ADVANCED INFORMATION
Rev. 00B
03/21/06
ISSI
Copyright 2006 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no liability
arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on any
published information and before placing orders for products.
IS24L128
IS24L256
128K-bit/ 256K-bit
2-WIRE SERIAL CMOS EEPROM
ADVANCED INFORMATION
APRIL 2006
DESCRIPTION
The IS24L128 and IS24L256 are electrically erasable
PROM devices that use the standard 2-wire interface
for communications. The IS24L128 and IS24CL256
contain a memory array of 128K-bits (16K x 8) and
256K-bits (32 x 8), respectively. Each device is
organized into 64 byte pages for page write mode.
This EEPROM operates in a voltage range of 1.8V to
3.6V for low voltage and standard voltage application
levels. ISSI designed this device family to be a
practical, low-power 2-wire EEPROM solution. The
devices are available in 8-pin PDIP, 8-pin (JEDEC)
SOIC, and 8-pin (EIAJ) SOIC packages.
The IS24L128/256 maintains compatibility with the
popular 2-wire bus protocol, so it is easy to design into
applications implementing this bus type. The simple
bus consists of the Serial Clock wire (SCL) and the
Serial Data wire (SDA). Using the bus, a Master device
such as a microcontroller is usually connected to one
or more Slave devices such as the IS24L128/256. The
bit stream over the SDA line includes a series of bytes,
which identifies a particular Slave device, an
instruction, an address within that Slave device, and a
series of data, if appropriate. The IS24L128/256 has a
Write Protect pin (WP) to allow blocking of any write
instruction transmitted over the bus.
FEATURES
Two-Wire Serial Interface, I
2
C
TM
compatible
Bi-directional data transfer protocol
Low Voltage and Standard Voltage Operation
Vcc = 1.8V to 3.6V
400 KHz (1.8V) and 1 MHz (2.5V, 2.7V, 3.6V)
compatibility
Low Power CMOS Technology
Active Current less than 3 mA (3.6V)
Stanby Current less than 3 A (3.6V)
Standby Current less than 1 A (1.8V)
Hardware Data Protection
Write Protect Pin
Sequential Read Feature
Filtered Inputs for Noise Suppression
Self time write cycle with auto clear
5 ms max @ 1.8V
Organization:
IS24L12816Kx8 (256 pages of 64 bytes)
IS24L25632Kx8 (512 pages of 64 bytes)
64 Byte Page Write Buffer
High Reliability
Endurance: 1,000,000 Cycles
Data Retention: 40 Years
Industrial temperature range
8-pin PDIP, 8-pin (JEDEC) SOIC, and 8-pin
(EIAJ) SOIC packages
Lead-free available
2
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
ADVANCED INFORMATION
Rev. 00B
03/21/06
ISSI
IS24L128
IS24L256
FUNCTIONAL BLOCK DIAGRAM
>
CONTROL
LOGIC
X
DECODER
SLAVE ADDRESS
REGISTER &
COMPARATOR
WORD ADDRESS
COUNTER
HIGH VOLTAGE
GENERATOR,
TIMING & CONTROL
EEPROM
ARRAY
Y
DECODER
DATA
REGISTER
Clock
DI/O
ACK
GND
WP
SCL
SDA
Vcc
nMOS
A0
A1
A2
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
3
ADVANCED INFORMATION
Rev. 00B
03/21/06
ISSI
IS24L128
IS24L256
PIN CONFIGURATION
8-Pin DIP and SOIC
SCL
This input clock pin is used to synchronize the data transfer
to and from the device.
SDA
The SDA is a Bi-directional pin used to transfer addresses
and data into and out of the device. The SDA pin is an open
drain output and can be wire Or'ed with other open drain or
open collector outputs. The SDA bus
requires a pullup
resistor to Vcc.
1
2
3
4
8
7
6
5
A0
A1
A2
GND
VCC
WP
SCL
SDA
PIN DESCRIPTIONS
A0-A2
Address Inputs
SDA
Serial Address/Data I/O
SCL
Serial Clock Input
WP
Write Protect Input
Vcc
Power Supply
NC
No Connect
GND
Ground
A0, A1, A2
The A0, A1, and A2 are the device address inputs that are
hardwired or left not connected for hardware compatibility
with the IS24C32/64. When pins are hardwired, as many as
eight IS24L128/256 devices may be addressed on a single
bus system. When the pins are not hardwired, the default
values of A0, A1, and A2 are zero.
