ChipFind - документация

Электронный компонент: V23105A5302A201

Скачать:  PDF   ZIP
D2n Relay
The Best Rela
y
tion
108-98007
Rev. C
EC-JM00-0009-03
ECOC: JM10
1. Apr. 04
2 pole telecom relay, non-polarized,
Through Hole Type (THT)
Relay types:
non-latching with 1 coil
Features
Standard DIL relay
Dimensions 20.3 x 10.1 x 10.43 mm, 0.800 x 0.400 x 0.450 inch
Switching and continous current 3 A
2 changeover contacts (2 form C / DPDT)
Single contacts
Immersion cleanable
Four different coil sensitivities
(150, 200, 400, > 500 mW)
Surge voltage resistance meets FCC Part 68 requirement:
1.5 kV (10 / 160 sec) between coil and contacts
Typical applications
Communications equipment
Office equipment
Measurement and control equipment
Entertainment electronics
Medical Equipment
Consumer electronics
D2n Relay
UL 508 File No. E 111441
V23105
Page 2 (11)
108-98007 Rev. C
European Directive conformance:
D2n relay product conformance according to:
-
Directive 2000/53/EC: ELV (End of Life of Vehicles)
-
Directive 2002/95/EC: ROHS (Restrictions of the
use of certain hazardous substances in electrical and
electronic equipment)
Compliance is evidenced by written declaration from all raw
material suppliers.
Tyco Electronics AXICOM only has responsibility for the proper
processing of these materials.
Confirmation is valid for date codes 0418
D2n Relay
Dimensions
THT Version
Basic grid 2.54 mm
Mounting hole layout
View onto the component side of the PCB
(top view)
Terminal assignment
Relay - top view
THT
V23105-A5xxx-A201
mm inch
L 20.2 0.1 0.795 0.004
W 10.0 0.1 0.394 0.004
H 11.43 0.2 0.450 - 0.008
T 3.5 0.3 0.138 0.012
Tw 0.72 - 0.2 0.028 - 0.008
S 0.3 0.1 0.012 0.004
V23105
Page 3 (11)
108-98007 Rev. C
5 3.5 7.2 0.25 400 62 V23105A5401A201 0-1393793-6
6 4.2 8.6 0.30 400 90 V23105A5402A201 0-1393793-7
9 6.3 12.9 0.45 400 203 V23105A5406A201 1-1393793-0
12 8.4 17.2 0.60 400 360 V23105A5403A201 0-1393793-8
24 16.8 34.3 1.20 400 1440 V23105A5405A201 0-1393793-9
48 33.6 68.6 2.40 400 5760 V23105A5407A201 1-1393793-1
D2n Relay
400 mW nominal power consumption
3 2.1 6.1 0.15 200 45 V23105A5308A201 0-1393793-5
5 3.5 10.1 0.25 200 125 V23105A5301A201 9-1393792-3
6 4.2 12.2 0.30 200 180 V23105A5302A201 9-1393792-5
9 6.3 18.2 0.45 200 405 V23105A5306A201 0-1393793-2
12 8.4 24.3 0.60 200 720 V23105A5303A201 9-1393792-7
24 16.8 48.6 1.20 200 2880 V23105A5305A201 9-1393792-9
48 33.6 97.2 2.40 200 11520 V23105A5307A201 0-1393793-3
200 mW nominal power consumption
5 4.0 11.7 0.25 150 167
V23105A5001A201 8-1393792-5
6 4.8 14.0 0.30 150 240
V23105A5002A201 8-1393792-7
9 7.2 21.0 0.45 150 540
V23105A5006A201 9-1393792-1
12 9.6 28.0 0.60 150 960
V23105A5003A201 8-1393792-8
24 19.2 56.0 1.20 165 3480
V23105A5005A201 9-1393792-0
150 mW nominal power consumption
5 3.5 6.1 0.25 695 36 V23105A5501A201 1-1393793-6
6 4.2 7.3 0.30 515 70 V23105A5502A201 1-1393793-8
9 6.3 10.9 0.45 580 140 V23105A5506A201 2-1393793-3
12 8.4 14.5 0.60 515 280 V23105A5503A201 1-1393793-9
24 16.8 29.1 1.20 550 1050 V23105A5505A201 2-1393793-1
48 33.6 58.1 2.40 575 4000 V23105A5507A201 2-1393793-4
> 500 mW nominal power consumption
V23105
Page 4 (11)
108-98007 Rev. C
Coil versions, BT 47 type / specification T4563 C (current tested)
Nominal Operating Nominal power Resistance British Relay code Tyco
voltage current consumption Telecom Code Part Number

Vdc mA mW W / 10 %
5 80 695 36 47 W / 5 V23105A5475A201 1-1393793-2
10 32.5 500 200 47 W / 9 V23105A5479A201 3-1393794-0
12 27 515 280 47 W / 6 V23105A5476A201 1-1393793-3
24 14 550 1050 47 W / 7 V23105A5477A201 1-1393793-4
48 7 575 4000 47 W / 8 V23105A5478A201 1-1393793-5
Coil Data (values at 23C)
Nominal Operate/set voltage range Release/ Coil
Coil
Relay Tyco part
voltage reset voltage power
Resistance
code
number
Unom Minimum
Minimum Maximum
voltage U
min
voltage U
max
Vdc Vdc Vdc Vdc mW
/ 10 %
Ordering Information
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30
-20
-10
0
10
20
30
40
50
60
70
80
90 100 110 120
550 mW coil
D2n Relay
V23105
Page 5 (11)
108-98007 Rev. C
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30
-20
-10
0
10
20
30
40
50
60
70
80
90 100 110 120
150 mW coil
U
nom
= Nominal coil voltage
U
max.
= Upper limit of the operative range of
the coil voltage (limiting voltage) when coils are
continously energized
U
op. min.
= Lower limit of the operative range of
the coil voltage (reliable operate voltage)

U
rel. min.
= Lower limit of the operative range of
the coil voltage (reliable release voltage)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
-30 -20 -10
0
10 20
30
40 50
60
70 80
90 100 110 120
200 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30
-20
-10
0
10
20
30
40
50
60
70
80
90 100 110 120
400 mW coil
Coil operating range
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
U
max.
at 0 A
U
max.
at 2 x 2 A
U
max.
at 2 x 1 A
U
nom.
nominal coil voltage
U
op. min.
U
rel. min.
Ambient Temperature [C]
Coil Voltage [U/U
nom
]
150 mW
200 mW
400 mW
550 mW