Электронный компонент: MSSW003

Скачать:  PDF   ZIP
MOSEL VITELIC
(1/17)
(PID 249** 04/96)
MSSW003
14" Talking Clock/Watch
April 1996
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MOSEL VITELIC INC.
Features
Single power can operate at 3.0V or 4.5V (LCD
dependent)
3 1/2 gidits LCD display with 5 information flags,
in 1/2 duty 1/2 bias.
They are colon, PM, CHM, ALM, AL.
4 operation modes and easily operating :
Regular mode, current time adjust mode, Alarm
time adjust mode, Chime on/off & alarm on/off
mode.
The voice content is stored up to 14.5 seconds
at 6 KHz (15400h) and can be separated up to
64 sections.
The length of each section can be different and
is multiples of 100h.
The length of a section with mute could be up to
8000h.
Report current time by each TALK key trigger,
except in Alarm mode.
Current time display at regular mode.
Set alarm function on/off by setting ALM flag
on/off.
Report Alarm on/off status and display.
Report Chime on/off status and display.
Setting current time the dsiplay in flashing.
Alarm time will report at every setting.
Report Alarm sound with time when alarm time
is due.
General Description
The Mosel SW003 is a monolithic CMOS LSI intelligent chip that is dedicated for clock/watch application with
time announcing & alarm warning. 10 sentences are built-in for report and adjusting time and alarm. 3 1/2
digits LCD with 3 information flags are interfaced. With Mosel Editing system, every human language can be
defined by user when manuafacturing.
Setting alarm time in hour and minute.
PM flag displayed at 12 HR format after 12:00.
12/24 HR format selectable by pressing HOUR
key when in regular mode.
Two independent chime sentence groups for 12
& 24 HR chime modes. A group has 24 chime
sentences for 24 HR chime mode. The other
group has 12 sentences.
Based on the 32768 Hz quartz crystal.
Current output can drive 8 ohm speaker with a
transistor. Vout can drive buzzer directly.
Hour and minute digit adjustable individually by
pressing HR and MN key and can be repeat in
fast mode.
Time rolling reading in 1 Hz flash on two colon
dots.
Automatic ramp up and ramp down.
Power on reset automatically.
Automatic power down.
Reset to regular mode when in other mode
without any key input for 20 - 40 seconds.
Voice output frequency can be tuned by external
resistor.
Mosel standard codes are available.
MSM9203 demo board (COB) is provided.
Pages 9, 10, 11, 14 through 17 are provided herein. Pages 1 through 8 and 12, 13 are provided by file in DOS
format per request.
Taiwan
#1, Creation Road I,
Science - based Industrial Park,
Hsinchu, 30077
Taiwan, ROC
"taylor_hsiao@ccmail.mosel.com.tw"
TEL: 886-3-5770055
FAX: 886-3-5772788
FAX: 886-3-5784732
Taipei
7F, #102 Sec. 3,
Ming Chung E. Road,
Taipei,105
Taiwan, ROC
TEL: 886-2-5451213
FAX: 886-2-5451214
Hongkong
#19 Dai Fu Street,
Taipo Industrial Estate,
Taipo, N.T.
Hongkong
TEL: 852-2388-8277(MKO)
TEL: 852-2665-4883
FAX: 852-2664-2406
FAX: 852-2770-8011(MKO)
U.S.A.
#3910 North First Street,
San Jose,
CA. 65134-1501
U.S.A.
TEL: 1-408-433-6000
FAX: 1-408-433-0952
9/17
PID249** 04/96
MSSW003
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MOSEL-VITELIC
INC @ 1996
MSM9203-
V1M1 SN:
HOUR
MIN
TALK
MODE
E C B
VDD
GND
BZ
SPK
1 2
6
11
15 16
COM2
PM/AL
G2/A2
COM1
CHM/ALM
C3/B3
0
2 cm
1
COB Informations
Legend
Copper pad for X'tal
Copper pad for LCD
Copper pad for LCD
Through hole
Alignment hole
Standing hole
8050
X'tal
32.768 KHz
MOSEL VITELIC INC.
Preliminary
10/17
PID249** 04/96
MSSW003
Specifications subject to change without notice, contact your sales representatives for the most recent information.
