ChipFind - документация

Электронный компонент: HX10-NP

Скачать:  PDF   ZIP
Electrical data
Primary nominal
Primary current
Primary Conductor
Type
r.m.s. current
measuring range
Diameter x Turns
I
PN
(A)
I
P
(A)
(mm)
Series Parallel Series Parallel
5 10
15
30
0.7d
x
(6T+6T)
HX 05-NP
10
20
30
60
1.0d
x
(3T+3T)
HX 10-NP
V
OUT
Output voltage @
I
PN
,
R
L
= 10 k
,
T
A
= 25C
4
V
R
OUT
Output impedance
< 50
R
L
Load resistance
10
k
V
C
Supply voltage ( 5 %)
1)
15
V
I
C
Current consumption
< 20
mA
V
d
R.m.s. voltage for AC isolation test,
50/60Hz, 1 mn
Primary to secondary
> 3
kV
Primary 1 to primary 2
> 1
kV
V
e
R.m.s. voltage for partial discharge extinction
at
10pC
1
kV
Impulse withstand voltage, 1.2/50s
6
kV
Accuracy-Dynamic performance data
X
Accuracy @
I
PN
,
T
A
= 25C (without offset)
< 1
% of
I
PN

L
Linearity (0 ..
I
PN
)
< 1
% of
I
PN
V
OE
Electrical offset voltage,
T
A
= 25C
< 40
mV
V
OH
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 3 x
I
PN
< 15
mV
V
OT
Thermal drift of
V
OE
max.
1.5
mV/K
TC

G
Thermal drift of the gain (% of reading)
0.1
%/K
t
r
Response time @ 90% of
I
P
3
s
f
Frequency bandwidth (-3 dB)
2)
50 kHz
General data
T
A
Ambient operating temperature
- 25 .. + 85
C
T
S
Ambient storage temperature
- 25 .. + 85
C
m
Mass
8
g
Min. internal creepage distance/clearance
5.5 mm
Isolation material group
I
Standards
EN50178
Current Transducer HX 05...10-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
=
5 .. 10 A
Notes :
1)
Also operate at 12V power supplies, measuring range reduced to 2.5x
I
PN
2)
Small signal only to avoid excessive heating of the magnetic core
011012/2
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
2 isolated primary windings
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x
I
PN
)
Power supply from 12V to 15V
Material according to UL94-V0
Advantages
Low insection losses
Easy to mount with automatic
handling system
Small size and space saving
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
LEM Components
www.lem.com
HX 05...10-NP
(in mm)
Specifications subject to change without notice.
10.85
6
10.85
1
2
3
4
5
6
1...... -15V
2...... 0V
3...... +15V
4...... Output
5...... Primary 1 input Current(-)
7...... Primary 1 input Current(+)
P=2.54
0.5
Terminal Pin Identification
19 Max.
20 Max.
6
15 Max.
- V
0
+ V
OUT
HX 05-NP
41123
Top view
4
4
7
8
6...... Primary 2 input Current(-)
8...... Primary 2 input Current(+)
3.5+/-0.3