ChipFind - документация

Электронный компонент: DSEC29-02AS

Скачать:  PDF   ZIP
2004 IXYS All rights reserved
1 - 2
432
DSEC 29-02A
DSEC 29-02AS
IXYS reserves the right to change limits, test conditions and dimensions.
I
FAV
= 2x15 A
V
RRM
= 200 V
t
rr
= 25 ns
Symbol
Conditions
Maximum Ratings
I
FRMS
35
A
I
FAVM
T
C
= 150C; rectangular, d = 0.5
15
A
I
FSM
T
VJ
= 45C; t
p
= 10 ms (50 Hz), sine
140
A
E
AS
T
VJ
= 25C; non-repetitive
0.8
mJ
I
AS
= 2.5 A; L = 180 H
I
AR
V
A
= 1.5V
R
typ.; f = 10 kHz; repetitive
0.3
A
T
VJ
-55...+175
C
T
VJM
175
C
T
stg
-55...+150
C
P
tot
T
C
= 25C
95
W
M
d
mounting torque
0.45...0.55
Nm
4...5
lb.in.
Weight
typical
2 / 4
g
Symbol
Conditions
Characteristic Values
typ.
max.
I
R
T
VJ
= 25C; V
R
= V
RRM
100
A
T
VJ
= 150C; V
R
= V
RRM
0.5
mA
V
F
I
F
= 15 A;
T
VJ
= 150C
0.86
V
T
VJ
= 25C
1.06
V
R
thJC
1.6
K/W
R
thCH
0.5
K/W
t
rr
I
F
= 1 A; -di/dt = 100 A/s;
25
ns
V
R
= 30 V; T
VJ
= 25C
I
RM
V
R
= 100 V; I
F
= 25 A; -di
F
/dt = 100 A/s
3.5
4.4
A
T
VJ
= 100C
V
RSM
V
RRM
Type
V
V
200
200
DSEC 29-02A
200
200
DSEC 29-02AS
Features
International standard package
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low I
RM
-values
Soft recovery behaviour
Epoxy meets UL 94V-0
Applications
Antiparallel diode for high frequency
switching devices
Antisaturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Advantages
Avalanche voltage rated for reliable
operation
Soft reverse recovery for low
EMI/RFI
Low I
RM
reduces:
- Power dissipation within the diode
- Turn-on loss in the commutating switch
Dimensions see Outlines.pdf
Pulse test:
Pulse Width = 5 ms, Duty Cycle < 2.0 %
Pulse Width = 300
s, Duty Cycle < 2.0 %
Data according to IEC 60747 and per diode unless otherwise specified.
HiPerFRED
TM
Epitaxial Diode
with common cathode and soft recovery
A = Anode, C = Cathode, TAB = Cathode
C
A
TO-220 AC
C (TAB)
A
A
TO-263
A
C (TAB)
2004 IXYS All rights reserved
2 - 2
432
DSEC 29-02A
DSEC 29-02AS
IXYS reserves the right to change limits, test conditions and dimensions.
200
600
1000
0
400
800
30
40
50
60
70
80
0.00001
0.0001
0.001
0.01
0.1
1
0.001
0.01
0.1
1
10
0
40
80
120
160
0.6
0.8
1.0
1.2
1.4
K
f
T
VJ
C
-di
F
/dt
t
s
K/W
0
200
400
600
800
1000
0
10
20
30
40
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
V
FR
di
F
/dt
V
200
600
1000
0
400
800
0
5
10
15
20
25
30
100
1000
0
100
200
300
400
500
600
700
0.0
0.4
0.8
1.2
1.6
0
10
20
30
40
50
I
RM
Q
r
I
F
A
V
F
-di
F
/dt
-di
F
/dt
A/
s
A
V
nC
A/
s
A/
s
t
rr
ns
A/
s
DSEC 29-02A
Z
thJC
T
VJ
= 150C
T
VJ
= 100C
T
VJ
= 25C
V
FR
t
fr
I
RM
Q
r
I
F
= 30 A
I
F
= 15 A
I
F
= 7.5 A
I
F
= 30 A
I
F
= 15 A
I
F
= 7.5 A
T
VJ
= 100C
I
F
= 15 A
t
fr
s
I
F
= 30 A
I
F
= 15 A
I
F
= 7.5 A
T
VJ
= 100C
V
R
= 100 V
T
VJ
= 100C
V
R
= 100 V
T
VJ
= 100C
V
R
= 100 V
Fig. 3 Typ. peak reverse current I
RM
Fig. 2 Typ. reverse recovery charge Q
r
Fig. 1 Forward current I
F
versus V
F
Fig. 4 Typ. dynamic parameters Q
r
, I
RM
Fig. 5 Typ. recovery time t
rr
versus -di
F
/dt
Fig. 6 Typ. peak forward voltage
V
FR
and t
fr
Fig. 7 Transient thermal resistance junction to case
Constants for Z
thJC
calculation:
i
R
thi
(K/W)
t
i
(s)
1
0.851
0.0052
2
0.328
0.0003
4
0.421
0.0409