ChipFind - документация

Электронный компонент: 29F400C-55

Скачать:  PDF   ZIP
1
P/N:PM1200
REV. 1.0, DEC. 20, 2005
MX29F400C T/B
4M-BIT [512Kx8/256Kx16] CMOS SINGLE VOLTAGE
5V ONLY BOOT SECTOR FLASH MEMORY
Ready/Busy pin (RY/BY#)
- Provides a hardware method of detecting program or
erase cycle completion
Sector protect/chip unprotect for 5V only system
Sector protection
- Hardware method to disable any combination of
sectors from program or erase operations
- Temporary sector unprotect allows code changes in
previously locked sectors
100,000 minimum erase/program cycles
Latch-up protected to 100mA from -1V to VCC+1V
Boot Code Sector Architecture
- T = Top Boot Sector
- B = Bottom Boot Sector
Low VCC write inhibit is equal to or less than 3.2V
Package type:
- 44-pin SOP
- 48-pin TSOP
- All Pb-free devices are RoHS Compliant
Compatibility with JEDEC standard
- Pinout and software compatible with single-power
supply Flash
20 years data retention
FEATURES
524,288 x 8/262,144 x 16 switchable
Single power supply operation
- 5.0V only operation for read, erase and program
operation
Fast access time: 55/70/90ns
Compatible with MX29F400T/B device
Low power consumption
- 40mA maximum active current(5MHz)
- 1uA typical standby current
Command register architecture
- Byte/word Programming (9us/11us typical)
- Sector Erase (Sector structure 16K-Bytex1, 8K-
Bytex2, 32K-Bytex1, and 64K-Byte x7)
Auto Erase (chip & sector) and Auto Program
- Automatically erase any combination of sectors with
Erase Suspend capability.
- Automatically program and verify data at specified
address
Erase suspend/Erase Resume
- Suspends an erase operation to read data from, or
program data to, another sector that is not being
erased, then resumes the erase
Status Reply
- Data# Polling & Toggle bit for detection of program
and erase cycle completion
GENERAL DESCRIPTION
The MX29F400C T/B is a 4-mega bit Flash memory or-
ganized as 512K bytes of 8 bits or 256K words of 16 bits.
MXIC's Flash memories offer the most cost-effective and
reliable read/write non-volatile random access memory.
The MX29F400C T/B is packaged in 44-pin SOP, 48-pin
TSOP. It is designed to be reprogrammed and erased in
system or in standard EPROM programmers.
The standard MX29F400C T/B offers access time as
fast as 55ns, allowing operation of high-speed micropro-
cessors without wait states. To eliminate bus conten-
tion, the MX29F400C T/B has separate chip enable (CE#)
and output enable (OE#) controls.
MXIC's Flash memories augment EPROM functionality
with in-circuit electrical erasure and programming. The
MX29F400C T/B uses a command register to manage
this functionality. The command register allows for 100%
TTL level control inputs and fixed power supply levels
during erase and programming, while maintaining maxi-
mum EPROM compatibility.
MXIC Flash technology reliably stores memory contents
even after 100,000 erase and program cycles. The MXIC
cell is designed to optimize the erase and programming
mechanisms. In addition, the combination of advanced
tunnel oxide processing and low internal electric fields
for erase and program operations produces reliable cy-
cling. The MX29F400C T/B uses a 5.0V
10% VCC sup-
ply to perform the High Reliability Erase and auto Pro-
gram/Erase algorithms.
The highest degree of latch-up protection is achieved
with MXIC's proprietary non-epi process. Latch-up pro-
tection is proved for stresses up to 100 milliamps on
address and data pin from -1V to VCC + 1V.
2
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
PIN CONFIGURATIONS
44 SOP(500 mil)
PIN DESCRIPTION
SYMBOL PIN NAME
A0~A17
Address Input
Q0~Q14
Data Input/Output
Q15/A-1
Q15(Word mode)/LSB addr(Byte mode)
CE#
Chip Enable Input
WE#
Write Enable Input
BYTE#
Word/Byte Selection input
RESET#
Hardware Reset Pin/Sector Protect
Unlock
OE#
Output Enable Input
RY/BY#
Ready/Busy Output
VCC
Power Supply Pin (+5V)
GND
Ground Pin
48 TSOP (Standard Type) (12mm x 20mm)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
NC
RY/BY#
A17
A7
A6
A5
A4
A3
A2
A1
A0
CE#
GND
OE#
Q0
Q8
Q1
Q9
Q2
Q10
Q3
Q11
RESET#
WE#
A8
A9
A10
A11
A12
A13
A14
A15
A16
BYTE#
GND
Q15/A-1
Q7
Q14
Q6
Q13
Q5
Q12
Q4
VCC
MX29F400CT/CB
A15
A14
A13
A12
A11
A10
A9
A8
NC
NC
WE#
RESET#
NC
NC
RY/BY#
NC
A17
A7
A6
A5
A4
A3
A2
A1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
A16
BYTE#
GND
Q15/A-1
Q7
Q14
Q6
Q13
Q5
Q12
Q4
VCC
Q11
Q3
Q10
Q2
Q9
Q1
Q8
Q0
OE#
GND
CE#
A0
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
MX29F400CT/CB
3
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
Sector Size
Address Range (in hexadecimal)
(Kbytes/
(x8)
(x16)
Sector
A17
A16
A15
A14
A13
A12
Kwords)
Address Range
Address Range
SA0
0
0
0
X
X
X
64/32
00000h-0FFFFh
00000h-07FFFh
SA1
0
0
1
X
X
X
64/32
10000h-1FFFFh
08000h-0FFFFh
SA2
0
1
0
X
X
X
64/32
20000h-2FFFFh
10000h-17FFFh
SA3
0
1
1
X
X
X
64/32
30000h-3FFFFh
18000h-1FFFFh
SA4
1
0
0
X
X
X
64/32
40000h-4FFFFh
20000h-27FFFh
SA5
1
0
1
X
X
X
64/32
50000h-5FFFFh
28000h-2FFFFh
SA6
1
1
0
X
X
X
64/32
60000h-6FFFFh
30000h-37FFFh
SA7
1
1
1
0
X
X
32/16
70000h-77FFFh
38000h-3BFFFh
SA8
1
1
1
1
0
0
8/4
78000h-79FFFh
3C000h-3CFFFh
SA9
1
1
1
1
0
1
8/4
7A000h-7BFFFh
3D000h-3DFFFh
SA10
1
1
1
1
1
X
16/8
7C000h-7FFFFh
3E000h-3FFFFh
Sector Size
Address Range (in hexadecimal)
(Kbytes/
(x8)
(x16)
Sector
A17
A16
A15
A14
A13
A12
Kwords)
Address Range
Address Range
SA0
0
0
0
0
0
X
16/8
00000h-03FFFh
00000h-01FFFh
SA1
0
0
0
0
1
0
8/4
04000h-05FFFh
02000h-02FFFh
SA2
0
0
0
0
1
1
8/4
06000h-07FFFh
03000h-03FFFh
SA3
0
0
0
1
X
X
32/16
08000h-0FFFFh
04000h-07FFFh
SA4
0
0
1
X
X
X
64/32
10000h-1FFFFh
08000h-0FFFFh
SA5
0
1
0
X
X
X
64/32
20000h-2FFFFh
10000h-17FFFh
SA6
0
1
1
X
X
X
64/32
30000h-3FFFFh
18000h-1FFFFh
SA7
1
0
0
X
X
X
64/32
40000h-4FFFFh
20000h-27FFFh
SA8
1
0
1
X
X
X
64/32
50000h-5FFFFh
28000h-2FFFFh
SA9
1
1
0
X
X
X
64/32
60000h-6FFFFh
30000h-37FFFh
SA10
1
1
1
X
X
X
64/32
70000h-7FFFFh
38000h-3FFFFh
Note: Address range is A17~A-1 in byte mode and A17~A0 in word mode.
