ChipFind - документация

Электронный компонент: T72M5D121-12

Скачать:  PDF   ZIP
PCB Relays
Single Relays
T72M
Please observe the disclaimer.
95
Powertrain
Systems
Chassis
Systems
Safety
Security
Body
Driver
Information
Convenience
Car Industry
Truck
Industry
Other
Industry
T72_3d02
Catalog 1308028
Revision 03-06
Revision 03-05
Description
Features
- 20 A, 16 V switching rating
- 60 A inrush at 16 V
- 15 A continuous contact rat-
ing at 105 C
- Immersion cleanable plastic
case with nipp-off pin for
ventilation
- Low profile package has a
seated height of only 0.67"
(17 mm)
Typical applications
- Lighting controls
- Power door locks, windows,
sunroof
- Seat controls
- Remote keyless entry
- Body computer
- Wiper/washer control
- ABS/Traction control
- Body control modules
- Power sliding door
Please contact Tyco Electronics
for relay application support.
Design
Sealed, immersion cleanable
Weight
Approx. 0.4 oz. (12 g)
Nominal voltage
6 V, 12 V or 24 V
Terminals
PCB terminals, for assembling in
printed circuit boards
Conditions
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
23 C ambient temperature,
20-50% RH, 29.5 1.0" Hg
(998.9 33.9 hPa).
Please also refer to the Application
Recommendations in this catalog
for general precautions.
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of
the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and
to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without
notification. All rights of Tyco are reserved.
PCB Relays
Single Relays
T72M
Please observe the disclaimer.
96
Catalog 1308028
Revision 03-06
Revision 03-05
Dimensional drawing
.03 MAX.
(.76)
.140
.020
(3.5
.51)
.040
(1.02)
.10 MIN.
(2.5)
SOLDER
.081
(2.06)
4 x
.020 x .045 MAX.
(.51 x 1.14)
.89 MAX.
(22.5)
.65 MAX.
(16.5)
.67 MAX.
(17.0)
ECR2200-Q
.052 TYP.
(1.3)
.480
(12.2)
.472
(12.0)
.236
(6.0)
.079
(2.0)
ECR2201-Y
3
2
5
1
4
View of the terminals (Bottom view)
Mounting holes
View of the terminals (Bottom view)
PCB Relays
Single Relays
T72M
Please observe the disclaimer.
97
Catalog 1308028
Revision 03-06
Revision 03-05
Contact data
Typical areas of application
Contact configuration
Circuit symbol
(see also Pin assignment)
Rated voltage
Rated current at 85 C
Contact material
Max. switching voltage/power
Max. switching current
1)
On
2)
Off
Min. recommended load
4)
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load)
Max. switching rate at nominal load
1)
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
2)
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
3)
Corresponds to a peak inrush current on initial actuation (cold filament).
4)
See chapter Diagnostics in our Application Recommendations on page 18 of this catalog or consult the internet at http://relays.tycoelectronics.com/application.asp
Resistive / inductive loads
Indicator / lamp loads
Changeover contact/
Form C
12 V
NC/NO
10/20 A
AgNi0.15
AgSnO
2
See load limit curve
NC/NO
NC/NO
12 A/60 A
15 A/80 A
3)
20 A/20 A
20 A/20 A
1 A at 5 V
Typ. 50 mV, 300 max. for NC/NO contacts
> 10
7
operations
10
5
operations at 20 A, 14 V,
resisitive load on NO contact
6 operations per minute (0.1 Hz)
4
3
1
Load limit curve
Pin assignment
60
50
40
30
20
10
100 W
0.5
1
2
3
4
5
7
10 12
20
Switching Current (A)
Switching Voltage (VDC)
200 W 250 W
75
320 W
40 W
ECR2202-7
Safe breaking, arc extinguished (normally open contact)
for resistive loads.
1 changeover contact/
1 form C
ECR2204-N
2
3
4
5
PCB Relays
Single Relays
T72M
Please observe the disclaimer.
