ChipFind - документация

Электронный компонент: IT600-S

Скачать:  PDF   ZIP
IT 600-S
H
IGH
ACCURACY
CURRENT
TRANSDUCER
Basic specifications
Primary current I (max.)
0 .. 600 A
Polarity
Bipolar
Output current (max.)
0 .. 400 mA
Overload capacity :
Normal operation
100 %
Basic function maintained
110 %
Fault
500 % (0.1 s)
External Burden resistor - see fig. 1 :
Max.
100
Min.
2.5
Current transfer ratio
1500 : 1
Linearity
< 1 ppm
Measuring/ratio stability :
Initial
< 2 ppm
v.s. temperature
< 0.3 ppm/C
v.s. time
< 1 ppm/month
Offset :
Initial
4 A
v.s. temperature
0.1 A/C
Output noise (RMS) :
DC .. 10 Hz
< 0.02 A
DC .. 10 kHz
< 1.2 A
DC .. 50 kHz
< 4 A
Feedback noise (RMS), DC .. 50 kHz
(measured on the primary current cable - one turn)
< 10 V
(typ 5 V)
Busbar free zone (from center)
r > 70 mm
di/dt accurately followed
> 100 A/s
Bandwidth (3 dB, small signal 0.5 %)
DC .. 100 kHz
Test voltage (pin 4 - ground to a
25 busbar)
5 kV AC (RMS)
Operating temperature
10 .. 50C
Input power requirement
max. power consumption 5 VA
15 V < 5 %
+ 15 V : 200 mA, - 15 V : 50 mA
+ compensation current
Mechanical dimensions
122 x 98 x 57 mm
hole for busbar or cable :
26 mm
Weight
1 kg
All ppm figures refer to max. output current. Specifications are subject to change without notice.
We recommend that a shielded output cable and plug are used to ensure the maximum immunity
against electrostatic fields.
981014/3
LEM Components
w w w .lem.com
MAX BURDEN RESISTOR
Dimensions IT 600-S
Connection of Burden Resistor.
Burden Resistor value : see fig. 1
BURDEN RESISTOR VOLTAGE
Fig. 2.
The Voltage that can be achieved across the
externally connected Burden Resistor as a function
of the primary current.
Fig. 1.
Relationship between the externally
connected Burden Resistor and the
primary current.
9-
POLE
D-SUB
Pin 1
: (For factory use only)
Pin 2
: (Test pin for zero detector)
Pin 4
: 0 V and electrostatic shield
Pin 5
: - 15 V/50 mA
+ compensation current
Pin 6
: Current output
Pin 7
: (For factory use only)
Pin 9
: + 15 V/200 mA
+ compensation current.
Primary current (A)
Primary current (A)
IT 600 USER SIDE
IT 600-S INSTALLATION