Current
Talk
Voice
MN key
Voice
2412 (HR)
Hour Format
Talk
Voice
Talk
Voice
Talk
Voice
Talk
Voice
HR key
Voice
CHM (HR)
Voice
ALM (MN)
Voice
Mode key
Status
Voice
IV.b. MN key in mode 4 (initial state is OFF)
IV.a. MN Key in mode 2,3
III.c. HR key in mode 4 (initial state is OFF)
III.b. HR key in mode 2,3
III.a. HR key in mode 1
II.a. Talk key in mode 1,2,4
II.d. Talk key in mode 3
II.c. Long Talk key in mode 1,2,4
II.b. Several Talk keys in mode 1,2,4
V.a. Talk at Alarm : (condition : Alarm time = 11:30, Alarm ON, Chime ON or OFF)
I. Mode key operation, selecting modes
Timing Diagrams
Preliminary
MOSEL VITELIC INC.
Mode 1
Mode 2
Mode 3
Mode 4
Mode 1
Sentence 10
Sentence 10
Sentence 10
Sentence 10
Sentence 1
Sentence 1
Sent. 1
Sent. 1
Sentence 1
Alarm (C4)
Alarm (C4)
Sentence 3
12 hr.
24 Hr.
12 Hr.
24 Hr.
12 Hr.
Sent. 4
Sent.4
Sent. 4
Sent. 4
Sent. 4
Sent. 4
ON (sent. 9)
OFF (sent. 8)
ON (sent. 9)
Sent.5
Sent.5
Sent.5
Sent.5
Sent.5
Sent.5
ON (sent.7)
OFF (sent.6)
ON (sent.7)
11:29
11:30
11:31
Sentence 2
Sent. 2
Sentence 1
11/17
PID249** 04/96
MSSW003
Specifications subject to change without notice, contact your sales representatives for the most recent information.
4
5
6
7
8
9
10
3
2
1
30
29
28
27
26
25
24
23
22
21
19
18
17
11
14 15 16
13
12
20
E4/F4
C3/B3
G3/A3D3
E3/F3
D4/COL
C1/ADEG1
D2/B1
E2/F2
G2/A2
C2/B2
G4/A4
C4/B4
CHM/ALM
COM1
COM1
CHM/ALM
PM/AL
COM2
COM2
VEE
C1
X2
X1
COUT
VDD
V2
V1
T1
HOUR
HOUR
MIN
VSS
D1
R1
TALK
MODE
Rosc
VSS
VDD
VSS
VSS
MSSW003
L
C
D
M
O
D
U
L
E
32768Hz
R2
Buzzer
The number referred is pad number.
Current time
Voice
Current time
Key
Voice
Current time
Voice
Current time
Talk key
Voice
Current time
Key
Voice
V.b. Alarm function (conditions as V.a.)
V.c. Key (mode or HR or MN) at Alarm (conditions as V.a.)
VI.a. Chime function : (conditions : Alarm OFF, Chime ON)
VI.b. Talk at Chime (conditions as VI.a)
VI.c. Key (Mode or HR or MN) at Chime (conditions as VI.a)
Application Circuits
+
11:29
11:30
11:31
Sentence 2
Sentence 2
Sentence 2
11:29
11:30
11:31
Sentence 2
Sent. 2
XX:59
XY:00
XY:01
XY:01
XY:00
XX:59
XX:59
XY:00
XY:01
Sentence 1
Sentence 1
Sent. 1
Sentence 1
Preliminary
MOSEL VITELIC INC.
Product Request Form A : Voice Word Definitions : There are
words defined.
1<
<64
MSSW003
Specifications is subject to change without notice, contact your sales representatives for the most recent information
14/17
PID249** 04/96
T I T L E
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
Length summ. of above 64 words
must be < 15400h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
Voice Description
Voice Length MuteLength
WordTotal
< 8000h
Addr-
ess
Signature & date
MVI Sales & date
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Preliminary
MOSEL VITELIC INC.