SECTOR STRUCTURE
MX29F400CT TOP BOOT SECTOR ADDRESS TABLE
MX29F400CB BOTTOM BOOT SECTOR ADDRESS TABLE
4
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
BLOCK DIAGRAM
CONTROL
INPUT
LOGIC
PROGRAM/ERASE
HIGH VOLTAGE
WRITE
STATE
MACHINE
(WSM)
STATE
REGISTER
FLASH
ARRAY
X-DECODER
ADDRESS
LATCH
AND
BUFFER
Y-PASS GATE
Y
-DECODER
ARRAY
SOURCE
HV
COMMAND
DATA
DECODER
COMMAND
DATA LATCH
I/O BUFFER
PGM
DATA
HV
PROGRAM
DATA LATCH
SENSE
AMPLIFIER
Q0-Q15/A-1
A0-A17
CE#
OE#
WE#
5
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC PROGRAMMING
The MX29F400C T/B is byte programmable using the
Automatic Programming algorithm. The Automatic Pro-
gramming algorithm makes the external system do not
need to have time out sequence nor to verify the data
programmed. The typical chip programming time at room
temperature of the MX29F400C T/B is less than 4.5 sec-
onds.
AUTOMATIC CHIP ERASE
The entire chip is bulk erased using 10 ms erase pulses
according to MXIC's Automatic Chip Erase algorithm.
Typical erasure at room temperature is accomplished in
less than 4 second. The Automatic Erase algorithm au-
tomatically programs the entire array prior to electrical
erase. The timing and verification of electrical erase are
controlled internally within the device.
AUTOMATIC SECTOR ERASE
The MX29F400C T/B is sector(s) erasable using MXIC's
Auto Sector Erase algorithm. Sector erase modes allow
sectors of the array to be erased in one erase cycle. The
Automatic Sector Erase algorithm automatically programs
the specified sector(s) prior to electrical erase. The tim-
ing and verification of electrical erase are controlled in-
ternally within the device.
AUTOMATIC PROGRAMMING ALGORITHM
MXIC's Automatic Programming algorithm requires the
user to only write program set-up commands (including 2
unlock write cycle and A0H) and a program command
(program data and address). The device automatically
times the programming pulse width, provides the pro-
gram verification, and counts the number of sequences.
A status bit similar to Data# Polling and a status bit tog-
gling between consecutive read cycles, provide feedback
to the user as to the status of the programming opera-
tion.
AUTOMATIC ERASE ALGORITHM
MXIC's Automatic Erase algorithm requires the user to
write commands to the command register using stan-
dard microprocessor write timings. The device will auto-
matically pre-program and verify the entire array. Then
the device automatically times the erase pulse width,
provides the erase verification, and counts the number
of sequences. A status bit toggling between consecu-
tive read cycles provides feedback to the user as to the
status of the programming operation.
Register contents serve as inputs to an internal state-
machine which controls the erase and programming cir-
cuitry. During write cycles, the command register inter-
nally latches address and data needed for the program-
ming and erase operations. During a system write cycle,
addresses are latched on the falling edge, and data are
latched on the rising edge of WE# or CE#, whichever
happens first .
MXIC's Flash technology combines years of EPROM
experience to produce the highest levels of quality, reli-
ability, and cost effectiveness. The MX29F400C T/B elec-
trically erases all bits simultaneously using Fowler-
Nordheim tunneling. The bytes are programmed by us-
ing the EPROM programming mechanism of hot electron
injection.
During a program cycle, the state-machine will control
the program sequences and command register will not
respond to any command set. During a Sector Erase
cycle, the command register will only respond to Erase
Suspend command. After Erase Suspend is completed,
the device stays in read mode. After the state machine
has completed its task, it will allow the command regis-
ter to respond to its full command set.
6
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
First Bus
Second Bus Third Bus
Fourth Bus
Fifth Bus
Sixth Bus
Command
Bus
Cycle
Cycle
Cycle
Cycle
Cycle
Cycle
Cycle Addr
Data
Addr
Data
Addr
Data
Addr
Data
Addr
Data Addr
Data
Reset
1
XXXH F0H
Read
1
RA
RD
Read Silicon
Word
4
555H AAH
2AAH 55H
555H
90H
ADI
DDI
ID
Byte
4
AAAH AAH
555H 55H
AAAH 90H
ADI
DDI
Sector Protect
Word
4
555H AAH
2AAH 55H
555H
90H
(SA)
XX00H
Verify
x02H XX01H
Byte
4
AAAH AAH
555H 55H
AAAH 90H
(SA)
00H
x04H 01H
Program
Word
4
555H AAH
2AAH 55H
555H
A0H
PA
PD
Byte
4
AAAH AAH
555H 55H
AAAH A0H
PA
PD
Chip Erase
Word
6
555H AAH
2AAH 55H
555H
80H
555H AAH
2AAH 55H
555H 10H
Byte
6
AAAH AAH
555H 55H
AAAH 80H
AAAH AAH
555H
55H
AAAH 10H
Sector Erase
Word
6
555H AAH
2AAH 55H
555H
80H
555H AAH
2AAH 55H
SA
30H
Byte
6
AAAH AAH
555H 55H
AAAH 80H
AAAH AAH
555H
55H
SA
30H
Sector Erase Suspend
1
XXXH B0H
Sector Erase Resume
1
XXXH 30H
Unlock for sector
6
555H AAH
2AAH 55H
555H
80H
555H AAH
2AAH 55H
555H 20H
protect/unprotect
TABLE 1. SOFTWARE COMMAND DEFINITIONS
Note:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacture code,A1=0, A0 = 1 for device code, A2~A17=do not care.
(Refer to table 3)
DDI = Data of Device identifier : C2H for manufacture code, 23H/ABH (x8) and 2223H/22ABH (x16) for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2. PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address to the sector to be erased.
3. The system should generate the following address patterns: 555H or 2AAH to Address A10~A0 in word mode/AAAH or
555H to Address A10~A-1 in byte mode.
Address bit A11~A17=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A11~A17 in either state.
4. For Sector Protect Verify operation:If read out data is 01H, it means the sector has been protected. If read out data is 00H, it
means the sector is still not being protected.
