ChipFind - документация

Электронный компонент: 90KS200C

Скачать:  PDF   ZIP
SENSITRON
SEMICONDUCTOR

221 West Industry Court Deer Park, NY 11729-4681 Phone (631) 586 7600 Fax (631) 242 9798
World Wide Web - http://www.sensitron.com
e-mail address - sales@sensitron.com
60KS200C
90KS200C
90KS200
TECHNICAL DATA
DATA SHEET 4002, REV. A
60KW / 90KW Bi-directional Series

Application:
Aircraft AC Power Bus
AC Power Protection
Shipboard (Line-Line)
Differential AC power Bus

Protection Level:
+200VDC operating; Tailored for 115VAC
Exceed MIL-STD704A and DOD-STD-1399 requirements
UL-94V0 Flammability Classification

60KW:
Rating Condition
Minimum
Maximum
Units
Peak Pulse Power Dissipation
@ 25
0
C, 1ms
-
60,000
Watts
Steady State Power Dissipation
@ 25
0
C - 10
Watts
T
clamping
0 Volts to V
(BR)
-
<
1x 10 8 Seconds
Operating & Storage Temp.
-
-55
+ 150
0
C
Capacitance
@ 0V DC
-
170
pF


Part Number
Reverse Stand-
Off Voltage
V
WM
(Volts)
Maximum
Reverse
Leakage @ V
wm
I
D
(
A)
Minimum
Breakdown
Voltage @ 1 mA
V
(BR)
(Volts)
Maximum
Clamping
Voltage @ I
PP
V
c
(Volts)
Maximum
Peak Pulse
Current
I
PP
(Amps)
60KS200C
180
10
200 ~ 225
335
180
90KW:
Rating Condition
Minimum
Maximum
Units
Peak Pulse Power Dissipation
@ 25
0
C, 1ms
-
90,000
Watts
Steady State Power Dissipation
@ 25
0
C - 10
Watts
T
clamping
0 Volts to V
(BR)
-
<
1x 10 8
Seconds
Operating & Storage Temp.
-
-65
+ 150
0
C
Capacitance
@ 0V DC
-
170
pF


Part Number
Reverse Stand-
Off Voltage
V
WM
(Volts)
Maximum
Reverse
Leakage @ V
wm
I
D
(
A)
Minimum
Breakdown
Voltage @ 1 mA
V
(BR)
(Volts)
Maximum
Clamping
Voltage @ I
PP
V
c
(Volts)
Maximum
Peak Pulse
Current
I
PP
(Amps)
90KS200C
180
0.5
200 ~ 225
280
180
90KS200
180
10
200 ~ 225
335
270
SENSITRON
SEMICONDUCTOR

221 West Industry Court Deer Park, NY 11729-4681 Phone (631) 586 7600 Fax (631) 242 9798
World Wide Web - http://www.sensitron.com
e-mail address - sales@sensitron.com
60KS200C
90KS200C
90KS200
TECHNICAL DATA
DATA SHEET 4002, REV. A



SENSITRON
SEMICONDUCTOR

221 West Industry Court Deer Park, NY 11729-4681 Phone (631) 586 7600 Fax (631) 242 9798
World Wide Web - http://www.sensitron.com
e-mail address - sales@sensitron.com
60KS200C
90KS200C
90KS200
TECHNICAL DATA
DATA SHEET 4002, REV. A



DISCLAIMER:
1- The information given herein, including the specifications and dimensions, is subject to change without prior notice to improve product
characteristics. Before ordering, purchasers are advised to contact the Sensitron Semiconductor sales department for the latest version of the
datasheet(s).
2- In cases where extremely high reliability is required (such as use in nuclear power control, aerospace and aviation, traffic equipment, medical
equipment , and safety equipment) , safety should be ensured by using semiconductor devices that feature assured safety or by means of users'
fail-safe precautions or other arrangement .
3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of
the user's units according to the datasheet(s). Sensitron Semiconductor assumes no responsibility for any intellectual property claims or any
other problems that may result from applications of information, products or circuits described in the datasheets.
4- In no event shall Sensitron Semiconductor be liable for any failure in a semiconductor device or any secondary damage resulting from use at
a value exceeding the absolute maximum rating.
5- No license is granted by the datasheet(s) under any patents or other rights of any third party or Sensitron Semiconductor.
6- The datasheet(s) may not be reproduced or duplicated, in any form, in whole or part, without the expressed written permission of Sensitron
Semiconductor.
7- The products (technologies) described in the datasheet(s) are not to be provided to any party whose purpose in their application will hinder
maintenance of international peace and safety nor are they to be applied to that purpose by their direct purchasers or any third party. When
exporting these products (technologies), the necessary procedures are to be taken in accordance with related laws and regulations.