DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 1/17
LCD Module Technical Specification
DMF5010NBU-FW-BD
Table of Contents
1. General Specifications
.................................................................................................................................. 2
2. Electrical Specifications
............................................................................................................................... 3
3. Optical Specifications
................................................................................................................................... 7
4. I/O Terminal
...................................................................................................................................................... 9
5. Test
................................................................................................................................................................... 11
6. Appearance Standards
............................................................................................................................... 12
7. Code System of Production Lot
............................................................................................................... 15
8. Type Number
.................................................................................................................................................. 15
9. Applying Precautions
.................................................................................................................................. 15
10. Precautions Relating Product Handling
................................................................................................ 16
11. Warranty
........................................................................................................................................................ 17
Checked by (Design Engineering Div.)
Checked by (Quality Assurance Div.)
Approved by (Production Div.)
Prepared by (Production Div.)
Revision History
Rev.
Date
Page
Comment
Type No.
Feb 22, 2002
O P T R E X
First Edition
Final Revision
******
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 2/17
1. General Specifications
Operating Temp.
: min. 0
C ~max. 50
C
Storage Temp.
: min. -20
C ~max. 60
C
Dot Pixels
: 240 (W)
64 (H) dots
Dot Size
: 0.49 (W)
0.49 (H) mm
Dot Pitch
: 0.53 (W)
0.53 (H) mm
Viewing Area
: 132.0 (W)
39.0 (H) mm
Outline Dimensions
: 200.0
*
(W)
66.0 (H)
23.0 max. (D) mm
* Without CFL Cable
Weight
: 277.36g max.
LCD Type
: NTD-7580
( STN / Blue-mode / Transmissive )
Viewing Angle
: 12:00
Control LSI
: T6963C-0101 (Produced by TOSHIBA)
Data Transfer
: 8-bit parallel data transfer
Backlight
: Cold Cathode Fluorescent Lamp (CFL)
1
Additional Spec.
: Holder and PWB ground are connected by soldering.
CFL light unit is replaceable.
Drawings
: Dimensional Outline UE-32421C
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 3/17
2. Electrical Specifications
2.1. Absolute Maximum Ratings
V
SS
=0V
Parameter
Symbol
Conditions
Min.
Max.
Units
Supply Voltage
(Logic)
V
CC
-V
SS
-
-0.3
7.0
V
Supply Voltage
(LCD Drive)
V
CC
-V
EE
-
0
28.0
V
Input Voltage
V
I
-
-0.3
V
CC
+0.3
V
2.2. DC Characteristics
Ta=25
C, V
SS
=0V
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Supply Voltage
(Logic)
V
CC
-V
SS
-
4.5
-
5.5
V
Supply Voltage
(LCD Drive)
V
CC
-V
EE
Shown in 3.1
V
High Level
Input Voltage
V
IH
V
CC
=5.0V
10%
V
CC
-2.2
-
V
CC
V
Low Level
Input Voltage
V
IL
V
CC
=5.0V
10%
0
-
0.8
V
High Level
Output Voltage
V
OH
I
OH
=-0.75mA
V
CC
-0.3
-
V
CC
V
Low Level
Output Voltage
V
OL
I
OL
=0.75mA
0
-
0.3
V
Supply Current
I
CC
V
CC
-V
SS
=5.0V
-
7.8
11.7
mA
I
EE
V
CC
-V
EE
=13.1V
-
2.7
4.05
mA
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 4/17
2.3. AC Characteristics
V
CC
=5.0V
10%
Parameter
Symbol
Min.
Max.
Units
C/D Setup Time
t
CDS
100
-
ns
C/D Hold Time
t
CDH
10
-
ns
CE, RD, WR Pulse Width
t
CE
,
t
RD
,
t
WR
80
-
ns
Data Setup Time
t
DS
80
-
ns
Data Hold Time
t
DH
40
-
ns
Access Time
t
ACC
-
150
ns
Output Hold Time
t
OH
10
50
ns
(WRITE)
(READ)
RD, WR
D0
D7
CE
C/D
D0
D7
t
DS
t
OH
t
DH
t
ACC
t
CE
,
t
RD
,
t
WR
t
CDH
t
CDS
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 5/17
2.4. Power Supply ON/OFF Sequence
2.4.1. ON Sequence
2.4.2. OFF Sequence
2.4.3. Reset Sequence
Please maintain the above sequence when turning on and off the power supply of the
module.