7
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
Pins
CE#
OE#
WE#
A0
A1
A6
A9
Q0 ~ Q15
Mode
Read Silicon ID
L
L
H
L
L
X
V
ID
(2)
C2H (Byte mode)
Manufacture Code(1)
00C2H (Word mode)
Read Silicon ID
L
L
H
H
L
X
V
ID
(2)
23H/ABH (Byte mode)
Device Code(1)
2223H/22ABH (Word mode)
Read
L
L
H
A0
A1
A6
A9
D
OUT
Standby
H
X
X
X
X
X
X
HIGH Z
Output Disable
L
H
H
X
X
X
X
HIGH Z
Write
L
H
L
A0
A1
A6
A9
D
IN
(3)
Sector Protect without 12V
L
H
L
X
X
L
H
X
system (6)
Chip Unprotect without 12V
L
H
L
X
X
H
H
X
system (6)
Verify Sector Protect/Unprotect L
L
H
X
H
X
H
Code(5)
without 12V system (7)
Reset
X
X
X
X
X
X
X
HIGH Z
TABLE 2. MX29F400C T/B BUS OPERATION
NOTES:
1. Manufacturer and device codes may also be accessed via a command register write sequence. Refer to Table 1.
2. VID is the Silicon-ID-Read high voltage, 11.5V to 12.5V.
3. Refer to Table 1 for valid Data-In during a write operation.
4. X can be VIL or VIH.
5. Code=00H/XX00H means unprotected.
Code=01H/XX01H means protected.
A17~A12=Sector address for sector protect.
6. Refer to sector protect/unprotect algorithm and waveform.
Must issue "unlock for sector protect/unprotect" command before "sector protect/unprotect without 12V system"
command.
7. The "verify sector protect/unprotect without 12V system" is only following "Sector protect/unprotect without 12V
system" command.
Note that the Erase Suspend (B0H) and Erase Resume
(30H) commands are valid only while the Sector Erase
operation is in progress. Either of the two reset com-
mand sequences will reset the device(when applicable).
COMMAND DEFINITIONS
Device operations are selected by writing specific address
and data sequences into the command register. Writing
incorrect address and data values or writing them in the
improper sequence will reset the device to the read mode.
Table 1 defines the valid register command sequences.
8
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
READ/RESET COMMAND
The read or reset operation is initiated by writing the
read/reset command sequence into the command reg-
ister. Microprocessor read cycles retrieve array data.
The device remains enabled for reads until the command
register contents are altered.
If program-fail or erase-fail happen, the write of F0H will
reset the device to abort the operation. A valid com-
mand must then be written to place the device in the
desired state.
SILICON-ID-READ COMMAND
Flash memories are intended for use in applications where
the local CPU alters memory contents. As such, manu-
facturer and device codes must be accessible while the
device resides in the target system. PROM program-
mers typically access signature codes by raising A9 to
a high voltage. However, multiplexing high voltage onto
address lines is not generally desired system design
practice.
The MX29F400C T/B contains a Silicon-ID-Read opera-
tion to supplement traditional PROM programming meth-
odology. The operation is initiated by writing the read
silicon ID command sequence into the command regis-
ter. Following the command write, a read cycle with
A1=VIL,A0=VIL retrieves the manufacturer code of C2H/
00C2H. A read cycle with A1=VIL, A0=VIH returns the
device code of 23H/2223H for MX29F400CT, ABH/22ABH
for MX29F400CB.
SET-UP AUTOMATIC CHIP/SECTOR ERASE
Pins
A0
A1
Q15~Q8 Q7
Q6
Q5
Q4
Q3
Q2 Q1
Q0
Code(Hex)
Manufacture code
Word
VIL
VIL
00H
1
1
0
0
0
0
1
0
00C2H
Byte
VIL
VIL
X
1
1
0
0
0
0
1
0
C2H
Device code
Word
VIH
VIL
22H
0
0
1
0
0
0
1
1
2223H
for MX29F400CT
Byte
VIH
VIL
X
0
0
1
0
0
0
1
1
23H
Device code
Word
VIH
VIL
22H
1
0
1
0
1
0
1
1
22ABH
for MX29F400CB
Byte
VIH
VIL
X
1
0
1
0
1
0
1
1
ABH
Sector Protection
X
VIH
X
0
0
0
0
0
0
0
1
01H (Protected)
Verification
X
VIH
X
0
0
0
0
0
0
0
0
00H (Unprotected)
TABLE 3. EXPANDED SILICON ID CODE
COMMANDS
Chip erase is a six-bus cycle operation. There are two
"unlock" write cycles. These are followed by writing the
"set-up" command 80H. Two more "unlock" write cy-
cles are then followed by the chip erase command 10H.
The Automatic Chip Erase does not require the device
to be entirely pre-programmed prior to executing the Au-
tomatic Chip Erase. Upon executing the Automatic Chip
Erase, the device will automatically program and verify
the entire memory for an all-zero data pattern. When the
device is automatically verified to contain an all-zero
pattern, a self-timed chip erase and verify begin. The
erase and verify operations are completed when the data
on Q7 is "1" at which time the device returns to the
Read mode. The system is not required to provide any
control or timing during these operations.
When using the Automatic Chip Erase algorithm, note
that the erase automatically terminates when adequate
erase margin has been achieved for the memory array(no
erase verification command is required).
If the Erase operation was unsuccessful, the data on
Q5 is "1"(see Table 4), indicating the erase operation
exceed internal timing limit.
The automatic erase begins on the rising edge of the
last WE# or CE#, whichever happens later, pulse in the
command sequence and terminates when the data on
Q7 is "1" and the data on Q6 stops toggling for two con-
secutive read cycles, at which time the device returns
to the Read mode.
9
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
Status
Q7
Q6
Q5
Q3
Q2
RY/BY#
Note1
Note2
Byte Program in Auto Program Algorithm
Q7#
Toggle
0
N/A
No
0
Toggle
Auto Erase Algorithm
0
Toggle
0
1
Toggle
0
Erase Suspend Read
1
No
0
N/A Toggle
1
(Erase Suspended Sector)
Toggle
In Progress
Erase Suspended Mode
Erase Suspend Read
Data
Data
Data
Data
Data
1
(Non-Erase Suspended Sector)
Erase Suspend Program
Q7#
Toggle
0
N/A
N/A
0
Byte Program in Auto Program Algorithm
Q7#
Toggle
1
N/A
No
0
Toggle
Exceeded
Time Limits Auto Erase Algorithm
0
Toggle
1
1
Toggle
0
Erase Suspend Program
Q7#
Toggle
1
N/A
N/A
0
erase margin has been achieved for the memory array
(no erase verification command is required). Sector
erase is a six-bus cycle operation. There are two "un-
lock" write cycles. These are followed by writing the set-
up command 80H. Two more "unlock" write cycles are
then followed by the sector erase command 30H. The
sector address is latched on the falling edge of WE# or
CE#, whichever happens later, while the command(data)
is latched on the rising edge of WE# or CE#, whichever
happens first. Sector addresses selected are loaded
into internal register on the sixth falling edge of WE# or
CE#, whichever happens later. Each successive sector
load cycle started by the falling edge of WE# or CE#,
whichever happens later, must begin within 30us from
the rising edge of the preceding WE# or CE#, whichever
happens First, otherwise, the loading period ends and
internal auto sector erase cycle starts. (Monitor Q3 to
determine if the sector erase timer window is still open,
see section Q3, Sector Erase Timer.) Any command other
than Sector Erase(30H) or Erase Suspend(B0H) during
the time-out period resets the device to read mode.
SECTOR ERASE COMMANDS
The Automatic Sector Erase does not require the de-
vice to be entirely pre-programmed prior to executing
the Automatic Set-up Sector Erase command and Auto-
matic Sector Erase command. Upon executing the Au-
tomatic Sector Erase command, the device will auto-
matically program and verify the sector(s) memory for
an all-zero data pattern. The system is not required to
provide any control or timing during these operations.