98
Catalog 1308028
Revision 03-06
Revision 03-05
Ambient temperature vs. coil voltage for continuous duty
140
120
100
80
60
40
20
0
80
90
100
110
120
130
140
150
160
170
180
190
200
Applied Coil Voltage (% of Nominal Voltage)
Maximum Allowable
Ambient Temperature (
C)
0 A Contact Load
10 A Contact Load
15 A Contact Load
20 A Contact Load
ECR2203-F
Coil data
Available for nominal voltages
6, 12, 24 V
Nominal power consumption of the unsuppressed coil at nominal voltage
0.8 W
Test voltage winding/contact
500 VAC
rms
Maximum ambient temperature range
1)
40 to + 105 C
Operate time at nominal voltage
5 ms
Release time at nominal voltage
2)
2 ms
1)
See also diagram Ambient temparature vs. coil voltage for continuous duty.
2)
Measured at nominal voltage without coil suppression unit.
N.B.
A low resistive suppression device in parallel to the relay coil increases the release time and reduces
the lifetime caused by increased erosion and/or higher risk of contact tack welding.
Assumptions:
1. Still air
2. Nominal coil resistance
3. Maximum mean coil temperature = 155 C
4. Coil temperature rise due to load
= 8 C at 10 A
= 20 C at 15 A
35.5 C at 20 A
5. Curves are based on nominal coil power at 23 C
6. When full lifetime is at high ambient and high load current,
subtract 25 C from maximum allowable ambient temperature.
Mechanical data
Audible sound (14 V coil voltage)
95 dBA at 10 cm
77 dBA at 1 m
Enclosures
Sealed relay is suitable for immersion cleaning of PCB assembly.
Sealed
Please refer to the Application Recommendations in this catalog.
Relay may be vented after cleaning by cutting the vent protection from the corner of the
relay after processing using a razor knife or equivalent.
Operating conditions
Temperature range, storage
Refer to
Storage in the "Glossary"
Test
Relevant standard
Testing as per
Dimension
Comments
Vibration resistance
1.27 mm double amplitude
10-40 Hz
Valid for NC contacts.
5 g constant
40-70 Hz
NO contacts are
0.5 mm double amplitude
70-100 Hz
significantly higher
10 g constant
100-500 Hz
Shock resistance
half sine pulse form
11 ms
No change in the
20 g
switching state > 1 ms
Jump start
24 V for 5 minutes conducting nominal current at 23 C
Drop test
Capable of meeting specifications after 1.0 m (3.28 foot) drop onto concrete in final enclosure
Flammability
UL94-HB or better (meets FMVSS 302)
PCB Relays
Single Relays
T72M
Please observe the disclaimer.
99
Catalog 1308028
Revision 03-06
Revision 03-05
Ordering information
Coil versions
Standard delivery packs (orders in multiples of delivery pack)
T72M:
1000 pieces
Coil
Rated coil
Coil resistance
Must
Must
Allowable overdrive
1)
data for
voltage
+/- 10%
operate voltage
release voltage
voltage (V)
T72M
(V)
()
(V)
(V)
at 23 C
at 105 C
T72M*D***-**
6
45
3.2
0.6
12.3
7.2
T72M*D***-**
12
180
6.3
1.2
24.6
14.3
T72M*D***-**
24
720
12.6
2.4
49.3
28.7
1)
Allowable overdrive is stated with 10A load current flowing through the relay contacts and minimum coil resistance with power applied for 30 s max.
(20% max. duty cycle).
Part numbers
(see table below for coil data)
Contact
Contact
Enclosure
Terminals
Relay part number
Tyco order number
arrangement
material
T72M5D121-12
0-
1393289-9
1 Form C
AgNi0.15
Sealed, plastic cover
Printed circuit
T72M5D155-12
2-1393289-4
1 Form C
AgNi0.15
Sealed, plastic cover