Features and Benefits
0 1.0 Bar Range
Differential pressure sensor
Compact Design
High Long Term Stability
Low Cost
Applications
Medical Instrumentation (Blood Pressure)
Consumer Appliances
Sports Equipment
Pressure Difference and Flow Monitoring
Ordering Information
Part No.
Temperature Suffix
Package Code
MLX90210
C (-0C to 70C)
UD (Goldbumped Die on Wafer, unsawn)
Functional Diagram
Description
The MLX90210 is a discrete micromachined
Pressure sensor IC suitable for pressure ranges
Between 0 to 1.0 Bar. The pressure medium
must be dry and non-corrosive, such as air.
The circuit is a piezoresistive bridge which is
realized in silicon through a special
micromachining process. As pressure is applied
to the bridge, a differential voltage change is
seen across the V
out
pins, while a bias voltage is
applied to the V
exc
pins.
The MLX90210 is a versatile pressure sensor
solution which can be directly interfaced with
other Melexis ICs such as the MLX90308, which
provides amplification, signal conditioning as
well as the bias current to supply the sensor
itself.

MLX90210
Pressure Sensor IC
3901090210 Pressure sensor IC
Page 2
Rev 002
MLX90210 Electrical Specifications
DC Operating Parameters T
A
= 25C, V
DD
= 5V (note 3), Pressure = 1.0 Bar full scale.
Parameter
Symbol
Min
Typ
Max
Units
Excitation voltage
0
5
12
V
Zero Pressure Offset
V
OFF
-20
0
+20
m
V
Sensitivity
S
15
30
45
m
V/V/bar
TC of the Sensitivity
TC
S
-0.17 -0.21 -0.26 %/C
Bridge Resistance
R
BR
360
400
450
Ohm
Burst Pressure
2
Bar
Operating Temp
0
70
C
Storage Temp (2)
-55
150
C
MLX90210 Mechanical Dimensions (4)

Membrane Size

0.81mm x 0.81mm

Chip Thickness

0.61mm

Chip Size

1.90mm x 1.90mm

Notes:
1)
Temperature range refers to operation and deposit in an inert environment
2)
Temperature range refers to operation and deposit in an inert environment
3)
To prevent measurement errors, measure above 3V V
DD
in impulse mode
4)
Tolerance of 10% unless otherwise specified.
MLX90210
Pressure Sensor IC
3901090210 Pressure sensor IC
Page 3
Rev 002
Reliability Information
Melexis devices are classified and qualified regarding suitability for infrared, vapor phase and wave
soldering with usual (63/37 SnPb-) solder (melting point at 183degC).
The following test methods are applied:

IPC/JEDEC J-STD-020A (issue April 1999)
Moisture/Reflow Sensitivity Classification For Nonhermetic Solid State Surface Mount Devices
CECC00802 (issue 1994)
Standard Method For The Specification of Surface Mounting Components (SMDs) of Assessed Quality
MIL 883 Method 2003 / JEDEC-STD-22 Test Method B102
Solderability

For all soldering technologies deviating from above mentioned standard conditions (regarding peak
temperature, temperature gradient, temperature profile etc) additional classification and qualification tests
have to be agreed upon with Melexis.

The application of Wave Soldering for SMD's is allowed only after consulting Melexis regarding assurance
of adhesive strength between device and board.

For more information on manufacturability/solderability see quality page at our website:
http://www.melexis.com/






MLX90210
Pressure Sensor IC
3901090210 Pressure sensor IC
Page 4
Rev 002
Disclaimer

Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in
its Term of Sale. Melexis makes no warranty, express, statutory, implied, or by description regarding the
information set forth herein or regarding the freedom of the described devices from patent infringement.
Melexis reserves the right to change specifications and prices at any time and without notice. Therefore,
prior to designing this product into a system, it is necessary to check with Melexis for current information.
This product is intended for use in normal commercial applications. Applications requiring extended
temperature range, unusual environmental requirements, or high reliability applications, such as military,
medical life-support or life-sustaining equipment are specifically not recommended without additional
processing by Melexis for each application.
The information furnished by Melexis is believed to be correct and accurate. However, Melexis shall not
be liable to recipient or any third party for any damages, including but not limited to personal injury,
property damage, loss of profits, loss of use, interrupt of business or indirect, special incidental or
consequential damages, of any kind, in connection with or arising out of the furnishing, performance or
use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow
out of Melexis' rendering of technical or other services.
2002 Melexis NV. All rights reserved.
For the latest version of this document, go to our website at:
www.melexis.com
Or for additional information contact Melexis Direct:
Europe and Japan:
All other locations:
Phone: +32 13 67 04 95
Phone: +1 603 223 2362
E-mail: sales_europe@melexis.com
E-mail: sales_usa@melexis.com




QS9000, VDA6.1 and ISO14001 Certified