When the sector(s) is automatically verified to contain
an all-zero pattern, a self-timed sector erase and verify
begin. The erase and verify operations are complete
when the data on Q7 is "1" and the data on Q6 stops
toggling for two consecutive read cycles, at which time
the device returns to the Read mode. The system is not
required to provide any control or timing during these
operations.
When using the Automatic Sector Erase algorithm, note
that the erase automatically terminates when adequate
Table 4. Write Operation Status
Note:
1. Q7 and Q2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
2. Q5 switches to '1' when an Auto Program or Auto Erase operation has exceeded the maximum timing limits.
See "Q5:Exceeded Timing Limits " for more information.
10
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
ERASE SUSPEND
This command only has meaning while the state ma-
chine is executing Automatic Sector Erase operation, and
therefore will only be responded during Automatic Sector
Erase operation. When the Erase Suspend command is
written during a sector erase operation, the device re-
quires a maximum of 20us to suspend the erase opera-
tions. However, When the Erase Suspend command is
written during the sector erase time-out, the device im-
mediately terminates the time-out period and suspends
the erase operation. After this command has been ex-
ecuted, the command register will initiate erase suspend
mode. The state machine will return to read mode auto-
matically after suspend is ready. At this time, state ma-
chine only allows the command register to respond to
the Read Memory Array, Erase Resume and program
commands.
The system can determine the status of the program
operation using the Q7 or Q6 status bits, just as in the
standard program operation. After an erase-suspend pro-
gram operation is complete, the system can once again
read array data within non-suspended sectors.
ERASE RESUME
This command will cause the command register to clear
the suspend state and return back to Sector Erase mode
but only if an Erase Suspend command was previously
issued. Erase Resume will not have any effect in all
other conditions. Another Erase Suspend command can
be written after the chip has resumed erasing. However,
a 400us time delay must be required after the erase re-
sume command, if the system implements an endless
erase suspend/resume loop, or the number of erase sus-
pend/resume is exceeded 1024 times. The erase times
will be expended if the erase behavior always be sus-
pended.
SET-UP AUTOMATIC PROGRAM COMMANDS
To initiate Automatic Program mode, A three-cycle com-
mand sequence is required. There are two "unlock" write
cycles. These are followed by writing the Automatic Pro-
gram command A0H.
Once the Automatic Program command is initiated, the
next WE# or CE#, pulse causes a transition to an active
programming operation. Addresses are latched on the
falling edge, and data are internally latched on the
rising edge of the WE# or CE#, whichever happens first,
pulse. The rising edge of WE# or CE#, whichever hap-
pens first, also begins the programming operation. The
system is not required to provide further controls or tim-
ings. The device will automatically provide an adequate
internally generated program pulse and verify margin.
If the program operation was unsuccessful, the data on
Q5 is "1"(see Table 4), indicating the program operation
exceed internal timing limit. The automatic programming
operation is completed when the data read on Q6 stops
toggling for two consecutive read cycles and the data
on Q7 and Q6 are equivalent to data written to these two
bits, at which time the device returns to the Read mode(no
program verify command is required).
DATA# POLLING-Q7
The MX29F400C T/B also features Data# Polling as a
method to indicate to the host system that the Auto-
matic Program or Erase algorithms are either in progress
or completed.
While the Automatic Programming algorithm is in opera-
tion, an attempt to read the device will produce the
complement data of the data last written to Q7. Upon
completion of the Automatic Program Algorithm an at-
tempt to read the device will produce the true data last
written to Q7. The Data# Polling feature is valid after the
rising edge of the fourth WE# or CE#, whichever hap-
pens first, pulse of the four write pulse sequences for
automatic program.
While the Automatic Erase algorithm is in operation, Q7
will read "0" until the erase operation is competed. Upon
completion of the erase operation, the data on Q7 will
read "1". The Data# Polling feature is valid after the
rising edge of the sixth WE# or CE#, whichever happens
first pulse of six write pulse sequences for automatic
chip/sector erase.
The Data# Polling feature is active during Automatic Pro-
gram/Erase algorithm or sector erase time-out. (see sec-
tion Q3 Sector Erase Timer)
11
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
RY/BY#:Ready/Busy#
The RY/BY# is a dedicated, open-drain output pin that
indicates whether an Automatic Erase/Program algorithm
is in progress or complete. The RY/BY# status is valid
after the rising edge of the final WE# or CE#, whichever
happens first, pulse in the command sequence. Since
RY/BY# is an open-drain output, several RY/BY# pins
can be tied together in parallel with a pull-up resistor to
Vcc.
If the output is low (Busy), the device is actively erasing
or programming. (This includes programming in the Erase
Suspend mode.) If the output is high (Ready), the device
is ready to read array data (including during the Erase
Suspend mode), or is in the standby mode.
Table 4 shows the outputs for RY/BY#.
Q6:Toggle BIT I
Toggle Bit I on Q6 indicates whether an Automatic Pro-
gram or Erase algorithm is in progress or complete, or
whether the device has entered the Erase Suspend mode.
Toggle Bit I may be read at any address, and is valid
after the rising edge of the final WE# or CE#, whichever
happens first, pulse in the command sequence (prior to
the program or erase operation), and during the sector
time-out.
During an Automatic Program or Erase algorithm opera-
tion, successive read cycles to any address cause Q6
to toggle. The system may use either OE# or CE# to
control the read cycles. When the operation is complete,
Q6 stops toggling.
After an erase command sequence is written, if all sec-
tors selected for erasing are protected, Q6 toggles and
returns to reading array data. If not all selected sectors
are protected, the Automatic Erase algorithm erases the
unprotected sectors, and ignores the selected sectors
that are protected.
The system can use Q6 and Q2 together to determine
whether a sector is actively erasing or is erase sus-
pended. When the device is actively erasing (that is, the
Automatic Erase algorithm is in progress), Q6 toggling.
When the device enters the Erase Suspend mode, Q6
stops toggling. However, the system must also use Q2
to determine which sectors are erasing or erase-sus-
pended. Alternatively, the system can use Q7.
If a program address falls within a protected sector, Q6
toggles for approximately 2 us after the program com-
mand sequence is written, then returns to reading array
data.
Q6 also toggles during the erase-suspend-program mode,
and stops toggling once the Automatic Program algorithm
is complete.
Table 4 shows the outputs for Toggle Bit I on Q6.
Q2:Toggle Bit II
The "Toggle Bit II" on Q2, when used with Q6, indicates
whether a particular sector is actively erasing (that is,
the Automatic Erase algorithm is in process), or whether
that sector is erase-suspended. Toggle Bit I is valid after
the rising edge of the final WE# or CE#, whichever hap-
pens first, pulse in the command sequence.
Q2 toggles when the system reads at addresses within
those sectors that have been selected for erasure. (The
system may use either OE# or CE# to control the read
cycles.) But Q2 cannot distinguish whether the sector
is actively erasing or is erase-suspended. Q6, by com-
parison, indicates whether the device is actively eras-
ing, or is in Erase Suspend, but cannot distinguish which
sectors are selected for erasure. Thus, both status bits
are required for sectors and mode information. Refer to
Table 4 to compare outputs for Q2 and Q6.
