ChipFind - документация

Электронный компонент: TC139/279SP

Скачать:  PDF   ZIP
Features
n
Connection-ready module for E4/STM-1/OC3 applications
n
Maximum operating distance exceeds 200 meters on 75 ohm RG-6/u and RG-11/u coaxial cable
n
Tested and proven interface using AMCC S3015/S3016 chip sets
n
Loss-of-signal (LOS) detection
n
Low transmit/receive jitter
n
Encoder and decoder
n
Clock recovery
n
Typical power dissipation of 10.8W at 12Vdc (with voltage regulator)
n
See applicable specifications below
Copperhead
TM
bi-directional fiber
(NRZ) to copper (CMI)
converters
Compact, easy to install
modules provide all
connections and signal conditioning
for NRZ/CMI network junctions
CopperheadTM bi-directional converters allow network developers to conveniently utilize both fiberoptic- and coax-con-
nected system components in network configurations, and to conduct bi-directional cross media data, voice, and video
communications at fibre speed data rates.
It provides a convenient, self-contained interface with all connections necessary for installation onto the network.
Besides the signal connections, all that is required is 12Vdc power.
The TC155/311 converts and conditions 155.52 Mb/s NRZ over fiber signals to 311 Mb/s CMI over copper signals for
Telecom/SONET (OC-3/STM-1) applications. It interfaces, regenerates, performs a protocol conversion, and clocks the
optical and electrical signals. It can be used in single and multi-mode fiber applications. The heart of the TC155/311
converter is its CopperheadTM transceiver, which minimizes output waveform jitter to ITU-T G.703 masking requirements
and corrects for the distortion of high frequency input signals received over coaxial cable. The proprietary transceiver permits
311 Mb/s communication over a remarkable distance of up to 200 meters of 75 ohm, RG-6/u coaxial cable.
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
n
CE Certified
n
Meets FCC Class A, 55022 Class A CISPR
n
IEC 1000-4-2 EN50082-1, Criteria B, Level 2
n
IEC 801-3 EN50082-1, Criteria A
n
IEC 1000-4-4 EN50082-1, Criteria B, Level 3 (on I/O Ports)
n
IEC 950:(1991,1992,1993) Safety Regulations
Technical description
The TC155/311 Converter converts fiber (NRZ coding) to coax (CMI coding) and coax (CMI cod-
ing) to fiber (NRZ coding).
Coax (CMI) receiver: The receiver performs equalization, isolation (AC coupled), amplification
and clock recovery on the CMI serial data stream from coax. The serial data stream is decoded
from CMI to NRZ. The NRZ serial data stream is fed to the fibre transceiver (TX side).
Fiber (NRZ) receiver: Clock recovery is performed on the NRZ serial data stream received from
the fiber. The NRZ data is encoded to Coded Mark Inversion (CMI). The CMI data is converted
to an appropriate media drive level and is fed to the coax transceiver (TX side). Here, the signal
is pre-conditioned with an output filter to meet G.703 output masks (for binary "ones" and "zeros")
and launched on the coax cable through interfacing wideband pulse transformers.
Automatic reset circuit: The TC155/311 converter also includes an automatic reset when the
power is turned on, and when the coax or fiber signal detect goes from a logic low to a high.
-20 dB monitor access point: In addition, the converter includes a -20dB monitor access point.
This allows for utilizing the converter in applications where a -20dB buffer has been installed to
prevent disturbing the signal under test.
Benefits of transformer coupling
The pulse transformers used in CopperheadTM transceivers provide high isolation and
optimum damping of transients. They also eliminate DC components in the signal and provide
common mode signal rejection. The transformer is also used to perform impedance matching of
the load to the source to provide maximum power transfer, and also to prevent reflections from
transmission line effects.
(Figure 1) Actual oscilloscope tracing of 311 Mb/s
unequalized input to receiver pins 13 and 14 after
transmission over 200 meters of RG-6/u coaxial
cable.
(Figure 2) Tracing of the same signal after
equalization. Receiver output measured at pins
2 and 3.
BEFORE
(unequalized)
AFTER
(equalized for CMI)
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 2
TC155/311 function diagram
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 3
Rx BNC
(CMI
data)
transformer
20 dB
monitor
ESD
protection
signal
detect
amplifier
and buffer
equalizer
and filter
lock
detector
phase/frequency
discriminator
line
driver
CMI decoder
buffer
clock recovery
clock
recovery
phase/frequency
discriminator
buffer
and
filter
CMI
encoder
filter and ESD
protection
transformer
Tx BNC
(CMI data)
Rx
NRZ data
fiber transceiver
Tx
NRZ data
General Electrical Parameters
Table 1
Absolute Maximum Ratings
Connections
Converter & data link LEDs
PARAM ET ER
SYM
MIN
MAX
UNIT
Storage te mperature
T
S
-40
+75
C
Operating temperature ambient, active
T
A
0
+40
C
Pow er supply voltage (regulator)
1
V
CC
10.8
13.2
V
Pow er supply current
1
I
C
-
1.0
A
Pow er dissipation (total)
1
P
D
-
13.2
W
Weight
#
-
1
pounds
Size: 6.50"L x 4.60"W x 1.50" H
-
-
-
inches
Size: 165 x 117 x 38 mm
-
-
-
millimeters
Table 2
Note 1: Measured @ 12 Vdc
Note 2: Coas transmitter meets ITU-T G.703 data masks
Note 1: Using RG-6/u coaxial cable.