WP
WP is the Write Protect pin. If the WP pin is tied to Vcc
the entire array becomes Write Protected (Read only).
When WP is tied to GND or left floating, normal read/write
operations are allowed to the device.
4
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
ADVANCED INFORMATION
Rev. 00B
03/21/06
ISSI
IS24L128
IS24L256
DEVICE OPERATION
The IS24L128/256 features a serial communication and
supports a bi-directional 2-wire bus transmission protocol
called I
2
C
TM
.
2-WIRE BUS
The two-wire bus is defined as a Serial Data line (SDA), and
a Serial Clock line (SCL). The protocol defines any device
that sends data onto the SDA bus as a transmitter, and the
receiving devices as receivers. The bus is controlled by
Master device which generates the SCL, controls the bus
access and generates the Stop and Start conditions. The
IS24L128/256 is the Slave device on the bus.
The Bus Protocol:
Data transfer may be initiated only when the bus is not
busy
During a data transfer, the SDA line must remain stable
whenever the SCL line is high. Any changes in the data
line while the SCL line is high will be interpreted as a
Start or Stop condition.
The state of the SDA line represents valid data after a Start
condition. The SDA line must be stable for the duration of
the High period of the clock signal. The data on the SDA
line may be changed during the Low period of the clock
signal. There is one clock pulse per bit of data. Each data
transfer is initiated with a Start condition and terminated
with a Stop condition.
Start Condition
The Start condition precedes all commands to the device
and is defined as a High to Low transition of SDA when
SCL is High. The EEPROM monitors the SDA and SCL
lines and will not respond until the Start condition is met.
Stop Condition
The Stop condition is defined as a Low to High transition of
SDA when SCL is High. All operations must end with a Stop
condition.
Acknowledge (ACK)
After a successful data transfer, each receiving device is
required to generate an ACK. The Acknowledging device
pulls down the SDA line.
Reset
The IS24L128/256 contains a reset function in case the
2-wire bus transmission is accidentally interrupted (eg. a
power loss), or needs to be terminated mid-stream. The
reset is caused when the Master device creates a Start
condition. To do this, it may be necessary for the Master
device to monitor the SDA line while cycling the SCL up
to nine times. (For each clock signal transition to High,
the Master checks for a High level on SDA.)
Standby Mode
Power consumption is reduced in standby mode. The
IS24L128/256 will enter standby mode: a) At Power-up, and
remain in it until SCL or SDA toggles; b) Following the Stop
signal if no write operation is initiated; or c) Following any
internal write operation
DEVICE ADDRESSING
The Master begins a transmission by sending a Start
condition. The Master then sends the address of the
particular Slave devices it is requesting. The Slave device
(Fig. 5) address is 8 bits.
The four most significant bits of the Slave device address
are fixed as 1010 for the IS24L128/256.
This device has three address bits (A2, A1, and A0),
which allows up to eight IS24L128/256 devices to share
the 2-wire bus. Upon receiving the Slave address, the
device compares the three address bits with the
hardwired A2, A1, and A0 input pins to determine if it is
the appropriate Slave.
The last bit of the Slave address specifies whether a Read
or Write operation is to be performed. When this bit is set
to 1, a Read operation is selected, and when set to 0, a
Write operation is selected.
After the Master transmits the Start condition and Slave
address byte (Fig. 5), the appropriate 2-wire Slave (eg.
IS24L128/256) will respond with ACK on the SDA line.
The Slave will pull down the SDA on the ninth clock
cycle, signaling that it received the eight bits of data.
The selected EEPROM then prepares for a Read or Write
operation by monitoring the bus.