Reading Toggle Bits Q6/ Q2
Whenever the system initially begins reading toggle bit
status, it must read Q7-Q0 at least twice in a row to
determine whether a toggle bit is toggling. Typically, the
system would note and store the value of the toggle bit
after the first read. After the second read, the system
would compare the new value of the toggle bit with the
first. If the toggle bit is not toggling, the device has com-
pleted the program or erase operation. The system can
read array data on Q7-Q0 on the following read cycle.
However, if after the initial two read cycles, the system
determines that the toggle bit is still toggling, the sys-
tem also should note whether the value of Q5 is high
(see the section on Q5). If it is, the system should then
12
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
determine again whether the toggle bit is toggling, since
the toggle bit may have stopped toggling just as Q5 went
high. If the toggle bit is no longer toggling, the device
has successfully completed the program or erase opera-
tion. If it is still toggling, the device did not complete the
operation successfully, and the system must write the
reset command to return to reading array data.
The remaining scenario is that system initially determines
that the toggle bit is toggling and Q5 has not gone high.
The system may continue to monitor the toggle bit and
Q5 through successive read cycles, determining the sta-
tus as described in the previous paragraph. Alternatively,
it may choose to perform other system tasks. In this
case, the system must start at the beginning of the al-
gorithm when it returns to determine the status of the
operation.
Q5
Exceeded Timing Limits
Q5 will indicate if the program or erase time has exceeded
the specified limits (internal pulse count). Under these
conditions Q5 will produce a "1". This time-out condition
indicates that the program or erase cycle was not suc-
cessfully completed. Data# Polling and Toggle Bit are
the only operating functions of the device under this con-
dition.
If this time-out condition occurs during sector erase op-
eration, it specifies that a particular sector is bad and it
may not be reused. However, other sectors are still func-
tional and may be used for the program or erase opera-
tion. The device must be reset to use other sectors.
Write the Reset command sequence to the device, and
then execute program or erase command sequence. This
allows the system to continue to use the other active
sectors in the device.
If this time-out condition occurs during the chip erase
operation, it specifies that the entire chip is bad or com-
bination of sectors are bad.
If this time-out condition occurs during the byte program-
ming operation, it specifies that the entire sector con-
taining that byte is bad and this sector may not be re-
used, (other sectors are still functional and can be re-
used).
The time-out condition may also appear if a user tries to
program a non blank location without erasing. In this
case the device locks out and never completes the Au-
tomatic Algorithm operation. Hence, the system never
reads a valid data on Q7 bit and Q6 never stops toggling.
Once the Device has exceeded timing limits, the Q5 bit
will indicate a "1". Please note that this is not a device
failure condition since the device was incorrectly used.
DATA PROTECTION
The MX29F400C T/B is designed to offer protection
against accidental erasure or programming caused by
spurious system level signals that may exist during power
transition. During power up the device automatically re-
sets the state machine in the Read mode. In addition,
with its control register architecture, alteration of the
memory contents only occurs after successful comple-
tion of specific command sequences. The device also
incorporates several features to prevent inadvertent write
cycles resulting from VCC power-up and power-down tran-
sition or system noise.
TEMPORARY SECTOR UNPROTECT
This feature allows temporary unprotection of previously
protected sector to change data in-system. The Tempo-
rary Sector Unprotect mode is activated by setting the
RESET# pin to VID(11.5V-12.5V). During this mode, for-
merly protected sectors can be programmed or erased
as un-protected sector. Once VID is remove from the
RESET# pin, all the previously protected sectors are pro-
tected again.
Q3
Sector Erase Timer
After the completion of the initial sector erase command
sequence, the sector erase time-out will begin. Q3 will
remain low until the time-out is complete. Data# Polling
and Toggle Bit are valid after the initial sector erase com-
mand sequence.
If Data# Polling or the Toggle Bit indicates the device has
been written with a valid erase command, Q3 may be
used to determine if the sector erase timer window is
still open. If Q3 is high ("1") the internally controlled
erase cycle has begun; attempts to write subsequent
commands to the device will be ignored until the erase
13
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
operation is completed as indicated by Data# Polling or
Toggle Bit. If Q3 is low ("0"), the device will accept addi-
tional sector erase commands. To insure the command
has been accepted, the system software should check
the status of Q3 prior to and following each subsequent
sector erase command. If Q3 were high on the second
status check, the command may not have been accepted.
WRITE PULSE "GLITCH" PROTECTION
Noise pulses of less than 5ns(typical) on CE# or WE#
will not initiate a write cycle.
LOGICAL INHIBIT
Writing is inhibited by holding any one of OE# = VIL,
CE# = VIH or WE# = VIH. To initiate a write cycle CE#
and WE# must be a logical zero while OE# is a logical
one.
POWER SUPPLY DECOUPLING
In order to reduce power switching effect, each device
should have a 0.1uF ceramic capacitor connected be-
tween its VCC and GND.
14
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
TEMPORARY SECTOR UNPROTECT OPERATION
Start
RESET# = VID (Note 1)
Perform Erase or Program Operation
RESET# = VIH
Temporary Sector Unprotect Completed(Note 2)
Operation Completed
2. All previously protected sectors are protected again.
Notes : 1. All protected sectors are temporary unprotected.
VID=11.5V~12.5V
15
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
TEMPORARY SECTOR UNPROTECT
Parameter Std. Description
Test Setup
All Speed Options Unit
tVIDR
VID Rise and Fall Time (See Note)
Min
500
ns
tRSP
RESET# Setup Time for Temporary Sector Unprotect
Min
4
us
Note:
Not 100% tested
TEMPORARY SECTOR UNPROTECT TIMING DIAGRAM
RESET#
CE#
WE#
RY/BY#
tVIDR
tVIDR
Program or Erase Command Sequence
12V
0 or 5V
0 or 5V
tRSP
16
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
RESET# TIMING WAVEFORM
AC CHARACTERISTICS
Parameter Std
Description
Test Setup
All Speed Options Unit
tREADY1
RESET# PIN Low (During Automatic Algorithms)
MAX
20
us
to Read or Write (See Note)
tREADY2
RESET# PIN Low (NOT During Automatic
MAX
500
ns
Algorithms) to Read or Write (See Note)
tRP1
RESET# Pulse Width (During Automatic Algorithms)
MIN
10
us
tRP2
RESET# Pulse Width (NOT During Automatic Algorithms) MIN
500
ns
tRH
RESET# High Time Before Read(See Note)
MIN
0
ns
tRB1
RY/BY# Recovery Time(to CE#, OE# go low)
MIN
0
ns
tRB2
RY/BY# Recovery Time(to WE# go low)
MIN
50
ns
Note:Not 100% tested
tRH
tRB1
tRB2
tReady1
tRP2
tRP1
tReady2
RY/BY#
CE#, OE#
RESET#
Reset Timing NOT during Automatic Algorithms
Reset Timing during Automatic Algorithms
RY/BY#
CE#, OE#
RESET#
WE#
17
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
POWER-UP SEQUENCE
The MX29F400C T/B powers up in the Read only mode.
In addition, the memory contents may only be altered
after successful completion of the predefined command
sequences.