If V
EE
is supplied to the module while internal alternate signal for LCD driving (M) is
unstable or RESET is active, DC component will be supplied to the LCD panel. This may
cause damage to the LCD module.
RESET
VCC
VEE
SIGNAL
T
0
T
0
T
0
T
50ms
T
50ms
T>250
s
LEVEL
L Level
H Level
VCC
VEE
VCC
VSS
Power Off
Power On
Reset Cancellation
Reset
T
10 ms
VEE
VSS
VSS
VCC
VSS
VCC
VEE
VCC
0
t
0
t
SIGNAL
SIGNAL
LEVEL
VCC
(Without RESET Signal)
VEE
VSS
VSS
VCC
VSS
VCC
VEE
VCC
0
t
0
t
SIGNAL
SIGNAL
LEVEL
VCC
(Without RESET Signal)
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 6/17
2.5. Lighting Specifications
Ta=25
C
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units Notes
Lamp Voltage
V
L
-
-
270
-
Vrms
1
Lamp Current
I
L
-
4.0
5.0
6.0
mArms
2
Starting Voltage
V
S
-
-
900
-
Vrms
3
Surface Luminance
L
I
L
=5.0mA
400
-
-
cd/m
2
4
Average Life
T
AL
I
L
=5.0mA
10000
15000
-
hrs
5
Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after
lighting for 3 minutes .
Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured
after lighting for 3 minutes.
Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually
from 0V.
Note 4 :Surface Luminance is specified by the initial data of luminance measured at the center of
display surface after 20 minutes power on. ( All ON pattern )
Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its
initial value.
The Average life time of CFL is defined as the time when half or more of the testing CFLs
have become less bright than 50% of the initial brightness at continuous operation.
Recommended Inverter : HIU-32 ( Produced by HARISON )
CXA-L10L (DC 12.0V, Produced by TDK)
V
N
I
CFL Testing Circuit
L
F
C
VS
VL
IL
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 7/17
3. Optical Specifications
3.1. LCD Driving Voltage
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Recommended
Ta= 0
C
-
-
15.5
V
LCD Driving Voltage
V
CC
-V
EE
Ta=25
C
12.2
13.1
14.0
V
Note 1
Ta=50
C
10.8
-
-
V
Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The
range of minimum and maximum shows tolerance of the operating voltage. The
specified contrast ratio and response time are not guaranteed over the entire range.
3.2. Optical Characteristics
Ta=25
C, 1/64Duty, 1/9 Bias, V
OD
=13.1V (Note 4),
= 0
C,
=-
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Contrast Ratio
Note 1
CR
= 0
C ,
=-
-
7
-
Viewing Angle
Shown in 3.3
Response
Rise
Note 2
T
ON
-
-
110
200
ms
Time
Decay
Note 3
T
OFF
-
-
160
240
ms
Note 1 :Contrast ratio is definded as follows. (CR = L
ON
/ L
OFF
)
L
ON
: Luminance of the ON segments
L
OFF
: Luminance of the OFF segments
Note 2 :The time that the luminance level reaches 90% of the saturation level from 0%
when ON signal is applied.
Note 3 :The time that the luminance level reaches 10% of the saturation level from
100% when OFF signal is applied.
Note 4 :Definition of Driving Voltage V
OD
Assuming that the typical driving waveforms shown below are applied to the LCD
Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage
V
OD
is definded as the voltage V
O-P
when the contrast ratio (CR=L
ON
/ L
OFF
) is at its
maximum.
V
O-P
1 /
f
F
( B-2 )
V
O-P
/ B
1 / (
f
F
A )
<OFF SIGNAL>
<ON SIGNAL>
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 8/17
3.3. Definition of Viewing Angle and Optimum Viewing Area
*Point
shows the point where contrast ratio is measured. :
= 0
,
= -
*Driving condition : 1/64 Duty, 1/9 Bias, V
OD
=13.1V,
f
F
=70Hz
270
0
90
180
270
135
315
225
45
180
90
(
= 0
)
10
20
30
40
50
*Area
shows typ. CR
2
3.4. System Block Diagram
Halogen bulb
Computer
Rotation Table (
,
)
Temperature Chamber
LCD
Optical Fiber
Waveform Generator
Control Unit &
#1980A WB
Photometer
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 9/17
4. I/O Terminal
4.1. Pin Assignment
CN1
No.
