OS-LM01A
LINEARlight
Data Sheet
Benefits
Available in various colors
Small height
Minimal heat generation
Wide viewing angle
Easy installation
Applications
Path & contour marking
Edge-lighting of transparent or diffused
materials
Emergency/Rescue signs
To couple light into transparent or
diffused glass
Color
Voltage
[V DC]*
Power
[W]*
Radiance
Angle []*
Wavelength [nm]
Color Temp [K]*
Lum. Flux
[lm]*
Current
[A]*
Product
Number of
LEDs
Technical Operating Data
white
10
3,2
120
5400 K
29
0,32
OS-LM01A-W1-854
32
white
10
3,2
120
4700 K
29
0,32
OS-LM01A-W1-847
32
super red
10
4,0
120
633 nm
54
0,4
OS-LM01A-S1
32
red
10
4,0
120
617 nm
54
0,4
OS-LM01A-A
32
orange
10
4,0
120
606 nm
86
0,4
OS-LM01A-O1
32
yellow
10
4,0
120
587 nm
69
0,4
OS-LM01A-Y1
32
green
10
4,0
120
525 nm
36
0,4
OS-LM01A-T1
32
blue
10
4,0
120
470 nm
9
0,4
OS-LM01A-B1
32
All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
*)
Technical Features
Modules optimized for use with OSRAM
OPTOTRONIC power supplies.
Parallel connection up to three modules
Only parallel connection allowed
Smallest unit of 4 LEDs can be cut out at
regular intervals without damaging the rest of
the module
Mounting hole ( 4 mm) allows easy installation
with screws or standard circuit board support
hardware
The LINEARlight is certified according EN
60825-1(optical radation hazards)
Size of smallest unit 4 LED
(LxW): 56 mm x 10 mm
Size of printed circuit board (LxWxH) 448 mm x
10 mm x 4 mm
Also available: LINEARlight Flex on flexible
PCB for long applications : please refer to
Datasheet OS-LM10A or OS-LM11A
OS-LM01A - 25.11.03
Seite 1 von 4
Drawing
Operating Temperature
at Tc-Point [ C ] *
Storage Temperature
[ C ] *
Product
Voltage Range
[ V dc ] *
Reverse Voltage
[ V dc ] *
Minimum and Maximum Ratings
OS-LM01A-W1-854
10
11
11
...
-30
75
-40
85
...
...
OS-LM01A-W1-847
10
11
11
...
-30
75
-40
85
...
...
OS-LM01A-S1
10
11
11
...
-30
85
-40
85
...
...
OS-LM01A-A
10
11
11
...
-30
85
-40
85
...
...
OS-LM01A-O1
10
11
11
...
-30
85
-40
85
...
...
OS-LM01A-Y1
10
11
11
...
-30
85
-40
85
...
...
OS-LM01A-T1
10
11
11
...
-30
75
-40
85
...
...
OS-LM01A-B1
10
11
11
...
-30
75
-40
85
...
...
Exceeding maximum ratings for operation and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operation voltage will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module has to measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label (available e.g. at RS-Components). For exact location of the Tc-point see drawing below.
*)
OS-LM01A - 25.11.03
Seite 2 von 4
Safety Information
The LED module itself and all its components may not be mechanical stressed.
Assembly must not damage or destroy conducting paths on the circuit board.
The LED Module incorporates no protection against: Short circuits, Overload, Overheating. Therefore it is absolutely necessary to
operate the modules with a electronically stabilised power supply offering protection against the above mentioned safety risks.
For dimming applications attention should be paid to specific references in "OPTOTRONIC Technical Guide".
Parallel connection is highly recommended as safe electrical operation mode.
Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and demage the LED module.
Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
Correct electrical polarity needs to be observed. Wrong polarity will result in no light emission.
OSRAM OPTOTRONIC power supplies are specifically designed with the necessary protection features for
safe operation.
When using other power supplies other than OPTOTRONIC the following basic safety features are required, in addition to any other
application specific concerns and local safety codes:
Short circuit protection
Overload protection
Overheat protection
Correct output voltage


The mounting of the module is carried out by attaching it at the mounting holes. Mounting screws should be treated with synthetic
washers to prevent circuit board damage and possible short circuiting.
A maximum of 3 Modules can be installed consecutively from any power feed. Operation with more than 3 LINEARlight modules
will reduce photometric performance and exceed the current carrying capacity of the module.
The LINEARlight can typically survive transient current levels of up to 2 Amperes. As a general design precaution, if the maximum
output current of the power supply is more than 2 Amperes, fast- blow fuses should be incorporated into the wiring plan.
Pay attention to ESD steps when mounting the module
The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability
to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason
for no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modifications
first ( cutting, wiring) and then apply a conformal coating in the final stages of installation.
Damage by corrosion will not be honored as a materials defect claim. It is the users responsibility to provide suitable protection
against corrosive agents such as moisture and condensation and other harmful elements.
For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable
protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade
conformal coating. The conformal coating should have the following features:
- Optical transparency
- UV-resistance
- thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K
- low permeability of steam for all climatic conditions
- resistance against corrosive environment
The lacquer APL of the company Electrolube http://www.electrolube.com met the conditions for the LINEARlight in our tests.
OS-LM01A - 25.11.03
Seite 3 von 4
Assembly Information
Solder connections should only be performed on designated solder pads ( marked "10V +/-"). During soldering, do not exceed the
maximum soldering time of 10 seconds and the maximum soldering temperature of 260C.
Each module can be seperated into submodules of 4 LEDs each by carefully sawing or cutting at the marked lines
Productgroup
Productname
EAN *
S-Unit *
Ordering Guide
LINEARlight
OS-LM01A-W1-854
4050300817095
10
LINEARlight
OS-LM01A-W1-847
4050300817118
10
LINEARlight
OS-LM01A-S1
4050300797687
10
LINEARlight
OS-LM01A-A
4050300922508
10
LINEARlight
OS-LM01A-O1
4050300798721
10
LINEARlight
OS-LM01A-Y1
4050300948614
10
LINEARlight
OS-LM01A-T1
4050300948621
10
LINEARlight
OS-LM01A-B1
4050300948607
10
EAN: Ordering number per single module
S-Unit: Modules per shipping unit
*)
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Related and Further Information
The new dimension of light
(in preparation)
New creativity in lighting design
LED Modules for illuminated signs
153 S07 E
OPTOTRONIC Technical Guide
130 T08 E
OPTOTRONIC Data Sheets
www.osram.com
Sales and Technical Support
OSRAM
Opto Semiconductors GmbH
Wernerwerkstrasse 2
D - 93049 Regensburg
Germany
www.osram-os.com
OSRAM GmbH
Hellabrunner Strasse 1
D - 81536 Mnchen
Germany
www.osram.com
+49 (0)89 6213-0
See web-page for local phone numbers