ABSOLUTE MAXIMUM RATINGS
RATING
VALUE
Ambient Operating Temperature
-40
o
C to 85
o
C (*)
Ambient Temperature with Power
-55
o
C to 125
o
C
Applied
Storage Temperature
-65
o
C to 125
o
C
Applied Input Voltage
-0.5V to 7.0V
Applied Output Voltage
-0.5V to 7.0V
VCC to Ground Potential
-0.5V to 7.0V
A9
-0.5V to 13.5V
NOTICE:
Stresses greater than those listed under ABSOLUTE MAXI-
MUM RATINGS may cause permanent damage to the de-
vice. This is a stress rating only and functional operational
sections of this specification is not implied. Exposure to ab-
solute maximum rating conditions for extended period may
affect reliability.
NOTICE:
Specifications contained within the following tables are sub-
ject to change.
* The automotive grade is under development.
SECTOR PROTECTION WITHOUT 12V SYS-
TEM
The MX29F400C T/B also feature a hardware sector
protection method in a system without 12V power supply.
The programming equipment do not need to supply 12
volts to protect sectors. The details are shown in sector
protect algorithm and waveform.
CHIP UNPROTECT WITHOUT 12V SYSTEM
The MX29F400C T/B also feature a hardware chip
unprotection method in a system without 12V power
supply. The programming equipment do not need to
supply 12 volts to unprotect all sectors. The details are
shown in chip unprotect algorithm and waveform.
18
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
CAPACITANCE TA = 25
o
C, f = 1.0 MHz
SYMBOL
PARAMETER
MIN.
TYP
MAX.
UNIT
CONDITIONS
CIN1
Input Capacitance
8
pF
VIN = 0V
CIN2
Control Pin Capacitance
12
pF
VIN = 0V
COUT
Output Capacitance
12
pF
VOUT = 0V
DC CHARACTERISTICS
TA = -40
o
C to 85
o
C, VCC = 5V


10%
SYMBOL PARAMETER
MIN.
TYP
MAX.
UNIT
CONDITIONS
ILI
Input Leakage Current
1
uA
VIN = GND to VCC
ILO
Output Leakage Current
10
uA
VOUT = GND to VCC
ISB1
Standby VCC current
1
mA
CE# = VIH
ISB2
1(Note3) 5(Note3)
uA
CE# = VCC
0.3V
ICC1
Operating VCC current
40
mA
IOUT = 0mA, f=5MHz
ICC2
50
mA
IOUT= 0mA, f=10MHz
VIL
Input Low Voltage
-0.3(NOTE 1)
0.8
V
VIH
Input High Voltage(NOTE 2)
0.7xVCC
VCC + 0.3
V
VOL
Output Low Voltage
0.45
V
IOL = 2.1mA, VCC= VCC MIN
VOH1
Output High Voltage(TTL)
2.4
V
IOH = -2mA, VCC= VCC MIN
VOH2
Output High Voltage(CMOS) VCC-0.4
V
IOH = -100uA,VCC=VCC MIN
NOTES:
1. VIL min. = -1.0V for pulse width is equal to or less than 50 ns.
VIL min. = -2.0V for pulse width is equal to or less than 20 ns.
2. VIH max. = VCC + 1.5V for pulse width is equal to or less than 20 ns
If VIH is over the specified maximum value, read operation cannot be guaranteed.
3. ISB2 20uA max. for Automotive grade. Which is under development.
READ OPERATION
19
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AC CHARACTERISTICS
TA = -40
o
C to 85
o
C, VCC = 5V
10%
Notes:
1. tDF is defined as the time at which the output achieves
the open circuit condition and data is no longer driven.
2. Automotive grade is under development.
29F400C-55
29F400C-70
29F400C-90
SYMBOL PARAMETER
MIN.
MAX.
MIN.
MAX.
MIN. MAX.
UNIT
Conditions
tACC
Address to Output Delay
55
70
90
ns
CE#=OE#=VIL
tCE
CE# to Output Delay
55
70
90
ns
OE#=VIL
tOE
OE# to Output Delay
30
30
35
ns
CE#=VIL
tDF
OE# High to Output Float
0
20
0
20
0
20
ns
CE#=VIL
(Note 1)
tOH
Address to Output hold
0
0
0
ns
CE#=OE#=VIL
TEST CONDITIONS:
Input pulse levels: 0.45V/0.7xVCC for 70ns & 90ns,
0V/0.7xVCC for 55ns
Input rise and fall times: is equal to or less than 10ns
for 70ns & 90ns, 5ns for 55ns
Output load: 1 TTL gate + 100pF (Including scope and
jig) for 70ns & 90ns, 1TTLgate+30pF for 55ns max.
Reference levels for measuring timing: 0.8V, 2.0V for
70ns & 90ns,1.5V for 55ns
20
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
READ TIMING WAVEFORMS
COMMAND PROGRAMMING/DATA PROGRAMMING/ERASE OPERATION
Notes:
1. VIL min. = -0.6V for pulse width is equal to or less than 20ns.
2. If VIH is over the specified maximum value, programming operation cannot be guaranteed.
3. ICCES is specified with the device de-selected. If the device is read during erase suspend mode, current draw is
the sum of ICCES and ICC1 or ICC2.
4. All current are in RMS unless otherwise noted.
5. The Automotive grade is under development.
DC CHARACTERISTICS
TA = -40
o
C to 85
o
C, VCC = 5V


10%
SYMBOL
PARAMETER
MIN.
TYP
MAX.
UNIT
CONDITIONS
ICC1 (Read)
Operating VCC Current
40
mA
IOUT=0mA, f=5MHz
ICC2
50
mA
IOUT=0mA, f=10MHz
ICC3 (Program)
50
mA
In Programming
ICC4 (Erase)
50
mA
In Erase
ICCES
VCC Erase Suspend Current
2
mA
CE#=VIH, Erase Suspended
Addresses
CE#
OE#
tACC
WE#
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
VOH
VOL
HIGH Z
HIGH Z
DATA Valid
tOE
tDF
tCE
Outputs
tOH
ADD Valid
21
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AC CHARACTERISTICS TA = -40
o
C to 85
o
C, VCC = 5V


10%
Speed Option
SYMBOL
PARAMETER
55(Note 2)
70
90
UNIT
tOES
OE# setup time
MIN.
0
0
0
ns
tCWC
Command programming cycle
MIN.
55
70
90
ns
tCEP
WE# programming pulse width
MIN.
35
35
45
ns
tCEPH
WE# programming pulse width High
MIN.
20
20
20
ns
tAS
Address setup time
MIN.
0
0
0
ns
tAH
Address hold time
MIN.
45
45
45
ns
tDS
Data setup time
MIN.
30
30
45
ns
tDH
Data hold time
MIN.
0
0
0
ns
tCESC
CE# setup time before command write
MIN.
0
0
0
ns
tDF
Output disable time (Note 1)
MAX.
20
20
20
ns
tAETC
Erase time in auto chip erase
TYP.
4
4
4
s
MAX.
32
32
32
s
tAETB
Erase time in auto sector erase
TYP.
0.7
0.7
0.7
s
MAX.
15
15
15
s
tAVT
Programming time in auto verify
TYP.
9/11
9/11
9/11
us
(byte/ word program time)
MAX.
300/360
300/360
300/360
us
tBAL
Sector address load time
MIN.
50
50
50
us
tCH
CE# Hold Time
MIN.
0
0
0
ns
tCS
CE# setup to WE# going low
MIN.
0
0
0
ns
Notes:
1. tDF defined as the time at which the output achieves the open circuit condition and data is no longer driven.