Symbol
Function
1
FG
Frame Ground
2
V
SS
Power Supply (0V, GND)
3
V
CC
Power Supply for Logic
4
V
EE
Power Supply for LCD Drive
5
WR
Write Signal L : Active
6
RD
Read Signal L : Active
7
CE
Chip Enable Signal L : Active
8
C/D
Write Mode H : Command Write L : Data Write
Read Mode H : Status Read L : Data Read
9
NC
Non-connection
10
RESET
Reset Signal L : Reset
11
D0
Display Data
12
D1
Display Data
13
D2
Display Data
14
D3
Display Data
15
D4
Display Data
16
D5
Display Data
17
D6
Display Data
18
D7
Display Data
19
FS
Font Switch H : 6
8 dots L : 8
8 dots
20
NC
Non-connection
CN2
No.
Symbol
Function
1
CFL (HOT)
Power Supply for CFL (HOT)
2
NC
Non-connection
3
NC
Non-connection
4
CFL (GND)
Power Supply for CFL (GND)
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 10/17
4.2. Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the
tolerance of the driving voltage and its temperature dependence.
4.3. Block Diagram
VSS
MODULE
VEE
V C C
VEE (-Voltage)
VCC (+Voltage)
Tr=2SA1202 or equivalent
R1+R2+VR=10~ 20K
VSS (0V)
R 2
R 1
VR
Tr
CFL(GND)
CFL(HOT)
VEE
FG
VSS
VCC
FS
D0~D7
CE
RD
WR
C/D
RESET
or equivalent
T6A40
1
T6963C
Control LSI
Row Driver
or equivalent
T6A39
3
Column Driver
L C D P
3
240
240
64 dots
To LSI
Bias Circuit
CFL Backlight
8
3
4
64
8
13
64K S-RAM
X-tal
J
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 11/17
5. Test
No change on display and in operation under the following test condition.
Conditions: Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20
5
C
Humidity : 65
5%RH
tests will be not conducted under functioning state.
No.
Parameter
Conditions
Notes
1
High Temperature Operating
50
C
2
C, 96hrs (operation state)
2
Low Temperature Operating
0
C
2
C, 96hrs (operation state)
1
3
High Temperature Storage
60
C
2
C, 96hrs
2
4
Low Temperature Storage
-20
C
2
C, 96hrs
1,2
5
Damp Proof Test
40
C
2
C,90~95%RH, 96hrs
1,2
6
Vibration Test
Total fixed amplitude : 1.5mm
3
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 :No dew condensation to be observed.
Note 2 :The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after removed from the test chamber.
Note 3 :Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
D
C
F
60cm
Concrete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 12/17
6. Appearance Standards
6.1. Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45
against perpendicular line.
6.2. Definition of applicable Zones
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
A Zone
B Zone
C Zone
Bezel Flame
45
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 13/17
6.3. Standards
No.
Parameter
Criteria
1
Black and
(1) Round Shape
White Spots,
Zone
Acceptable Number
Foreign Substances
Dimension (mm)
A
B
C
D
0.1
*
*
*
0.1 < D
0.2
3
5
*
0.2 < D
0.25
2
3
*
0.25< D
0.3
0
1
*
0.3 < D
0
0
*
D = ( Long + Short ) / 2 * : Disregard
(2) Line Shape
Zone
Acceptable Number
X (mm) Y (mm)
A
B
C
-
0.03
W
*
*
*
2.0
L
0.05
W
3
3
*
1.0
L
0.1
W
3
3
*
-
0.1 < W
In the same way (1)
X : Length Y : Width * : Disregard
Total defects shall not exceed 5.
2
Air Bubbles
(between glass
Zone
Acceptable Number
& polarizer)
Dimension (mm)
A
B
C
D
0.3
*
*
*
0.3 < D
0.4
3
*
*
0.4 < D
0.6
2
3
*
0.6 < D
0
0
*
* : Disregard
Total defects shall not exceed 3.
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 14/17
No.
Parameter
Criteria
3
The Shape of Dot
(1) Dot Shape (with Dent)
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
(X+Y) / 2
0.2mm
(Less than 0.1mm is no counted.)
