ChipFind - документация

Электронный компонент: T-51410D104-FW-P-AE

Скачать:  PDF   ZIP
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 1/22
LCD Module Technical Specification
T-51410D104-FW-P-AE
***The part number and specification are still tentative.
Table of Contents
1. Applications
.................................................................................................................................................
2
2. Features
...........................................................................................................................................................
2
3. Mechanical Specifications
................................................................................................................
2
4. Mechanical Drawing TFT LCD Module
............................................................................
3
5. Input / Output Terminals
.................................................................................................................
5
6. Absolute Maximum Ratings
............................................................................................................
6
7. Electrical Characteristics
.....................................................................................................................
7
8. Power Sequence
....................................................................................................................................
13
9. Optical Characteristics
.....................................................................................................................
14
10. Handling Cautions
...............................................................................................................................
17
11. Reliability TEST
....................................................................................................................................
18
12. Block Diagram
.........................................................................................................................................
19
13. Packing
...........................................................................................................................................................
20
Checked by (Design Engineering Div.)
Checked by (Quality Assurance Div.)
Prepared by (Production Div.)
Revision History
Rev.
Date
Page
Comment
First Edition
Dec 17, 2001
Final Revision
******
O P T R E X
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 2/22
1.Application
This data sheet applies to a color TFT LCD module, T-51410D104-FW-P-AE.
T-51410D104-FW-P-AE module applies to OA product, car TV(must use Analog to Digital
drive board), which require high quality flat panel display. If you must use in high reliability
environment can't over reliability test condition
Prime View assume no responsibility for any damage resulting from the use of the device
which dose not comply with the instructions and the precautions in these specification sheet.
2. Features
. Amorphous silicon TFT LCD panel with back-light unit
. Pixel in stripe configuration
. Slim and compact, designed for O/A application
. Display Colors
262,144 colors
. Optimum Viewing Direction
6 o'clock
. Image Up/Down, Left/Right inversion function
. +3.3V DC supply voltage for TFT LCD panel driving
. Backlight driving DC/AC inverter not included in this module
3.Mechanical Specifications
Parameter
Specifications
Unit
Screen Size
26.4(diagonal)
cm
10.4 (diagonal)
inch
Display Format
800
(R, G, B)
600
dot
Display Colors
262,144
Active Area
211.2(H)
158.4 (V)
mm
Pixel Pitch
0.264 (H)
0.264 (V)
mm
Pixel Configuration
Stripe
Outline Dimension
243 (w)x185.1(H)x11(typ.) (D)
mm
Weight
490(typ.),
g
Back-light
CCFL, 2 tubes
Surface treatment
Anti-glare and hard-coating
Display mode
Normally white
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 3/22
4.Mechanical Drawing of TFT-LCD Module
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 4/22
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 5/22
5.Input Terminals
5-1) TFT-LCD Panel Driving
Connector type: HIROSE, DF9B-41P-1V (or equivalent)
Pin No.
Symbol
Function
Remark
1
GND
Ground
2
CLK
Clock
3
GND
Ground
4
Hsync
Horizontal sync
5
Vsync
Vertical sync
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
R0
Red data(LSB)
10
R1
Red data
11
R2
Red data
12
GND
Ground
13
R3
Red data
14
R4
Red data
15
R5
Red data(MSB)
16
GND
Ground
17
GND
Ground
18
GND
Ground
19
G0
Green data(LSB)
20
G1
Green data
21
G2
Green data
22
GND
Ground
23
G3
Green data
24
G4
Green data
25
G5
Green data(MSB)
26
GND
Ground
27
GND
Ground
28
GND
Ground
29
B0
Blue data(LSB)
30
B1
Blue data
31
B2
Blue data
32
GND
Ground
33
B3
Blue data
34
B4
Blue data
35
B5
Blue data(MSB)
36
GND
Ground
37
NC
No connect
38
SDS
Scan direction select
Note 5-1
39
Vcc
Power supply
40
Vcc
Power supply
41
NC
No connect
Note 5-1:SDS can change scan direction .
High or open = normal scan, Low = reverse scan
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 6/22
5-2) Backlight driving
Connector type : "BHR-03VS-1" of
Japan Solderless Terminal MFG Co. LTD
PIN NO.
