ChipFind - документация

Электронный компонент: AS225-313LF

Скачать:  PDF   ZIP
Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
200148 Rev. A Skyworks Proprietary and Confidential Information. Products and product information are subject to change without notice. February 15, 2005
1
AS225-313, AS225-313LF: PHEMT GaAs IC 1 W Low Loss
0.16 GHz SPDT Switch
DATA SHEET
Application
WLAN 802.11a, b, g
Features
Positive low voltage control (0/+3 V)
Low insertion loss (0.6 dB, 0.16 GHz)
High linearity (IIP3 = 53 dBm @ 3 V)
Miniature QFN-6 pin plastic package (2 mm x 3 mm)
PHEMT process
Available lead (Pb)-free MSL-2 @ 250 C per JEDEC J-STD-020
QFN-6
12 Max.
3
2
1
0.118
(3.00 mm)
BSC
0.35 0.08 mm
0.05 0.05
0.29 x 0.35
0.039
(1.00 mm) Max.
0.001
(0.025 mm)
0.001
(0.025 mm)
Top View
Side View
Bottom View
6
5
4
0.078 (2.00 mm)
BSC
3
2
1
6
5
4
1.02
0.95 BSC
0.64 BSC
Pin 1
Indicator
Description
The AS225-313 is a 0.16 GHz PHEMT GaAs IC SPDT antenna
switch. Designed for WLAN applications, this device is capable
of switching 1 W microwave signals with 3 V control voltage
while maintaining high linearity performance. The switch covers
the entire 802.11a, b and g frequency ranges. The low loss, high
isolation, high linearity and low cost features make this switch
ideal for Wireless LAN systems.
Skyworks offers lead (Pb)-free "environmentally
friendly" packaging that is RoHS compliant
(European Parliament for the Restriction of
Hazardous Substances).
NEW
Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
February 15, 2005 Skyworks Proprietary and Confidential Information Products and Product Information are Subject to Change Without Notice. 200148 Rev. A
DATA SHEET AS225-313, AS225-313LF
2
Parameter
Test Condition
Frequency
Min.
Typ.
Max.
Unit
Insertion loss
J
1
J
2
, J
1
J
3
0.106.00 GHz
0.60
0.75
dB
2.402.50 GHz
0.50
0.65
dB
5.155.85 GHz
0.60
0.70
dB
Isolation
J
1
J
2
, J
1
J
3
0.106.00 GHz
18
20
dB
2.402.50 GHz
18
20
dB
5.155.85 GHz
19
21
dB
Return loss
J
1
J
2
, J
1
J
3
0.106.00 GHz
18
20
dB
2.402.50 GHz
23
25
dB
5.155.85 GHz
21
23
dB
Electrical Specifications at 25 C
Parameter
Condition
Frequency
Min.
Typ.
Max.
Unit
P
1 dB
@ 3.0 V
5200 MHz
30
dBm
@ 5.0 V
5200 MHz
34
dBm
2nd harmonic
P
IN
= 22 dBm, V
C
= 3 V
2450 MHz
70
dBc
V
C
= 5 V
2450 MHz
75
dBc
3rd harmonic
P
IN
= 22 dBm, V
C
= 3 V
2450 MHz
68
dBc
V
C
= 5 V
2450 MHz
70
dBc
Input IP3
Two-tone 15 dBm, 5 MHz spacing
0/3 V
5200 MHz
53
dBm
0/5 V
5200 MHz
55
dBm
Control voltage
V
C HIGH
2.5
3.0
5.0
V
V
C LOW
-0.25
+0.25
V
Gate leakage
V
C
= 3 V
10
100
A
V
C
= 5 V
15
200
A
Operating Characteristics at 25 C
DATA SHEET AS225-313, AS225-313LF
Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
200148 Rev. A Skyworks Proprietary and Confidential Information Products and Product Information are Subject to Change Without Notice. February 15, 2005
3
C
BL
C
BL
V
1
J
1
V
2
J
2
GND
J
3
C
BL
3
2
1
6
5
4
Pin Out (Top View)
V
1
V
2
J
1
J
2
J
1
J
3
0
V
HIGH
Isolation
Insertion loss
V
HIGH
0
Insertion loss
Isolation
Truth Table
V
HIGH
= +2.5 to +5 V.
DC blocking capacitors (C
BL
) must be supplied externally.
C
BL
= 15 pF.
Loss (dB)
Frequency (GHz)
Insertion Loss vs. Frequency
-2.0
0
1
2
3
4
5
6
-1.8
-1.6
-1.4
-1.2
-0.8
-0.6
-0.4
-0.2
0
-1.0
J
1
J
2
Path
J
1
J
3
Path
Isolation (dB)
Frequency (GHz)
Isolation vs. Frequency
-40
-35
-30
-25
-20
-15
-10
-5
0
J
1
J
2
Path
J
1
J
3
Path
0
1
2
3
4
5
6
Return Loss (dB)
Frequency (GHz)
Return Loss vs. Frequency
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
J
1
J
2
Path
J
1
J
3
Path
0
1
2
3
4
5
6
Typical Performance Data (0, +3 V)
Characteristic
Value
Max input power @ 0/3 V
32 dBm
Max input power @ 0/5 V
35 dBm
Operating voltage
+8.0 V
Operating temperature
-40 C to +85 C
Storage temperature
-65 C to +150 C
Absolute Maximum Ratings
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, Electrostatic Discharge (ESD) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.