(4) Deformation
(X+Y) / 2
0.2mm
Total acceptable number : 1/dot, 5/cell
(Defect number of (4) : 1pc.)
4
Polarizer Scratches
Not to be conspicuous defects.
5
Polarizer Dirts
If the stains are removed easily from LCDP surface, the module is not
defective.
6
Complex Foreign
Black spots, line shaped foreign substances or air bubbles between
Substance Defects
glass & polarizer should be 5pcs maximum in total.
7
Distance between
D
0.2 : 20mm or more
Different Foreign
0.2 < D : 40mm or more
Substance Defects
0.15
X
X
Y
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 15/17
7. Code System of Production Lot
The production lot of module is specified as follows.
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Production Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8. Type Number
The type number of module is specified as follows.
DMF5010NBU-FW-BD
9. Applying Precautions
Please contact us when questions and/or new problems not specified in this
specificationsarise.
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 16/17
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
1. The liquid crystal display device panel used in the liquid crystal display module is
made of plate glass. Avoid any strong mechanical shock. Should the glass break
handle it with care.
2. The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
1. When working with the module, be sure to ground your body and any electrical
equipment you may be using. We strongly recommend the use of anti static mats
( made of rubber ), to protect work tables against the hazards of electrical shock.
2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton
clothing or other conductivity-treated fibers.
3. Slowly and carefully remove the protective film from the LCD module, since this
operation can generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
1. Protect the modules from high temperature and humidity.
2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
3. Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector
circuit, since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module.
Should hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conductivity is not guaranteed for models that use metal holders where solder
connections between the metal holder and the PCB are not used. Please contact
us to discuss appropriate ways to assure conductivity.
7) For models which use CFL:
1. High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket
to become worn.
3. The use of CFLs for extended periods of time at low temperatures will significantly
shorten their service life.
8) For models which use touch panels:
1. Do not stack up modules since they can be damaged by components on neighboring
modules.
2. Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
1. The mechanical strength of the product is low since the IC chip faces out
unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit
from electrical damage, avoid installation configurations in which the rear of the IC
chip runs the risk of making any electrical contact.
DMF5010NBU-FW-BD (BD) No. 2002-0045
OPTREX CORPORATION
Page 17/17
10) Models which use flexible cable, heat seal, or TAB:
1. In order to maintain reliability, do not touch or hold by the connector area.
2. Avoid any bending, pulling, or other excessive force, which can result in broken
connections.
11) In case of buffer material such as cushion / gasket is assembled into LCD module,
it may have an adverse effect on connecting parts ( LCD panel-TCP / HEAT SEAL /
FPC / etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT
SEAL-FPC, etc.,) depending on its materials.
Please check and evaluate these materials carefully before use.
12) In case of acrylic plate is attached to front side of LCD panel, cloudiness ( very
small cracks ) can occur on acrylic plate, being influenced by some components
generated from polarizer film.. Please check and evaluate those acrylic materials
carefully before use.
11. Warranty
This product has been manufactured to your company's specifications as a part for use
in your company's general electronic products. It is guaranteed to perform according to
delivery specifications. For any other use apart from general electronic equipment, we
cannot take responsibility if the product is used in medical devices, nuclear power
control equipment, aerospace equipment, fire and security systems, or any other
applications in which there is a direct risk to human life and where extremely high levels
of reliability are required. If the product is to be used in any of the above applications,
we will need to enter into a separate product liability agreement.
1. We cannot accept responsibility for any defect, which may arise from additional
manufacturing of the product (including disassembly and reassembly), after product
delivery.
2. We cannot accept responsibility for any defect, which may arise after the application
of strong external force to the product.
3. We cannot accept responsibility for any defect, which may arise due to the application
of static electricity after the product has passed your company's acceptance
inspection procedures.
4. When the product is in CFL models, CFL service life and brightness will vary according
to the performance of the inverter used, leaks, etc. We cannot accept responsibility
for product performance, reliability, or defect, which may arise.
5. We cannot accept responsibility for intellectual property of a third party, which may
arise through the application of our product to your assembly with exception to those
issues relating directly to the structure or method of manufacturing of our product.
6. Optrex will not be held responsible for any quality guarantee issue for defect products
judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one)
year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever
comes later.