Symbol
Description
Remark
1
LV
Ground
White
2
HV
Lamp power input
Pink (or Gray)
3
HV
Lamp power input
Pink (or Gray)
6.Absolute Maximum Ratings:
GND=0V, Ta=25C
Parameters
Symbol
MIN.
MAX.
Unit
Remark
Supply Voltage
Vcc
-0.3
+3.6
V
Backlight Driving Voltage
V
L
-
2000
V
Backlight Driving Frequency
F
L
0
100
KHz
Storage Temperature
T
ST
-20
+60
C
Note 6-1
Operating Temperature
T
OP
0
+50
C
Note 6-1: Humidity : 90% RH Max. at Ta
40C.
Maximum wet-bulb temperature is at 39Cor less at Ta > 40Cand no
condensation.
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 7/22
7.Electrical Characteristics
7-1) Recommended Operating Conditions:
GND = 0V
Ta = 25
Item
Symbol
Min.
Typ.
Max.
Unit
Remark
Supply Voltage
VDD
3.0
3.3
3.6
V
Current Dissipation
I
DD
-
350
450
mA
Note 7-1
Lamp Current
I
FL
3.02
7.02
8.02
mA
Note 7-2
Note 7-4
Lamp Voltage
V
L
400
430
530
Vrms
Note 7-2
Lamp Initial Voltage
V
SFL
-
-
875
Vrms
at Ta=25
C
Note 7-3
-
-
1300
at Ta=0
C
Note 7-3
Lamp Driving Frequency
F
L
30
55
60
KHz
Lamp power consumption
4
8
11
W
Note 7-4
Lamp Life Time
30000 40000
Hrs
Note 7-5
LCD Panel Life Time(MTBF)
50000
Hrs
Note 7-1 : To test the current dissipation of VDD, using the "color bars" testing pattern
shown as below
1
2
3
4
5
6
7
8
1.
White
2.
Yellow
3.
Cyan
4.
Green
5.
Magenta
6.
Red
7.
Blue
8.
Black
Idd current dissipation testing pattern
Note 7-2 : The back-light driving waveform should be as closed to sine-wave as possible.
In order to satisfy the quality of B/L , no matter use what kind of inverter , the
output lamp current must between Min. and Max. to avoid the abnormal
display image caused by B/L.
Note 7-3 : Not including the efficiency of backlight DC/AC inverter
Note 7-4 : Lamp current is measured with current meter for high frequency as shown below
Inverter
TFT-LCD
Module
~
A
* Pin 3 is V
low
** Current meter :
Yokogawa 2016-01
3
2
1
Note 7-5: The life time is determined as the time at which brightness of lamp is 50%
compare to that of initial value at the typical lamp current.
7-2) Input signal timing chart
Lamp current dissipation testing configuration
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 8/22
Symbol
Min.
Typ.
Max.
Unit
Remarks
Power supply
Vcc
3.0
3.3
3.6
V
1/tc
40
MHz
40MHz(Typ.)
tc
25
ns
tc(High)
9
ns
CLK
Frequency
tc(Low)
9
ns
26.4
us
Period
Hp
1056
tc
Display period
Hd
800
tc
Pulse width
Hpw
12
128
128
tc
Back-porch
Hbp
86
86
202
tc
Front-porch
Hfp
42
tc
Hpw+Hbp
214
tc
Hsync-CLK
Hhc
10
Tc-10
ns
Hsync
Vsync-Hsync
Hvh
2
Hp-2
tc
16.579
ms
Period
Vp
628
628
780
Hp
60.3Hz(Typ.)
Display period
Vdp
600
Hp
Pulse width
Vpw
1
4
4
Hp
Back-porch
Vbp
22
22
25
Hp
Front-porch
Vfp
2
2
754
Hp
Vsync
Vpw+Vpb
26
Hp
CLK-DATA
Dcd
10
ns
DATA
R0~R5
G0~G5
B0~B5
DATA-CLK
Ddc
7
ns
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 9/22
(A)CLK,DATA relationship
(B)Hsync Timing
CLK
tc(Low)
tc(High)
tc
V
IH
(Min):0.8V
cc
V
IL
(Max):0.2V
cc
DATA
R5-R0
G5-G0
B5-B0
VALID
DATA
Input Signal
CenterLevel:
0.5V
cc
V
IH
(Min):0.8V
cc
V
IL
(Max):0.2V
cc
CLK
a
b
0.5V
cc
Duty ( a ,b ) : 50 10%
Dcd
Ddc
Hsync
Display period
Hpw
Hbp
Hp
Hfp
Hdp
R5~R0
G5~G0
B5~B0
1,Y2,Y 3,Y 4,Y 5,Y 6,Y7,Y
X,Y
798,Y 800,Y
797,Y 799,Y
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 10/22
(C)CLK,Hsync relationship:
(D)Hsync,Vsync relationship
(E)Vsync Timing:
Hsync
CLK......
