ChipFind - документация

Электронный компонент: 4-1462000-8

Скачать:  PDF   ZIP
MT2 Relay
The Best Rela
y
tion
108-98006
Rev. C
EC-JM00-0009-03
ECOC: JM10
1. Apr. 04
2 pole telecom/signal relay
Through Hole Type (THT)
Non-polarized. non-latching 1 coil
Features
Telecom/signal relay (dry circuit, test access, ringing)
Slim line 20 x 10 mm, 0.795 x 0.393 inch
Switching current 2 A
2 changeover contacts (2 form C / DPDT)
Bifurcated contacts
Meets FCC Part 68 and ITU-T K20
Typical applications
Communications equipment
Linecard application analog, ISDN, xDSL
PABX
Voice over IP
Office and business equipment
Measurement and control equipment
Consumer electronics
Set top boxes, HiFi
Medical equipment
- Automotive Equipment
MT2 Relay
UL 508 File No. E 111441
IEC 61811-52:02
(QC160504)
Page 2 (9)
108-98006 Rev. C
European Directive conformance:
MT2 relay product conformance according to:
-
Directive 2000/53/EC: ELV (End of Life of Vehicles)
-
Directive 2002/95/EC: ROHS (Restrictions of the
use of certain hazardous substances in electrical and
electronic equipment)
Compliance is evidenced by written declaration from all raw
material suppliers.
Tyco Electronics AXICOM only has responsibility for the proper
processing of these materials.
Confirmation is valid for date codes 0416
MT2 Relay
THT Version
Basic grid 2.54 mm
Mounting hole layout
View onto the component side of the PCB
(top view)
Terminal assignment
Relay - top view
non-latching 1 coil
release condition
THT

mm inch
L 20.2 + 0.05/-0.02 0.795 + 0.002/-0.0008
W 10 + 0.05/-0.02 0.393 + 0.002/-0.0008
H 11+0.1/-0.2 0.433 + 0.004/-0.008
T 3.1 0.3 0.122 0.011
T1 N/A N/A
T2 7.62 0.15 0.3 0.005
S 0.55 0.021
Tw 0.5 0.020
Dimension
Page 3 (9)
108-98006 Rev. C
4.5 2.9 6.3 0.45 550 36
C 93438
7-1462000-7
5 3.3 7.0 0.5 550 45
C 93450
8-1462000-5
6 3.9 8.4 0.60 550 66
C 93437
7-1462000-6
12 7.8 16.8 1.20 550 280
C 93432
6-1462000-2
24 15.6 33.6 2.40 550 1050
C 93431
6-1462000-1
48 31.2 67.2 4.80 550 4100
C 93430
5-1462000-9
3 2.0 7.0 0.30 200 45 C 93414
1-1462001-1
4.5 2.9 10.5 0.45 200 101 C 93415
3-1462000-0
5 3.3 11.6 0.50 200 125 C 93416
3-1462000-1
6 3.9 14.0 0.60 200 180 C 93428
5-1462000-7
9 5.9 21.0 0.90 200 405 C 93417
3-1462000-6
12 7.8 28.0 1.20 200 720 C 93418
3-1462000-7
24 15.6 59.9 2.40 200 2880 C 93419
4-1462000-1
48 31.2 112.0 4.80 200 11520 C 93420
4-1462000-5
MT2 Relay
Sensitive version (300 mW)
non-latching 1 coil
Sensitive version (200 mW)
non-latching 1 coil
3 2.1 8.1 0.30 150 60 C 93400
1-1462001-2
4.5 3.2 12.2 0.45 150 136 C 93406
2-1462000-2
5 3.6 13.5 0.50 150 168 C 93401
0-1462000-1
6 4.3 16.2 0.60 150 240 C 93427
5-1462000-6
9 6.4 24.3 0.90 150 544 C 93405
2-1462000-0
12 8.6 32.4 1.20 150 968 C 93402
0-1462000-7
24 17.1 64.8 2.40 150 3872 C 93403
1-1462000-3
48 33.1 129.6 4.80 150 15468 C 93404
1-1462000-8
High sensitive version (150 mW)
non-latching 1 coil
Standard version (550 mW)
non-latching 1 coil
4.5 3.1 8.9 0.45 300 73 C 93433
6-1462000-6
5 3.4 9.9 0.50 300 90 C 93434
6-1462000-8
12 8.25 23.6 1.20 300 515 C 93412
2-1462000-6
24 16.5 47.3 2.40 300 2060 C 93435
7-1462000-0
48 32.5 54.6 4.80 300 8240 C 93436
7-1462000-2
4.5 2.9 8.9 0.45 400 50 C 93421
4-1462000-7
5 3.3 9.9 0.50 400 63 C 93422
4-1462000-8
6 3.9 11.8 0.60 400 90 C 93429
5-1462000-8
9 5.9 17.7 0.90 400 203 C 93423
5-1462000-0
12 7.8 23.6 1.20 400 360 C 93424
5-1462000-1
24 15.6 47.3 2.40 400 1440 C 93425
5-1462000-3
48 31.2 94.6 4.80 400 5760 C 93426
5-1462000-5
Standard version (400 mW)
non-latching 1 coil
Coil Data (values at 23C)
Nominal Operate/set voltage range Release/ Coil
Coil
Relay Tyco part
voltage reset voltage power
Resistance
code
number
Unom Minimum
Minimum Maximum
voltage U
min
voltage U
max
Vdc Vdc Vdc Vdc mW
/ 10 %
Ordering Information
Page 4 (9)
108-98006 Rev. C
MT2 Relay
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
-60 -50 -40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110 120
150 mW coil
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
-60 -50 -40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110 120
200 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-60 -50 -40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110 120
300 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-60 -50 -40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110 120
400 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-60 -50 -40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110 120
550 mW coil
U
nom
= Nominal coil voltage
U
max.
= Upper limit of the operative range of
the coil voltage (limiting voltage) when coils are
continously energized
U
op. min.
= Lower limit of the operative range of
the coil voltage (reliable operate voltage)

U
rel. min.
= Lower limit of the operative range of
the coil voltage (reliable release voltage)
Coil operating range
Page 5 (9)
108-98006 Rev. C
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
150 mW
200 mW
300 mW
400 mW
550 mW
U
nom.
nominal coil voltage