ChipFind - документация

Электронный компонент: SS18

Скачать:  PDF   ZIP
SS12
THRU
SS110
1 Amp Schottky
Rectifier
20 to 100 Volts
Features
Schottky Barrier Rectifier
Guard Ring Protection
Low Forward Voltage
Reverse Energy Tested
High Current Capability
Extremely Low Thermal Resistance
Maximum Ratings
Operating Temperature: -55
C to +125
C
Storage Temperature: -55
C to +150
C
Maximum Thermal Resistance; 35
C/W Junction To Lead
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
SS12
SS12
20V
14V
20V
SS13
SS13
30V
21V
30V
SS14
SS14
40V
28V
40V
SS15
SS15
50V
35V
50V
SS16
SS16
60V
42V
60V
SS18
SS18
80V
56V
80V
SS110 SS110 100V 70V 100V
Electrical Characteristics @ 25
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
1.0A
T
J
= 100
C
Peak Forward Surge
Current
I
FSM
30A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
SS12
SS13
SS14
SS15-16
SS18-110
V
F
.45V
.55V
.60V
.70V
.85V
I
FM
= 1.0A;
T
J
= 25
C*
Typical Junction
Capacitance
SS12 - SS16
SS18-SS110
C
J
110pF
20pF
Measured at
1.0MHz, V
R
=4.0V
*Pulse test: Pulse width 300
sec, Duty cycle 2%
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
0.5mA
20mA
T
A
= 25
C
T
A
= 100
C
www.
mccsemi
.com
H
J
E
F
G
A
B
D
C
Cathode Band
0.070"
0.090"
0.085"
SUGGESTED SOLDER
PAD LAYOUT
DIMENSIONS
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A .078 .116 1.98 2.95
B .067 .089 1.70 2.25
C .002 .008 .05 .20
D --- .02 --- .51
E .035 .055 .89 1.40
F .065 .096 1.65 2.45
G .205 .224 5.21 5.69
H .160 .180 4.06 4.57
J .100 .112 2.57 2.84
DO-214AC
(SMAJ) (High Profile)
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
SS12 thru SS110
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.4
.6
.8
1.0
1.2
1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
C
Volts
SS13,SS14
SS15-SS16
SS18-SS110
M C C
www.
mccsemi
.com
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.2
.4
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
C
150
.8
1.0
1.2
1
100
4
0
10
5
20
30
8
Figure 3
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20
60 80
40
40
50
60
SS12