2. Under condition of VCC=5V
10%,CL=30pF,VIH/VIL=0.7xVCC/0V,VOH/VOL=1.5V/1.5V,IOL=2mA,IOH=2mA.
22
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
SWITCHING TEST CIRCUITS
SWITCHING TEST WAVEFORMS for 29F400C T/B-70 and 29F400C T/B-90
SWITCHING TEST WAVEFORMS for 29F400C T/B-55
DEVICE UNDER
TEST
DIODES=IN3064
OR EQUIVALENT
CL
6.2K ohm
2.7K ohm
+5V
CL=100pF Including jig capacitance for 70ns and 90ns
CL=30pF Including jig capacitance for 55ns
2.0V
2.0V
0.8V
0.8V
TEST POINTS
0.7xVCC
0.45V
AC TESTING: Inputs are driven at 0.7xVCC for a logic "1" and 0.45V for a logic "0".
Input pulse rise and fall times are < 10ns.
OUTPUT
INPUT
1.5V
1.5V
TEST POINTS
0.7xVCC
0V
AC TESTING: Inputs are driven at 0.7xVCC for a logic "1" and 0V for a logic "0".
Input pulse rise and fall times are < 5ns.
OUTPUT
INPUT
23
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
COMMAND WRITE TIMING WAVEFORM
Addresses
CE#
OE#
WE#
DIN
tDS
tAH
Data
tDH
tCS
tCH
tCWC
tCEPH1
tCEP
tOES
tAS
VCC
5V
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
ADD Valid
24
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC PROGRAMMING TIMING WAVEFORM (WORD MODE)
AUTOMATIC PROGRAMMING TIMING WAVEFORM
One byte data is programmed. Verify in fast algorithm
and additional programming by external control are not
required because these operations are executed auto-
matically by internal control circuit. Programming comple-
tion can be verified by Data# Polling and toggle bit check-
ing after automatic verification starts. Device outputs
DATA# during programming and DATA# after programming
on Q7.(Q6 is for toggle bit; see toggle bit, Data# Polling,
timing waveform)
tCWC
tAS
tCEP
tDS
tDH
tDF
Vcc 5V
CE#
OE#
Q0,Q1,Q2
Q4(Note 1)
WE#
A11~A17
tCEPH
tAH
ADD Valid
tCESC
Q7
Command In
ADD Valid
A0~A10
Command In
Command In
Data In
DATA
Command In
Command In
Command In
Data In
DATA
DATA#
tAVT
tOE
Data# Polling
2AAH
555H
555H
(Q0~Q7)
Command #55H
Command #A0H
Note :
(1). Q6:Toggle bit, Q5:Timing-limit bit, Q3: Time-out bit
Command #AAH
25
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC PROGRAMMING ALGORITHM FLOWCHART (WORD MODE)
START
Write Data AAH Address 555H
Write Data 55H Address 2AAH
Write Program Data/Address
Write Data A0H Address 555H
YES
NO
Toggle Bit Checking
Q6 not Toggled
Verify Word Ok
YES
Q5 = 1
Reset
Auto Program Completed
Auto Program Exceed
Timing Limit
NO
Invalid
Command
YES
NO
.
26
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
All data in chip are erased. External erase verification is
not required because data is erased automatically by
internal control circuit. Erasure completion can be veri-
fied by Data# Polling and toggle bit checking after auto-
AUTOMATIC CHIP ERASE TIMING WAVEFORM (WORD MODE)
AUTOMATIC CHIP ERASE TIMING WAVEFORM
matic erase starts. Device outputs 0 during erasure
and 1 after erasure on Q7.(Q6 is for toggle bit; see toggle
bit, Data# Polling, timing waveform)
tCWC
tAS
tCEP
tDS tDH
Vcc 5V
CE#
OE#
Q0,Q1,
Q4(Note 1)
WE#
A11~A17
tCEPH
tAH
Q7
Command In
A0~A10
Command In
Command In
Command In
Command In
Command In
tAETC
Data# Polling
2AAH
555H
555H
Command #AAH
Command #55H
Command #80H
(Q0~Q7)
Notes:
(1). Q6:Toggle bit, Q5:Timing-limit bit, Q3: Time-out bit, Q2: Toggle bit
555H
2AAH
555H
Command In
Command In
Command #AAH
Command In
Command In
Command #55H
Command In
Command In
Command #10H
27
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC CHIP ERASE ALGORITHM FLOWCHART (WORD MODE)
START
Write Data AAH Address 555H
Write Data 55H Address 2AAH
Write Data AAH Address 555H
Write Data 80H Address 555H
YES
NO
Toggle Bit Checking
Q6 not Toggled
Write Data 10H Address 555H
Write Data 55H Address 2AAH
Reset
Auto Chip Erase Exceed
Timing Limit
DATA# Polling
Q7 = 1
YES
Q5 = 1
Auto Chip Erase Completed
NO
YES
NO
Invalid
Command
28
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC SECTOR ERASE TIMING WAVEFORM (WORD MODE)
Sector data indicated by A12 to A17 are erased. Exter-
nal erase verify is not required because data are erased
automatically by internal control circuit. Erasure comple-
tion can be verified by Data# Polling and toggle bit check-
AUTOMATIC SECTOR ERASE TIMING WAVEFORM
ing after automatic erase starts. Device outputs 0 dur-
ing erasure and 1 after erasure on Q7.(Q6 is for toggle
bit; see toggle bit, Data# Polling, timing waveform)
tAH
Sector
Address0
555H
2AAH
2AAH
555H
555H
Sector
Address1
Sector
Addressn
VCC 5V
CE#
OE#
Q0,Q1,
Q4(Note 1)
WE#
A12~A17
Q7
A0~A10
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command
In
Command #30H
Command #30H
Command #30H
Command #55H
Command #AAH
Command #80H
Command #55H
Command #AAH
(Q0~Q7)
Command
In
Command
In
tDH
tDS
tCEP
tCWC
tAETB
tBAL
Data# Polling
tCEPH
tAS
Note:
(1). Q6:Toggle bit, Q5:Timing-limit bit, Q3: Time-out bit, Q2: Toggle bit
29
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
AUTOMATIC SECTOR ERASE ALGORITHM FLOWCHART (WORD MODE)
START
Write Data AAH Address 555H
Write Data 55H Address 2AAH
Write Data AAH Address 555H
Write Data 80H Address 555H
YES
YES
NO
NO
Toggle Bit Checking
Q6 not Toggled
Write Data 30H Sector Address
Write Data 55H Address 2AAH
Reset
Auto Block Erase Exceed
Timing Limit
Data# Polling
Q7 = 1
Q5 = 1
Auto Block Erase Completed
Load Other Sector Addrss If Necessary
(Load Other Sector Address)
YES
NO
Last Block
to Erase
Time-out Bit
Checking Q3=1 ?
Toggle Bit Checking
Q6 Toggled ?
Invalid Command
NO
YES
YES
NO
30
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
ERASE SUSPEND/ERASE RESUME FLOWCHART
Note: If the system implements an endless erase suspend/resume loop, or the number of erase suspend/resume is
exceeded 1024 times, then the 400us time delay must be put into consideration.
START
Write Data B0H
Toggle Bit checking Q6
not toggled
ERASE SUSPEND
YES
NO
Write Data 30H
Delay 400us (note)
Continue Erase
Reading or
Programming End
Read Array or
Program
Another
Erase Suspend ?