Hhc
Vsync........
Hsync.......
Hvh
Vsync
Display period
Vpw
Vbp
Vp
Vfp
Vdp
X,1 X,2 X,3 X,4
X,598X,599X,600
X,Y
R5 R0
G5 G0
B5 B0
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 11/22
7-3) Display Color and Gray Scale Reference
Input Color Data
Color
Red
Green
Blue
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Black
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Red (63)
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
Green
(63)
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
Basic
Blue (63)
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
Colors
Cyan
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
Magenta
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
Yellow
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
White
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Red (00)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Red (01)
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Red (02)
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
Darker
Red
Brighter
Red (61)
1
1
1
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Red (62)
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
Red (63)
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
Green
(00)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Green
(01)
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
Green
(02)
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Darker
Green
Brighter
Green
(61)
0
0
0
0
0
0
1
1
1
1
0
1
0
0
0
0
0
0
Green
(62)
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
Green
(63)
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
Blue (00)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Blue (01)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Blue (02)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
Darker
Blue
Brighter
Blue (61)
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
Blue (62)
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
Blue (63)
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 12/22
7-4) Pixel Arrangement
The LCD module pixel arrangement is the stripe.
R G B R G B R G B
R G B
R G B R G B
R G B
R G B R G B R G B
R G B
R G B R G B
R G B
3rd Line
2 nd Line
1st Line
600 th Line
599 th Line
598 th Line
R G B
R G B
R G B
R G B
1 st Pixel
800 th Pixel
1 Pixel = R G B
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 13/22
8.)Power On Sequence
1. The supply voltage for input signals should be same as V
CC.
2. When the power is off , please keep whole signals (Hsync, Vsync, CLK, Data) low level
or high impedance
3.0 V
3.0 V
0 s< t <35 ms
0 s< t <35 ms
2t
1
0<t
1
Signal
Backlight
V
CC
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 14/22
9.) Optical Characteristics
9-1) Specification:
Ta = 25
Parameter
Symbol
Condition
MIN.
TYP.
MAX.
Unit
Remarks
Horizontal
55
60
-
deg
(to 12
o'clock)
35
40
-
deg Note 9-1
Viewing Angle
Vertical
(to 6
o'clock)
CR
10
50
55
-
deg
Contrast Ratio
CR
Optimum
direction
100
180
-
-
Note 9-2
Rise
Tr
-
15
50
ms
Response time
Fall
Tf
=0
=0
-
25
50
ms
Note 9-4
Luminance
L
=0
/
=0
310
350
-
cd/
, Note 9-3
Luminance Uniformity
U
50
80
-
%
Note 9-5
x
0.290 0.340 0.390
-
White Chromaticity
y
0.290 0.340 0.390
-
Cross Talk Ratio
CTK
-
-
3.5
%
Note 9-6
All the optical measurement shall be executed 30 minutes after backlight being turn-on. The
optical characteristics shall be measured in dark room (ambient illumination on panel surface
less than 1 Lux). The measuring configuration shows as following figure.
Photometer (TOPCON
BM-5A or BM-7 fast)
500
mm
+/-
50
mm
TFT-LCD module
DC/AC Inverter
Optical characteristics measuring configuration
Field = 2
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 15/22
Note 9-1`
The definitions of viewing angles are as follows.
12 o'clock
3 o'clock
9 o'clock
6 o'clock
q
f
Lamp connector
Note 9-2 : The definition of contrast ratio
CR
Luminance at gray level 63
Luminance at gray level 0
=
Note 9-3
Topcon BM-5A
luminance meter 2
field of view is used in the testing (after 30
minutes' operation). The typical luminance value is measured at lamp current 14.0
mA.
