ChipFind - документация

Электронный компонент: MYB-1206-33

Скачать:  PDF   ZIP
159
Noise
Filter
Features
(1) High attenuation effect against high voltage
pulse noise by amorphous core.
(2) Block terminal with cover
Simple wire connection
High safety by cover.
Safety standard
UL1283, CSA Std. C22. 2 No. 8
VDE0565 Teil. 3, Teil 3A2
VDE0565 will transfer to EN133200
on and after July 23, 2003.
Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
Contact us about delivery before ordering.
MYB
-SERIES
Circuit
Derating
Specifications
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Rated voltage (AC, DC)
Rated current (AC, DC)
(Note)
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
Leakage current
DC resistance
Temperature rise
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Vibration
Safety standard
Weight (typ)
250V
2500V (25C, 70% RH)
100M
min. (25C, 70% RH)
0.25mA max.
0.5mA max.
30C max.
25 ~ +85C
30% ~ 90% RH (No dewdrop)
30 ~ +85C
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours
Approved by UL1283, CSA C22.2 No. 8 (C-UL) and VDE0565 Teil3, Teil3A2
0.1
max.
0.05
max.
0.02
max.
0.01
max.
Item
Model
MYB-1206-33
MYB-1210-33
MYB-1220-33
MYB-1230-33
6A
10A
20A
30A
210g
260g
450g
510g
125V, 60Hz
250V, 60Hz
(Note) : Value at Ta 50C. Refer to the derating curve shown below at Ta > 50C.
MYB-1220-33
MYB-1230-33
MYB-1210-33
MYB-1206-33
<
=
(
)
160
Noise
Filter
MYB
-SERIES
MYB-1206-33
MYB-1210-33
MYB-1220-33
MYB-1230-33
Models
MXB-1206-33
MXB-1210-33
A
108
118
B
75
85
C
90
100
D
26
30
Case: Metal
(Unit: mm)
161
Noise
Filter
MYB
-SERIES
MYB-1206-33
MYB-1220-33
MYB-1210-33
MYB-1230-33
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
Attenuation (dB)
Attenuation (dB)
Attenuation (dB)
Attenuation (dB)
Symmetrical
Asymmetrical
Symmetrical
Asymmetrical
Symmetrical
Asymmetrical
Symmetrical
Asymmetrical
CHARACTERISTICS
Typical Insertion Loss
162
Noise
Filter
Features
(1) High attenuation effect against high voltage
pulse noise
(2) Compact and low profile (H = 65mm)
(3) Leakage current: 1mA max. (250V, 60Hz)
Safety standard
(1) MYB-1250-33, MYB-1290-33
Conforms to UL safety standard (UL1283)
Conforms to CSA safety standard
(CSA Std. C22. 2 No. 8)
(2) MYB-1270-33
UL1283, CSA Std. C22. 2 No. 8
Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
Contact us about delivery before ordering.
MYB
(50/70/90A)-SERIES
Circuit
Derating
Specifications
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Rated voltage (AC, DC)
Rated current (AC, DC)
(Note)
Test voltage (terminal to case, AC 1 minute)
Isolation resistance (terminal to case, 500VDC)
Leakage current
DC resistance
Temperature rise
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Vibration
Safety standard
Weight (typ)
250V
2500V (25C, 70% RH)
300M
min. (25C, 70% RH)
0.5mA max.
0.1mA max.
35C max
25 ~ +85C
30% ~ 90% RH (No dewdrop)
30 ~ +85C
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours
Only MYB-1270-33 is approved by UL 1283 and CSA std. C22. 2 No. 8
2.5m
max.
1.9m
max.
1.3m
max.
Item
Model
MYB-1250-33
MYB-1270-33
MYB-1290-33
50A
70A
90A
2000g
2900g
3000g
125V, 60Hz
250V, 60Hz
(Note) : Value at Ta 50C. Refer to the derating curve shown below at Ta > 50C.
MYB-1250-33
MYB-1270-33
MYB-1290-33
<
=
163
Noise
Filter
MYB
(50/70/90A)-SERIES
MYB-1250-33
MYB-1270-33
MYB-1290-33
Case: Metal
(Unit: mm)