WRITE OPERATION
Byte Write
In the Byte Write mode, the Master device sends the Start
condition and the Slave address information (with the R/
W
set to Zero) to the Slave device. After the Slave generates
an ACK, the Master sends the two byte address that are to
be written into the address pointer of the IS24L128/256. After
receiving another ACK from the Slave, the Master device
transmits the data byte to be written into the address
memory location. The IS24L128/256 acknowledges once
more and the Master generates the Stop condition, at which
time the device begins its internal programming cycle. While
this internal cycle is in progress, the device will not respond
to any request from the Master device.
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
5
ADVANCED INFORMATION
Rev. 00B
03/21/06
ISSI
IS24L128
IS24L256
Page Write
The IS24L128/256 is capable of 64-byte Page-Write operation.
A Page-Write is initiated in the same manner as a Byte Write,
but instead of terminating the internal Write cycle after the
first data word is transferred, the Master device can transmit
up to 63 more bytes. After the receipt of each data word, the
EEPROM responds immediately with an ACK on SDA line,
and the six lower order data word address bits are internally
incremented by one, while the higher order bits of the data
word address remain constant. If a byte address is
incremented from the last byte of a page, it returns to the
first byte of that page. If the Master device should transmit
more than 64 words prior to issuing the Stop condition, the
address counter will "roll over," and the previously written data
will be overwritten. Once all 64 bytes are received and the
Stop condition has been sent by the Master, the internal
programming cycle begins. At this point, all received data is
written to the IS24L128/256 in a single Write cycle. All inputs
are disabled until completion of the internal Write cycle.
should generate a Stop condition so the IS24L128/256
discontinues transmission. If 'n' is the last byte of the
memory, the data from location '0' will be transmitted. (Refer
to Figure 8. Current Address Read Diagram.)
Random Address Read
Selective Read operations allow the Master device to select
at random any memory location for a Read operation. The
Master device first performs a 'dummy' Write operation by
sending the Start condition, Slave address and word address
of the location it wishes to read. After the IS24L128/256
acknowledges the word address, the Master device resends
the Start condition and the Slave address, this time with the
R/
W bit set to one. The EEPROM then responds with its
ACK and sends the data requested. The Master device
does not send an ACK but will generate a Stop
condition. (Refer to Figure 9. Random Address Read
Diagram.)
Sequential Read
Sequential Reads can be initiated as either a Current
Address Read or Random Address Read. After the
IS24L128/256 sends the initial byte sequence, the Master
device now responds with an ACK indicating it requires
additional data from the IS24L128/256. The EEPROM
continues to output data for each ACK received. The
Master device terminates the sequential Read operation by
pulling SDA High (no ACK) indicating the last data word to
be read, followed by a Stop condition.
The data output is sequential, with the data from address n
followed by the data from address n+1, ... etc. The address
counter increments by one automatically, allowing the
entire memory contents to be serially read during sequential
Read operation. When the memory address boundary 16383
for IS24L128, or 32767 for IS24L256 is reached, the address
counter "rolls over" to address 0, and the device continues
to output data for each ACK received. (Refer to Figure 10.
Sequential Read Diagram.)
Acknowledge (ACK) Polling
The disabling of the inputs can be used to take advantage
of the typical Write cycle time. Once the Stop condition
is issued to indicate the end of the host's Write operation,
the IS24L128/256 initiates the internal Write cycle. ACK
polling can be initiated immediately. This involves issuing
the Start condition followed by the Slave address for a
Write operation. If the EEPROM is still busy with the Write
operation, no ACK will be returned. If the IS24L128/256 has
completed the Write operation, an ACK will be returned and
the host can then proceed with the next Read or Write
operation.
READ OPERATION
Read operations are initiated in the same manner as Write
operations, except that the (R/
W) bit of the Slave address
is set to "1". There are three Read operation options:
current address read, random address read, and sequential
read.
Current Address Read
The IS24L128/256 contains an internal address counter
which maintains the address of the last byte accessed,
incremented by one. For example, if the previous operation
is either a Read or Write operation addressed to the
address location n, the internal address counter would
increment to address location n+1. When the EEPROM
receives the Slave Device Addressing Byte with a Read
operation (R/
W bit set to "1"), it will respond an ACK and
transmit the 8-bit data word stored at address location
n+1. The Master should not acknowledge the transfer but