NO
YES
YES
NO
ERASE RESUME
31
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
TIMING WAVEFORM FOR SECTOR PROTECTION FOR SYSTEM WITHOUT 12V
tOE
Data
OE#
WE#
CE#
A1
A6
* See the following Note!
Verify
01H
A18-A16
Sector Address
5V
Note1: Must issue "unlock for sector protect/unprotect" command before sector protection
for a system without 12V provided.
Note2: Except F0H
Toggle bit polling
Don't care
(Note 2)
tCEP
F0H
32
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
TIMING WAVEFORM FOR CHIP UNPROTECTION FOR SYSTEM WITHOUT 12V
tOE
Data
WE#
CE#
A1
Verify
00H
A6
Note1: Must issue "unlock for sector protect/unprotect" command before sector unprotection
for a system without 12V provided.
OE#
tCEP
5V
Toggle bit polling
Don't care
(Note 2)
* See the following Note!
F0H
Note2: Except F0H
33
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
SECTOR PROTECTION ALGORITHM FOR SYSTEM WITHOUT 12V
START
Set Up Sector Addr
(A17,A16,A15,A14,A13,A12)
PLSCNT=1
Sector Protection
Complete
Data=01H?
Yes
Yes
OE#=VIH,A9=VIH
CE#=VIL,A6=VIL
Activate WE# Pulse to start
Data don't care
Set CE#=OE#=VIL
A9=VIH
Read from Sector
Addr=SA, A1=1
Protect Another
Sector?
Write Reset Command
Device Failed
PLSCNT=32?
Yes
No
No
Increment PLSCNT
No
Write "unlock for sector protect/unprotect"
Command(Table1)
Toggle bit checking
Q6 not Toggled
No
Yes
34
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
CHIP UNPROTECTION ALGORITHM FOR SYSTEM WITHOUT 12V
START
Protect All Sectors
PLSCNT=1
Chip Unprotect
Complete
Data=00H?
Yes
Set OE#=A9=VIH
CE#=VIL,A6=1
Activate WE# Pulse to start
Data don't care
Set OE#=CE#=VIL
A9=VIH,A1=1
Set Up First Sector Addr
All sectors have
been verified?
Write Reset Command
Device Failed
PLSCNT=1000?
No
Increment
PLSCNT
No
Read Data from Device
Yes
Yes
No
Increment
Sector Addr
* It is recommended before unprotect whole chip, all sectors should be protected in advance.
Write "unlock for sector protect/unprotect"
Command (Table 1)
Toggle bit checking
Q6 not Toggled
Yes
No
35
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
ID CODE READ TIMING WAVEFORM
tACC
tCE
tACC
tOE
tOH
tOH
tDF
DATA OUT
C2H/00C2H
23H/ABH (Byte)
2223H/22ABH (Word)
VID
VIH
VIL
ADD
A9
ADD
A1-A8
A10-A17
CE#
OE#
WE#
ADD
A0
DATA OUT
DATA
Q0-Q15
VCC
5V
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
VIH
VIL
36
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
MIN.
MAX.
Input Voltage with respect to GND on all pins except I/O pins
-1.0V
13.5V
Input Voltage with respect to GND on all I/O pins
-1.0V
Vcc + 1.0V
Current
-100mA
+100mA
Includes all pins except Vcc. Test conditions: Vcc = 5.0V, one pin at a time.
LATCH-UP CHARACTERISTICS
ERASE AND PROGRAMMING PERFORMANCE(1)
Note:
1.Not 100% Tested, Excludes external system level over head.
2.Typical values measured at 25
C,5V.
3.Maximum values measured at 25
C,4.5V.
PARAMETER
MIN.
UNIT
Data Retention Time
20
Years
DATA RETENTION
LIMITS
PARAMETER
MIN.
TYP.(2)
MAX.(3)
UNITS
Sector Erase Time
0.7
15
sec
Chip Erase Time
4
32
sec
Byte Programming Time
9
300
us
Word Programming Time
11
360
us
Chip Programming Time
Byte Mode
4.5
13.5
sec
Word Mode
3
9
sec
Erase/Program Cycles
100,000
Cycles
37
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
ORDERING INFORMATION
PART NO.
Access Time Operating Current Standby Current Temperature
PACKAGE
Remark
(ns)
MAX.(mA)
MAX.(uA)
Range
MX29F400CTMI-55
55
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CTMI-70
70
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CTMI-90
90
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CTTI-55
55
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CTTI-70
70
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CTTI-90
90
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CBMI-55
55
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CBMI-70
70
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CBMI-90
90
40
5
-40
o
C~85
o
C
44 Pin SOP
MX29F400CBTI-55
55
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CBTI-70
70
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CBTI-90
90
40
5
-40
o
C~85
o
C
48 Pin TSOP
(Normal Type)
MX29F400CTMI-55G
55
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CTMI-70G
70
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CTMI-90G
90
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CTTI-55G
55
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
MX29F400CTTI-70G
70
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
MX29F400CTTI-90G
90
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
MX29F400CBMI-55G
55
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CBMI-70G
70
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CBMI-90G
90
40
5
-40
o
C~85
o
C
44 Pin SOP
PB-free
MX29F400CBTI-55G
55
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
MX29F400CBTI-70G
70
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
MX29F400CBTI-90G
90
40
5
-40
o
C~85
o
C
48 Pin TSOP PB-free
(Normal Type)
Note: The Automotive grade is under development.
38
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
PART NAME DESCRIPTION
MX
29
F
70
C
T T
I
G
OPTION:
G: Lead-free package
blank: normal
SPEED:
55:55ns
70:70ns
90: 90ns
TEMPERATURE RANGE:
I: Industrial (-40aC to 85 C)
PACKAGE:
M:SOP
T: TSOP
BOOT BLOCK TYPE:
T: Top Boot
B: Bottom Boot
REVISION:
C
DENSITY & MODE:
400: 4M, x8/x16 Boot Sector
TYPE:
F: 5V
DEVICE:
29: Flash
400
39
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
PACKAGE INFORMATION
40
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
41
P/N:PM1200
MX29F400C T/B
REV. 1.0, DEC. 20, 2005
REVISION HISTORY
Revision No. Description
Page
Date
1.0
1. Removed "Preliminary" title
P1
DEC/20/2005
2. Removed commercial grade
All
3. Added access time: 55ns; Removed access time: 120ns
All
MX29F400C T/B
M
ACRONIX
I
NTERNATIONAL
C
O.,
L
TD.
Headquarters:
TEL:+886-3-578-6688
FAX:+886-3-563-2888
Europe Office :
TEL:+32-2-456-8020
FAX:+32-2-456-8021
Hong Kong Office :
TEL:+86-755-834-335-79
FAX:+86-755-834-380-78
Japan Office :
Kawasaki Office :
TEL:+81-44-246-9100
FAX:+81-44-246-9105
Osaka Office :
TEL:+81-6-4807-5460
FAX:+81-6-4807-5461
Singapore Office :
TEL:+65-6346-5505
FAX:+65-6348-8096
Taipei Office :
TEL:+886-2-2509-3300
FAX:+886-2-2509-2200
M
ACRONIX
A
MERICA,
I
NC.
TEL:+1-408-262-8887
FAX:+1-408-262-8810
http : //www.macronix.com
MACRONIX INTERNATIONAL CO., LTD. reserves the right to change product and specifications without notice.