
The IS24C52 features a serial communication and supports
a bi-directional 2-wire bus transmission protocol.
2-WIRE BUS
The two-wire bus is defined as a Serial Data line (SDA), and
a Serial Clock line (SCL). The protocol defines any device
that sends data onto the SDA bus as a transmitter, and the
receiving devices as a receiver. The bus is controlled by
Master device which generates the SCL, controls the bus
access and generates the Stop and Start conditions. The
IS24C52 is the Slave device on the bus.
4
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
PRELIMINARY INFORMATION
Rev. 00B
01/26/04
IS24C52
ISSI
The Bus Protocol:
Data transfer may be initiated only when the bus is not
busy
During a data transfer, the data line must remain stable
whenever the clock line is high. Any changes in the
data line while the clock line is high will be interpreted
as a Start or Stop condition.
The state of the data line represents valid data after a Start
condition. The data line must be stable for the duration of
the High period of the clock signal. The data on the SDA
line may be changed during the Low period of the clock
signal. There is one clock pulse per bit of data. Each data
transfer is initiated with a Start condition and terminated
with a Stop condition.
Start Condition
The Start condition precedes all commands to the device
and is defined as a High to Low transition of SDA when
SCL is High. The IS24C52 monitors the SDA and SCL lines
and will not respond until the Start condition is met.
Stop Condition
The Stop condition is defined as a Low to High transition of
SDA when SCL is High. All operations must end with a Stop
condition.
Acknowledge (ACK)
After a successful data transfer, each receiving device is
required to generate an ACK. The Acknowledging device
pulls down the SDA line.
Reset
The IS24C52 contains a reset function in case the 2-wire
bus transmission is accidentally interrupted (eg. a power
loss), or needs to be terminated mid-stream. The reset
is caused when the Master device creates a Start
condition. To do this, it may be necessary for the Master
device to monitor the SDA line while cycling the SCL up
to nine times. (For each clock signal transition to High,
the Master checks for a High level on SDA.)
Standby Mode
Power consumption in reduced in standby mode. The
IS24C52 will enter standby mode: a) At Power-up, and
remain in it until SCL or SDA toggles; b) Following the Stop
signal if no write operation is initiated; or c) Following any
internal write operation
DEVICE ADDRESSING
The Master begins a transmission by sending a Start
condition. The Master then sends the address of the
particular Slave devices it is requesting. The Slave
(Fig. 5) address is 8 bits.
The four most significant bits of the device address are fixed
as 1010 for normal read/write operations, and 0110 for
permanent write-protection operations.
This device has three address bits (A1, A2, and A0) that
allow up to eight IS24C52 devices to share the 2-wire
bus. Upon receiving the Slave address, the device
compares the three address bits with the hardwired A2,
A1, and A0 input pins to determine if it is the appropriate
Slave. If any of the A2 - A0 pins is neither biased to High
nor Low, then internal circuitry defaults the value to Low.
The last bit of the Slave address specifies whether a Read
or Write operation is to be performed. When this bit is set
to 1, a Read operation is selected, and when set to 0, a
Write operation is selected.
After the Master transmits the Start condition and
Slave address byte (Fig. 5), the appropriate 2-wire
Slave (eg. IS24C52) will respond with ACK on the SDA
line. The Slave will pull down the SDA on the ninth clock
cycle, signaling that it received the eight bits of data. The
selected IS24C52 then prepares for a Read or Write
operation by monitoring the bus.
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
5
PRELIMINARY INFORMATION
Rev. 00B
01/26/04
IS24C52
ISSI
WRITE OPERATION
Byte Write
In the Byte Write mode, the Master device sends the Start
condition and the Slave address information (with the R/
W
set to Zero) to the Slave device. After the Slave generates
an ACK, the Master sends a byte address that is written into
the address pointer of the IS24C52. After receiving another
ACK from the Slave, the Master device transmits the data
byte to be written into the address memory location. The
IS24C52 acknowledges once more and the Master generates
the Stop condition, at which time the device begins its
internal programming cycle. While this internal cycle is in
progress, the device will not respond to any request from the
Master device.
Page Write
The IS24C52 is capable of 16-byte Page-Write operation. A
Page-Write is initiated in the same manner as a Byte Write,
but instead of terminating the internal Write cycle after the
first data byte is transferred, the Master device can transmit
up to 15 more bytes. After the receipt of each data byte, the
IS24C52 responds immediately with an ACK on SDA line,
and the four lower order data byte address bits are internally
incremented by one, while the higher order bits of the data
byte address remain constant. If a byte address is
incremented from the last byte of a page, it returns to the first
byte of that page. If the Master device should transmit more
than 16 bytes prior to issuing the Stop condition, the address
counter will "roll over," and the previously written data will be
overwritten. Once all 16 bytes are received and the Stop
condition has been sent by the Master, the internal
programming cycle begins. At this point, all received data is
written to the IS24C52 in a single Write cycle. All inputs are
disabled until completion of the internal Write cycle.
Acknowledge (ACK) Polling
The disabling of the inputs can be used to take advantage of
the typical Write cycle time. Once the Stop condition is
issued to indicate the end of the host's Write operation, the
IS24C52 initiates the internal Write cycle. ACK polling can be
initiated immediately. This involves issuing the Start condition
followed by the Slave address for a Write operation. If the
IS24C52 is still busy with the Write operation, no ACK will be
returned. If the IS24C52 has completed the Write operation,
an ACK will be returned and the host can then proceed with
the next Read or Write operation.
Permanent Write Protection
The IS24C52 contains a permanent write protection feature
that is initiated by means of a software command. After the
command is transmitted, the protected area becomes
irreversibly read-only despite power removal and re-
application on the device. The address range of the 128
bytes of the array that is affected by this feature is 00h-7Fh.
Once enabled, the permanent protection is independent of
the status of the WP pin. (If WP is raised to High, the entire
array is read-only. If WP is low, the region 00h-7Fh can still
be read-only.)
The software command is initiated similarly to a normal
byte write operation; however, the slave address begins
with the bits 0110 (see Figure 5). The following three bits are
A2 - A0. The last bit of the slave address (R/
W)
is 0. If the
IS24C52 responds with ACK, then the device has not yet
had its write-protection permanently enabled. To complete
the command, the Master must transmit a dummy address
byte, dummy data byte, and a Stop signal
(see Figure 11). The WP pin must be Low during this
command. Before resuming any other command, the
internal write cycle should be observed.
The status of the permanent write protection can be safely
determined without any changes by transmitting the same
Slave address as above, but with the last bit (R/
W)
set to
1(see Figure 12). If the permanent write protection has been
enabled, then the IS24C52 will not acknowledge any slave
address starting with bits 0110 (see Figure 5).