ChipFind - документация

Электронный компонент: LV100-500

Скачать:  PDF   ZIP
Voltage Transducer LV 100-100
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
V
PN
Primary nominal r.m.s. voltage
100
V
V
P
Primary voltage, measuring range
0 .. 150
V
I
PN
Primary nominal r.m.s. current
100
mA
R
M
Measuring resistance
R
M min
R
M max
with 15 V
@ 100 V
max
0
170
@ 150 V
max
0
90
I
SN
Secondary nominal r.m.s. current
50
mA
K
N
Conversion ratio
100 V / 50 mA
V
C
Supply voltage ( 5 %)
15
V
I
C
Current consumption
10 + I
S
mA
V
d
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
6
kV
Accuracy - Dynamic performance data
X
G
Overall Accuracy @ V
PN
, T
A
= 25C
0.7
%
L
Linearity
< 0.1
%
Typ
Max
I
O
Offset current @ I
P
= 0, T
A
= 25C
0.2
mA
I
OT
Thermal drift of I
O
0C .. + 70C
0.2 0.3
mA
t
r
Response time
@ 90 % of V
P max
50
s
General data
T
A
Ambient operating temperature
0 .. + 70
C
T
S
Ambient storage temperature
- 25 .. + 85
C
N
Turns ratio
1000 : 2000
P
Total primary power loss
10
W
R
1
Primary resistance @ T
A
= 25C
1
k
R
S
Secondary coil resistance @ T
A
= 70C
60
m
Mass
850
g
Standards
1)
EN 50178
Note :
1)
A list of corresponding tests is available
Features
Closed loop (compensated) voltage
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0
Primary resistor R
1
incorporated into
the housing.
Advantages
Excellent accuracy
Very good linearity
Low thermal drift
High immunity to external
interference.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding
applications.
980709/1
V
PN
= 100 V
LEM Components
w w w .lem.com
Front view
Top view
Left view
Dimensions LV 100-100
(in mm. 1 mm = 0.0394 inch)
Remarks
I
S
is positive when V
P
is applied on terminal +HT.
The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Secondary terminals
Terminal + : supply voltage + 15 V
Terminal M : measure
Terminal - : supply voltage - 15 V
Terminal
: ground or earth
Connection
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Mechanical characteristics
General tolerance
0.3 mm
Fastening
2 holes
6.5 mm
Connection of primary
M5 threaded studs
Connection of secondary
Faston 6.3 x 0.8 mm
Connection to the ground
M5 threaded stud
Fastening torque
2.2 Nm or 1.62 Lb. -Ft.