EC 26
www.recom-international.com
Selection Guide
ECONOLINE - DC/DC-Converter
RK and RH Series, 1 Watt, SIP7, 3kV/4kV (Single & Dual Output)
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Part
Input
Output
Output
Efficiency
Number
Voltage
Voltage
Current
SIP 7
(4kV)
(VDC)
(VDC)
(mA)
(%)
RK-XX1.8S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
1.8
555
70
RK-XX3.3S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
3.3
303
75
RK-XX05S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
5
200
70-78
RK-XX09S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
9
111
70-80
RK-XX12S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
12
84
78-82
RK-XX15S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
15
66
78-82
RK-XX24S
(H)
1.8, 3.3, 5, 9, 12, 15, 24
24
42
74-83
RH-XX1.8D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
1.8
278
70
RH-XX3.3D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
3.3
152
70
RH-XX05D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
5
100
70-78
RH-XX09D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
9
56
75-80
RH-XX12D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
12
42
78-84
RH-XX15D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
15
33
80-84
RH-XX24D
(H)
1.8, 3.3, 5, 9, 12, 15, 24
24
21
80-84
Input Voltage
10%
Input Filter
Capacitor Type
Output Voltage Accuracy
5%
Line Voltage Regulation
1,2%/1% V Input
Load Voltage Regulation
1.8V, 3.3V output types
20% max.
(10% to 100% full load)
5V output type
15% max.
9V, 12V, 15V, 24V output types
10% max.
Ripple and Noise (20MHz limited)
Single output types
100mVp-p max.
Dual output types
75mVp-p max.
Efficiency at Full Load
70% min.
Isolation Voltage
3.000VDC min.
(also available with 4.000VDC, Suffix `H')
Isolation Resistance (Viso = 500VDC)
15 G min.
Isolation Capacitance
20pF min./65pF max.
Short Circuit Protection
1 Second
Switching Frequency at Full Load
57kHz min. / 105kHz max.
Operating Temperature
40C to +85C (see Graph)
Storage Temperature
-55C to +125C
Package Weight
2.8g
Safety standards and approvals:
EN 60950 certified, rated for
250VAC (LVD test report)
3kVDC (4kVDC Option) Isolation
Power Sharing on Dual Output
Efficiency to 78%
1.8, 3.3, 5V, 9V, 12V, 15V and 24V
Output
Custom Solutions Available
UL94V-0 Package Material
Features
Output Power (W
atts)
2.0
1.5
0.5
1.0
100
50
0
-40
85
125
150
Operating Temperature C
Safe Operating Area
0
Updated: 7. March 2003