Note: The numbers and parameters shown are derived from Recommendation G.703.
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 4
Fiber transceiver
SC connector provides link to cable; single mode and multi mode options are available
Copper co nnections
Tw o 75 ohm BNC
Power connector
2.0 m m male pow er jack on converter to mate w ith 2.1m m female pow er plug
Earth ground
In order to meet all EMC requirements, a 16 AW G or heavier (2 feet max) w ire must be
connected betw een earth ground of the converter and earth ground of the pow er source
Fiber
Indicates that data is present on the receiver
Copper
Indicates that data is present on the receiver
Power status
Indicates that pow er is connected to the pow er jack
PA RAMET ER
TC1 55/31 1 STM-1 O C-3
TC139/279 E4/STM-1 OC-3
U NIT
Data rate
155.52
139.264
MBaud/s
No minal bit rate
311.04
278.528
Mb/s
Tolerance
100
100
pp m
Operating distance ( min)
single mode fiber (long reach)
40
40
K meters
Operating distance ( min)
multimode fiber
2
2
K meters
Operating distance ( min)
1
100 + 20dB
100 + 20dB
meters
Cable i mpedance
1
75
75
oh ms (nom)
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 5
Mechanical Dimensions
Part Number Example:
TC 155/311 S P (USA)
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 6
Ordering Information
(USA) --------- Country Plug Identification (configuration and voltage)
P ---------- Power supply (external) provided
S ---------- Single Mode Fiber Transceiver
M ---------- Multi Mode Fiber Transceiver
155/311 ------- Baud/data rate
139/279 ------- Baud/data rate
TC ------- Identifies Technitrol Converter
Related Products
Series
Features
T M311DVA
311.04 Mb version SON ET ST M1 (also SO NET E4 278.528 Mb) CMI
T M311TRFVA
311.04 Mb version SON ET ST M1 (also SO NET E4 278.528 Mb) CMI w ith G.775 LOS
T M622 Series
622.08 Mbaud version SO NET OC-12, STM-4
T-330SC T
330 Mbaud "H OT LINK" / 265.625 Mbaud version 1/4 speed Fibre Channel Transfor mer
T-1062SCT
1.0625 Gbaud version full speed Fibre Channel Transfor mer
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
CMI Converter -- 7
Declaration of EU Conformity
Harmo nized Stan dards
EN 55022: (1993)
Measurement of radio disturbance characteristics of infor mation technology equipment
CIS PR Class A.
EN50081-1:(1991)
Generic Emission Standard. Part 1: Residential - Standard for using products in domestic,
commercial and light-industrial environments.
EN50082-1:(1991)
Generic Immunity Standard. Part 1: Residential - General i mmunity standard for using products
in domestic, commercial and light-industrial environ ments.
Test Standards
IEC 801.3
EMC Radiated Immunity
IEC 1000-4-2
IEC 801.2
ESD Test Method
IEC 1000-4-4
IEC 801.4
EFT Test Method
EN50082-1
Perfor mance Criteria A
EN50082-1
Perfor mance Criteria B, Level 2
EN50082-1
Perfor mance Criteria B, Level 3 (at I/O Port)
Safety
IEC 950: (1991);
A mend ment 1:(1992);
A mend ment 2:(1993)
Safety of Infor mation Technology Equipment
Application of Council Directive: 89/336/EEC
Standards to which conformity is declared are as follows:
Manufacturer's Name:
Pulse Specialty Components
A Technitrol Company
Two Pearl Buck Court
Bristol, PA 19007-6812 USA
CE Mark Test Reports on File in Europe:
Pulse
Dunmore Road
Tuam10
Co. Galway, Ireland
Type of Equipment:
Information Technology Equipment
Equipment Class:
Commercial & Light Industrial
Model:
C155/311 Converter
Year of Manufacture:
1996,1997
Technical File Number: TP 10327
Pulse Specialty Components hereby declares that the equipment specified above conforms to the above
Directive(s) and Standard(s). This Declaration is the sole responsibility of Pulse Specialty Components.
1) Buyer promptly notifies Pulse Specialty Components in
writing within the warranty period, and
2) The defective product or part is returned to Pulse Specialty
Components with transportation charges prepaid by Buyer,
and
3) Pulse Specialty Components examination of such product
shall disclose to its satisfaction that said defect exists and
has not been caused by misuse, neglect, improper installa
tion, repair or alteration, or accident.
EXCEPT FOR THE ABOVE WARRANTY AND THE IMPLIED WARRANTY OF TITLE,
PULSE SPECIALTY COMPONENTS MAKES NO OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE. NO LIABILITY IS ASSUMED FOR
EXPENDABLE ITEMS SUCH AS LAMPS AND FUSES. PULSE SPECIALTY COMPO-
NENTS WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
UNDER ANY CIRCUMSTANCES.
WARRANTY
Pulse Specialty Components warrants for a period of 90 days from the date
of shipment, that under normal use and service, its products will be free from
defects in workmanship and material. Pulse Specialty Components' sole
responsibility under this warranty is, at its option, to repair or replace, with-
out charge, any defective product or part, or to credit buyer for the purchase
price of such defective product, provided:
Catalog #CONV-0200
Issue Date 4/10/00
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com