Product Request Form B : Minutes Reading Definitions Table
MSSW003
Specifications is subject to change without notice, contact your sales representatives for the most recent information
15/17
PID249** 04/96
T I T L E
:00
:01
:02
:03
:04
:05
:06
:07
:08
:09
:10
:11
:12
:13
:14
:15
:16
:17
:18
:19
:20
:21
:22
:23
:24
:25
:26
:27
:28
:29
:30
:31
:32
:33
:34
:35
:36
:37
:38
:39
:40
:41
:42
:43
:44
:45
:46
:47
:48
:49
:50
:51
:52
:53
:54
:55
:56
:57
:58
:59
:60(:00)
Minute
List of Entries (addresses)
Entry
Count
Entry count summation of above 61 minutes =
Note 2
Note 1
Note 1. This minute reading is not read by sentence 5.
Note 2. This minute reading is read only by sentence 5.
Signature & date
MVI Sales & date
Preliminary
MOSEL VITELIC INC.
Product Request Form C : Hour Reading Definitions
MSSW003
Specifications is subject to change without notice, contact your sales representatives for the most recent information
16/17
PID249** 04/96
T I T L E
24 Hour Format Definition Table
12 Hour Format Definition Table
Hour
List of Entries (addresses)
Hour
List of Entries (addresses)
01:
02:
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:(00:)
01:(13:)
02:(14:)
03:(15:)
04:(16:)
05:(17:)
06:(18:)
07:(19:)
08:(20:)
09:(21:)
10:(22:)
11:(23:)
12:(24:)(00:)
Entry
Count
Entry
Count
Entry count summation of above 12 hours =
Entry count summation of above 24 hours =
Entry count summation of above 3 tables =
(must be < 512)
These 3 tables are 24 hours,
12 hours and 61 minutes
Signature & date
MVI Sales & date
Preliminary
MOSEL VITELIC INC.
Product Request Form D : Vocabulary & Sentence Definitions
MSSW003
Specifications is subject to change without notice, contact your sales representatives for the most recent information
17/17
PID249** 04/96
T I T L E
SentenceIndex
List of Vocabularies
1
C
1
C
1
C
1
C
1
C
1
C
1
C
1
C
1
C
1
C
2
C
2
C
2
C
2
C
2
C
2
C
2
C
2
C
2
C
2
C
3
C
3
C
3
C
3
C
3
C
3
C
3
C
3
C
3
C
3
C
4
C
4
C
4
C
4
C
4
C
4
C
4
C
4
C
4
C
4
C
5
C
5
C
5
C
5
C
5
C
5
C
5
C
5
C
5
C
5
C
6
C
6
C
6
C
6
C
6
C
6
C
6
C
6
C
6
C
6
C
7
C
7
C
7
C
7
C
7
C
7
C
7
C
7
C
7
C
7
C
8
C
8
C
8
C
8
C
8
C
8
C
8
C
8
C
8
C
8
C
9
C
9
C
9
C
9
C
9
C
9
C
9
C
9
C
9
C
9
C
10
C
10
C
10
C
10
C
10
C
10
C
10
C
10
C
10
C
10
C
11
C
11
C
11
C
11
C
11
C
11
C
11
C
11
C
11
C
11
C
12
C
12
C
12
C
12
C
12
C
12
C
12
C
12
C
12
C
12
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
13
C
14
C
14
C
14
C
14
C
14
C
14
C
14
C
14
C
14
C
14
C
15
C
15
C
15
C
15
C
15
C
15
C
15
C
15
C
15
C
15
C
16
C
16
C
16
C
16
C
16
C
16
C
16
C
16
C
16
C
16
C
Definitions of Sentences
Definitions of Vocabularies
Sentence 1
Current Time
Sentence 2
Alarm is due
Sentence 3
Alarm time you set
Sentence 4
Adjust hour
Sentence 5
Adjust minute
Sentence 6
Set alarm off
Sentence 7
Set alarm on
Sentence 8
Set chime off
Sentence 9
Set chime on
Sentence 10
Mode changed
Vocabulary
Vocabulary
Vocabulary
Address or
Address or
Address or
C0
C1
C2
C3.AM
C3.PM
C4.Sound
C5.RESET
C6.RETURN
C7
C8.CARRY
C9
C10
C11
C12
C13
C14
C15
KeyWord
KeyWord
KeyWord
Hour.Table
Minute.Table
Signature & Date
MVI Sales & Date
Note. C5, C6, C8 all have to have length 800h or longer.
Note
Note
Note
Preliminary
MOSEL VITELIC INC.