Note 9-4: Definition of Response Time T
r
and T
f
:
100%
90%
10%
0%
White
White
B
r
i
g
h
t
n
e
s
s
Black
Tr
Tf
Note 9-5: The uniformity of LCD is defined as
The Minimum Brightness of the 9 testing Points
U =
The Maximum Brightness of the 9 testing
Points
Luminance meter : BM-5A or BM-7 fast(TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 16/22
The test pattern is white (Gray Level 63).
25%
50%
75%
25%
50%
75%
YA-YB
Note 9-6: Cross Talk (CTK) =
YA
100%
YA: Brightness of Pattern A
YB: Brightness of Pattern B
Luminance meter : BM 5A (TOPCON)
Measurement distance : 500 mm +/- 50 mm
Ambient illumination : < 1 Lux
Measuring direction : Perpendicular to the surface of module
Pattern A
(Gray Level 31)
Pattern B
(Gray Level 31, central
black box exclusive)
: Measuring Point (A and B are at the same point.)
YA
YB
1/3
1/3
1/3
1/3
1/3
1/3
Black
(Gray Level 0)
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 17/22
10. Handling Cautions
10-1) Mounting of module
a) Please power off the module when you connect the input/output connector.
b) Please connect the ground pattern of the inverter circuit surely. If the
connection
is not perfect, some following problems may happen possibly.
1.The noise from the backlight unit will increase.
2.The output from inverter circuit will be unstable.
3.In some cases a part of module will heat.
c) Polarizer which is made of soft material and susceptible to flaw must be
handled carefully.
d) Protective film (Laminator) is applied on surface to protect it against scratches
and dirts. It is recommended to peel off the laminator before use and taking
care of static electricity.
10-2) Precautions in mounting
a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled,
wipe it with soft dry cloth.
b) Wipe off water drops or finger grease immediately. Long contact with water may
cause discoloration or spots.
c) TFT-LCD module uses glass which breaks or cracks easily if dropped or
bumped on hard surface. Please handle with care.
d) Since CMOS LSI is used in the module. So take care of static electricity and
earth yourself when handling.
10-3) Adjusting module
a) Adjusting volumes on the rear face of the module have been set optimally
before shipment.
b) Therefore, do not change any adjusted values. If adjusted values are changed,
the specifications described may not be satisfied.
10-4) Others
a) Do not expose the module to direct sunlight or intensive ultraviolet rays for
many
hours.
b) Store the module at a room temperature place.
c) The voltage of beginning electric discharge may over the normal voltage
because of leakage current from approach conductor by to draw lump read lead
line around.
d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel.
Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes
or feet. Wash it out immediately with soap.
e) Observe all other precautionary requirements in handling general electronic
components.
f) Please adjust the voltage of common electrode as material of attachment by 1
module.
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 18/22
11. Reliability Test
No
Test
Item
Test
Condition
Remark
1
High Temperature Storage Test
Ta = +60
, 240 hrs
2
Low Temperature Storage Test
Ta = -20
, 240 hrs
3
Low Temperature Operation Test Ta = 0
, 240 hrs
4
High Temperature & High Humidity
Operation Test
Ta = +50
, 80%RH, 240 hrs
(No Condensation)
5
Thermal Cycling Test
(non-operating)
0
+25
+60
, 50 Cycles
1Hr
0.5Hr
1Hr
6
Vibration Test
(non-operating)
Frequency
10 ~ 57 H
Z ,
Amplitude
0.15 mm
58~500Hz, 1G
Sweep time: 11 min
Test Period: 3 hrs (1 hr for each direction of
X, Y, Z)
7
Shock Test
(non-operating)
80G, 6ms, X,Y, Z
1 times for each direction
Ta: ambient temperature
[Judgement Criteria]
Under the display quality test conditions with normal operation state , there should be no
change which may affect practical display function.
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 19/22
12.)Block Diagram
1
2
3
599
598
600
4
2
1
2400
C
o
n
t
r
o
l
C
i
r
c
u
i
t
TF T-LC D
D isplay A rea
B ack-ligh t(Lam p1)
V L1
V L2
3
S ource D river
G
a
t
e
D
r
i
v
e
r
Pow er
M odule
V D D
H D
CL K
R0
R1
G 0
G 11
B0
B1
R5
G 5
B5
...
...
...
V L3
V D
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 20/22
13.)Packing
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 21/22
OPTREX CORPORATION
T-51410D104-FW-P-AE
Page 22/22