ChipFind - документация

Электронный компонент: 53255

Скачать:  PDF   ZIP
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION
905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281
www.micropac.com
E-MAIL:
hybridsales@micropac.com
05/16/01
53255
400VDC 10A SOLID STATE RELAY
Mii
HYBRID MICROELECTRONICS
PRODUCTS DIVISION
Features:
Hermetically Sealed Package
10A Continuous Output Current
Optically
Coupled
Input/Output Isolation Tested to 1000 VDC
Shock and Vibration Resistant
Applications:
Power
Distribution/Switching
Solenoid
Driver
Stepper Motor Driver
Switching
Heaters
DESCRIPTION
The 53255 is a DC solid state relay (SSR) designed for high reliability commercial applications. This light weight
device is resistant to damage from severe shock and vibration, and is immune to contact related problems inherent
in electro-mechanical relays. The SSR is enclosed in a hermetic metal package to ensure reliability in harsh
environments. Effective isolation of 1000 VDC between control and load circuits is achieved through the use of
optical coupling.
Functionally, the device operates as a single-pole single-throw, normally open (1 Form A) DC solid-state relay. The
SSR is actuated by an input current of 5 to 15 mA, which can be supplied from standard logic types such as open-
collector TTL. Output is provided by a power MOSFET capable of carrying a continuous current of 10 amperes.
ABSOLUTE MAXIMUM RATINGS
Output Voltage ..................................................................................................................................................... 450 VDC
Continuous Output current ..........................................................................................................................................10 A
Peak Output Current
(1)
........................................................................................................................................20 A
Storage Temperature Range .................................................................................................................. -65C to +150C
Operating Junction Temperature............................................................................................................ -55C to +150C
Lead Solder Temperature for 10 seconds .............................................................................................................. 300C
Continuous Input Current .........................................................................................................................................25 mA
Peak Input Current
(2)
............................................................................................................................................ 100 mA
Reverse Input Voltage............................................................................................................................................. 6 VDC
WEIGHT: .........................................................................................................................................17 grams (typical)
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION
905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281
www.micropac.com
E-MAIL:
hybridsales@micropac.com
05/16/01
53255
400VDC 10A Solid State Relay
RECOMMENDED OPERATING CONDITIONS:
Parameter
Symbol
Min.
Max.
Units
Output Voltage
V
O (OFF)
400
VDC
Continuous Output Current
I
O (ON)
10
A
Input Current (on)
I
F (ON)
5
15
mA
Input Voltage (off)
V
F (OFF)
0
1
VDC
Operating Case Temperature
T
C
-40
85
C
ELECTRICAL SPECIFICATIONS
T
C
= -40C to +85C unless otherwise specified
Parameter
Sym.
Min.
Typ.*
Max.
Unit
s
Test Conditions
Notes
Output On-Resistance
R
(ON)
.14
.27
I
F
= 15 mA
I
O
= 1 A
Output Leakage Current
I
O (OFF)
250
A
V
F
= 1 VDC
V
O
= 450 VDC
Input Forward Voltage
V
F
3.75
4.20
VDC
I
F
= 15 mA
Input Reverse Breakdown Voltage
V
R
6
40
VDC
I
R
= 10
A
Input-Output Leakage
I
I-O
1
A
RH
45%, t = 5 s
V
I-O
= 1000 VDC
T
C
= 25C
4, 5
Turn-On Time
t
ON
3.3
8.0
ms
Turn-Off time
t
OFF
0.35
3
ms
Rise Time
t
R
2.5
6.0
ms
Fall Time
t
F
.19
2.0
ms
I
F
= 15 mA
I
O
= 1 A
V load = 40 VDC
Pulse width = 10 ms
Duty cycle
1%
6
Thermal Resistance (junction-case)
JC
1.8
C/W
* All typical values are at T
C
= 25C
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION
905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281
www.micropac.com
E-MAIL:
hybridsales@micropac.com
05/16/01
53255
400VDC - 10A Solid State Relay
Notes:
1. Non-repetitive, pulse width
10ms, T
C
= 25C.
2. Non-repetitive,
pulse
width
100s, T
C
= 25C.
3. Case Temperature T
C
= 25C.
4. Input pins shorted together and output pins shorted together.
5. Input-output potential applied momentarily, not an operating condition.
6. Rise time is measured from 10% to 90% of load current (90% to 10% of V
O
). Fall time is measured from 90% to
10% of load current (10% to 90% of V
O
).
CAUTION:
Care should be taken so as not to exceed the maximum power dissipation and maximum junction temperature
when repetitively switching loads.
INPUT
OUTPUT
ON
ON
OFF
OFF
Figure 1. Truth Table
Figure 1. Terminal Connections
R
LOAD
+V
C
-V
C
+DC SUPPLY
OUTPUT GND
TOP VIEW
R
S
Figure 2. Terminal Connections
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. HYBRID MICROELECTRONICS PRODUCTS DIVISION
905 E. Walnut St., Garland, TX 75040 (972) 272-3571 Fax (972) 494-2281
www.micropac.com
E-MAIL:
hybridsales@micropac.com
05/16/01
53255
400VDC - 10A Solid State Relay
Dimensions: inches
1.000
1.870 MAX
1.000
0.120
0.040 DIA, 6 PL
0.312
0.760
1.520
CL
0.275 MAX
0.500
0.125, TYP 5 PLACES
TOLERANCES NON-ACCUM
0.050
0.212
0.156 DIA
THRU 2 PL
0.170 R
2 PL
L
C
45
4 PL
Pin
Function
1
+IN
2
-IN
3
+OUT
4
+OUT
5
-OUT
6
-OUT
Notes: 1. For +OUT and -OUT functions, both pins must be used to meet the rated current.
2. ESD symbol (
) indicates pin 1.
Figure 3. Case Outline